Abstract
Balance is a common performance but nevertheless an essential part of performance analysis investigations in ski. Many skier pay attention to the training of balance ability in training. Inertial Measurement Unit, as a kind of Multiplex-type human motion capture system, is widely used because of its humanized human-computer interaction design, low energy consumption and more freedom provided by the environment. The purpose of this research is to use sensor to establish a kinematics dataset of balance test tasks extracted from skis to help quantify skier’ balance ability. Perception Neuron Studio motion capture device is used in present. The dataset contains a total of 20 participants’ data (half male) of the motion and sensor data, which is collected at a 100 Hz sampling frequency. To our knowledge, this dataset is the only one that uses a BOSU ball in the balance test. We hope that this dataset will contribute to multiple fields of cross-technology integration in physical training and functional testing, including big-data analysis, sports equipment design and sports biomechanical analysis.
Similar content being viewed by others
Background & Summary
Balance is evaluation element for the assessment of motion performance. In various biomechanical analyses, the movements of athletes are usually completed by multiple joints and muscle groups according to a certain time sequence, which is called Kinematic chain1,2,3.
Kinematic chain analysis is one of the keys in biomechanics analysis. High-speed infrared motion capture systems to track three-dimensional motion represent a baseline method used in scientific research;4,5 These are highly accurate but expensive and are thus often limited to being used at experimental sites. Most biomechanical research with data collection is limited to the triaxial variables of joints in anatomy, which makes it difficult to use sensor data analysis methods, such as machine learning or deep learning, for accurate analysis6,7,8. In now, wearable devices based on the combination of inertial sensing technology and wireless communication are gradually being used in the performance analysis of many sports events because of their affordability, usability, and ease of learning9,10. This combination is used for sports rehabilitation, the selection of athletes, and training performance analysis11,12,13,14,15,16.
Karl Mülly put forward the importance of balance in alpine skiing as early as 193317,18. The article points out that the difference between skiing balance and daily activity balance which is in skiing balance, athletes should adjust the height of the centre of gravity according to different techniques to complete the action, especially with the advancement of ski techniques such as carving, skiers need a strong core force to control the roll edge change and front and back balance, and accurately cut the skis to achieve the best sports performance18. Through Staniszewski’s7 research also can be determined that good balance ability has a positive impact on skiing, regardless of skiers’ technical level7. At present, there are few literatures about balance research in skiing, and the test methods for evaluating balance do not all have enough differentiation ability. Therefore, it is helpful to improve the specific balance ability of skiers by searching for test actions from the perspective of skiers’ balance training.
In the research on the balance ability of alpine skiing, Vjekoslav combined with the BOSU ball and inertial measurement unit in the laboratory for the first time, and found that in alpine skiing, the balance ability of athletes is different due to various sports grades. And also proposed to use the BOSU ball as an auxiliary tool for balance training, which provided the possibility of training static and dynamic balance at the same time, that is, to maintain a stable position on an unstable surface, balance training on the BOSU ball is desirable19. In recent years, the application of wearable sensors in the field of sports has gradually become mature. The Inertial Measurement Unit(IMU) motion capture system have been used in the performance analysis of many sports events, meeting the needs of football, rugby, canoeing, skiing and other training20.
Among the many sensor companies, the IMU motion capture system represented by Noitom’s Perception Neuron Studio(PNS) integrates a three-bit acceleration sensor, a three-axis gyroscope, and a three-axis magnetometer, which can obtain nine degrees of freedom data; it combines machine learning and signal processing visualization technology, and its application scenarios are recognized by a wide range of sports researchers to help athletes achieve better performance in Olympic events such as figure skating, fencing, and slalom kayaking21,22,23. As a result of the Noitom’s PNS is highly sensitive to acceleration parameters, the recognition accuracy of bending/extension (FE), lateral bending (LB) and axial rotation (AR) in joint motion is better than that of other IMU sensors.
The combination of an inertial motion capture system and an infrared motion capture system is a conventional method for collecting data to promote the scientific development of sports training5,20,21. On the other hand, the related theories and methods of intelligent equipment combined with balance training are still in the exploratory stage, and there is a lack of public kinematics datasets on various evaluation dimensions for engineers to optimize algorithms. This project starts with the balance ability in sports, use the PNS system, whereby human actions are used in function testing to establish a dataset reflecting the balance level; This data will help facilitate future research on analysis in sport performance.
