Abstract
This data descriptor describes the Roessingh Research & Development-MyLeg database for activity prediction (MyPredict), containing three data sets. These data sets contain data from 55 able-bodied subjects, mean age 24 ± 2 years, measured in 85 measurement sessions. Measurement sessions consisted of trials containing sitting, standing, overground walking, stair ascent, stair descent, ramp ascent, ramp descent, walking on uneven terrain and walking in simulated confined spaces. Subjects were measured using eight inertial measurement units in combination with different types of sEMG. Recorded kinematics consisted of joint angles, sensor accelerations, angular velocity, orientation and virtual marker positions. sEMG was recorded using bipolar sEMG, multi-array sEMG or a combination of both. All data showed excellent correlation with other online available data sets. The data reported in this descriptor forms a solid basis for research into myoelectric pattern recognition, myoelectric control development and electromyography to be used in data-driven applications.
Similar content being viewed by others
Background & Summary
Human motor intent recognition based on surface electromyography (sEMG) could provide a more intuitive control in applications such as prostheses, exoskeletons or wheelchairs. sEMG is a non-invasive technique and therefore well suited to realize intent recognition. However, analysis of sEMG is complex due to its stochastic nature. Robustness of a myoelectric system is important, but due to limiting factors in sEMG such as muscle fatigue, electrode shift and inter-subject variability, this is difficult to realize1. To capture this variability, large amounts of data are necessary. The sharing and availability of data is also necessary if the field moves towards more big data applications, such as deep learning. Deep learning shows the promise of reaching better performing and more general applicable algorithms compared to more traditional methods developed on small data sets. The downside of these data-driven approaches is that large amounts of data are necessary. Therefore, it is important for the myoelectric control research community to share sEMG related data1.
sEMG collection has become easier over time and more and more data sets containing sEMG are made publicly available, especially in the upper extremity. In the upper extremity sEMG control research has been around for decades and myoelectric control is making its way slowly to the lower limb2,3. The limited amount of research into lower limb myoelectric control is one of the main reasons why databases containing sEMG and kinematics of the lower limb are limited. Fortunately, in recent years the amount of research into myoelectric control grows and more data becomes available3,4,5,6,7,8,9. For instance Hu et al.6 presented a benchmark data set containing sEMG and kinematics measured with wearables collected during free transitioning of various gait-related activities in 10 able-bodied subjects. Camargo et al.7 measured 22 able-bodied subjects during gait-related activities such as walking, stair climbing and ramp walking. Lencioni et al.9 created a database containing 50 able-bodied subjects, performing gait-related activities, such as walking, stair walking and walking on toes and heels. These studies provide valuable data sets for the research community to use, to gain more insight into human mechanics of the lower limb and also move the field towards data-driven applications.
Important to note is that in most of these data sets the subjects did not transition freely from one activity to the next, except for the database by Hu et al.6. Data of these free transitions are required for a more realistic data set, closely matching a daily life setting. Realistic data is necessary for developing methods that can be used in home environments and contain variability that can be expected during daily use. Next to that, no database contained multi-array sEMG, although these grids of electrodes could give more meaningful insight into human motor function and enables more complex analysis methods1,10.
In this work we present the Roessingh Research & Development-MyLeg database for activity prediction (MyPredict). The general aim of this database is to promote research in data-driven intent recognition strategies and activity prediction strategies in the lower-limb using electromyography and to promote research and development in the area of multi-array sEMG in the lower limb. The database contains three data sets, each containing kinematics and sEMG from able-bodied subjects. In total 55 subjects participated over 85 measurement sessions. Each data set contained a different sEMG measuring protocol containing either traditional bipolar sEMG or multi-array sEMG or a combination of both. In these data sets the subjects transitioned freely from one activity to the next, providing challenging data sets for activity recognition and providing the possibility to investigate human kinematics and sEMG during gait-related activities. It should be kept in mind that this database consists of young able-bodied individuals. However, this database might provide a meaningful starting point for analyses into for instance activity recognition during gait-related activities and analyses into transition periods between two activities. Parts of these data sets were used in earlier work11,12, but this is the first time the data becomes publicly available.
