Abstract
Quantum electrodynamics (QED), the quantum field theory that describes the interaction between light and matter, is commonly regarded as the best-tested quantum theory in modern physics. However, this claim is mostly based on extremely precise studies performed in the domain of relatively low field strengths and light atoms and ions1,2,3,4,5,6. In the realm of very strong electromagnetic fields such as in the heaviest highly charged ions (with nuclear charge Z ≫ 1), QED calculations enter a qualitatively different, non-perturbative regime. Yet, the corresponding experimental studies are very challenging, and theoretical predictions are only partially tested. Here we present an experiment sensitive to higher-order QED effects and electron–electron interactions in the high-Z regime. This is achieved by using a multi-reference method based on Doppler-tuned X-ray emission from stored relativistic uranium ions with different charge states. The energy of the 1s1/22p3/2 J = 2 → 1s1/22s1/2 J = 1 intrashell transition in the heaviest two-electron ion (U90+) is obtained with an accuracy of 37 ppm. Furthermore, a comparison of uranium ions with different numbers of bound electrons enables us to disentangle and to test separately the one-electron higher-order QED effects and the bound electron–electron interaction terms without the uncertainty related to the nuclear radius. Moreover, our experimental result can discriminate between several state-of-the-art theoretical approaches and provides an important benchmark for calculations in the strong-field domain.
Similar content being viewed by others
Main
Highly charged ions (HCI), that is, highly ionized atoms with one or few bound electrons, are unique quantum systems in which atomic structure can be studied in the presence of a very strong electromagnetic field of the nucleus, which, for heavy ions, is several orders of magnitude higher than the most intense laser fields available nowadays. In these extreme fields, the effects of the quantum vacuum on the atomic structure, such as the emission and absorption of virtual photons by a bound electron as well as its interaction with virtual electron–positron pairs, are strongly enhanced. Contrary to the case of light atoms7,8, in this strong-field regime, QED calculations of the atomic structure of high-Z atoms must be performed using non-perturbative approaches9,10 with respect to the electron–nucleus coupling constant Zα, where Z is the number of protons in the nucleus and α ≈ 1/137 is the fine structure constant. Following decades of extensive theoretical work, now strong-field QED can provide predictions in all orders of Zα (non-perturbatively) and up to the second order of the expansion in α, that is, incorporating two virtual photon loops (one-electron two-loop terms, see, for example, figure 1 in ref. 11). For ions with more than one electron, the electron–electron interaction terms also play an important part (two-electron QED terms, see, for example, figure 1 in ref. 12). Stringent tests of these predictions are essential not only for a better understanding of the strong-field QED but also in the perspective of the recently proposed methods for the generation of highly precise frequency standards based on HCI13,14, and for the determination of fundamental constants and tests of the standard model13,15. Recent disagreements between experiment and theory on the muon anomalous magnetic moment and positronium fine structure16,17 could potentially point to previously unknown physics in the electroweak sector.
The most rigorous tests of strong-field QED are performed using measurements of transition energies, hyperfine structure and bound electron g-factors1,18,19,20,21,22,23. The latter has reached the highest accuracy, to the ppm level, but are mostly limited to relatively light few-electron atoms, silicon (Z = 14) and calcium (Z = 20), in which theoretical predictions based on Zα expansion are sufficient. Only very recently, a measurement in the mid-Z range has been performed, on hydrogen-like tin (Z = 50) (ref. 24) in which, however, two-loop QED effects could not yet be tested because of deficiencies in the theoretical predictions.
For transition energies, the most suitable systems are hydrogen-like (H-like, one bound electron), helium-like (He-like, two bound electrons) and lithium-like (Li-like, three bound electrons) heavy ions—that is, few-body systems simple enough to allow for very high-accuracy QED predictions25,26 that can be then tested experimentally.
For H-like systems, the most precise measurement up to now has been performed for the 1s Lamb shift in H-like uranium that provided a test of the first-order QED contributions at a per cent level but was insufficient to test higher-order QED effects27.
He-like heavy ions are the simplest multi-electron systems that offer the unique possibility of high-precision tests of electron–electron interactions in the presence of strong electromagnetic fields. For these systems, there have been only a few measurements performed up to now and their precision has been insufficient for a meaningful test of the two-loop or two-electron QED effects26,28,29,30.
