Abstract
Constipation, mainly manifesting as abdominal discomfort and painful defecation, is considered as a chronic disorder. Due to a lack of effective therapy, it imposes a significant economic burden and greatly impacts patients’ quality of life which prompt searches for new, original approaches. Based on the research of vibrating capsule (VC) carried out by Ron et al., we investigated the safety and efficacy of an innovative, multi-mode VC in terms of its effect on defecation in animal studies. The parameters associated with different operation modes of VCs can be detected and adjusted by smartphone controlled external configuration device (ECD). The results of blood tests, physiological parameters, CT scan and pathological examination showed no significant abnormality, which undoubtedly confirmed the safety of VCs. For efficacy studies, defecation frequency of beagles increased after administration of these capsules without influence on stool characters. Meanwhile, the mean time of capsule evacuation tended to be reduced while showing no significant difference between different modes. In summary, this study elucidates the safety and effectiveness of VC in prompting the passage of gastrointestinal walls thus greatly increasing the defecation frequency. This study innovatively displays the promising application of VC in the treatment of constipation.
Similar content being viewed by others
Introduction
Constipation, a common cause of abdominal discomfort and painful defecation, is defined as the less-frequent passage of stool or the passage of hard stool1. Since most of the patients with constipation have symptoms for many years, it is considered a chronic disorder2. Even though a minority of those with constipation seek medical treatment, it still accounts for 8 million annual visits to physicians in the United States3. In a systematic review on the global prevalence of idiopathic constipation, Suares and Ford reported a pooled prevalence of 14%4. It is revealed that the prevalence over 60 can be up to 22%, and is estimated to be as high as 30% in selected populations especially in women, non-whites, those aged >65 years and those with lower socioeconomic status5. With high prevalence, it imposes a significant economic burden in direct healthcare costs as well as having a significant impact on patients’ quality of life and working productivity6, 7.
Based on current schemata, chronic constipation is usually classified into 2 categories: idiopathic (slow-transit and normal-transit) and secondary constipation8. There are many evidence-based therapeutic approaches to the treatment of chronic constipation. World Gastroenterology Organization(WGO) advocates a graded approach to treatment from changes in lifestyle and diet, which includes osmotic laxatives to stimulant laxatives, enemas, and prokinetic drugs. Similarly, the American Society of Colon and Rectal Surgeons regards fiber, fluid supplementation and osmotic laxatives as initial management, and stimulant laxatives as second-line treatment. Surgical management is considered for refractory colonic slow-transit constipation1, 5, 9, 10. While there are many therapeutic options available, the combination of high prevalence, side effects of treatment, high recurrence rate and low patient satisfaction level has prompted searches for new, original approaches.
In 2015, Ron et al.11 carried out research to validate the safety and potential efficacy of a vibrating capsule in the treatment of constipation. The capsule was activated using an electromagnetic signal and the fixed vibrating sequence (A or B, as recommended by the physician) began after a predetermined delay of 6–8 h to allow the capsule to arrive at the colon. It reported no serious adverse events and minor adverse effects were transient. A significant increase in the mean number of bowel movements was seen in 23 of the 26 patients.
A new kind of vibrating capsule with four vibration modes has been developed. This new vibrating capsule may be modulated by a smart-phone controlled external configurator. Compared with that in previous studies, our capsule is directed and activity-controlled externally.
This study investigated the safety and efficacy of an innovative, multi-mode vibrating capsule in terms of its effect on defecation in animals. The main focus was to determine whether the administration of smart phone-controlled VC was feasible in the treatment of constipation with its parameters being detected and adjusted by smartphone externally.
Results
Safety study
Results of physiological and blood parameters
In the first animal study, eight dogs each swallowed three vibrating capsules. In all cases, the dogs’ behaviour and mental status were normal with no signs of nausea, vomiting or oral expulsion of capsules during the follow-up period. After the vibrating sequence began, vibration of the abdomen can be perceived and varied with modes. It was feasible to detect and define the capsule’s activity parameters by the external smartphone-controlled configurator. Of the 24 administrated capsules, all were evacuated two days after ingestion. There was no problem with expulsion of the capsules and capsules were expelled with no morphological abnormality.
After administration of different capsules, there were no clinically significant abnormalities in any of the psychological and blood parameters(P > 0.05).
Pathological examination results
After two hours’ vibration at ultra-high frequency, no signs of intestinal obstruction and perforation were seen on CT scan (Fig. 1A–D). There was no evidence of perforation, ulceration or bleeding macroscopically in the pathological specimens. Parasites were noticed in the small intestine of one dog. There was no microscopic evidence of interstitial edema, glandular distortion, obvious inflammatory cell infiltration and dysplastic epithelium in any of the pathological specimen (Fig. 2A–F).