Methods
Materials
In each data set lower body kinematics were collected using an MVN Link suit (Xsens, Enschede, The Netherlands), which uses eight inertial measurement units (IMUs) to reconstruct lower body movement at 240 Hz. IMUs were placed on the feet, lower legs, upper legs, pelvis and sternum. Details on the exact anatomical placement of IMUs are available in the documentation provided by Xsens13. Recorded kinematics were 3D acceleration and angular velocity per sensor, 3D reconstructed lumbar, pelvic, hip, knee and ankle angle and 3D virtual marker positions. The acceleration in the data set is so-called sensor-free acceleration, which means that the gravity component is subtracted. sEMG was recorded using three measurement systems and four different configurations were used, which are outlined below. Bipolar sEMG placement was done according to SENIAM guidelines14. An overview of the used measurement systems per dataset is shown in Table 1. The sensor locations are indicated in Fig. 2. Kinematics collected by the MVN link suit and the sEMG collected by the measurement systems were time synchronized and resampled to 1000 Hz. Synchronization between various measurement systems was performed using a validated synchronization method based on acceleration cross-correlation15. Marker positions were resampled to 100 Hz to reduce file size.
The used software for Xsens recordings was MVN Analyze v201913.
MyPredict 1
MyPredict 1 only contained bipolar sEMG. Bipolar sEMG was collected for MyPredict 1 using Trigno electrodes (Delsys, Boston, US) at a sample frequency of 1000 Hz. The measured muscles were the gluteus maximus (Gmax), rectus femoris (RF), vastus lateralis (VL), biceps femoris (BF), semitendinosus (ST), tibialis anterior (TA) and gastrocnemius medialis (GM) and the gluteus medius (Gmed). sEMG acquisition software was a custom MATLAB script using MATLAB 2017a16.
MyPredict 2
MyPredict 2 only contained multi-array sEMG. Multi-array sEMG signals for MyPredict 2 were recorded using the Sessantaquattro (Bioelettronica, Turin, Italy) with two sEMG grids (GR10MM0804) in a 4 × 8 configuration and an inter-electrode distance of 10 mm at a sample frequency of 2000Hz, see Fig. 1A. The software for multi-array sEMG acquisition was OTBiolab+ v117.
MyPredict 3
MyPredict 3 contained multi-array sEMG and bipolar sEMG. Bipolar sEMG for MyPredict 3 was acquired using the Wave electrodes (Cometa Systems, Bareggio, Italy) at a sampling frequency of 2000 Hz. The measured muscles using bipolar sEMG were the Gmax, RF, VL, BF, ST, TA, GM and the adductor magnus (AM). Multi-array sEMG was recorded with the Sessantaquattro (Bioelettronica, Turin, Italy) at a sampling frequency of 2000Hz and a custom-made grid of 4 × 16 electrodes with an interelectrode distance of approximately 20 mm. The grid covered the upper leg, spanning from the vastus lateralis to the aductor magnus and ending at the biceps femoris at the back, see also Fig. 1B. The software for multi-array sEMG acquisition was OTBiolab+ v117 and the software for bipolar sEMG acquisition was sEMG and Motion tools v718.
Protocols
Ethical statement
The data collection protocols were reviewed and approved by Medical research Ethics Committees United (MEC-U) Nieuwegein, the Netherlands, with trial number NL67247.044.18. The participants provided their written informed consent before inclusion in the studies.
MyPredict 1
10 able-bodied subjects (sex: 7 m, 3 f; age: 24 ± 2 years; weight: 77 ± 10 kg; height: 183 ± 9 cm) participated in this part of the study. Measurements were conducted at the Wearable Robotics Lab of the University of Twente, using obstacles constructed for the Cybathlon by the Department of Biomechanical Engineering. Obstacles used were the stairs (rise 17 cm, run 28 cm), ramp with two different slopes (15 and 20 degrees) and uneven terrain consisting of stepping stones on a surface, see also Fig. 3. Forty trials were conducted per subject. A trial consisted of sitting, standing, walking, stair ascent, walking, stair descent, walking, ramp ascent, walking, ramp descent, walking, walking on uneven terrain, walking in confined spaces, walking, standing and sitting. Confined spaces consisted of the subject taking small steps in all directions, i.e. forwards, backwards, sidesteps to left or right, diagonally forwards, backwards to either left or right. Subjects walked at their own preferred speed and after ten trials a small break was administered to avoid fatigue and check sensor placement. Each trial had a duration of around 1.5 minutes. Total measurement time including subject preparation, sensor placement and calibration was around two hours.
