Introduction

Chemical Exchange Saturation Transfer (CEST) MRI is a sensitive imaging technique for detecting compounds containing exchangeable protons1,2,3. Such labile protons can be selectively saturated by a radiofrequency (RF) pulse and subsequently transfer the saturation to the bulk water signal via proton chemical exchange, resulting in substantial sensitivity enhancement. CEST imaging has been demonstrated in mapping low-concentration metabolites such as creatine4, glucose5, 6, glutamate7 and changes in microenvironment properties such as temperature8 and pH9,10,11, promising in a host of in vivo applications such as imaging of ischemic stroke12,13,14,15 and tumor16,17,18,19,20,21.

Quantitative CEST MRI is typically performed by analyzing the Z-spectrum acquired through sweeping RF saturation around the bulk water resonance, offset by offset. In vivo CEST quantification remains challenging due to concomitant effects such as RF spillover (direct water saturation), semisolid macromolecular magnetization transfer (MT) and nuclear overhauser effects (NOE). As such, the conventional asymmetry analysis (MTRasym), which has been widely used to suppress spillover and MT effects, measures a mixed contribution. Hence, resolving individual contributions is necessary. To avoid asymmetric MT effect, a three-offset approach that subtracts the label image from the average of two boundary images that have an equal offset shift from the label image was proposed to quantify amide proton transfer (APT) and NOE effects22, 23. However, the linear assumption underlying the three offset method is oversimplified, which likely underestimates the APT and NOE effects. Recently, least-squares Z-spectral fitting approaches have been employed to resolve multi-pool contributions, including APT, spillover, MT and NOE18, 24, 25 or enzyme-responsive CEST agent26. For example, Heo et al. fitted wide-offset data with a super-Lorentzian lineshape to estimate the semisolid MT signal and quantified APT and NOE effects by subtracting the fitted MT signal from the Z-spectrum27, 28. Analytical studies confirmed that individual CEST effect, including the MT effect within a small range of frequency offsets, can be approximated by a Lorentzian line shape in a Z-spectrum29,30,31. Therefore, an alternative approach is to fit the Z-spectra at low irradiation powers using a multi-pool Lorentzian model29, 32, 33. The reliability of these approaches depends strongly on the signal-to-noise ratio (SNR), which may be compromised by spatiotemporal resolution. Moreover, conventional least-squares fitting is sensitive to the initial values and boundary values, which can lead to inaccurate fitting results, if not properly selected.

In this study, we proposed an Image Downsampling Expedited Adaptive Least-squares (IDEAL) fitting algorithm to improve the reliability of in vivo CEST MRI quantification. Figure 1a shows the flow chart of the proposed IDEAL fitting. Specifically, it uses globally averaged Z-spectrum for initial fitting, which are more reliable given the high SNR and relaxed boundary constraints. The initial fitting results are then used as initial values for subsequent fitting of substantially downsampled images. The resolution of downsampled images is increased iteratively and fitted with the fitting results from the previous downsampled images as renewed initial values until the desired image resolution is reached (Fig. 1b). We first evaluated the IDEAL fitting approach with conventional voxel-wise fitting in a CEST phantom superimposed with different levels of simulated noise. The fitting quality of both methods were assessed via coefficient of variation (COV, i.e., S.D./mean), contrast-to-noise ratio (CNR), goodness of fit and fitting speed. We then applied the IDEAL fitting in vivo, and quantified the complex CEST effects in a rat model of glioma, demonstrating the advantage of the proposed IDEAL fitting algorithm.

Figure 1
figure 1

(a) Flow chart of data processing steps of the Image Downsampling Expedited Adaptive Least-squares (IDEAL) fitting approach. (b) The intermediate fitting results of iteratively less downsampled images from a two-compartment CEST phantom.

