Abstract
A philosophical shift has occurred in the field of biomedical sciences from treatment of late-stage disease symptoms to early detection and prevention. Ceria nanoparticles (CNPs) have been demonstrated to neutralize free radical chemical species associated with many life-threatening disease states such as cancers and neurodegenerative diseases by undergoing redox changes (Ce3+ ↔ Ce4+). Herein, we investigate the electrochemical response of multi-valent CNPs in presence of hydrogen peroxide and demonstrate an enzyme-free CNP-based biosensor capable of ultra-low (limit of quantitation: 0.1 pM) detection. Several preparations of CNPs with varying Ce3+:Ce4+ are produced and are analyzed by electrochemical methods. We find that an increasing magnitude of response in cyclic voltammetry and chronoamperometry correlates with increasing Ce4+ relative to Ce3+ and utilize this finding in the design of the sensor platform. The sensor retains sensitivity across a range of pH’s and temperatures, wherein enzyme-based sensors will not function, and in blood serum: reflecting selectivity and robustness as a potential implantable biomedical device.
Similar content being viewed by others
Introduction
As new therapies and technology are developed, the medical community is seeing a change from late-stage disease treatment to early detection and prevention1. This way, treatments are becoming pro-active, rather than reactive, decreasing the incidence or severity of serious and chronic illnesses. This approach has seen great success for those afflicted with early signs of cancer or neurodegenerative diseases such as Alzheimer’s, Parkinson’s, and multiple sclerosis2,3,4,5,6,7. Common to all of these ailments are the production of reactive oxygen species. Specifically, reactive oxygen species evolve as a result of altered, cellular metabolism arising from a given disease state. These species are highly unstable and induce redox of cell structures leading to activation of immune response and apoptosis. Among these hydrogen peroxide (H2O2) has been well-studied as an analyte to describe disease condition.
H2O2 detection is critical to manufacturing, food production, pharmaceuticals, and medicine. Specifically, precise H2O2 detection and quantification is a necessity in food sterilization processes, pharmaceuticals production, and medical devices. Detection has been accomplished using a number of different techniques; namely: titration8, spectroscopy9, fluorescence10, chemiluminescence11, and electrochemical methods. Of these methods, electrochemistry is arguably the simplest: producing fast and precise data while requiring only limited instrumentation, and can be accomplished through analyte oxidation or reduction. Further, detection can be accomplished via simple voltammetric, impedance, and/or amperometric methods. These methods can also be coupled with optical techniques to produce even greater levels of precision (i.e. electrochemical luminescence and photoelectrochemical methods)12, 13. In the past, the technique’s main limitation has been the large overpotential required to induce redox reactions and slow electron transfer kinetics14. Recently, these shortcomings have been overcome through the use of modified electrodes. Specifically, electrodes have been modified with small redox-active molecules, polymers, enzymes, and nanomaterials14, 15. The simplicity and versatility of these electrochemical sensors, strongly suggests their use in biosensors.
Within the field of sensor technology, devices for bio-sensing have seen an especially pronounced growth. Among these, enzymes are used most often for electrochemical sensors and especially in biosensors. Enzyme sensing elements have high sensitivity, selectivity, and fast time of response: making them well-suited for biosensors. However, their function is limited to specific solution conditions and variance from these conditions in pH, ionic strength, temperature, or light exposure can result in significant, in some cases irreversible loss of activity. In the case of H2O2 detection, the most commonly used enzyme is horseradish peroxidase (HRP)16,17,18. However, this protein loses activity as pH changes from pH 8 to 4 (−>60% of initial activity) and from 40 to 20 °C (−30%) when immobilized19. This loss in activity has been attributed to changes in tertiary structure, which is lost completely at 42 °C20. In developing more robust sensors, researchers have turned towards enzyme-free platforms21,22,23. Often, this is accomplished by incorporation of inorganic nanoparticles (e.g. platinum, carbon nanotubes, palladium, iron oxide)21,22,23. Use of these materials have produced sensors with comparable sensitivities to enzyme-based sensors while lifting the restriction to mild conditions. Among these, cerium oxide (ceria) has demonstrated substantial ability to interact with and allow detection of significant analytes24, 25.
Ceria has demonstrated wide, biomimetic reactivity towards reactive oxygen and nitrogen species25,26,27,28,29. This enzyme-mimetic behavior is related to the ratio of Ce3+ to Ce4+ with higher or lower ratios being better suited for different chemical substrates. Additionally, as the dimensions of the ceria lattice are decreased to the nano-scale, the prevalence of Ce3+ increases along with the number of oxygen vacancies due to an increase in bond strain30. Therefore, ceria nanomaterials show unique activity and reactivity28, 31,32,33. Thereby, experimental use of ceria nanomaterials as therapeutic agents for cancers, neurodegenerative diseases, and ophthalmological diseases has been highly successful34,35,36,37,38,39,40,41,42,43. Experimental use of ceria has allowed neutralization of reactive oxygen species and an increase in overall cell viability. In particular ceria interaction with H2O2 has been especially well-studied.
