Abstract
High-energy X-rays (HEX-rays) with photon energies on order of 100 keV have attractive characteristics, such as comparably low absorption, high spatial resolution and the ability to access inner-shell states of heavy atoms. These properties are advantageous for many applications ranging from studies of bulk materials to the investigation of materials in extreme conditions. Ultrafast X-ray diffraction allows the direct imaging of atomic dynamics simultaneously on its natural time and length scale. However, using HEX-rays for ultrafast studies has been limited due to the lack of sources that can generate pulses of sufficiently short (femtosecond) duration in this wavelength range. Here we show single-crystal diffraction using ultrashort ~90 keV HEX-ray pulses generated by an all-optical source based on inverse Compton scattering. We also demonstrate a method for measuring the crystal lattice spacing in a single shot that contains only ~105 photons in a spectral bandwidth of ~50% full width at half maximum (FWHM). Our approach allows us to obtain structural information from the full X-ray spectrum. As target we use a cylindrically bent Ge crystal in Laue transmission geometry. This experiment constitutes a first step towards measurements of ultrafast atomic dynamics using femtosecond HEX-ray pulses.
Similar content being viewed by others
Introduction
Experiments using HEX-rays with photon energies on order of 100 keV can access information that is complementary to that obtained by lower-energy hard X-ray methods, which typically operate at photon energies around 10 keV. In particular, due to the comparatively low photo-absorption cross-section, HEX-rays have a high penetration depth which allows the investigation of bulk materials1 or solids and liquids in extreme conditions2, such as under high pressures and at high densities3 or at high temperatures4. The large momentum of HEX photons can be used in scattering to access information that cannot be obtained with lower-energetic X-rays. More specifically, the large momentum transfer in HEX diffraction experiments enables measurements with a significantly higher spatial resolution and the almost flat Ewald sphere allows the observation of a large part of reciprocal space spanning several Brillouin zones in a single geometry. This can be of particular advantage in measurements of phonon distributions via diffuse scattering experiments1.
Tunable HEX-ray beams are routinely generated using synchrotron emission from relativistic electron beams that propagate through dipole magnets or permanent-magnet wigglers5. The wavelength of the emitted radiation can be adjusted over a wide range by varying the energy of the electron beam6. However, the pulse duration of storage-ring based synchrotron facilities is typically limited to 30–100 ps, which is not sufficiently short to perform studies of ultrafast dynamics on the atomic temporal scale. HEX-ray pulses with a duration of 20 ps have been generated using a more compact source that is based on inverse Compton scattering of optical photons (laser wiggler) from a relativistic electron beam7. X-ray pulses with sub-picosecond duration using storage-ring based sources have been generated by sophisticated electron beam manipulations8 and by a perpendicular Compton scattering geometry9 however at the cost of greatly reduced photon flux. Recently, X-ray free-electron lasers (XFELs)10,11 that are capable of ultrashort X-ray pulses with enormous intensities have become available. However, current facilities cannot reach high-energy X-ray photon energies.
Here, we use an all-optical inverse Compton scattering source where both, the relativistic electron beam and the optical wiggler are generated by a laser12. The relativistic electron pulse is produced by a laser-wakefield accelerator, in which a high-power femtosecond laser pulse is focused into a gas target where it excites a plasma wave13. Electrons are accelerated by this wave to relativistic energies within a distance of only a few millimeters. This method can be used to drive an X-ray source with a relatively compact footprint. More importantly, it enables the possibility of investigating atomic dynamics on an ultrafast time scale as the generated electron bunches (and thus the subsequently generated X-ray pulses) are intrinsically only a few femtoseconds long with a perfect temporal synchronization to the driver laser14,15. However, these sources typically generate pulses with a comparatively broad bandwidth (a few tens of percent) and operate at a relatively low repetition rate on order of 1 Hz. An additional challenge resulting from the compact geometry of these sources is the background radiation that is mainly generated by scattering of the relativistic electron beam at the chamber walls and the beam dump as well as the highly noisy environment typically present at high-power laser interactions.