MyPredict 2
35 able-bodied subjects (sex: 14 m, 21 f; age: 23 ± 2 years; weight: 73 ± 11 kg; height: 179 ± 9 cm) participated in this part of the study. To have more life-like data, measurements were conducted partly in a lab, but also outside. All measurements took place in and around Roessingh Research & Development, Enschede, The Netherlands. Each subject performed five types of trials in the same order: [noitemsep,topsep = 0 pt]
-
Uneven terrain I A trial consisted of sitting on a bench, standing up, walking on level ground, walking on grass, standing still and walking back and sitting down. See also Fig. 4A.
-
Stairs Subject sat on a stair, stood up, walked to the stairs, ascended two flights of stairs, one consisting of eleven steps, the other of nine steps. Hereafter the subject stood still, turned around and descended the stairs, walked to the chair and sat down again.
-
Ramp The trial started with ascending a staircase with seven steps, reaching a plateau and descending a ramp (10 degrees) which continued into a steeper ramp (15 degrees) after three meters. The subject stood still at the end of the ramp, turned around and ascended the ramp. Hereafter the subject descended on the stairs and turned around to start the trial again. See also Fig. 4B.
-
Uneven terrain II This path consisted of uneven terrains found in the street. First the subject needed to come over a speed bump and hereafter walk on level ground towards the first type of cobblestones. This terrain consisted of small square stones which were slightly uneven. The subject crossed these cobblestones and walked onto the cobblestones consisting of unevenly laid Belgian blocks. After passing these cobblestones, the subject turned around and walked back over all types of terrains and repeated the trial. See also Fig. 4C.
-
Confined spaces The subject lay on a bed, stood up and walked towards confined spaces set-up. The subject took small steps in all directions, i.e. forwards, backwards, sidesteps to left or right, diagonally forwards, backwards to either left or right.
Between the trials the subject walked to each location and this data were recorded as well. Each trial was conducted ten times, with a total measurement time of around two hours, including subject preparation, sensor placement and calibration.
MyPredict 3
10 able-bodied subjects (sex: 4 m, 6 f; age: 24 ± 2 years; weight: 71 ± 9 kg; height: 174 ± 6 cm) participated in this part of the study. Data were collected at Roessingh Research & Development, Enschede, the Netherlands. Each subject was measured four times: three measurements were conducted on three subsequent days on day 1, 2 and 3 and the last measurement was three days later on day 7. The subjects were measured during the same time slot on each day. Each measurement included the same activities. Before each measurement the maximal voluntary contraction of each muscle was measured to be used for sEMG normalization.
The subjects were asked to perform a circuit of activities, including level-ground walking, stair ascent/descent (rise 20 cm, run 20 cm), ramp ascent/descent (10 degrees), sit-stand motions and non-weight-bearing activities on a stool. The subject had to sit on a stool and lift one leg off the ground (knee approximately 90 degrees). Then, the subject had to fully extend its knee while keeping its foot perpendicular to its lower leg. After, the subject performed maximal plantar flexion of the ankle, followed by maximal dorsiflexion. The knee was then brought back to a knee angle of approximately 90 degrees. Then, only knee extension and flexion needed to be performed. Lastly, only ankle plantar- and dorsiflexion needed to be performed while keeping the knee angle at 90 degrees. After, the foot was set down on the ground and the routine was repeated with the other leg. See also Fig. 5A. Hereafter the subject stood up, walked, ascended the stairs, walked, descended the ramp, walked, turned around, walked back to the ramp, ascended the ramp, walked, descended the stairs, walked and sat down again, see also Fig. 5B and 5C. This circuit was performed twenty times. Then, the routine was slightly changed for another twenty circuits: the subject had to first perform ankle plantar- and dorsiflexion, then the combination of both knee and ankle, and finish off with only knee extension and flexion. Remaining activities did not change in order. Total measurement time including subject preparation, sensor placement and calibration was around three hours per measurement day.