Several studies have been produced which use ceria nanoparticles (CNPs) as sensing elements for H2O2 24, 44,45,46. However, these studies do not demonstrate high sensitivities. Further, the use of CNP-based sensors for biomedical applications have not been studied in blood (protein-containing) conditions, for evaluation of the platform as an implantable, long term use device. In this study, the electrochemical response of CNPs in presence of H2O2, chosen as a surrogate molecule to determine concentrations of reactive oxygen species, is characterized. We use different preparations of CNPs to determine whether the ratio of Ce3+:Ce4+ has a direct relationship with the electrochemical response. Then, the determined relationship is used to develop a biosensor platform optimized for electrochemical response to ultra-low concentrations of H2O2 and functionalized to disallow protein adsorption on the particle surface. This sensor is then tested in blood serum to evaluate the sensors performance in presence of potentially surface-fouling proteins, mimicking the environment experienced by biomedical devices.
Results and Discussion
CNP Physicochemical Characterization
For this study, three different ceria nanoparticle (CNP) formulations (CNP1–3) were produced by varied synthesis methods. X-ray photoelectron spectroscopy (XPS) was performed for each of these to confirm differences in Ce3+:Ce4+ ratio (Table 1). This ratio was found to decrease across the formulations from CNP1 → 3. Before comparing formulations of varied Ce3+:Ce4+ for electrochemical activity, it was necessary to characterize certain physicochemical properties for each; namely: particle size, morphology, and zeta potential (collected in Table 1).
Particle size and morphology were similar for all formulations. Transmission electron microscopy (TEM) micrographs (Fig. 1) show spherical, ~5 nm CNPs. Based on these images and the properties collected in Table 1, we determine that the formulations show particles of comparable size, morphology, and zeta potential. From here, the ability of each formulation to chemically degrade H2O2 was determined via catalase assay.
Catalase assays were performed for all CNP formulations (Fig. 2a) and it was found that lower Ce3+:Ce4+ ratios produced greater catalase activity (i.e. activity increased from CNP1 → 3) due to the redox conversion of Ce4+ → Ce3+, corroborating the findings of past studies[2a]. Given that particles from each formulation varied only in Ce3+:Ce4+ ratio and that catalase activity was found to vary with this ratio, we next performed electrochemical studies to evaluate whether current response showed a similar relationship.
CNPs Electrochemical Characterization
Initially, to characterize the electrochemical behavior of each CNP formulation, CV was performed with 1 mM CNPs and 1 mM H2O2 for all formulations (Fig. 2b). CV scans were completely consistent by the third cycle (used for analysis), with subsequent cycles being largely similar (data not shown). Since the current does not change considerably with successive cycles, we determine that the observed current response does not arise from any side reactions in the solutions (i.e. not from an ECE-type mechanism wherein an electrochemical change elicits a chemical reaction mediating a current signal)19. The overall shape of the obtained CV curves were fairly similar across formulations, suggesting similar electrochemical reactions for all formulations47. The peaks common to all formulations occur at ~0 V (hereafter, peak 1), −0.23 V (peak 2) and 0.4–0.7 V (peak 3). These are attributed to the CNP-mediated reduction of H2O2 (peaks 1 and 2) and the oxidation of the Au electrode (peak 3)48, 49, respectively.
CNPs with lower Ce3+:Ce4+ ratio have a more defined peak 1; this has been attributed to the initial reduction of H2O2 48. In contrast, the higher ratio CNP1 solution shows a more diffuse, wide peak at a similar potential; this behavior is consistent with complex catalysis mechanisms presented in literature49. Specifically, the peak character suggests that reduction initially occurs, however, the catalysis is kinetically restricted for high Ce3+:Ce4+ formulations. Degradation of H2O2, for these formulations occurs very slowly, on the order of days for millimolar concentrations in absence of applied electrical potential50. Additionally, it has been speculated that this diffuse peak represents a multi-step reduction mechanism wherein radical oxygen species (such as superoxide) and/or oxygen are evolved and transiently adsorb at the electrode surface21. Peak 2 represents the complete reduction of H2O2. This peak is seen to be sharp and intense for lower Ce3+:Ce4+ ratio CNP formulations indicative of a fast, diffusion-limited reduction while higher ratio formulations show a more diffuse peak which seems to overlap with peak 1 (as detailed above). In similar work13, 49, this cathodic peak was attributed to the CNP-mediated reduction of surface-complexed O2 2−/O2 − species. The high current increase seen for low ratio formulations was attributed to peroxy-complexed CNPs functioning as nano-electrodes by colliding with the working electrode and facilitating indirect electron transfers from the working electrode to adsorbed oxygen species49, 51, 52. Particle contact with the conductive electrode resulting in degradation of the surface species occurs primarily through the following relationship,
The peak shape/character arises from the high surface coverage of the nanoparticles by the peroxy species: allowing reduction of a large quantity of molecules near-simultaneously49. In support of this, in a study utilizing CNP collision with microelectrodes, individual CNP impacts were observable spikes in current observed for peroxide adsorbed particles relative to CNPs without H2O2 exposure49.
Performing CVs at multiple scan rates and plotting the square root of each scan rate vs. the corresponding peak current (Supplementary Figure S2), we determined that the CNP-mediated peroxide reduction reaction is diffusion-limited47. It is important to note that the reduction response is produced by nanoparticle flux at the electrode surface, the current signal is dependent on the diffusivity of the nanoparticles, rather than of the peroxide species.