Here we demonstrate a technique that enables diffraction experiments using such beam parameters. To this end, we use HEX-rays to observe diffraction from the (220) reflection of a cylindrically bent Ge crystal. The crystal was used in a Laue transmission X-ray spectrometer geometry16,17. As detector we used a pixelated energy-resolving X-ray camera in single-photon counting mode18. In this arrangement, we were able to filter the diffraction signal in photon energy by using the energy resolution of the camera. The additional independent spectral information obtained by the spatial dispersion of the crystal diffraction allowed us to determine the crystal lattice constant despite significant background contamination. A similar energy-resolved approach based on powder diffraction has been proposed as in-line X-ray diagnostics19 and has been used as in situ shock compression diagnostics using a flat crystal20. We were able to demonstrate that through energy filtering of the diffraction signal, it is possible to use the full X-ray spectrum of ~50% (FWHM) for the determination of the crystal lattice spacing. Specifically, we were able to resolve the Ge(220) lattice spacing to be 2 Å with a spatial resolution of 2.1 pm (one standard deviation). We extended the method to demonstrate that we can measure the lattice constant using only a single pulse that contained just ~105 X-ray photons in a 50% bandwidth at a central photon energy of 90 keV. Single-shot determination of the lattice constant is of particular interest for experiments that measure systems with many degrees of freedom, such as investigations of time-resolved dynamics that require measurements at many different time steps or for experiments that investigate non-reversible excitations. Since in our case the lattice constant is well known, we also used the method to retrieve the source spectrum with minimal background contamination.
Results
Experimental Setup
For the experiment, we used an ultrafast all-optical X-ray source12. The X-rays were produced by inverse Compton scattering of an optical laser beam (800 nm) from a relativistic electron beam, which was generated using laser-wakefield acceleration (for more details see methods). The source is capable of generating up to 106 photons per shot and for this experiment was operated at a central photon energy of ~90 keV with a relative energy spread of ~50% (FWHM). The X-ray beam has a divergence on order of ~10 mrad and a shot-to-shot pointing fluctuation of ~10 mrad. As target we used a 0.16 mm thick cylindrically bent Ge crystal with a radius of curvature (ROC) of 0.254 m located in air at a distance of 2.25 m from the X-ray source (see Fig. 1a). The Ge crystal is placed in a Cauchois-type transmission spectrometer setup21. In this geometry, X-rays of equal energy that are diffracted by the crystal from a position close to the spectrometer axis are focused onto a circle (Rowland circle) with a diameter that is equal to the ROC of the bent crystal16. The spectral dispersion X D of photon energy E on a flat detector located a distance D behind the focal circle is given by21
where n is the diffraction order, h the Planck constant, c the speed of light, d latt the crystal lattice spacing of the used reflection, R the crystal radius of curvature and B the distance from the slit to focal circle (see Fig. 1b). The dispersion distance X D from the spectrometer axis scales linearly inverse with the photon energy E. We used the (Laue) reflection of the (220) planes of a Ge crystal, for which d latt ~2 Å. As detector we used a pixelated energy-resolving high energy X-ray HEXITEC camera based on a CdTe crystal18. It has an active area of 20 × 20 mm2 with 80 × 80 pixels each with a size of 250 × 250 µm2. In order to work in single-photon counting mode, the detector was located at 2.5 m from the source.
Photon-energy resolved dispersion measurement
The diffraction signal was recorded for every X-ray shot. The total signal obtained by the summation of 87 consecutive shots is shown in Fig. 2. The lower-right corner of the image shows the undispersed direct beam transmitted through a pinhole in the spectrometer entrance window. Due to the finite chip size only a fraction of the dispersed beam was recorded.
At the photon energy range used in the experiment, the X-ray camera has an intrinsic energy-resolution of ~1 keV (FWHM)18, which allows us to spectrally filter the observed signal. By using the combined information of the energy resolution of the X-ray detector and the spatial dispersion of the crystal diffraction we can significantly increase the signal to noise ratio. To this end, for each individual shot we spectrally filter the recorded images into narrow energy bands in a range of 50–150 keV using the camera energy resolution. We integrate the filtered images along the vertical (non-dispersion) dimension. An example of this method for selected energy bands can be seen in Fig. 3. To verify the validity of this method, we compare the peak of the integrated lineout that we have obtained for each energy band with the expected spectral dispersion given by equation (1). Figure 4 shows the excellent agreement of the camera energy-selected peaks with the theoretical dispersion curve adjusted for our spectrometer setup (see methods).