Maximum voluntary contraction for sEMG normalization
To normalize sEMG we recorded a maximum voluntary contraction (MVC) as well, which is based on the recommendations by Rutherford et al.19. The main difference is that we performed the contractions while standing instead of sitting. These MVCs were recorded for the bipolar sEMG of MyPredict 1 and MyPredict 3. No MVCs were recorded during the MyPredict 2 measurements. During the MVCs the subject was standing upright, using a wall or pole for balance and was asked to perform the following exercises, for a duration of five seconds:
-
RF-VL: The hip and knee were flexed to approximately 90 degrees. The observer placed its hands on the anterior side of the lower leg, just above the ankle, and applied resistance. The subject tried to extend his or her knee, against the resistance of the observer, keeping the upper leg in the same position.
-
BF-ST: The same initial setup as RF-VL. The observer placed a hand on the posterior side of lower leg, just above the ankle, and applied resistance.
-
AM: One foot was lifted off the ground. The knee was fully extended and the observer placed hands just above the knee, on the medial side of the leg. The subject tried to pull his or her leg medially to the other leg whilst the observer exerted lateral resistance.
-
Gmed: One foot was lifted off the ground. The knee was fully extended and the observer placed hands just above the knee, on the lateral side of the leg. The subject tried to push his or her leg laterally to the other leg whilst the observer exerted resistance.
-
Gmax: One foot was lifted off the ground and the knee was fully extended. The observer placed his or her hands just below the knee, on the anterior side of the lower leg. The subject performed hip extension against the resistance.
-
TA: The hip and knee were flexed to approximately 90 degrees. The observer places its hands on top of the toes. The subject performed dorsiflexion.
-
GM: Subject flexes its hip and knee to approximately 90 degrees. The observer places its hands under the toes. The subject performed plantar flexion.
It is important to keep in mind that no standard exist for performing MVCs20 and many possible ways of normalizing exist. In hindsight these MVCs could have been performed differently, preferably while the subject was seated or laying down. sEMG in this work was normalized using the peak dynamic method, similar to Bovi et al.5. The advantage of this method is that it does not require additional procedures and could also be used for non-able-bodied subjects.
Data Records
Data are stored in the 4TU repository available at https://doi.org/10.4121/2041872021. For each subject a separate HDF5 file22 was created. These files contain the measurement moment named ‘Day_X’ with X the number of the measurement moment. Inside these measurement moments there are files called ‘Trial_YY’, with YY the trial number, containing the different data types and ‘MVC’ containing the sEMG maximum voluntary contractions of each measurement moment. Note that only MyPredict 3 contains multiple measurement moments per subject.
The different data types are acceleration (Acc), angular velocity (Gyr), joint angles (Ang), Orientation (Ori) and electromyography (EMG). Inside each file there are trials containing data arrays with the corresponding data. Data arrays are named as follows: Type_Side_Loc. Type is one of the six data types, Loc is the location of the sensor and Side is the side of the location, either Left, Right or empty. For example Ang_Right_Knee contains the 3D joint angles of the knee, Gyr_Pelvis contains the 3D angular velocity of the pelvis IMU and EMG_Left_VL contains the sEMG data of the left vastus lateralis. Orientation is the orientation of the pelvis in space, expressed in Euler angles. Separate data types are ‘Labels’, which contains manual placed activity labels for each timestamp and ‘Time’ which indicates the timestamps per file. Marker data (Mrk) are stored in a separate group, ‘Markers’ with their own ‘Time’ array, as they have a different sample frequency (100 Hz) compared to the other data types (1000 Hz). An overview of all data types and locations is shown in Table 2.
The metadata of the subjects as shown in Table 1 is stored in the HDF5 files as well. These are height, weight and age of the subject during the measurement.
Technical Validation
To validate the quality of our data sets we investigated the gait cycle averages for the gait-related activities, as shown in Fig. 6 for joint angles and in Fig. 7 for sEMG. Initial contacts were determined using the sagittal angular velocity of the shank, as described by Maqbool et al.23. Hip flexion, knee flexion and ankle dorsiflexion are defined as a positive value in Fig. 6. sEMG was normalized using the peak dynamic method24, similar to Bovi et al.5. Per measurement session the maximum activation during overground walking was determined and this value was used for normalization.