Most of these measurements have been performed at large-scale accelerators and heavy-ion storage rings, in which sufficient quantities of heavy HCI can be produced by stripping the bound electrons at a few hundred MeV per nucleon (MeV/u) kinetic energies, and then be decelerated and stored under well-controlled conditions for precision spectroscopy31. The energy resolution of the commonly used semiconductor detectors along with uncertainties stemming from the relativistic Doppler effect have been the main limiting factors for further improvement of precision.
For Li-like heavy ions, very accurate measurements are available—for example, for Li-like uranium performed with an Electron Beam Ion Trap (EBIT)32. But in these heavy ions, the respective contributions from one-electron QED (including nuclear size and polarization) and many-electron effects could not be disentangled. To provide a stringent test of high-order QED effects, several attempts have been made in recent years to substantially enhance the experimental precision by using high-resolution detection methods: cryogenic microcalorimeter detectors33,34 and a transmission crystal diffraction spectrometer35. In spite of successful proof-of-principle measurements, in particular regarding the high energy resolution, no significant improvement of the experimental uncertainty has been achieved up to now, partially because of the low detection efficiency of these devices and because of the systematic errors related to the relativistic Doppler effect.
Here we report on a precise measurement of the 1s1/22p3/2 J = 2 → 1s1/22s1/2 J = 1 intrashell transition energy in He-like uranium (Z = 92, Zα = 0.67) performed with a specially designed twin high-resolution crystal spectrometer. The achieved experimental accuracy enables us to test second-order QED effects and radiative electron–electron interaction terms in high-Z He-like ions—that is, in the presence of an extremely strong Coulomb field. Energy differences between the intrashell transition in He-like uranium and the analogous transitions in Li-like and beryllium-like (Be-like, four bound electrons) uranium ions are also obtained, making it possible to disentangle one-electron and many-electron QED effects. Furthermore, this result enables us to differentiate between different theoretical methods for describing few-electron systems with and without incorporating second-order one-electron and two-electron QED corrections in strong Coulomb fields.
Experimental methods
The experiment is performed at the experimental storage ring (ESR) at GSI in Darmstadt in which a beam of H-like uranium ions is stored, cooled and decelerated to an energy of 41.03 MeV/u (see the Methods for more details). The He-like U 1s1/22p3/2 J = 2 → 1s1/22s1/2 J = 1 intrashell transition is produced by electron capture in H-like uranium ions interacting with an internal gas-jet target and the subsequent decay from excited levels. The transition X-rays are detected using two high-resolution crystal spectrometers placed at observation angles of θ = ±90° near the gas-target chamber, on the inner and outer sides of the storage ring (Fig. 1), and equipped with X-ray charge-coupled devices (CCDs) as position-sensitive detectors. The main reason for using two spectrometers is to collect a larger set of data, as well as to have redundancy in the measurement of the observation angles to reduce the final statistical and systematic uncertainties. The photon energy E′ measured by the spectrometer is determined by the value of θ, the ion velocity v and the photon energy E in the ion reference frame by the relativistic Doppler formula E′ = E/[γ(1 − βcosθ)], where β = v/c is the ion velocity in the units of the speed of light (s) and \(\gamma =1/\sqrt{(1-{\beta }^{2})}\) is the associated Lorentz factor. The energy of the He-like U intrashell transition (close to 4,510 eV) is measured with respect to the analogous transitions in Li-like (4,459.37 ± 0.21 eV) and Be-like uranium (4,501.72 ± 0.21 eV), similarly obtained by electron capture in He-like and Li-like ions, respectively, and measured in the past in an EBIT36,37. To drastically decrease systematic uncertainties, the three transition energies from the different uranium charge states are reduced in the laboratory frame to a common value E′ ≈ 4,320 eV using the relativistic Doppler effect by an appropriate choice of the ion kinetic energies (41.035 MeV/u of He-like ions, 30.160 MeV/u for Li-like ions and 39.293 MeV/u for Be-like ones), and by using an additional stationary reference line. The value of E′ is chosen to match exactly half of the stationary reference energy based on the zinc Kα1 fluorescence line, which is detected in second-order reflection (E = 8,638.906 ± 0.073 eV; ref. 38). By comparing moving and stationary references, the observation angle θ is precisely measured. The use of a reference line from ions travelling at a speed close to that of the ions of interest allows for an important reduction of the uncertainty related to θ compared with that being determined from geometry alone.