In agreement with catalase data, we observed that lower Ce3+:Ce4+ ratio formulations produced a nearly two-fold greater cathodic peak current density as compared to higher ratio formulations (determined by normalizing peak currents with respect to electrode electroactive surface area, described in the Experimental section). Figure 2b details the relative peak current densities for each of the formulations. Lower Ce3+:Ce4+ ratio better facilitate H2O2 reduction based on their oxygen release property. Oxygen release from the CNP lattice is believed to be more favorable for CNPs with higher Ce4+ than is for higher Ce3+ particles53. This may allow for a more favorable reduction reaction by releasing reaction products at a higher rate: explaining the greater cathodic current density for CNP3 over CNP1 as well as the overall shape of the respective CV curves.
Additionally, we saw the reverse trend for anodic current density with higher ratio formulations at peak 3 producing greater current density, similar to literature SOD activity trends25. This peak was attributed to Au oxidation and has been shown to be sensitive to H2O2 concentrations (Supplementary Figure S3)48. However, no consistent trend with H2O2 concentration was observed for this signal and therefore the signal could not be used for analytical measurements (Supplementary Figure S3). From the present study, we cannot determine conclusively whether the observed oxidation reaction (Peak 3) can be ascribed to CNP SOD activity.
Due to the strong relationship between Ce3+:Ce4+ ratio and cathodic current, we determined to study the CNP-mediated H2O2 reduction current response. CA is more suited for quantitative measurements, such as these, over CV47. Therefore, the formulations with the least (CNP1) and greatest (CNP3) Ce3+:Ce4+ ratio were selected for further investigations to confirm the trends in current values observed in CV and to test the efficacy of the particles as an amperometric assay.
CA was performed with several interfering species (chemical substances which experience redox at un-modified electrode surfaces within the tested potential range, are redox agents that could react with ceria, or could react with catalysis products and alter measurements), shown elsewhere to poison H2O2 redox reactions, and with successive additions of 200 μM H2O2 to CNP1 and 3 formulations in dH2O (Supplementary Figure S4)44. None of glucose, uric acid, nor sodium nitrite produced any significant current change (Fig. 3) suggesting strong selectivity towards the target analyte. Further, addition of interfering species and H2O2 did not produce any measurable response in absence of CNPs (data not shown). However, addition of ascorbate produces a chemical reaction with ceria and elicits a weak electrochemical response (Supplementary Discussion S4)54. This interaction is addressed, later, for the formation of a biosensor. Upon addition of H2O2 to CNP solutions, an immediate current response was observed (Fig. 3). Comparing CA data for CNP1 to CNP3 formulations shows significantly greater (>125%) current values for CNP3, similar to the differences observed in CV measures (Supplementary Figure S4). In comparison with CV data, the increased current response likely arises from the proximity of CNPs to the electrode surface. Particle-mediated H2O2 reduction is limited by H2O2 diffusion to the particle-coated electrode surface, rather than by the CNP diffusion limitation for the solution-based CNP method. Therefore, the electrode experiences a greater flux at its surface immediately following peroxide addition, increasing the achieved signal.
Based on these results we believe that CNP formulations with lower Ce3+:Ce4+ are better suited for amperometric detection of H2O2. Further, due to the success of the CNP3 formulation in producing a considerable current, we fabricated a sensor by immobilizing CNPs on a glassy carbon electrode. To optimize our sensor design and in considering the generally observed trend of increasing ionic diffusion for nanomaterials over micron-scale materials, we sought to characterize the influence of nano-scale chemical properties of the ceria film55, 56.
To accomplish this, measurements from the sensor described above were compared with those of an analogous sensor based on a ceria microparticle film (Fig. 4b). As shown, the CNP-based sensor boasts a significantly greater sensitivity. Ostensibly, the nano- character of the particles allows for more efficient/effective surface catalysis resulting in a greater electrochemical signal. This character has been well-studied in ceria and is often ascribed to the bond strain produced in ceria when reduced to nano-dimensions (increasing concentration of Ce3+ at surface)57. Therefore, the CNP-based sensor platform was further analyzed for detection ability.
CA was performed to determine the H2O2 detection range for the CNP-based device. The sensor was able to produce signals at the picomolar (parts per trillion) concentration level (Fig. 4a). This level of detection is highly competitive with enzyme-based sensors which typically function in the nanomolar region45. Further, the sensor is capable of detecting concentrations orders of magnitude lower than comparable inorganic material-based sensors (Table 2). It was found that the sensor produced reliable signals across seven orders of magnitude (from 0.1 pM to 0.1 μM) (Fig. 5). The lower bound of this range was determined using the convention for limit of quantitation (LOQ); specifically,
The obtained range includes concentrations relevant to physiological conditions. Beyond this, the LOQ of this detection range is several orders of magnitude lower than that of enzyme-based devices (nanomolar limits). Further, in comparing with other enzyme-free H2O2 sensors, we see that the tested platform has a limit of quantitation 3 orders of magnitude lower than any of the reviewed sensors; with a comparable range of detection (Table 2). The sensors sensitivity was determined from a semi-log plot of current v. log([H2O2]) (Current = (sensitivity/cm2)(log [H2O2]) + (constant)) to be 0.156 μA/log(M)*cm2. Additionally, chronoamperometric measurements evidence a time of response of ~6 seconds. From here, the sensor platform was tested for robustness in different chemical environments.