Comparison with other data sets
We compared our data with the data set described by Bovi et al.5, Camargo et al.7 and Hu et al.6. Kinematics were measured using the MVN Link suit by Xsens (Enschede, The Netherlands). Xsens have shown to be capable of measuring human kinematics with excellent correlation compared with optical motion trackers13,25. In Fig. 8 average joint angles are shown for overground walking of the different data sets. No data was collected by Hu et al.6 for the hip joint. Correlation coefficients for the hip flexion/extension angle were 0.99 with Bovi et al.5 and 0.98 with Camargo et al.7. For knee flexion/extension angle the correlation coefficients were 0.99, 0.94, 0.95 compared with Bovi et al.5, Camargo et al.7 and Hu et al.6 respectively. For ankle plantar/dorsiflexion the correlation coefficients were 0.96, 0.88 and 0.72 compared with Bovi et al.5, Camargo et al.7 and Hu et al.6 respectively. Note that there is a offset between the ankle angle measured by Bovi et al.5 due to a different definition for the ankle angle. The joint angles in this work show excellent correlation with joint angles measured using an optical motion tracking system. Next to that, the hip and knee angle show excellent correlation compared with wearable motion tracking and strong correlation for the ankle.
For sEMG the correlation coefficient per muscle can be found in Table 3. It can be seen that sEMG shows excellent correlation with the online available data sets as well. These correlations were 0.86–0.95 compared with Bovi et al.5, 0.72–0.98 compared with Camargo et al.7 and 0.82–0.96 compared with Hu et al.6.
Limitations
Although this data set contains data to investigate differences between EMG types and activity recognition strategies, it should be kept in mind that the data was collected only with able-bodied young individuals. As Bovi et al.5 showed, there are kinematic differences between young and older adults. Another limitation is that kinematics were collected an IMU-based motion capture system, which is not considered to be the golden standard for motion tracking. Optical motion tracking in the lab is regarded as the most reliable way of measuring kinematics, although studies have shown that IMU tracking can be as accurate as optical motion tracking13,25. In our technical validation we have also showed excellent correlation with measurements conducted with optical motion capture systems. Next to that, the major advantage of using an IMU-based motion capture system is the possibility to measure subjects while transitioning freely from one activity to the next and also outside of the lab, which were for us some of the main reasons to use an IMU-based motion capture system. Another limitation of this study is the absence of force related data, such as data from force plates. This data set can therefore not be used to estimate full-body kinetics during gait-related activities.
Code availability
The scripts that facilitate re-use of the data can be found in the GitHub repository https://github.com/Rvs94/MyPredict. These scripts were developed and written in Python 3.9. All required software packages are open-source and available online.
References
Phinyomark, A. & Scheme, E. EMG Pattern Recognition in the Era of Big Data and Deep Learning. Big Data and Cognitive Computing 2, 21, https://doi.org/10.3390/bdcc2030021 (2018).
Hargrove, L. J., Simon, A. M., Lipschutz, R., Finucane, S. B. & Kuiken, T. A. Non-weight-bearing neural control of a powered transfemoral prosthesis. Journal of neuroengineering and rehabilitation 10, 1–11 (2013).
Windrich, M., Grimmer, M., Christ, O., Rinderknecht, S. & Beckerle, P. Active lower limb prosthetics: a systematic review of design issues and solutions. Biomedical engineering online 15, 5–19 (2016).
Labarrière, F. et al. Machine learning approaches for activity recognition and/or activity prediction in locomotion assistive devices—a systematic review. Sensors 20, 6345 (2020).
Bovi, G., Rabuffetti, M., Mazzoleni, P. & Ferrarin, M. A multiple-task gait analysis approach: kinematic, kinetic and emg reference data for healthy young and adult subjects. Gait & posture 33, 6–13 (2011).
Hu, B., Rouse, E. & Hargrove, L. Benchmark Datasets for Bilateral Lower-Limb Neuromechanical Signals from Wearable Sensors during Unassisted Locomotion in Able-Bodied Individuals. Frontiers in Robotics and AI 5, 1–5, https://doi.org/10.3389/frobt.2018.00014 (2018).
Camargo, J., Ramanathan, A., Flanagan, W. & Young, A. A comprehensive, open-source dataset of lower limb biomechanics in multiple conditions of stairs, ramps, and level-ground ambulation and transitions. Journal of Biomechanics 119, 110320 (2021).