Retrieved source spectrum
Since in our case the lattice constant of the crystal is well known, we can use the energy-filtered diffraction signal to determine the spectrum of the X-ray source. In principle, the source spectrum can be obtained from either the crystal dispersion or by using the energy-resolution of the X-ray camera. However, the recorded diffraction images contain a significant background that is mainly due to the interaction of the relativistic electron beam with the beam dump and is visible despite massive shielding of the detector. The comparison of background to signal can be approximately estimated from the photon-energy filtered images shown in Fig. 3. The background can be measured by only operating the electron accelerator while blocking the backscattering laser pulse, such that no inverse Compton scattering X-rays are generated. However, it is challenging to correct for in a single shot as it strongly varies in both, energy and spatial distribution from shot to shot. In order to obtain a spectrum with significantly decreased background contamination, we use the combined information obtained from the spatial dispersion due to the crystal diffraction and the camera energy-filtered signal. We filter out the background in the data post-processing by correlating the spatial position of a photon on the detector with its energy. To this end, we select a narrow photon energy-band with a width according to the camera resolution (~1 keV), spatially filter the image according to the crystal spectral dispersion given by equation (1) and then vertically integrate (perpendicular to spectral dispersion direction) the signal. Extending this method over the whole energy range allows us to retrieve the spectral photon density of the source (see Fig. 5). In order to obtain the source photon number, we have taken into account the integrated Laue diffraction efficiency of the Ge(220) reflection extracted from Fig. 6a of ref.21 for each photon energy (see methods) and the beamline transmission. Note that on average we detect only part of the total X-ray beam. This is because the solid angle of the fraction of the crystal, for which the diffraction pattern is detected by the camera is ~5 × 10−5 sr and the beam divergence and shot-to-shot pointing fluctuation each are on order of 10 mrad in the horizontal and vertical direction. By using a long propagation distance of ~2.5 m between the source and the detector we sufficiently decrease the photon flux on the camera to operate in single-photon counting mode. Regardless, our method is robust to photon pile-up, a process where two photons that are simultaneously detected by the same pixel appear as a single photon of higher energy. In case of pile-up, the camera would detect a higher photon energy, which would skew the measured shape of the spectrum. However, due to the additional discrimination of the spatial location of the detected photons, in our case pile-up does not distort the measurement.
Determination of the Ge(220) lattice constant
We can also use this method to determine the lattice constant of the crystal. In particular, the correlation of the photon-energy filtered data with the crystal spectral dispersion allows us to get a high-resolution measurement of the lattice parameter, even from a single shot with only ~105 photons and a comparably broad spectrum of ~50% (FWHM). Figure 6 shows the photon-energy resolved diffraction pattern for the sum of 87 shots. The figure has been generated by energy-filtering the total signal using the X-ray camera resolution and vertically integrating the image for each energy. Note that unlike for the extraction of the source spectrum, in this case the signal is not filtered by the horizontal dispersion position. Despite the noisy background, a clear diffraction signal from the Ge(220) planes can be seen. This method allows us to perform structural analysis of the crystal lattice using the full bandwidth of the X-ray spectrum.
In order to infer the lattice constant of the crystal from the photon-energy resolved diffraction signal we determine for each detected photon its energy E and spatial position X d . Through equation (1), we can determine an effective lattice constant d for each photon. We perform this analysis for every shot. The histogram for all 87 shots can be seen in Fig. 7a. The known lattice parameter for Ge is d = 5.658 Å and for the (220) planes is expected to be \({d}_{220}=d/\sqrt{{h}^{2}+{k}^{2}+{l}^{2}}\approx 2.0{\AA }\), where h, k and l are the Miller indices of the reflection. The histogram shows a peak well above background at 2.0 Å. From the histogram, we can infer a measurement precision of 2.1 pm (1 standard deviation) for all 87 shots, corresponding to the resolution of our measurement. The main sources of measurement uncertainties are the accuracies of the determination of the spatial positions of the detected photons due to the finite width of the camera pixels of 250 µm and the finite camera energy resolution of ≲1 keV for our photon energy range. The inter-planar distance is determined to be d = 2 ± 0.021 Å.