Figure 6a,b shows that the sensor experiences no loss in activity across the measured pH (4–8) (standard deviation: <5%) and a slight thermal activation across temperature range (20–40 °C) (standard deviation: 27.3%). Further, as a ceramic material, CNPs exhibit high thermal stability with structure changes only occurring well beyond temperatures practical for biosensing58. In order to utilize the sensor platform as a true biosensor it must be stable against solution leaching and biofouling. The as-synthesized glassy carbon electrodes have a moderately porous structure (Supplementary Figure S6). We believe that this structure played an important role in maintaining CNP-adsorption on the electrode surface as previous attempts with gold working electrodes used for solution-based CNP electrochemical characterization saw significant CNP layer leeching into test solutions (data not shown). However, the CNP comprised film is still vulnerable to degradation and in bio-solutions the surface can be blocked by adsorbed proteins (bio-fouled)59, 60. In addition, sensor operation could be disturbed solely by the change in solution electrochemical properties (due to proteins). Therefore, we next applied a thin layer of Nafion to the sensor and tested in blood serum23.
CA measurement in blood serum showed clear current response upon addition of analyte (Fig. 6c) whereas measurements using sensors without Nafion produced no signal. The sensor retained a sensitivity of 0.103 μA/log(M)*cm2. Further, incubation of the sensor in serum overnight caused no additional loss in sensitivity (data not shown) suggesting resistance to bio-fouling at short time scales. In the future, the stability of the sensor in bio-fouling solutions will be analysed to assess its potential utility as an implantable sensor. Additionally, the Nafion layer prevented the non-specific interaction between ceria and ascorbate. Thereby, the interference from these species was eliminated: further recommending this device platform as a clinical biosensor.
Experimental Section
Materials
Nano-pure diamond distilled water; 30% NH4OH, 30% Hydrogen Peroxide, Cerium nitrate hexa-hydrate (trace metals basis, 99.999%), 1% Nafion, poly(acrylonitrile), sodium phosphate dihydrate, sodium diphosphate monohydrate, sodium acetate, hydrogen chloride, and sheep’s blood serum from Sigma Aldrich; Cerium Oxide nanoparticles 20% colloidal suspension in water from Alfa-Aesar; powder cerium oxide microparticles from REaction a John Mathis company.
Particle Synthesis and Characterization
For this study, three different formulations were produced which were demonstrated in other studies to have dissimilar Ce3+:Ce4+ ratios.
CNP1: Synthesized by dissolving cerium nitrate hexahydrate in 20 mL of dH2O followed by addition of a stoichiometric amount of 30% H2O2. CNP2: Alfa-Aesar CNPs were diluted using dH2O, as required for given measurements. No other processing procedure was performed on these particles. CNP3: NH4OH precipitated CNPs were produced through hydrolysis. Then, this solution was centrifuged at 8000 rpm to collect precipitated particles. The collected particles were then re-suspended in dH2O and titrated to a pH of ~4 using nitric acid.
All CNPs were characterized using XPS (Physical Electronics (PHI5400 ESCA) spectrometer with a monochromatic Al Kα X-ray source at 300 W with a base pressure of 5 × 10−8) Torr) to determine the Ce3+:Ce4+ ratio. UV-Vis spectrophotometry was conducted at 1 mM concentrations. TEM (Phillips FEI Tecnai F30 at 3000 keV) was performed to confirm the crystalline nature of each CNP formulation and to determine particle size and morphology.
Biosensor Fabrication
Si wafers with a natural oxide layer were cut to ~1 × 1 cm squares and cleaned by ultra-sonicating in acetone, ethanol and then water; finally, all wafers were dried under nitrogen. (Synthesis of glassy carbon electrodes detailed in supplementary information as Supplementary method S1) Glassy carbon substrates were then heated to ~300 C and 200 μL of CNPs were dropcast from a 0.2 mM stock solution of CNP3. Following this, the wafers were heated at 300 °C, for 3 hours, in air. Electrodes were subsequently allowed to slowly cool to room temperature inside the furnace.
Electrical contacts were made between glassy carbon (devoid of CNPs) and a polished copper wire using a simple silver paste. The electrodes were then rinsed with de-ionized water and allowed to dry in ambient conditions. When not in use, the electrodes were stored in clear, plastic boxes at room temperature. Electrodes used in blood serum solution were further modified with a thin layer (10 μL of 0.01% in water) of Nafion and allowed to dry overnight under vacuum to prevent protein adsorption to the CNP layer during testing in serum.
Electrochemical Testing
All potentials were referenced against Ag/AgCl electrode. Prior to any experimental measures, Pt-mesh counter electrodes were electrochemically cleaned by cyclic voltammetry (CV) in 0.5 M H2SO4 and the potential range was swept between 1.6 and −0.5 V for 50 cycles at 1 V/s. Electrodes were considered clean when CV scans were consistent. Round-disk Au working electrodes (CH instruments) were cleaned by the same method with the potential swept between 1.2 and −0.4 V. The area under the peak corresponding to Au reduction (~0.8 V) was used to represent the electro-active surface area of the working electrode before experimental measurements. Measured current was then converted to current density using the electrochemically active surface area for comparison across multiple measurements.