When two X-ray spectral lines with very similar Bragg angles, Θ and Θref, but emitted from sources moving with different velocities, v and vref, are considered, the relation between their energies, E and Eref, in the ion reference frame is given by
where γ and γref are the Lorentz form factors of the moving X-ray sources, and θ is the observation angle corresponding to the middle position on the CCD (y = y0). Δa is the difference in the line position on the dispersion axis (x-axis) and D is the crystal–detector distance. n and nref are the respective diffraction orders and the terms 1 − δ/sin2Θ are the correction due to the diffraction index nr = 1 + δ of the crystal.
The observation angle θ is evaluated by letting E refer to the energies of the Li-like or Be-like intrashell transitions (with n = 1) and Eref to the energy of the zinc fluorescence line (with nref = 2, βref = 0 and γref = 1). Then with θ determined in this manner, the unknown He-like uranium transition energy E can be obtained by letting Eref be the Li-like or Be-like transition energies in the same formula. For the specific case of θ ≈ 90°, the use of the reference energy from a moving ion results in a drastic reduction of the systematic uncertainty related to the observation angle by a factor proportional to ∣β − βref∣/β (1/7.3 and 1/50 when Li-like U or Be-like U are used as references, respectively)39.
X-rays emitted by the different ion transitions are collected for several days, starting with Li-like uranium (for a duration of 11 h, resulting in a total amount of approximately 1,400 photons per spectrometer), followed by He-like uranium (84 h, 1,800 photons) and finally with Be-like uranium (24 h, 700 photons). The higher statistics for He-like uranium are intended to compensate for the lower peak-to-background ratio observed during the measurement. To calibrate and control the stability of the spectrometer, the zinc Kα1 lines were measured every 12 h. During the entire period, variations in the peak position of less than 6 μm are measured for the second-order reflected lines, which corresponds to variations of less than 10 meV for the energy of first-order reflected transitions. The resulting images of the spectral lines detected by the outer spectrometer are presented in Fig. 1d. Similar images are obtained for the inner spectrometer. The slope of the lines is because of the relativistic Doppler effect. Different y positions on the CCDs correspond to different values of the observation angle θ and thus to different line energies, yielding the slope. Details of the determination of spectral line positions are presented in the Methods.
The final value of the He-like U transition energy EHe is obtained from the weighted average of four dependent measurements corresponding to the two possible moving reference lines (Li-like and Be-like U) for each of the two spectrometers (see the Methods for more details). The final value is EHe = 4,509.763 ± 0.034stat ± 0.162syst eV. Here and in the rest of the Article, the statistical and systematic uncertainties indicate the value of 1 standard deviation. The systematic uncertainty of the absolute energy of the He-like U intrashell transition is dominated by uncertainties of the reference energies of the Li-like and Be-like uranium transitions. This is not the case for the energy differences between intrashell transitions of the different charge states of uranium for which much more accurate values are obtained. These differences are only negligibly affected by the uncertainties of the reference line energies that, in this case, determine only the uncertainty of the observation angle. The energy differences between the intrashell transitions in He-like, Li-like and Be-like uranium are obtained by subtracting the value Eref from the energy E from equation (1). The corresponding average values are EHe–Li = 50.233 ± 0.037stat ± 0.037syst eV, EHe–Be = 8.175 ± 0.042stat ± 0.005syst eV and EBe–Li = 42.072 ± 0.041stat ± 0.031syst eV. As expected, the uncertainty due to Eref is partially cancelled out resulting in a drastic reduction of the systematic uncertainty.