Single-shot Determination of Ge lattice constant
We also demonstrate that this method allows us to determine the lattice constant with a high-resolution using a single shot with only ~105 photons and a comparably broad spectrum of ~50% (see Fig. 7b). A clear peak well above background can be seen at the Ge(220) lattice spacing. The bin width for the histogram has been chosen to be on order of the measurement uncertainty that has been determined from the sum of 87 shots.
Discussion
We have observed a diffraction signal from a bent single crystal using an ultrafast all-laser driven high-energy X-ray source operated at ~90 keV. By energy-filtering the diffraction signal using an energy-resolving HEX-ray camera, we were able to extract a nearly background free spectrum of the source. More importantly, we were able to demonstrate a technique that can take advantage of the full X-ray bandwidth for atomic-scale structural analysis. This allowed us to deduce the crystal lattice constant using only a single X-ray shot with just ~105 photons and 50% bandwidth. This is of particular interest for experiments that require measurements at many different parameter points, such as investigations of the ultrafast time-evolution of structural dynamics. Despite significant background contamination, the measured signals were well above background. This approach can be beneficial for experiments that are performed in a highly noisy environment as often present in high-power laser interactions. The observed signal can be further enhanced by source developments and by decreasing the X-ray propagation distance to the sample. This is possible as the method is robust to photon pile-up. The method demonstrated here enables the use of novel ultrafast HEX-ray sources that typically generate a comparably low number of photons per shot in a broad bandwidth and operate at relatively low repetition rates for diffraction experiments. In a next step, we will extend this technique to flat crystal samples. In the future, we expect that our approach will enable time-resolved investigations of ultrafast dynamics using novel next-generation femtosecond high-energy X-ray sources.
Methods
All-optical Inverse Compton Scattering Source
The experiments were performed in the Extreme Light Laboratory at the University of Nebraska – Lincoln using the Diocles laser facility. The high-energy X-ray radiation is generated using an all-optical X-ray source. The X-rays were created through inverse Compton scattering of an optical (800 nm) laser beam from a relativistic electron beam, which was simultaneously generated using the same laser system. To this end, the laser beam is split into a driver for the electron accelerator and into a backscattering pulse. The driver pulse (1.4 J, 34 fs) is focused to an intensity of 5.4 × 1018 W/cm2 using an f/14 off-axis parabolic mirror and interacts with a gas jet to generate an electron beam via laser-wakefield acceleration. A dual gas-jet target has been used as accelerator for this experiment22. The X-rays are subsequently generated by the interaction of a backscattering laser pulse (0.3 J, 40 fs) focused to an intensity of 1 × 1018 W/cm2 with the electron beam in a nearly counter-propagating geometry. The source is capable of producing X-ray beams (~106 photons per shot) with photon energies tunable in the range of a few tens of keV to around 10 MeV. Taking into account a 5% energy spread in the laser beam and an electron beam with 5% energy spread, 5% shot-to-shot energy fluctuation and a 10 mrad divergence results in a FWHM bandwidth of the X-ray pulse of \(({\rm{\Delta }}\omega /\omega )\approx 67{\rm{ \% }}\). The photon energy can be increased by increasing the electron beam energy. For this experiment, the source was operated at a central photon energy of ~90 keV. Because of the comparably small normalized vector potential of the backscattering laser beam of a 0 = 0.7, the radiation is mainly emitted into the fundamental peak centered at around 85 keV with a negligible harmonic content. The divergence of the X-ray beam is ~10 mrad and the shot-to-shot pointing fluctuations are also ~10 mrad.