Initially, CV was performed with CNPs in solution to characterize CNP electrochemical response in presence of hydrogen peroxide. In solution, redox occurs as particles collide with the working electrode surface. Many electrochemical studies involving nanoparticle collisions with electrode surfaces utilize microelectrodes to record individual particle collisions (primarily to determine particle size, shape, and/or composition). For our study, we resolved to determine the electrochemical activity of similar (size, shape, zeta potential) particles. Due to this, large magnitude particle flux at the electrode-solution interface is desirable. This was accomplished using a macro- working electrode for measurements. Consequently, a stepped current response characteristic of high particle flux was observed compared to the spike response observed in the case of microelectrodes (the sustained current response being due to higher [CNP] and greater electrode surface area)47, 51. Experimental CV was performed with 1 mM CNPs (each with the three different CNP formulations) dispersed in 10 mL of dH2O and a potential range of 0.8 V to −0.3 V at a scan rate of 20 mV/s. H2O2 was added at 0.01, 0.1, 1, 2.5, and 5 mM concentrations and measurements were repeated five times at each concentration. Electrodes were cleaned as described between each measurement. CV was performed in absence of CNPs as a control. Chronoamperometry (CA) was conducted at −0.23 V, based on the redox activity implicated in CV scans, using 1 mM CNPs 1 and 3. Following the start of a measurement, the current was allowed to equilibrate for 30 s. Then, measurement was run for 10 minutes, with same electrode setup as for CV measurements, with addition of analytes or interfering species (200 μM glucose, sodium nitrite, and uric acid) added by pipette in 100 μL volume increments. Subsequently, thin film CNP- or ceria microparticle -based sensors were fabricated on in-house produced glassy carbon electrodes and tested under identical conditions, without interfering species, to assess the influence of nanoscale material properties in the electrochemical response. Biosensor was evaluated using chronoamperometry performed at the same voltage as for CNPs in solution. Addition of H2O2 was done in 100 μL increments following an electrochemical equilibration period of 30 s in either 100 mM NaNO3 or sheep’s blood serum.
Conclusions
In the presented study, several formulations of ceria nanoparticles (CNPs) were prepared and tested for electrochemical response in presence of H2O2. We have shown that the trend observed in CNPs’ Ce3+:Ce4+ for catalase-mimetic degradation of H2O2 extends to electrochemical activity; specifically, particles possessing higher Ce4+ relative to Ce3+ produce superior current response in presence of H2O2 as determined through cyclic voltammetry and chronoamperometry. This chemical property was then used to fabricate an electrochemical biosensor sensing up to 0.1 pM. Temperature and pH showed no significant effect on sensor sensitivity (high sensor stability) and addition of common interfering species elicited no significant current response (high selectivity). Comparing with other inorganic material-based biosensors, our sensor was capable of detection three orders of magnitude below the most sensitive device in literature. Additionally, the ceria-based biosensor demonstrated excellent H2O2 detection in blood serum, with a response time of 6 s and a change in sensitivity from 0.156, in buffer solution, to 0.103 μA/log(M)*cm2, in blood serum. The low limit of quantitation for H2O2 detection in blood serum along with physicochemical stability suggests that the sensor is suitable for immediate detection of disease state as part of an implantable device. However, the performance of the biosensor will need to be assessed following incubation in bio-fluid over longer periods of time.
References
Etzioni, R. et al. The case for early detection. Nature Reviews Cancer 3, 243–252 (2003).
Pepe, M. S. et al. Phases of biomarker development for early detection of cancer. Journal of the National Cancer Institute 93, 1054–1061 (2001).
Huang, Z. et al. Plasma microRNAs are promising novel biomarkers for early detection of colorectal cancer. International journal of cancer 127, 118–126 (2010).
Jacobs, I. J. & Menon, U. Progress and challenges in screening for early detection of ovarian cancer. Molecular & Cellular Proteomics 3, 355–366 (2004).
Tröster, A. I. Neuropsychological characteristics of dementia with Lewy bodies and Parkinson’s disease with dementia: differentiation, early detection, and implications for “mild cognitive impairment” and biomarkers. Neuropsychology review 18, 103–119 (2008).
Berg, D. Biomarkers for the early detection of Parkinson’s and Alzheimer’s disease. Neurodegenerative Diseases 5, 133–136 (2008).
DeKosky, S. T. & Marek, K. Looking backward to move forward: early detection of neurodegenerative disorders. Science 302, 830–834 (2003).
Reichert, J. S., McNeight, S. A. & Rudel, H. W. Determination of Hydrogen Peroxide and Some Related Peroxygen Compounds. Industrial & Engineering Chemistry Analytical Edition 11, 194–197 (1939).
Nogueira, R. F. P., Oliveira, M. C. & Paterlini, W. C. Simple and fast spectrophotometric determination of H2O2 in photo-Fenton reactions using metavanadate. Talanta 66, 86–91, doi:10.1016/j.talanta.2004.10.001 (2005).
Gomes, A., Fernandes, E. & Lima, J. L. F. C. Fluorescence probes used for detection of reactive oxygen species. Journal of Biochemical and Biophysical Methods 65, 45–80, doi:10.1016/j.jbbm.2005.10.003 (2005).
Hanaoka, S., Lin, J.-M. & Yamada, M. Chemiluminescent flow sensor for H2O2 based on the decomposition of H2O2 catalyzed by cobalt (II)-ethanolamine complex immobilized on resin. Analytica Chimica Acta 426, 57–64 (2001).