Methods
Preparation phase
Experiment design
Kinematic data were collected based on the basic concept of balance and previous research24,25, and we developed an improved balance test action through literature and scales. Based on the Delphi method, we conducted two rounds of investigations with six experts, and finally selected three typical actions.
During these movements, the experimental process is that the participants wear legging and wore sneakers without air cushion. The participants wear sensors on the corresponding body parts, and the PNS system selected the lower body acquisition mode, and. Before the acquisition, we will check the number of sensors, sensor initialization, signal quality, and posture calibration that ensure the device will not be put into use until it reaches the acquisition standard. The participant starts with standing. When participants are ready and we say “start”, Axis Neuron Studio software records motion data at the same time. During the test, we can observe the signal strength in real time. When the signal is poor, we will adjust it in time to ensure the integrity and validity of the data, and then continue the test. They required to complete the following actions(see Table 1)24,26,27,28,30.
Equipment and environment
Data and signal acquisition equipment are mainly used to collect three-dimensional motion information from the movement of the human body. The motion capture system is Perception Neuron Studio (Noitom Perception Neuron Studio, Noitom Technology Ltd., Beijing, China). This system is responsible for collecting lower limb motion signals, which can be real-time transmission of acceleration (Acce), angular velocity (Gyro), quaternion (Quat), velocity (Velo), and position (Posi). In this experiment, the sampling rate of the data acquisition system is 100 Hz, Perception Neuron Studio uses ultra-high precision aerospace-grade sensor calibration, improves the measurement range of the sensor and the parameters of the sensor are show into Table 2 (see Table 2). The collection environment of the device requires the participant to wear seven sensors, as shown in (see Fig. 2), for the sensor wearing position map.
In order to reduce the influence of strong magnetic field environment on the output data, in the experiment that keep the field within 1–3 meters of the field away from strong magnetic equipment, and before the experiment starts, the equipment is open the anti-mag node. After the experiment, the PNS acquisition software was used to correct the data, and finally the data was uploaded to the database (see Fig. 6). In other published studies, we also experimented with participants using OptiTrack (OptiTrace, Norkov Technology Co., Ltd., China) infrared cameras to ensure data reliability24.
On the ferromagnetic problem interference, the tiny interference of ferromagnetic problem is certainly inevitable. However, during the experiment, the following experimental requirements can minimize the ferromagnetic problem. Firstly, the laboratory environment is highly demagnetized during the conduct of the experiment. Except for the experimental equipment, any electronic equipment is turned off and removed from the laboratory. Second, the PNS equipment used in this experiment is highly resistant to magnetization, and the data it goes to is very little affected by magnetic interference25.
Participants
A total of 20 college students passed the screening for motor function and became participants in our study. Among them, there were 10 males and 10 females with a mean age of 25.35 years and a standard deviation of 2.35. Motor function screening requires the participants to perform routine functional exercise tests to ensure that the participants have no obvious movement disorders, such as severe sports injuries, joint inflammation, or balance defects. None of the participants in our study reported any known movement disorders or other health problems that could affect mobility. The study was conducted in accordance with the Declaration of Helsinki. Before the experiment, participants were informed of the contents of the experiment, and each participant voluntarily signed an informed consent form and agreed to participate in the experiment. The body size of the participants is presented.(see Table 3).
Recording phase
The participants wear tights with sensors on the corresponding body parts, and the system selects the lower body collection mode. Before the collection, we evaluate the equipment based on the number of sensors, sensor initialization, signal quality, and sensor attitude; the equipment is used only when the collection standards are reached. Because the surrounding environment affects the magnetization, we recommend using four consecutive static postures to perform a calibration of the acquisition device on the Axis Neuron Studio software (https://neuronmocap.com/perception-neuron-studio-system). To prevent the participants from misunderstanding the actions, they should be given thorough explanations and trained on the actions before the experiment. Each participant should start in a standing posture, and for each action, asked to perform the action tests. When the participant is ready, we tell them to begin and the Axis Neuron Studio software records the exercise data as the exercise is being performed. During the test period, the signal strength should be observed in real time. When the signal is poor, it is important to pause and make timely adjustments to ensure the integrity and reliability of the data before continuing the test(see Fig. 3).