Efficacy study
No erythrocytes, leukocytes, macrophages, residual chyme or blood was observed in routine stool examination. Meanwhile, fecal transferrin and occult blood test were both negative.
Defecation frequency
In the main efficacy endpoint, there was a significant increase in the frequency of defecation (/day) after capsule ingestion. The median frequency at baseline, low, moderate and high mode were 1 (IQR 0), 2 (IQR 1), 2 (IQR 1) and 2 (IQR 1), respectively (Fig. 3A). The median frequency of defecation was higher than that at the baseline after administration of low (P = 0.001), moderate (P = 0.003) and high mode vibrating capsules(P = 0.001), while there was no statistical difference among these three modes (all P > 0.05).
Stool quantity
Vibrating capsules of different frequency all can increase stool quantity. The median stool quantity at baseline, low, moderate and high mode were 280.55 g (IQR 62.63), 308.6 g (IQR 70.88), 309.3 g (IQR 140.8) and 294.8 g (IQR 81.62), respectively (Fig. 3B). Significant difference was shown between dogs in each VC frequency group (P < 0.001). Stool quantity increased greatly from baseline after administration of vibrating capsules (P = 0.001, <0.001 and 0.01 for low, moderate and high frequencies). Again, no statistical difference existed between each pair of the three modes (all P > 0.05).
Faecal character
The Bristol Stool Chart (BSC) allows patients to identify their stool form using different images with accompanying written descriptors12. According to Bristol Stool Chart, stool form can be classified into 7 types. The median scores of BSC for baseline, low, moderate and high frequency VCs were 5(IQR 1), 5(IQR 0), 5(IQR 0) and 5(IQR 0) (Fig. 3C). No significant difference was shown in stool character between dogs. Similarly, compared with that at baseline, stool character at low, moderate and high frequency existed no prominent abnormalities (all P > 0.05). Meanwhile, no significant changes of stool character were observed between each pair of the three modes.
Time of expulsion
The mean time of expulsion were 37.32 h, 30.07 h and 26.77 h for low, moderate and high frequency VCs, presenting a descending trend (Fig. 3D). In the safety study for ultra-high frequency mode, VCs were found in rectums of six dogs while the other two remained in stomach, with parasites showing up in the small intestine of one dog and the other one stopping working due to mechanical troubles. The mean time for eight dogs to expel the capsules showed no statistically difference (P = 0.346), and neither did the expulsion of capsules at different modes (P = 0.137).
Discussion
Chronic constipation is a disabled disorder affecting approximately 20% of the world’s population. Although considered benign in most cases, chronic constipation can result in chronic illness which can greatly influence the quality of life including fecal impaction, incontinence, hemorrhoids, anal fissures, bleeding, and in the most extreme cases, colon perforation13. Yet the pathogenesis of constipation is still unclear. Given the present situation and advances in treatment, a new innovative vibrating capsule has been developed. With the advantage of easy operation, individualization, low cost and no obvious side effects, they can impinge on the gastrointestinal walls physically, inducing increased peristaltic activity that propel the bowel content through bowels, thus relieving constipation.
In the safety studies, through analyses with the mental status, physiological, blood, stool parameters, CT scan as well as pathological anatomy of dogs, vibrating capsules proved to be highly safe, which is consistent with the study carried by Ron et al. With the assistance of smartphone and wireless configurator, the remaining power can be measured and the frequency of vibrating capsules can also be precisely adjusted as needed externally.
In terms of efficacy studies, the results of the experiment showed a statistically significant increase in the defecation frequency and stool quantity after dogs swallowed VCs, while no significant difference existed in stool character, which confirmed the safety and effectiveness. But there was no significantly difference of defecation frequency and stool quantity between multiple modes, which might have something to do with heterogeneity of dogs.
There was a trend towards a reduction in VC expulsion time with increasing vibration frequency. In the safety study of ultra-high frequency mode, VCs were found in rectums of six dogs after vibrating for three to four hours, which greatly shortened the expulsion time compared with high frequency mode. Given the small sample size, no statistically difference was observed. Thus further studies and constipation models are needed to confirm these issues.
In conclusion, VCs proved to be safe and effective in animal studies and it is feasible for smartphone to control VCs externally. By mechanical stimulation of the gastrointestinal walls, capsules can greatly promote defecation frequency without any abnormality in stool character. Meanwhile, the mean time of expulsion had a descending trend with frequency of VCs increased. Ron et al. has depicted that vibrating capsules can greatly improve the mean number of bowel movements11. Given the defecation promotion effect of VC illustrated by our study, we assumed that VCs may greatly relieve constipation. Thus we will further our research to validate the clinical application of VCs in constipation management with these encouraging results.