Results

Phantom Study

Figure 1b illustrates the intermediate fitting results of iteratively less downsampled images from a two-compartment CEST phantom using the proposed IDEAL fitting approach. Figure 2 compares the proposed IDEAL fitting with conventional fitting in the CEST phantom. The same initial values and boundary values were used in conventional fitting and in the fitting of global Z-spectrum (Fig. 2a) for determination of initial values in the IDEAL fitting approach. The global-Z spectrum was obtained by averaging the Z-spectra of all voxels within the phantom so it had substantially higher SNR than that of individual voxel. Consequently, the fitted CEST peaks of the global Z-spectrum were similar in amplitude, offset and linewidth without (σ = 0) or with added noise (σ = 0.02 and 0.05). Without added noise, the fitted amide and creatine (Cr) amplitude maps using conventional fitting and IDEAL fitting were comparable (Fig. 2b). Both methods showed high R2 maps. However, significant amount of noise appeared in the amplitude maps obtained from the conventional fitting after Gaussian noise superposition, indicating it's more susceptible to SNR degradation than the proposed IDEAL fitting algorithm.

Figure 2
figure 2

Conventional voxel-wise multi-pool Lorentzian fitting versus Image Downsampling Expedited Adaptive Least-squares (IDEAL) fitting in the two-compartment phantom (left: 50 mM Creatine (Cr) and 100 mM nicotinamide (amide); right: 100 mM Cr and 50 mM amide) with different levels of Gaussian noise added. (a) Multi-pool Lorentzian fit of the global Z spectra at different noise levels to determine initial values for IDEAL fitting. The global Z spectrum was obtained by averaging the Z spectra of all voxels within the phantom. (b) Fitted amide and Cr maps using conventional fitting or IDEAL fitting. The corresponding R2 maps were shown.

The performance of the IDEAL fitting was further evaluated under varied noise level (Figs 3 and 4). No significant difference was found in the fitted amplitudes of amide and Cr peaks between conventional fitting and IDEAL in the absence of simulated noise, and the results were used as the reference for further comparison. For the conventional fitting, the derived amplitudes increasingly deviated from the reference as the simulated noise level increased (Fig 3b,c). In contrast, the IDEAL fitting provided much more stable results, showing smaller deviation from the reference (P < 0.0001, paired t-test) with smaller SDs (P < 0.0001, paired t-test). For both fitting methods, the coefficient of variation (COV) in the fitted amplitude maps increased with the added noise level (Fig. 4a). However, the COV using IDEAL fitting was generally less affected by the noise and it was significantly smaller than that of conventional fitting for σ > 0.055. The contrast-to-noise ratio (CNR) between the two vials diminished with increased noise (Fig. 4b), but the CNR from IDEAL fitting was significantly higher than that of conventional fitting (P = 0.029, paired t-test). The goodness of fit (R2) of the two fitting methods was not significantly different but both gradually decreased with increased noise level (Fig. 4c). Importantly, the total computing time using IDEAL fitting was substantially smaller than that of conventional fitting at different noise level (P < 0.0001, paired t-test).

Figure 3
figure 3

Comparison of fitted amplitudes from conventional fitting and IDEAL fitting under different noise level in (a) a phantom with two compartments containing different concentrations of amide and Cr. Fitted amplitudes of (b) amide and (c) Cr in each compartment was plotted as a function of standard deviation of added Gaussian noise (σ).

Figure 4
figure 4

Comparison of fitting quality of conventional fitting and IDEAL fitting in the phantom, in terms of (a) coefficient of variation (COV, i.e., S.D./mean) in the fitted amplitude maps, (b) contrast-to-noise ratio (CNR) between the two compartments in the fitted amide and Cr amplitude maps, (c) R2 as a function of noise level (σ), and (d) computing time. Paired Student's t-test was performed between the two methods.