Moreira, L., Figueiredo, J., Fonseca, P., Vilas-Boas, J. P. & Santos, C. P. Lower limb kinematic, kinetic, and emg data from young healthy humans during walking at controlled speeds. Scientific Data 8, 1–11 (2021).
Lencioni, T., Carpinella, I., Rabuffetti, M., Marzegan, A. & Ferrarin, M. Human kinematic, kinetic and emg data during different walking and stair ascending and descending tasks. Scientific data 6, 1–10 (2019).
Fleming, A. et al. Myoelectric control of robotic lower limb prostheses: a review of electromyography interfaces, control paradigms, challenges and future directions. Journal of neural engineering (2021).
Schulte, R. V., Prinsen, E. C., Hermens, H. J. & Buurke, J. H. Genetic algorithm for feature selection in lower limb pattern recognition. Frontiers in Robotics and AI 324 (2021).
Schulte, R. V., Zondag, M., Buurke, J. H. & Prinsen, E. C. Multi-day emg-based knee joint torque estimation using hybrid neuromusculoskeletal modelling and convolutional neural networks. Frontiers in Robotics and AI 107 (2022).
Schepers, M. et al. Xsens mvn: Consistent tracking of human motion using inertial sensing. Xsens Technol 1 (2018).
Hermens, H. J. et al. SENIAM - Deliverable 8 - European Recommendations for Surface ElectroMyoGraphy Chapter. 8–11 (1999).
Schulte, R. V., Prinsen, E. C., Schaake, L. & Buurke, J. H. Synchronization of wearable motion capture and emg measurement systems. In 2022 International Conference on Rehabilitation Robotics (ICORR), 1–6 (IEEE, 2022).
MATLAB. version R2017a (The MathWorks Inc., Natick, Massachusetts, 2017).
OT Bioelettronica. OTBiolab+. https://www.otbioelettronica.it/ (2022).
Cometa Systems. EMG and Motion tools. https://www.cometasystems.com/products/emg-and-motion-tools (2022).
Rutherford, D. J., Hubley-Kozey, C. L. & Stanish, W. D. Maximal voluntary isometric contraction exercises: a methodological investigation in moderate knee osteoarthritis. Journal of Electromyography and Kinesiology 21, 154–160 (2011).
Halaki, M. & Ginn, K. Normalization of emg signals: to normalize or not to normalize and what to normalize to. Computational intelligence in electromyography analysis-a perspective on current applications and future challenges 175–194 (2012).
Schulte, R. V. et al. Roessingh Research & Development-MyLeg database for activity prediction (MyPredict). 4TU.ResearchData https://doi.org/10.4121/20418720 (2023).
The HDF Group. Hierarchical Data Format, version 5 https://www.hdfgroup.org/hdf5/ (1997–2023).
Maqbool, H. F. et al. A real-time gait event detection for lower limb prosthesis control and evaluation. IEEE transactions on neural systems and rehabilitation engineering 25, 1500–1509 (2016).
Burden, A., Trew, M. & Baltzopoulos, V. Normalisation of gait emgs: a re-examination. Journal of Electromyography and Kinesiology 13, 519–532 (2003).
Zhang, J.-T., Novak, A. C., Brouwer, B. & Li, Q. Concurrent validation of xsens mvn measurement of lower limb joint angular kinematics. Physiological measurement 34, N63 (2013).
Acknowledgements
This research is part of the MyLeg project and was funded by European Union’s Horizon 2020 Research and Innovation Programme grant number 780871. The authors would like to thank Daniek Haarman, Eline Woudenberg, Ismael Mrad, Juliet Buma, Rick ter Brake and Rutger Zandvoort for their assistence during the measurements of MyPredict 2.
Author information
Authors and Affiliations
Contributions
MyPredict 1 was conceived by R.S., E.S., R.P., E.P. and J.B. and collected by R.S., E.S. and R.P., MyPredict 2 was conceived by R.S., E.S., L.S., E.P. and J.B. and collected by R.S. and E.S. MyPredict 3 was conceived by R.S., M.Z., L.S., E.P. and J.B. and collected by R.S. and M.Z. Technical support during measurements by L.S. Supervision by E.P., M.P. and J.B. R.S. analyzed the results and wrote the first draft. All authors contributed to manuscript revision, read and approved the submitted version.
Corresponding authors
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.