Methods
Study object
Experimental subjects are all quarantine qualified beagles, purchased from Shanghai Jiagan Biological Technology Co. Ltd (female: male = 1: 1), with 30–40 cm in height and 9.3 ± 1.7 Kg in weight (laboratory animal production certificate No.SCXK 2010-0028).
Dogs were acclimatized for 10–15 days to exclude stress involvement. During the acclimatization period, eight dogs were raised in stainless cages respectively at 19–26 ± 4 °C with humidity 40–70%, gas change 8–10/h and day and night ratio 12 h/12 h. Each dog had free access to 450 g food and 1500 ml water daily.
Study site
The study was conducted in the animal laboratory center of Second Military Medical University (animal laboratory licence No. SYXK 2012-0003).The experimental protocol was approved by Laboratory Animal Ethics Committee of Second Military Medical University (animal ethical review No.13071002121). All experiments were conducted in accordance with the National Institute of Health Guide for the Care and Use of Laboratory Animals.
Study intervention
The intervention apparatus is composed of the capsule itself and an external configuration device (ECD). The capsule is developed by ANKON Medical Technology Co. Ltd., with 26.7 mm in length, 11.8 mm in diameter and 4.5 ± 0.5 g in weight. The vibration of the capsule can be set at four different modes by pushing the corresponding buttons on the ECD, that is dormancy, low, moderate and high. The capsule stops vibrating at the dormancy mode, and the vibration frequency ratio among the mode of high, moderate and low is 1:0.8:0.5°.
There is a two-way RF communication between VC and ECD, thus allowing VC to generate abrupt vibration by an eccentric motor. Once the ECD is put near the abdomen, the vibration mode can be activated and changed by the ECD. Moreover, a smartphone can communicate the ECD through an APP called VCP, which makes it feasible to select the mode and define the activity parameters of VCs externally. Semiconductor chip inside each VC with unique serial number is for recognition and manipulation (Figs 4 and 5).
Study measurements
Physiological parameters
Continuously recorded physiological parameters including temperature (°C), heart rate (bpm), respiration (times/m), weight (Kg), conscious status and behaviour (normality, somnolence, stupor, coma, nervousness, restlessness, laziness, barking, groaning, aggression, etc.), daily intake (g) and daily drink (ml) of beagles for 5 days.
Blood parameters
Fasting venous blood was examined for white blood cell count (WBC), red blood cell count (RBC), hemoglobin (Hb), platelet count (PLT),alanine transaminase (ALT), aspartate aminotransferase (AST), total bilirubin (TBIL), direct bilirubin (DBIL), total protein (TP), albumin (ALB), urea nitrogen (BUN), serum creatinine (SCR), potassium (K) and sodium (Na).
Stool parameters
Stool parameters recorded were consisted of daily defecation quantity(g), defecation frequency and stool characters. Morning fecal specimen were taken for routine and occult blood test.
Study Design
Study at normal mode
In the first animal study, eight dogs began to fast at 20:00 pm the day before the program, and all the psychological and stool parameters were recorded 12 hours later. At 9:00 am, each of the eight dogs initially swallowed one capsule. Then dogs had free access to food and water. The vibrating sequence began at low frequency after a predetermined delay of 2 h to allow the capsule to pass through the pylorus. Researchers observed and reported all the parameters needed at 11:00, 14:00, 17:00 that day and at 08:00, 14:00, 17:00 every day thereafter until the expulsion of the capsule was confirmed in the stool collection kit. Appearance of capsules, stool characters, quantity and color all needed close observation and record. The day after administration of capsules, blood routine, biochemical panel, stool routine and occult blood test were reviewed. After the expulsion of first capsule was confirmed, another one would be given at least 3 days later for the investigation of other modes.
Safety study at ultra-high frequency mode
The vibrating sequence was set at ultra-high frequency and the previous steps were repeated for capsule administration. Abdominal CT scan was performed after two hours’ vibration. Thereafter, with dogs euthanized and dissected, gastrointestinal explorations were carried out immediately. Biopsies with specimen of 3 cm x3 cm in size were obtained wherever any possible macroscopic lesions were identified.
Statistical analyses
Data were presented as median with interquartile range (IQR) for continuous variables. Statistical analyses were conducted using SAS” version 21.0. The covariance analysis was applied for testing the statistical significance of changes between the baseline assessment and the multiple parameters in treatment period with a final two-sided P value of less than 0.05 indicating statistical difference.
References
Greenwald, B. J. Clinical practice guidelines for pediatric constipation. J Am Acad Nurse Pract. 22(7), 332–338, doi:10.1111/jaan.2010.22.issue-7 (2010).