Cauchois-Type Transmission X-ray Spectrometer
A schematic of the spectrometer can be seen in Fig. 1b. The spectrometer uses a 0.16 mm thick cylindrically bent Ge crystal with a radius of curvature (ROC) of 0.254 m in Laue transmission geometry21. The X-ray detector was located at a distance of 2.5 m from the source. The spectrometer was aligned using the drive laser beam. X-rays of equal energy that are emitted from a point source and are incident onto the curved crystal at small angles are focused through Laue diffraction. The X-rays are focused onto a point on the focal circle (Rowland circle) with a diameter that is equal to the ROC of the crystal. The (220) reflection was used in this experiment. According to Bragg’s law, the diffraction angle depends on the photon energy and the spectral dispersion at a detector placed near the Rowland circle is linear with the photon wavelength. The detector is shielded by a lead entrance window and a slit close to the center of the focal circle, such that there is no direct line-of-sight between the source and the detector except for a 1 mm pinhole that indicates the spectrometer axis. The entrance window has two symmetric rectangular openings (each 30.5 mm high and 16.5 mm wide) separated by 6.5 mm opaque lead bar with the pinhole drilled in its center. In order to block any undiffracted radiation, a lead slit is placed where the diffracted polychromatic X-ray beam intersects the spectrometer axis (at a distance B = 12.7 cm from the back of the focal circle). The diffraction pattern was measured with a pixelated 2D energy-resolving X-ray camera. Due to experimental constraints, the camera was located at a distance of D = 1.4 cm from the Rowland circle. The spectrometer was previously calibrated using an image plate placed at D = 0 and a tungsten K-alpha X-ray source and K-edges of Tb (52 keV), Pb (88 keV) and U (115.6 keV) thin foils. For the analysis, a correction for the detector position of D/B = 1.11 has been used in equation (1). Furthermore, a small rotation of the Ge crystal has been taken into account as a constant offset of −1 × 106 Å. In order to shield the detector from background radiation that is mainly generated by scattering of the relativistic electron beam at the chamber walls and the beam dump, the setup was enclosed a lead and Teflon housing.
Energy-resolving Pixelated X-ray Detector
The HEXITEC X-ray camera developed in the UK by the Science and Technology Facilities Council (STFC, UK) uses a 1 mm thick CdTe detector. The chip is composed of an array of 80 × 80 square pixels (250 μm side) with a total area of 20.35 mm × 20.45 mm ref.18. The camera was recording continually using a 100 μs exposure. Only frames with a detectable pinhole image signal (plus one frame earlier and one later) were analyzed. The energy of each detected photon can be deduced from the deposited charge into the camera. The detector is sensitive to X-ray photon energies in the range of 4–200 keV with quantum efficiency of ~100%. In single-photon counting mode, the camera can spatially and spectrally resolve X-ray photons with an energy resolution of 0.8 keV at 59.5 keV (1.5 keV at 141 keV). Charge-sharing between pixels has been found to be negligible as an analysis between single pixels and binned 3 × 3 super-pixels has not shown any significant difference.
Extracted Source Spectrum
The double-differential source spectrum \({d}^{2}I/(dEd\Omega )\) per solid angle dΩ and unit photon energy \({dE}\) can be determined from the measured signal at the detector S(E, dE) at photon energy E, the integrated reflectivity of the crystal δ(E), the quantum efficiency of the detector D(E) and the observed angle by the camera in the non-dispersive direction θ y by
In our case, the integrated efficiency of the Ge(220) reflection is δ(E) ~ 7 × 10−6 rad at 50 keV (3 × 10−6 rad at 100 keV)21, D(E) = 100% and θ y = 6.4 mrad. The beamline transmission including a 8 mm borosilicate window has been taken into account.
Data Availability Statement
The datasets generated during and analyzed during the current study are available from the corresponding author on reasonable request.
References
Liss, K.-D., Bartels, A., Schreyer, A. & Clemens, H. High-Energy X-Rays: A tool for Advanced Bulk Investigations in Materials Science and Physics. Textures Microstruct. 35, 219–252 (2003).
Benmore, C. J. A Review of High-Energy X-Ray Diffraction from Glasses and Liquids. ISRN Mater. Sci. 2012, 1–19 (2012).
Soignard, E., Benmore, C. J. & Yarger, J. L. A perforated diamond anvil cell for high-energy x-ray diffraction of liquids and amorphous solids at high pressure. Rev. Sci. Instrum. 81, 35110 (2010).
Kohara, S. et al. Structural studies of disordered materials using high-energy x-ray diffraction from ambient to extreme conditions. J. Phys. Condens. Matter 19, 506101 (2007).
Onuki, H. & Elleaume, P. Undulators, wigglers and their applications (CRC Press, 2003).
Esarey, E., Ride, S. K. & Sprangle, P. Nonlinear Thomson scattering of intense laser pulses from beams and plasmas. Phys. Rev. E 48, 3003–3021 (1993).
Albert, F. et al. Characterization and applications of a tunable, laser-based, MeV-class Compton-scattering γ-ray source. Phys. Rev. Spec. Top. - Accel. Beams 13, 1–13 (2010).