Animal Study

We further applied the IDEAL fitting to quantify CEST MRI in a rat glioma model. Figure 5 shows the global Z-spectrum averaged from all voxels within the brain and it was fitted using a six-pool model. The fitting residual had no apparent peaks and was less than 0.26% over the frequency offset range. The fitting results were then used as the initial values for the iterative IDEAL fitting. Figure 6 shows the fitted amplitude, frequency offset and linewidth maps of each pool using both the conventional fitting and IDEAL fitting in a representative rat brain with glioma. The tumor appeared hyperintense in the fitted amide amplitude map using the IDEAL fitting (Fig. 6a) yet such contrast was less apparent and clear in the conventional fitting. Furthermore, the amine map using IDEAL fitting displayed a positive contrast which was not observed in the result from conventional fitting. For both fitting methods, water map showed relatively hyperintensity while MT maps displayed a pronounced signal reduction in the tumor region, as compared to the contralateral normal tissue. Whereas no apparent difference between the tumor and normal regions was found in NOE −3.5 ppm maps, the NOE −1.6 ppm map showed relatively hypointensity in the tumor region. All the amplitude maps fitted by IDEAL method appeared more homogeneous than those from conventional fitting. We also compared the CEST contrasts between the tumor and contralateral normal regions in all the animals (N = 8). Both methods showed a significantly higher APT signal (P < 0.001, paired t-test) and a strong negative MT contrast (P < 0.001, paired t-test) in the tumor. No significant change in NOE −3.5 ppm signal was found in the tumor (P = 0.16 and 0.69 for conventional and IDEAL fitting respectively, paired t-test). Interestingly, the contrast between tumor and normal regions at 2 ppm was significant using IDEAL fitting (P < 0.05, paired t-test) but not with conventional fitting (P = 0.20, paired t-test). Similarly, the IDEAL fitting revealed significant negative contrasts in the tumor in the NOE −1.6 ppm map (P < 0.01, paired t-test) which was not observed in the map from conventional fitting (P = 0.12, paired t-test). The fitted offset and linewidth maps were generally homogenous throughout the brain for both methods, but the results from conventional fitting were noisier (Fig. 6b,c).

Figure 5
figure 5

Multi-pool Lorentzian fit of the global Z spectra from a rat brain to determine initial values for IDEAL fitting, including saturation transfer effects from −3.5, −1.6, 2, 3.5 ppm as well as direct saturation and MT contributions.

Figure 6
figure 6

Fitted amplitude, frequency offset and linewidth maps of each pool using conventional fitting and IDEAL fitting in a representative rat brain with glioma.

Figure 7 compares the quality of IDEAL and conventional fitting methods in vivo in rat gliomas. The whole-brain COV in the fitted amplitude maps was significantly smaller using IDEAL fitting for all exchangeable pools (Fig. 7a). More importantly, IDEAL fitting provides substantially higher CNR in five out of the six pools (Fig. 7b). For all the gliomas studied (N = 8), the goodness of fit (R2) of the whole brain was significantly higher using IDEAL fitting (P < 0.001, paired t-test).

Figure 7
figure 7

Comparison of fitting quality of conventional fitting and IDEAL fitting in rat gliomas (N = 8), including (a) the coefficient of variation (COV, i.e., S.D./mean) of the whole brain, (b) contrast-to-noise ratio (CNR) between the normal brain and brain tumor, (c) R2 of the whole brain. Paired Student's t-test was performed between the two methods with *P < 0.05, **P < 0.01 and ***P < 0.001.

Discussion

In this study, we proposed a new fitting algorithm that harnesses the high SNR of downsampled images for iterative fitting and achieved reliable CEST MRI quantification. This is important because in vivo CEST effect is subtle, typically a few percent, with concomitant RF saturation effects that are often non-negligible. The SNR of CEST images can be typically improved by increasing the number of signal averages. However, this prolongs scan time, especially for Z-spectral acquisition. Alternatively, post-processing methods such as spatial smoothing and/or spectral interpolation have been used to achieve higher SNR before multi-pool Lorentzian fitting on a voxel basis34, 35. Our proposed IDEAL fitting approach combined spline interpolation and spatial downsampling to achieve higher SNR for iterative fitting. On the other hand, proper selection of initial values is critical for in vivo CEST fitting, particularly for cases of complex multi-component systems under suboptimal SNR. The proposed IDEAL fitting approach avoids arbitrary selection of initial values and minimizes operator bias, enabling automated and adaptive fitting for reliable estimation of CEST effects. We first evaluated the performance of IDEAL fitting in a CEST phantom. Overall, the IDEAL fitting results are of smaller COV, higher CNR and comparable goodness of fit at a faster fitting speed when compared to those of the conventional fitting. The fitted maps from the IDEAL method were generally less noisy, even with the raw CEST images plagued by superimposed noise, likely due to the good initial values determined from high SNR Z-spectra. The use of tightly constrained boundaries after initial fitting can minimize undesirable fluctuations in fitting results due to superimposed noise or poor SNR.