Pyati, R. & Richter, M. M. ECL–Electrochemical luminescence. Annual Reports Section “C”(Physical Chemistry) 103, 12–78 (2007).
Grätzel, M. Photoelectrochemical cells. Nature 414, 338–344 (2001).
Chen, W., Cai, S., Ren, Q.-Q., Wen, W. & Zhao, Y.-D. Recent advances in electrochemical sensing for hydrogen peroxide: a review. Analyst 137, 49–58, doi:10.1039/C1AN15738H (2012).
Zhao, J. et al. Ultrasensitive electrochemical aptasensor for thrombin based on the amplification of aptamer–AuNPs–HRP conjugates. Biosensors and Bioelectronics 26, 2297–2303, doi:10.1016/j.bios.2010.09.056 (2011).
Xu, Y., Peng, W., Liu, X. & Li, G. A new film for the fabrication of an unmediated H2O2 biosensor. Biosensors and Bioelectronics 20, 533–537, doi:10.1016/j.bios.2004.02.017 (2004).
Delvaux, M., Walcarius, A. & Demoustier-Champagne, S. Electrocatalytic H2O2 amperometric detection using gold nanotube electrode ensembles. Analytica Chimica Acta 525, 221–230, doi:10.1016/j.aca.2004.08.054 (2004).
Long, J. S. et al. Direct electrochemistry of horseradish peroxidase immobilized in a chitosan–[C4mim] [BF4] film: Determination of electrode kinetic parameters. Bioelectrochemistry 74, 183–187, doi:10.1016/j.bioelechem.2008.07.008 (2008).
Temoçin, Z. & Yiğitoğlu, M. Studies on the activity and stability of immobilized horseradish peroxidase on poly(ethylene terephthalate) grafted acrylamide fiber. Bioprocess and Biosystems Engineering 32, 467–474, doi:10.1007/s00449-008-0266-9 (2008).
Chattopadhyay, K. & Mazumdar, S. Structural and Conformational Stability of Horseradish Peroxidase: Effect of Temperature and pH. Biochemistry 39, 263–270, doi:10.1021/bi990729o (2000).
Wang, J. Electrochemical biosensors: Towards point-of-care cancer diagnostics. Biosensors and Bioelectronics 21, 1887–1892, doi:10.1016/j.bios.2005.10.027 (2006).
Qu, F., Yang, M., Shen, G. & Yu, R. Electrochemical biosensing utilizing synergic action of carbon nanotubes and platinum nanowires prepared by template synthesis. Biosensors and Bioelectronics 22, 1749–1755, doi:10.1016/j.bios.2006.08.003 (2007).
You, J.-M. et al. Reductive determination of hydrogen peroxide with MWCNTs-Pd nanoparticles on a modified glassy carbon electrode. Biosensors and Bioelectronics 26, 2287–2291, doi:10.1016/j.bios.2010.09.053 (2011).
Mehta, A., Patil, S., Bang, H., Cho, H. J. & Seal, S. A novel multivalent nanomaterial based hydrogen peroxide sensor. Sensors and Actuators A: Physical 134, 146–151, doi:10.1016/j.sna.2006.05.028 (2007).
Pirmohamed, T. et al. Nanoceria exhibit redox state-dependent catalase mimetic activity. Chemical communications (Cambridge, England) 46, 2736–2738, doi:10.1039/b922024k (2010).
Asati, A., Santra, S., Kaittanis, C., Nath, S. & Perez, J. M. Oxidase Activity of Polymer-Coated Cerium Oxide Nanoparticles. Angewandte Chemie (International ed. in English) 48, 2308–2312, doi:10.1002/anie.200805279 (2009).
Dowding, J. M., Seal, S. & Self, W. T. Cerium oxide nanoparticles accelerate the decay of peroxynitrite (ONOO−). Drug Delivery and Translational Research 3, 375–379, doi:10.1007/s13346-013-0136-0 (2013).
Korsvik, C., Patil, S., Seal, S. & Self, W. T. Superoxide dismutase mimetic properties exhibited by vacancy engineered ceria nanoparticles. Chemical Communications, 1056–1058, 10.1039/B615134E (2007).
Dowding, J. M., Dosani, T., Kumar, A., Seal, S. & Self, W. T. Cerium oxide nanoparticles scavenge nitric oxide radical ([radical dot]NO). Chemical Communications 48, 4896–4898, doi:10.1039/C2CC30485F (2012).
Deshpande, S., Patil, S., Kuchibhatla, S. V. & Seal, S. Size dependency variation in lattice parameter and valency states in nanocrystalline cerium oxide. Applied Physics Letters 87, 133113 (2005).
Gupta, A., Das, S., Neal, C. J. & Seal, S. Controlling the surface chemistry of cerium oxide nanoparticles for biological applications. Journal of Materials Chemistry B. doi:10.1039/C6TB00396F (2016).
Tarnuzzer, R. W., Colon, J., Patil, S. & Seal, S. Vacancy engineered ceria nanostructures for protection from radiation-induced cellular damage. Nano letters 5, 2573–2577 (2005).
Heckert, E. G., Karakoti, A. S., Seal, S. & Self, W. T. The role of cerium redox state in the SOD mimetic activity of nanoceria. Biomaterials 29, 2705–2709 (2008).
McGinnis, J. F. et al. Inhibition of reactive oxygen species and protection of mammalian cells. United States patent US20060246152 A1. 2 Nov 2006.