Discussion
Our value for the 1s1/22p3/2 J = 2 → 1s1/22s1/2 J = 1 intrashell transition in He-like uranium is in agreement with the result of the previous measurement30 but with a gain in accuracy by a factor of more than 6 (Table 1 and Fig. 2a). It validates the most recent prediction using multi-configuration Dirac–Fock (MCDF) calculations, including QED effects, as well as ab initio QED calculations, based on the two-time Green’s functions12,30,40,41 (see the Methods for more details). However, a clear disagreement is seen with older calculations based on relativistic configuration interaction (RCI) and relativistic many-body perturbation theory as well as a slight disagreement with the result of the unified approach42,43,44.
As can be seen from Fig. 3a, our accuracy enables us to access elusive contributions of two-loop one-electron QED terms—that is, second-order perturbation terms with respect to the electromagnetic coupling constant (proportional to α2) and non-perturbative with respect to the electron–nucleus interaction (proportional to Zα). The uncertainty of state-of-the-art theoretical predictions (ab initio and MCDF) is mainly because of the uncertainty of 0.086 eV of the one-electron two-loop contributions. The uncertainty due to the finite size of the nucleus contributes only 0.034 eV (for details, see Extended Data Table 2). Moreover, our experimental result provides a test of bound electron–electron interaction terms to an unprecedented degree of accuracy in heavy two-electron atomic systems.
A comparison of the measured intrashell transition energy difference between He-like and Li-like U with previous experiments and theoretical predictions is presented in Table 2 and Fig. 2b. As can be seen, a gain in accuracy of more than a factor of 20 is obtained with respect to the available previous measurement30. This accuracy is of the same order as the uncertainty of state-of-the-art theoretical predictions. Along with the experimental uncertainty, the theoretical uncertainty is also reduced in this case because of the cancellation of the terms related to one-electron QED, finite nuclear size and nuclear polarization. In particular, our value is in very good agreement (less than 1.5 standard deviations) with the most recent ab initio QED predictions12,30. A worse agreement is visible with MCDF-based predictions (2.2 and 3.4 standard deviations for He–Li and He–Be differences, respectively). A larger discrepancy (more than 20 and 3.8 standard deviations for He–Li and Be–Li differences, respectively) is observed with older predictions based on RCI methods43,45 that do not include some QED contributions. As seen in Fig. 3b, the relative transition energy measurement between the He-like and Li-like ions opens a way to exclusively measure the effect of bound electron–electron interactions in such atomic systems. This is not the case for energy differences involving Be-like ions, in which the experimental accuracy is better than the theoretical one because of the presence of quasi-degenerate states in Be-like atomic systems, which inhibits the convergence of the calculations12. In this case, a gain by a factor of 10 with respect to the previous measurement36 is obtained.
In conclusion, we have performed a high-precision measurement of the 1s1/22p3/2 J = 2 → 1s1/22s1/2 J = 1 intrashell transition in the heaviest two-electron system—that is, He-like uranium, which is sensitive to one-electron higher-order (two-loop) QED effects. Moreover, by measuring the energy differences with respect to analogous intrashell transitions in Li-like and Be-like uranium ions, the bound electron–electron interaction in the presence of the strongest electromagnetic fields, including the two-electron radiative QED effects, is accurately tested as well. Overall, our experimental results are in good agreement with the most recent ab initio QED calculations as well as with those based on the MCDF approach but do not agree with other predictions based on the relativistic many-body perturbation theory and RCI methods. To obtain such an accuracy, a method of double reference (moving and stationary) is used, which allows for control and reduction of the main systematic uncertainties related to the relativistic velocity of the stored ions. This method could be implemented in all future measurements involving Doppler tuning. Further improvements in the experimental accuracy would be possible by reducing the diameter of the gas-jet target, by aligning the two spectrometers along the same axis, as well as by using light H-like ions as a more accurate moving reference, which can independently be measured in EBITs.
Methods
Setup details
The experiment is performed at the ESR at GSI in Darmstadt47, where a beam of around 4 × 107 H-like uranium ions is stored, cooled and decelerated from a production energy of 296 MeV/u to an energy of 41.03 MeV/u. The momentum spread of the ion beam is Δp/p ≈ 10−5, and its width is about 2 mm. Excited He-like uranium ions are obtained by electron capture from H-like uranium ions interacting with an internal gas-jet target48. The target is a supersonic nitrogen gas-jet with a width of about 5 mm and a typical areal density of 1012 particles per cm2, which guaranteed single-collision conditions in the ion–target interaction.