We further applied the IDEAL fitting to quantify the contributions from APT, amine, NOE and MT effects in a rat model of glioma. A substantially higher APT signal in the tumor was in line with the previous findings using APT imaging of glioma28, 36,37,38, likely attributable to elevated intracellular mobile proteins/peptides concentration39. Both methods showed a strong negative MT contrast in the tumor, consistent with the finding from quantitative MT40. In addition, no significant changes in NOE-3.5 ppm were found in the tumor, similar to the previous studies using similar irradiation powers28, 41, 42. Interestingly, the IDEAL fitting revealed a pronounced negative contrast in the tumor in the fitted amine (2 ppm) map which was not observed in the map from conventional fitting. The CEST effect at 2 ppm has been shown to correlate with the creatine level in brain tumor and change with tumor progression4, 43. We also found a significantly reduction in NOE-1.6 ppm, which was also observed in a recent CEST study of rat glioma at 9.4 T44. It has been suggested that this effect may originate from choline phospholipids and can be used as a new biomarker for the detection of brain tumor. Indeed, the CNR between the tumor and normal region in the amine and NOE-1.6 ppm map was much smaller than 1 using conventional method. Therefore, the IDEAL fitting is advantageous in revealing such changes under suboptimal SNR.

Although it has been shown that both labile proton concentration and exchange rate can be simultaneously determined from quantitative CEST (qCEST) analysis, its in vivo application is somewhat cumbersome due to the presence of complex multiple exchangeable compartments. It is worthwhile to point out that Lorentzian decoupling provides reasonable CEST quantification, particularly under the case of relatively weak RF saturation where different CEST peaks can be reliably detected (Fig. S2). The use of strong saturation levels may enhance the CEST effects but it also leads to increased RF spillover and broadened peaks that may substantially overlap with one another, resulting in less reliable decoupling results. Because the typical exchange rates from amide protons, MT and NOE components for in vivo CEST MRI are relatively slow, and therefore, it is advantageous to choose a relatively weak RF irradiation level for both experimental optimization and quantification. Moreover, the proposed IDEAL method takes advantage of the high SNR of global Z-spectrum so the peaks of CEST effects can be reliably identified. The proposed IDEAL approach may be further combined with qCEST analysis. Decoupling the complex CEST contrast is highly desired for more accurate quantification using qCEST analysis such as ratiometric45 or omega plot approaches46, 47, which will be investigated in our future work. In this study, routine T1 and T2 maps were acquired to identify the tumors (Fig. S1, supplementary information). Indeed, significantly prolonged T1 and reduced T2 were found in the tumor region (Table S1). In the future, it is worthwhile to evaluate the correlation between relaxation times and decoupled CEST contrasts in gliomas, which may assist in the optimization of quantitative CEST for cancer imaging. Additionally, we would like to point out the limitation of using R2 to assess the goodness of fit, which may not faithfully reflect the fitting quality, especially with a multi-pool model at suboptimal SNR. In the case of conventional fitting, relatively high R2 can be achieved through relaxed boundary constraints but the fitting results may substantially deviate from those determined under excellent SNR. In addition, the loose boundary constraints may likely lead to longer computing time as more iterative steps were taken to solve the ‘best’ fit. One limitation of the IDEAL method is that image downsampling will introduce aliasing while upscaling the fitted maps may lead to reduced contrast and produce staircase artifacts around edges. It is necessary to choose anti-aliasing algorithm and edge-directed interpolation to preserve the edges after scaling.