Schoenlein, R. W. et al. Generation of Femtosecond Pulses of Synchrotron Radiation. Science (80-.). 287, 2237–2240 (2000).
Schoenlein, R. W. et al. Femtosecond X-ray Pulses at 0.4 A Generated by 90 Thomson Scattering: A Tool for Probing the Structural Dynamics of Materials. Science (80-.). 274, 236–238 (1996).
Emma, P. et al. First lasing and operation of an ångstrom-wavelength free-electron laser. Nat. Photonics 4, 641–647 (2010).
Ishikawa, T. et al. A compact X-ray free-electron laser emitting in the sub-angstrom region. Nat. Photonics 6, 540–544 (2012).
Powers, N. D. et al. Quasi-monoenergetic and tunable X-rays from a laser-driven Compton light source. Nat. Photonics 8, 28–31 (2013).
Esarey, E., Schroeder, C. B. & Leemans, W. P. Physics of laser-driven plasma-based electron accelerators. Rev. Mod. Phys. 81, 1229–1285 (2009).
Buck, A. et al. Real-time observation of laser-driven electron acceleration. Nat. Phys. 7, 543–548 (2011).
Lundh, O. et al. Few femtosecond, few kiloampere electron bunch produced by a laser–plasma accelerator. Nat. Phys. 7, 219–222 (2011).
Cauchois, Y. Spectrographie des rayons X par transmission d’un faisceau non canalisé à travers un cristal courbé - I. J. Phys. Radium 3, 320–336 (1932).
DuMond, J. W. M. A High Resolving Power, Curved‐Crystal Focusing Spectrometer for Short Wave‐Length X‐Rays and Gamma‐Rays. Rev. Sci. Instrum. 18, 626–638 (1947).
Seller, P. et al. Pixellated Cd(Zn)Te high-energy X-ray instrument. J. Instrum. 6, C12009 (2011).
Cheung, G. & Hooker, S. M. X-ray characterization by energy-resolved powder diffraction. Phys. Rev. Spec. Top. - Accel. Beams 19, 1–9 (2016).
Patel, S. et al. Single Hit energy-resolved laue diffraction. Rev. Sci. Instrum. 86 (2015).
Seely, J. F., Hudson, L. T., Holland, G. E. & Henins, A. Enhanced x-ray resolving power achieved behind the focal circles of Cauchois spectrometers. Appl. Opt. 47, 2767–2778 (2008).
Golovin, G. et al. Tunable monoenergetic electron beams from independently controllable laser-wakefield acceleration and injection. Phys. Rev. ST Accel. Beams 18, 11301 (2015).
Acknowledgements
This work was supported by the National Science Foundation EPSCoR Track 2 RII Award IIA 1430519 and by the US Department of Energy (DOE), Office of Science, Basic Energy Sciences (BES), award # DE-FG02–05ER15663. This support does not constitute an express or implied endorsement on the part of the Government. The experiment was conducted at the Extreme Light Core Facility at the University of Nebraska-Lincoln with support from the Nebraska Research Initiative. The development of the HEXITEC camera system was supported by the Engineering and Physical Sciences Research Council (EPSRC, UK) Translation Grant EP/H046577/1 and Science & Technology Facilities Council (STFC, UK) Centre for Instrumentation. The authors would like to thank Shah Valloppilly for help during the sample preparation stage.
Author information
Authors and Affiliations
Contributions
M.F. and R.R conceived and designed the experiments. M.D.W., M.C.V., P.S. designed and contributed the X-ray detector. R.R., G.G., J.Z., P.Z., B.Z., M.D.W., M.C.V., P.S., S.C., S.B. and M.F. performed the experiment. R.R., G.G., J.O., M.D.W., M.C.V., P.S. and M.F. contributed to the data analysis. R.R. and M.F. wrote the manuscript with revisions by all co-authors. M.F. and D.U. provided overall supervision.
Corresponding author
Ethics declarations
Competing Interests
The authors declare that they have no competing interests.
Additional information
Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Rakowski, R., Golovin, G., O’Neal, J. et al. Single-shot structural analysis by high-energy X-ray diffraction using an ultrashort all-optical source. Sci Rep 7, 16603 (2017). https://doi.org/10.1038/s41598-017-16477-0
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-017-16477-0
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.