Data Records
We chose to export two different data formats: inertial data and action flow data.
The inertial data is divided into four parts per record:
-
1.
The first field indicates the name of the body part, such as Hips, SpineBottom, etc. There are 7 body parts in this study.
-
2.
The second field shows the feature type, which can be “Sensor”, “Joint”, or “Bone.”
-
3.
The third section indicates the signal type: acceleration (Acce), angular velocity (Gyro), quaternion (Quat), velocity (Velo), and position (Posi). It also includes the lost packet mark, Lost, for when the signal quality is poor.
-
4.
The fourth field contains the specific component values, including X, Y, Z components, of which the quaternion has an additional W component.
The action flow data provides human anatomy information. It can support most 3D animation production software, including 3dMax, Unity, and Maya. The action stream data format is divided into two parts:
-
1.
Size: defines the size of the main bones of the body in cm.
-
2.
Motion: defines the number of frames, frame rate, and the rotation angle of each joint in each frame.
The dataset is available at Figshare (https://doi.org/10.6084/m9.figshare.20579541.v1)26,27. Please refer to the Code Availability for the related code. This data provides a set of motion flow data described in motion anatomy terms, the content of the document in this format is converted from a BVH file. And in anatomy, it is defined and described in terms of the way the individual bones of the human body move.(see Table 4, Fig. 5). The BVH files to calculate durations borrowed from a publicly available dataset28.
Technical Validation
Validity
Movement of the participants’ lower limbs was evaluated by three-dimensional analysis of the functional movement of the hips, knees, and ankles24,29,30. The multiple correlation coefficient (CMC) was used to compare the range of motion (ROM) with Optitrack. By calculating the PNS and OptiTrack system in the test tasks, the posture angles of all joints have excellent similarity, and the lateral and frontal angles of all joints during squatting and walking have good similarity24. It shows that the experimental data have good validity.
On this motion plane, the joint angle waveform obtained by the PNS system was similar to that obtained by the Optitrack system. This indicates that the proposed equipment has good reliability. θf is the angle at time point ƒ that has been measured with the method M. M = 2, as there are two methods—PNS and OptiTrack—and F is the number of time points. θf is the mean angle at the time point. ƒ is between the angles measured by the two systems.
Calibration
As mentioned in the recording phase, a four-step calibration procedure was used to calibrate the motion capture system prior to recording and again as needed. After all the sensors were calibrated, the initial posture of the participant was consistent with the posture of the model in the software, as shown in (see Fig. 4a): facing forward, arms hanging naturally at the participant’s sides. We kept all models in the central region of the software’s sensor area to keep the models’ sensor locations stable. To assess the quality of the calibration, we extracted the X, Y, and Z positions of the center of mass in the last three frames of the subject’s stand straight while in the same position (see Fig. 7).
After the calibration procedure, In Fig. 7, the projection deviation is concentrated at 5 cm in convex hull, This indicates the initial spatial position of the participants across task are relatively centralized and consistent, reflecting a good calibration quality in the present study20.
Usage Notes
BVH data can be imported directly into 3ds Max or Unity, or into other applications that support it with the appropriate plug-ins. It can be processed using the Python parsing function of the PNS (https://bvh.noitom.cn, custom code cannot be shared because parsing the site is private.), which has the added benefit of defining and describing the various bones in the human body. However, researchers should be aware of several anomalies in the research data: For example, because of the influence of various factors, there are abnormal values in the data which led to missing frames; therefore, in the experimental data processing, we chose to use the PNS software to fill in these missing frames first. Researchers should also pay attention to the lack of markers in these filled frames, which may affect the research results. In addition, we will further study the relationship between action recognition analysis and objective posture evaluation. In the field of sports and technology, we will explore the use of complex and accurate sensing equipment to visualize technical actions in the field of sports and technology to solve the problem of pain points in data analysis in the field of physical training31,32,33,34,35,36.