Walkey, C. et al. Catalytic properties and biomedical applications of cerium oxide nanoparticles. Environmental Science: Nano 2, 33–53 (2015).
Self, W. T., Bossy-wetzel, E., Seal, S. & Dowding, J. Neuronal protection by cerium oxide nanoparticles. United States patent US20,160,038,537. 20 Oct 2015.
Dowding, J. et al. Cerium oxide nanoparticles protect against Aβ-induced mitochondrial fragmentation and neuronal cell death. Cell Death & Differentiation 21, 1622–1632 (2014).
Sack, M. et al. Combination of conventional chemotherapeutics with redox-active cerium oxide nanoparticles–a novel aspect in cancer therapy. Molecular cancer therapeutics 13, 1740–1749 (2014).
Jana, S. K., Banerjee, P., Das, S., Seal, S. & Chaudhury, K. Redox-active nanoceria depolarize mitochondrial membrane of human colon cancer cells. Journal of nanoparticle research 16, 1–9 (2014).
Cai, X. et al. Nanoceria with Grp78/Bip produce enhanced inhibition of retinal degeneration in tubby mice. Investigative Ophthalmology & Visual Science 55, 4622–4622 (2014).
Alili, L. et al. Combined cytotoxic and anti-invasive properties of redox-active nanoparticles in tumor–stroma interactions. Biomaterials 32, 2918–2929 (2011).
Wason, M. S. et al. Sensitization of pancreatic cancer cells to radiation by cerium oxide nanoparticle-induced ROS production. Nanomedicine: Nanotechnology, Biology and Medicine 9, 558–569 (2013).
Das, S. et al. Cerium oxide nanoparticles: applications and prospects in nanomedicine. Nanomedicine 8, 1483–1508 (2013).
Ansari, A. A., Kaushik, A., Solanki, P. R. & Malhotra, B. D. Sol–gel derived nanoporous cerium oxide film for application to cholesterol biosensor. Electrochemistry Communications 10, 1246–1249, doi:10.1016/j.elecom.2008.06.003 (2008).
Saha, S. et al. Nanoporous cerium oxide thin film for glucose biosensor. Biosensors and Bioelectronics 24, 2040–2045, doi:10.1016/j.bios.2008.10.032 (2009).
Seal, S., Cho, H., Patil, S. & Mehta, A. Cerium oxide nanoparticle regenerative free radical sensor. United States patent US8172997 B2. 8 May 2012.
Allen J. Bard, L. R. F. Electrochemical Methods: Fundamentals and Applications. (Wiley, 2001).
Gerlache, M., Senturk, Z., Quarin, G. & Kauffmann, J.-M. Electrochemical behavior of H2O2 on gold. Electroanalysis 9, 1088–1092, doi:10.1002/elan.1140091411 (1997).
Sardesai, N. P., Andreescu, D. & Andreescu, S. Electroanalytical Evaluation of Antioxidant Activity of Cerium Oxide Nanoparticles by Nanoparticle Collisions at Microelectrodes. Journal of the American Chemical Society 135, 16770–16773, doi:10.1021/ja408087s (2013).
Neal, C. J., Das, S., Saraf, S., Tetard, L. & Seal, S. Self-Assembly of PEG-Coated Ceria Nanoparticles Shows Dependence on PEG Molecular Weight and Ageing. ChemPlusChem 80, 1680–1690, doi:10.1002/cplu.201500237 (2015).
Rees, N. V., Zhou, Y.-G. & Compton, R. G. Making contact: charge transfer during particle-electrode collisions. RSC Advances 2, 379–384, doi:10.1039/C2RA01100J (2012).
Kahk, J. M. et al. Electron transfer kinetics at single nanoparticles. Nano Today 7, 174–179, doi:10.1016/j.nantod.2012.04.005 (2012).
Sayle, T. X., Parker, S. C. & Sayle, D. C. Phys. Chem. Chem. Phys. 7, 2936 (2005).
Sharpe, E., Frasco, T., Andreescu, D. & Andreescu, S. Portable ceria nanoparticle-based assay for rapid detection of food antioxidants (NanoCerac). Analyst 138, 249–262 (2013).
Rivest, J. B. & Jain, P. K. Cation exchange on the nanoscale: an emerging technique for new material synthesis, device fabrication, and chemical sensing. Chemical Society Reviews 42, 89–96, doi:10.1039/C2CS35241A (2013).
Rupp, J. L. Ionic diffusion as a matter of lattice-strain for electroceramic thin films. Solid State Ionics 207, 1–13 (2012).
Deshpande, S., Patil, S., Kuchibhatla, S. V. & Seal, S. Size dependency variation in lattice parameter and valency states in nanocrystalline cerium oxide. Applied Physics Letters 87, 133113, doi:10.1063/1.2061873 (2005).
Murray, E. P., Tsai, T. & Barnett, S. A. A direct-methane fuel cell with a ceria-based anode. Nature 400, 649–651 (1999).
Barkam, S., Saraf, S. & Seal, S. Fabricated Micro-Nano Devices for In vivo and In vitro Biomedical Applications. Wiley Interdisciplinary Reviews: Nanomedicine and Nanobiotechnology 5, 544–568, doi:10.1002/wnan.1236 (2013).