The He-like U 1s1/22p3/2 J = 2 → 1s1/22s1/2 J = 1 intrashell transition is obtained from the decay of the He-like U 1s1/22p3/2 J = 2 level. The 1s1/22p3/2 J = 2 excited state mainly decays to the ground state by a magnetic quadrupole (M2) transition, with a branching ratio of 70% and to the 1s1/22s1/2 J = 1 state by an electric dipole (E1) intrashell transition, the transition of interest, with a branching ratio of 30% and a photon energy of 4,510 eV.
The X-rays are detected by two high-resolution crystal spectrometers placed at observation angles of θ = ±90° near the gas-target chamber, on the inner and outer sides of the storage ring (Fig. 1). The two spectrometers are mounted in the Johann geometry with 50 × 25 mm2 cylindrically bent germanium (220) crystals and a radius of curvature of R = 2,000 mm. The two spectrometers are equipped with two X-ray CCD cameras: Andor iKon-L SO in the outer spectrometer and Great Eyes 2048 2048 BI in the inner spectrometer. Both cameras have 2,048 × 2,048 pixels with a size of 13.5 × 13.5 μm2. Both spectrometers are under vacuum (10−5−10−4 mbar) to reduce the X-ray absorption. For both moving and stationary X-ray sources, the corresponding Bragg angle of the crystal spectrometers is fixed to Θ = 45.85°. The resulting detectable energy range is about 80 eV for the first-order reflection. For each arm, the distance D between the CCD and the crystal is fixed by the focusing conditions of the Johann geometry, namely, D = R sinΘ = 1,435 mm. The distance between the gas-jet target and the crystal is reduced to 885 mm to increase the spectrometer efficiency and make the spectrometer not sensitive to spatial inhomogeneities of the source.
The energy calibration is performed using a zinc Kα1 line, produced by irradiating at 45° a movable 10-μm thick target with an X-ray tube equipped with a Mo cathode. The thickness and the angle of the target are chosen to have X-rays emitted in both directions of the alignment axis of the common spectrometers, passing through the ESR gas-target chamber for the inner spectrometer (Fig. 1).
From the comparison between stationary and moving energy references, the observation angle is determined with an accuracy δθ = 0.011°. This value corresponds to an uncertainty of 0.17 mm of the gas-jet centre position, much smaller than 1 mm, the uncertainty obtained by standard alignment tools used in past experiments35 and better than the typical accuracy expected with standard optical alignments. Its contribution to the final He-like U transition energy measurement is additionally reduced by the use of the moving ion reference line. For the observation angle of θ = ± 90°, uncertainty related to the ion velocity plays a marginal part39.
CCD image acquisition and fitting
The CCD cameras are operated in a single-photon counting mode, and the images are analysed using an algorithm similar to those in refs. 49,50. By counting only single photons, the CCD noise is efficiently suppressed. Furthermore, by using the energy resolution of the CCDs and setting a small energy window around the energy of interest, background photons are also very efficiently suppressed.
The position of the spectral lines is determined by a two-dimensional fit of the CCD images with a model function
where the x and y coordinates indicate the dispersive axis and the axis perpendicular to it, respectively. The line slope b is mainly because of the Doppler shift using the corresponding different observation angle. The quadratic dependency is normally expected for point-like sources. The position of the line is determined by the value of a, that is, the intersection between the spectral line and the middle of the CCD, corresponding to y = y0. The typical accuracy of the spectral line position is 0.8 pixels and 0.08 pixels for the moving ions and the stationary reference line, respectively (1 pixel = 13.5 μm), which corresponds to 4 meV for the first-order reflections and 0.8 meV for the second-order reflections.