Dik, V. K. et al. Constipation-related direct medical costs in 16887 patients newly diagnosed with chronic constipation. Eur J Gastroenterol Hepatol. 26(11), 1260–1266, doi:10.1097/MEG.0000000000000167 (2014).
Wald, A. Constipation: Advances in Diagnosis and Treatment. Jama 315(2), 185–191, doi:10.1001/jama.2015.16994 (2016).
Ford, A. C. et al. American College of Gastroenterology monograph on the management of irritable bowel syndrome and chronic idiopathic constipation. The American journal of gastroenterology. 109 (Suppl 1), S2–26, quiz S27 (2014).
Paquette, I. M. et al. The American Society of Colon and Rectal Surgeons’ Clinical Practice Guideline for the Evaluation and Management of Constipation. Dis Colon Rectum. 59(6), 479–492, doi:10.1097/DCR.0000000000000599 (2016).
Cai, Q. et al. Healthcare costs among patients with chronic constipation: a retrospective claims analysis in a commercially insured population. J Med Econ. 17(2), 148–158, doi:10.3111/13696998.2013.860375 (2014).
Nyrop, K. A. et al. Costs of health care for irritable bowel syndrome, chronic constipation, functional diarrhoea and functional abdominal pain. Aliment Pharmacol Ther. 26(2), 237–248, doi:10.1111/j.1365-2036.2007.03370.x (2007).
Brenner, D. M. & Shah, M. Chronic Constipation. Curr Gastroenterol Rep. 17(12), 205–216, doi:10.1016/j.gtc.2016.02.013 (2016).
Basilisco, G. & Coletta, M. Chronic constipation: a critical review. Dig Liver Dis. 45(11), 886–893, doi:10.1016/j.dld.2013.03.016 (2013).
Lindberg, G. et al. World Gastroenterology Organisation Global Guideline Constipation—A Global Perspective. J Clin Gastroenterol. 45(6), 483–487, doi:10.1097/MCG.0b013e31820fb914 (2011).
Ron, Y. et al. Safety and efficacy of the vibrating capsule, an innovative non-pharmacological treatment modality for chronic constipation. Neurogastroenterol Motil. 27(1), 99–104, doi:10.1111/nmo.12485 (2015).
Amarenco, G. Bristol Stool Chart: Prospective and monocentric study of “stools introspection” in healthy subjects. Prog Urol. 24(11), 708–713, doi:10.1016/j.purol.2014.06.008 (2014).
Brenner, D. M. & Shah, M. Chronic Constipation. Gastroenterol Clin North Am. 45(2), 205–216, doi:10.1016/j.gtc.2016.02.013 (2016).
Acknowledgements
We would like to thank Prof. Xiao-Dong Duan, Prof. Guo-Hua Xiao, and Prof. Xin-Hong Wang, from Ankon Technologies Co. Ltd., for their technical assistance. We also want to extend our gratitude to Mark Edward McAlindon, from Department of Gastroenterology, Royal Hallamshire Hospital, Sheffield Teaching Hospitals NHS Trust, UK, for his constructive comments and reviewing the English text. This study is supported by grants from the National Natural Science Foundation of China (81422010 to ZL), Foundation for the Author of National Excellent Doctoral Dissertation of China (201271 to ZL), the Shuguang Program of Shanghai Education Development Foundation and Shanghai Municipal Education Commission (15SG33 to ZL); the Chang Jiang Scholars Program of Ministry of Education (Q2015190 to ZL), China; the Shanghai Health and Family Planning Commission Plans to Young Talents (to Z. Liao, No. XYQ2013070), the Shanghai Talent Development Fund (to Z. Liao, No. 201364), and the Outstanding Young Scholars Fund of Second Military Medical University (to Z. Liao).
Author information
Authors and Affiliations
Contributions
Study concept and design (Z.L.); conduct of the study (J.Y., T.G.W., C.W.S.); acquisition of data (Y.W., S.G.Z., A.J.Z.); analysis and interpretation of data (Z.Q.Q., C.H.H., G.L.D.); drafting of the manuscript (Z.L., Y.J., Q.Y.Y.); critical revision of the manuscript for important intellectual content (Z.S.L.); statistical analysis (Z.Q.Q., T.G.W.); obtained funding (Z.L., Z.S.L.).
Corresponding authors
Ethics declarations
Competing Interests
The authors declare that they have no competing interests.
Additional information
Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Yu, J., Qian, YY., He, CH. et al. Safety and Efficacy of a New Smartphone-controlled Vibrating Capsule on Defecation in Beagles. Sci Rep 7, 2841 (2017). https://doi.org/10.1038/s41598-017-02844-4
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-017-02844-4
This article is cited by
-
End-to-end design of ingestible electronics
Nature Electronics (2024)
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.