Code availability
The data processing procedures that we perform on the dataset are those mentioned above.
1. The Python code used to extract the frame number of CSV files to be found at https://doi.org/10.6084/m9.figshare.20579541.v127 (Csv and Bvh are the raw data and angle is the corresponding parsed data part. The csv file initials have been updated to the participant experiment sequence number.)
2. Web-based download: the BVH files to calculate durations can be found at https://physionet.org/content/kinematic-actors-emotions/2.1.0/.
References
Willson, J. D. Core stability and its relationship tolower extremity function and injury[J]. J Am Acad Or–thop Surg 13(5), 316–325 (2005).
Okada, T., Huxel, Kellie, C. & Nesser, T. W. Relationship Between Core Stability, Functional Movement, and Performance. Journal of Strength and Conditioning Research 25(1), 252–261, https://doi.org/10.1519/jsc.0b013e3181b22b3e (2011).
Decicco, P. V. & Fisher, M. M. The effects of proprioceptive neuromuscular facilitation stretching on shoulder range of motion in overhand athletes.[J]. Journal of Sports Medicine & Physical Fitness 45(2), 183 (2005).
Healey, J., Picard, R.W., Startlecam: A Cybernetic Wearable Camera, Proc. 2nd Intl Symp. Wearable Computers (ISWC 98)[J]. IEEE CS Press, pp: 42-49 (1998).
Sandbakk, O., Ettema, G., Leirdal, S., Jakobsen, V. & Holmberg, H. C. Analysis of a sprint ski race and associated laboratory determinants of world-class performance[J]. Eur. J. Appl. Physiol. 111, 947–957 (2011).
Hebert-Losier, K. & Supej, M. Biomechanical factors influencing the performance of elite alpine ski racers[J]. Sports Medicine. 44(4), 519–533 (2014).
Staniszewski, M., Zybko, P. & Wiszomirska, I. 2016. Influence of a nine day alpine ski training programme on the postural stability of people with different levels of skills[J]. Biomedical Human Kinetics. 8(1), 24–31 (2016).
Brodie, M., Walmsley, A. & Page, W. Fusion motion capture: a prototype system using inertial measurement units and GPS for the biomechanical analysis of ski racing.Sports. Technology. 1(1), 17–28 (2008).
Camomilla, V., Bergamini, E., Fantozzi, S. & Vannozzi, G. J. S. Trends supporting the in-field use of wearable inertial sensors for sport performance evaluation: A systematic review. 18, 873 (2018).
Chambers, R., Gabbett, T. J., Cole, M. H. & Beard, A. J. S. M. The use of wearable microsensors to quantify sport-specific movements. 45, 1065–1081 (2015).
Boyd, L. J., Ball, K. & Aughey, R. J. J. I. J. O. S. P., performance. The reliability of MinimaxX accelerometers for measuring physical activity in Australian football. 6, 311–321 (2011).
Fulton, S. K., Pyne, D. B. & Burkett, B. J. J. O. S. S. Validity and reliability of kick count and rate in freestyle using inertial sensor technology. 27, 1051–1058 (2009).
Janssen, I. & Sachlikidis, A. J. S. B. Validity and reliability of intra-stroke kayak velocity and acceleration using a GPS-based accelerometer. 9, 47–56 (2010).
Harding, J. W., Mackintosh, C. G., Hahn, A. G. & James, D. A. J. T. E. O. S. Classification of aerial acrobatics in elite half-pipe snowboarding using body mounted inertial sensors. 7, 447–456 (2008).
Cust, E. E., Sweeting, A. J., Ball, K. & Robertson, S. J. J. O. S. S. Machine and deep learning for sport-specific movement recognition: A systematic review of model development and performance. 37, 568–600 (2019).
Aziz, O., Park, E. J., Mori, G. & Robinovitch, S. N. J. G., posture. Distinguishing the causes of falls in humans using an array of wearable tri-axial accelerometers. 39, 506–512 (2014).
Mülly, K. Vom Gleichgewicht beim Skifahren. (Aschmann & Scheller, 1933).