Saraf, S. et al. Electrochemical study of nanoporous gold revealing anti-biofouling properties. RSC Advances 5, 46501–46508 (2015).
Karyakin, A. A. & Karyakina, E. E. Prussian Blue-based ‘artificial peroxidase’ as a transducer for hydrogen peroxide detection. Application to biosensors. Sensors and Actuators B: Chemical 57, 268–273, doi:10.1016/S0925-4005(99)00154-9 (1999).
Liu, S., Tian, J., Wang, L. & Sun, X. A method for the production of reduced graphene oxide using benzylamine as a reducing and stabilizing agent and its subsequent decoration with Ag nanoparticles for enzymeless hydrogen peroxide detection. Carbon 49, 3158–3164, doi:10.1016/j.carbon.2011.03.036 (2011).
Song, M.-J., Hwang, S. W. & Whang, D. Non-enzymatic electrochemical CuO nanoflowers sensor for hydrogen peroxide detection. Talanta 80, 1648–1652, doi:10.1016/j.talanta.2009.09.061 (2010).
Evans, S. A. G. et al. Detection of Hydrogen Peroxide at Mesoporous Platinum Microelectrodes. Analytical Chemistry 74, 1322–1326, doi:10.1021/ac011052p (2002).
Welch, C. M., Banks, C. E., Simm, A. O. & Compton, R. G. Silver nanoparticle assemblies supported on glassy-carbon electrodes for the electro-analytical detection of hydrogen peroxide. Analytical and Bioanalytical Chemistry 382, 12–21, doi:10.1007/s00216-005-3205-5 (2005).
He, S., Shi, W., Zhang, X., Li, J. & Huang, Y. beta-cyclodextrins-based inclusion complexes of CoFe(2)O(4) magnetic nanoparticles as catalyst for the luminol chemiluminescence system and their applications in hydrogen peroxide detection. Talanta 82, 377–383, doi:10.1016/j.talanta.2010.04.055 (2010).
Fiorito, P. A. & de Torresi, C. S. I. Hybrid nickel hexacyanoferrate/polypyrrole composite as mediator for hydrogen peroxide detection and its application in oxidase-based biosensors. Journal of Electroanalytical Chemistry 581, 31–37, doi:10.1016/j.jelechem.2005.01.039 (2005).
Shao, M. W., Shan, Y. Y., Wong, N. B. & Lee, S. T. Silicon Nanowire Sensors for Bioanalytical Applications: Glucose and Hydrogen Peroxide Detection. Advanced Functional Materials 15, 1478–1482, doi:10.1002/adfm.200500080 (2005).
Navas Dı́az, A., Ramos Peinado, M. C. & Torijas Minguez, M. C. Sol–gel horseradish peroxidase biosensor for hydrogen peroxide detection by chemiluminescence. Analytica Chimica Acta 363, 221–227, doi:10.1016/S0003-2670(98)00080-4 (1998).
Zhao, B. et al. Silver microspheres for application as hydrogen peroxide sensor. Electrochemistry Communications 11, 1707–1710, doi:10.1016/j.elecom.2009.06.035 (2009).
Huang, K.-J. et al. Direct electrochemistry of catalase at amine-functionalized graphene/gold nanoparticles composite film for hydrogen peroxide sensor. Electrochim. Acta 56, 2947–2953 (2011).
Song, Y., Cui, K., Wang, L. & Chen, S. The electrodeposition of Ag nanoparticles on a type I collagen-modified glassy carbon electrode and their applications as a hydrogen peroxide sensor. Nanotechnology 20, 105501 (2009).
Acknowledgements
The authors gratefully acknowledge partial support from National Science Foundation, University of Oklahoma/National Institutes for Health, and other related funding sources.
Author information
Authors and Affiliations
Contributions
C.N.: Experimental design, Manuscript preparation, Experiments. A.G.: Experiments, Manuscript preparation. S.B.: Experiments, Manuscript preparation. S.S.: Experimental design, Manuscript preparation. S.D.: Experimental design, Manuscript preparation. H.J.C.: Experimental design, Manuscript preparation. S.S.: Experimental design, Manuscript preparation.
Corresponding author
Ethics declarations
Competing Interests
The authors declare that they have no competing interests.
Additional information
Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Electronic supplementary material
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Neal, C.J., Gupta, A., Barkam, S. et al. Picomolar Detection of Hydrogen Peroxide using Enzyme-free Inorganic Nanoparticle-based Sensor. Sci Rep 7, 1324 (2017). https://doi.org/10.1038/s41598-017-01356-5
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-017-01356-5
This article is cited by
-
Bioengineered and biocompatible silver nanoparticles from Thalictrum foliolosum DC and their biomedical applications
Clean Technologies and Environmental Policy (2022)
-
Simple and fast colorimetric and electrochemical methods for the ultrasensitive detection of glucose
Analytical and Bioanalytical Chemistry (2021)
-
A screen-printed electrochemical sensing platform surface modified with nanostructured ytterbium oxide nanoplates facilitating the electroanalytical sensing of the analgesic drugs acetaminophen and tramadol
Microchimica Acta (2020)
-
Nonenzymatic sensing of hydrogen peroxide using a glassy carbon electrode modified with graphene oxide, a polyamidoamine dendrimer, and with polyaniline deposited by the Fenton reaction
Microchimica Acta (2018)