Recently, multi-pool Lorentzian fitting has been increasingly employed to isolate the APT and NOE effect from the spillover and MT confounded Z-spectrum27,28,29, 32, 33. However, such post-processing routines either require acquisition of Z-spectra of wide range of frequency offsets or are limited to cases of prominent APT/NOE effects. On the other hand, the SNR of CEST Z-spectral images can be compromised due to high spatialtemporal resolution and/or the need to obtain densly-sampled Z-spectra quickly. As such, the SNR may be suboptimal for conventional fitting routine. Under such conditions, the proposed IDEAL fitting facilitates CEST quantification, quickly and reliably. Moreover, the IDEAL fitting can be applied to noise prone MRI dataset with a fourth dimension, such as blood oxygenation level dependent (BOLD) functional MRI, dynamic contrast-enhanced (DCE) MRI, and dynamic susceptibility contrast (DSC) MRI, etc.

In summary, the proposed IDEAL fitting method quantifies CEST images based on initial values from multi-pool Lorentzian fitting of iteratively less downsampled images until quantitative CEST maps of desired resolution are obtained. It allows reliable fitting at a faster fitting speed, and is less susceptible to suboptimal SNR than the conventional method. The CEST maps fitted using the IDEAL method showed smaller COV and higher CNR, which are desirable for in vivo CEST quantification. The IDEAL fitting was applied to quantify CEST effects in rat gliomas and the results showed significant changes in APT and MT effects in tumors similar to those of conventional method but with substantially higher CNRs. More importantly, it revealed pronounced negative contrasts in tumors in the fitted CEST maps at 2 ppm and −1.6 ppm which were not found using conventional method due to strong variation in its fitting results. These CEST contrasts may reflect changes in creatine level and NOE effects, warranting further investigation of their potentials in tumor detection, grading and treatment. It is anticipated that the proposed IDEAL fitting can be generalized to quantify MRI dataset where SNR is suboptimal.

Materials and Methods

Phantom

We prepared an in vitro CEST phantom with two vials containing different concentrations of mixed creatine and nicotinamide in CuSO4-doped (1.5 mM) phosphate buffered solution (Sigma Aldrich, St Louis, MO). The concentration of creatine in the two vials was 50 mM and 100 mM and that of nicotinamide was 100 mM and 50 mM; pH was titrated to 7.0 (EuTech Instrument, Singapore). The vials were then sealed and inserted into a 50 ml falcon tube filled with 1.5% low gelling-point agarose.

Tumor Model

Animal experiments were performed in accordance with institutional guidelines, as approved by the Institutional Animal Care and Use Committees (IACUC), Massachusetts General Hospital. 2 × 105 cells of the non-infiltrating D74-rat glioma model48, 49 were injected into the right frontal lobe of adult male Fischer 344 rats (N = 8), as previously described50. The animals were imaged 11–13 days after tumor implantation.

MRI

MRI scans were performed on a 4.7 Tesla small-bore scanner (Bruker Biospec, Ettlingen, Germany). For the phantom study, CEST MRI was obtained with single-slice, single-shot echo planar imaging (EPI) (field of view (FOV) = 52 × 52 mm2, matrix = 96 × 96, slice thickness = 10 mm). Z-spectrum was acquired from −5 ppm to 5 ppm with intervals of 0.125 ppm and RF irradiation power level of 1 µT. The repetition time (TR)/saturation time (TS)/echo time (TE) was 10 s/5 s/45 ms, number of average (NSA) = 1, and the total scan time was 13 min 40 s. For the rodent study, multi-slice MRI (FOV = 20 × 20 mm2, matrix = 64 × 64, 5 slices, slice thickness/gap = 1.8/0.2 mm) was acquired with single-shot EPI. We obtained Z-spectrum from −6 ppm to 6 ppm with intervals of 0.25 ppm and RF irradiation power level of 0.75 µT, TR/TS/TE = 10 s/5 s/15 ms, NSA = 2 and scan time = 8 min 20 s. In addition, T1-weighted images were acquired with seven inversion delays ranging from 250 ms to 3,000 ms (TR/TE = 6,500/28 ms, NSA = 4); T2-weigthed images were obtained with two TE of 30 and 100 ms (TR = 3,250 ms, NSA = 16)51.