Muller, E. & Schwameder, H. Biomechanical aspects of new techniques in alpine skiing and ski-jumping. J Sports Sci 21(9), 679–692 (2003).
Vjekoslav C., et al. Comparison of standard and newer balance tests in recreational alpine skiers and ski novices[J]. Montenegrin Journal of Sports ence and Medicine, 2017, 43(10).
Camomilla, V., Bergamini, E., Fantozzi, S. & Vannozzi, G. Trends supporting the in-field use of wearable inertial sensors for sport performance evaluation: A systematic review. Sensors 18(3), 873 (2018).
Kim, H. et al. Application of a Perception Neuron System in Simulation-Based Surgical Training. J. Clin. Med. 8, 124 (2019).
Hanyu, Y. A Feasibility Study on Utilization in Figure Skating by A Wireless Inertia Sensor Motion Capture System. Waseda Journal of Human Sciences. 1–7 (2021).
Zhang, M. et al. Kinematic dataset of actors expressing emotions. Scientific Data. 7, 292 (2020).
Gustavsen, M., Aamodt, G. & Marit Mengshoel, A. Measuring balance in sub-acute stroke rehabilitation. Advances in Physiotherapy. 8(1), 15–22 (2006).
Agrawal, Y. et al. The modified Romberg Balance Test: normative data in US adults. Otology & neurotology: official publication of the American Otological Society. 32(8), 1309–1314 (2011).
Berg, K., Maki, B., Williams, J., Holliday, P. & Wood-Dauphinee, S. Clinical and laboratory measures of postural balance in an elderly population. Arch Phys Med Rehabil. 73, 1073–80 (1992).
Dong, A. A New Kinematic Dataset of Lower Limbs Action for balance testing, Figshare, https://doi.org/10.6084/m9.figshare.20579541.v1 (2022).
Berg, K., Wood-Dauphinee, S., Williams, J. & Maki, B. Measuring balance in the elderly: validation of an instrument. Can J Public Health. 83, S7–11 (1992).
Berg, K., Wood-Dauphinee, S. & Williams, J. The balance scale:reliability assessment with elderly residents and patients with an acute stroke. Scand J Rehabil Med. 27, 27–36 (1995).
Agrawal, Y. et al. The modified Romberg Balance Test: normative data in US adults. Otology & neurotology: official publication of the American Otological Society, American Neurotology Society and European Academy of Otology and Neurotology. 32(8), 1309–1314 (2011).
Berg, K. Measuring balance in the elderly: Development and validation of an instrument. (1992).
Berg, K. O. et al. Clinical and laboratory measures of postural balance in an elderly population. 73, 1073–1080 (1992).
Berg, K., Wood-Dauphinee, S. & Williams, J. J. S. J. O. R. M. The Balance Scale: reliability assessment with elderly residents and patients with an acute stroke. 27, 27–36 (1995).
Ferrari, A. et al. Quantitative comparison of five current protocols in gait analysis. 28, 207–216 (2008).
Piazza, S. J. & Cavanagh, P. R. J. J. O. B. Measurement of the screw-home motion of the knee is sensitive to errors in axis alignment. 33, 1029–1034 (2000).
Germanotta, M. et al. Estimation of human center of mass position through the inertial sensors-based methods in postural tasks: An accuracy evaluation. 21, 601 (2021).
Acknowledgements
This research was funded by the National key research and development program of the Science and Technology Winter Olympics, “Study on the Ergonomics and Operation Improvement of Ice-Snow Sports Equipment” (No. 2019YFF0302001) and the Fundamental Research Funds for Central Universities (No. 2021TD010).
Author information
Authors and Affiliations
Contributions
A.D., Y.S. devised the experimental protocol, performed data acquisition and data processing, wrote the manuscript, prepared all materials for the manuscript, and organized the data. F.W. participated in data acquisition and data processing. Y.S., (X.Q., Y.Z.,Y.Y.,) helped write the manuscript and supervised the study.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Dong, A., Wang, F., Shuai, Z. et al. A new kinematic dataset of lower limbs action for balance testing. Sci Data 10, 209 (2023). https://doi.org/10.1038/s41597-023-02105-2
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41597-023-02105-2