Data Analysis

Data were processed in MATLAB (MathWorks, Natick, MA). T1w and T2w parametric maps were obtained with least-squares mono-exponential fitting of the signal intensities as a function of inversion time and TE, respectively. Z-spectra (I) were interpolated by smoothing splines, corrected for field inhomogeneity using a WASSR map and normalized by the signal without RF irradiation (I0)52, 53. For the conventional fitting method, multi-pool Lorentzian fitting of the Z-spectra on a voxel basis was applied to estimate the CEST effects from different pools4, 24. Briefly, the Z-spectrum was fitted as the sum of multiple Lorentzian functions with the following equation

$$1-\frac{I}{{I}_{0}}=\sum _{i=1}^{N}\frac{{A}_{i}}{1+4{(\frac{\omega -{\omega }_{i}}{{\sigma }_{i}})}^{2}}$$
(1)

where ω is the frequency offset from the water resonance, A i , ω i and σ i are the amplitude, frequency offset and linewidth of the CEST peak for the ith proton pool, respectively. In the CEST phantom, we employed a five-pool Lorentzian model, including water (0 ppm), magnetization transfer (MT, −2 ppm), amide (3.5 ppm), creatine (1.9 ppm) and hydroxyl (-OH, 1 ppm). Note the frequency offset of each pool was used as initial values for fitting. For the in vivo study of rat gliomas, a six-pool Lorentzian model of water (0 ppm), MT (−2 ppm), amide (3.5 ppm), amine (2 ppm) and Nuclear Overhauser enhancement (NOE) effects at 3.5 ppm and 1.6 ppm upfield from water was used44, 54.

The conventional fitting was constrained by bounds between 10% and 10 times of the initial values for amplitude and linewidth, and ±20% of the corresponding linewidth for frequency offset of each proton pool. Figure 1 shows the flow chart of IDEAL fitting. Briefly, a global Z-spectrum was first obtained by averaging the Z-spectra from all voxels within the mask. Multi-pool Lorentzian fitting of the global Z-spectrum with the same loosely constrained bounds as the conventional fitting to determine initial values for subsequent fine fitting. The field inhomogeneity-corrected CEST images were downsampled to 4 × 4 for voxel-wise multi-pool Lorentzian fitting, with the initial values of each voxel determined by the fitted values of the global Z-spectrum and tightly constrained bounds of ±10% the initial values for amplitude and linewidth, and ±5% of the corresponding linewidth for frequency offset. The same procedure was repeated sequentially for the CEST images downsampled to 8 × 8, 16 × 16, 32 × 32, etc., till the original image size of 96 × 96 or 64 × 64, with the initial values of each voxel determined by interpolating the fitted amplitude/linewidth/offset maps of the last downsampled images. For both fitting methods, the quality of fitting was evaluated by (1) coefficient of variation (COV, i.e., standard deviation/mean) within the mask in the fitted amplitude maps, (2) contrast-to-noise ratio (CNR) in the fitted amplitude maps between the two vials in the phantom or between the normal and tumor regions calculated by \(CNR=\frac{| {S}_{1}-{S}_{2}| }{\sqrt{({\sigma }_{1}^{2}+{\sigma }_{2}^{2})}}\), where S 1,2 are the mean values for the two regions-of-interest (ROIs) respectively and σ 1,2 are their standard deviations, and (3) goodness of fit (R2) maps. The ROIs of tumor tissues were defined based on the distinct information from T1w and T2w maps and mirrored to the contralateral hemisphere for the ROIs of normal tissues (Fig. S1). To evaluate the performance of the fitting methods under noise, different levels of Gaussian noise with σ ranging from 0.005 to 0.1, were added to the original phantom data to test the performance of both fitting algorithms.