For f(x), different profiles are considered including Gaussian, super-Gaussian and Lorentzian. The determination of the most adapted profile and the associated parameters are obtained by use of the Bayesian data analysis program Nested_fit51,52,53. This code is also used to assign probabilities to the different possible profiles by the computation of the Bayesian evidence using the nested sampling method. The most adapted profile is the convolution between a flat distribution and a Gaussian54. This kind of profile reflects, using the Doppler shift, the density distribution of the X-ray source, that is, the region resulting from the intersection of the gas-jet target (with a uniform density over a circle of about 5 mm of diameter determined by the skimmer geometry), with the ion beam (with a Gaussian distribution of a typical size of 2 mm)55. As shown in Extended Data Fig. 1, the collected data are in good agreement with the simulated ones obtained for a gas-jet target with a diameter of about 5.8 mm and a Gaussian ion beam with a full width at half maximum of 2 mm. This size is compatible with the expectations and past direct measurements (6.2−7.3 mm) obtained with another gas at different pressure and temperature56. The main difference between the simulation and the modelling curve is the sharpness of the border that depends on the width of the Gaussian ion beam that can slightly vary for different beam settings. Note that the determination of the line position does not depend on the choice of the profile. For the stationary Zn source, f(x) is mainly determined by the natural width of the transitions together with the reflection curve of the diffracting crystal and the focusing properties of the spectrometers. The dependency on (y − y0)2 is not considered because it does not make a significant contribution to our setup54. The projection of spectral lines and their modelling relative to the outer spectrometer are presented in Extended Data Fig. 1.
Asymmetries of the line profiles arising from possible satellite lines or spectrometer aberrations, which could cause a bias on the line position evaluation, are investigated by two different approaches. The first approach consists of the comparison of the two sides of the projected line using the Kolmogorov–Smirnov test. The second approach uses Nested_fit to evaluate models with one line or two unresolved lines54. Both methods confirm the absence of asymmetries.
Uncertainty budget and final value average
Considering the two spectrometer arms and the two possible moving references, four evaluations of the He-like U intrashell energy are obtained. For each evaluation, a typical uncertainty budget is given in Extended Data Table 1, in which contributions smaller than 0.5 meV are not listed. Statistical uncertainties of the moving ions are about one order of magnitude higher than the uncertainties associated with the zinc reference line.
Moving lines are always compared using the stationary reference line as intermediate. \(\Delta a=(a-{a}^{{\rm{stat}}})-({a}_{{\rm{ref}}}-{a}_{{\rm{ref}}}^{{\rm{stat}}})\) in equation (1) is always evaluated with respect to the stationary reference line positions astat and \({a}_{{\rm{ref}}}^{{\rm{stat}}}\) systematically measured during the long data acquisition period required to determine a and aref. The main systematic contribution comes from the Doppler correction to the energy of the moving calibration ions, which is equal to \(\delta {E}_{{\rm{mov}}}^{{\rm{Li}}}=\delta {E}_{{\rm{mov}}}^{{\rm{Be}}}=0.21\,{\rm{eV}}\) for both Li-like and Be-like intrashell transitions36,37. In the absolute energy evaluation, such a contribution causes a systematic effect of 0.246 eV when Li-like ions are used as reference (Extended Data Table 1). These significantly higher values than δEmov are mainly because δEmov acts twice in equation (1): first to determine the observation angle and second as a reference line. Only the contribution of δEmov for the observation angle is present in the relative energy measurement. Measurements using Be-like ions as reference have smaller systematic uncertainties (0.217 eV for the absolute energy and 0.005 eV for the relative energy) because of the much stronger reduction of the observation angle uncertainty because of the proximity of the Be-like and He-like ion velocities (see section ‘Experimental methods’). The energy of the stationary reference includes the literature uncertainty (73 meV; ref. 38) plus the uncertainty of the line modelling (26 meV) obtained from the difference between the line maximum and the position of the strongest component of the doublet of Voigt profiles used for the fit.
The velocity of the ions is defined by the velocity of the electron in the electron cooler device31. The corresponding uncertainty can be decomposed into two sources. The first one is related to the voltage divider linearity, which was calibrated by Physikalisch-Technische Bundesanstalt in 2018, with a relative accuracy of 4.3 × 10−5 for the range of interest. The second source is the offset uncertainty, related to the space charge density effect of the electron beam and the contact potentials between the electron cooler elements. This contribution is estimated conservatively to be 5 V.
The four energy evaluations corresponding to the use of the two moving references and the two spectrometers are shown in Extended Data Fig. 2. The evaluations using the Li-like U transition as a reference give slightly lower values for the He-like transition energy than the evaluations based on the Be-like U transition. However, all measurements are compatible with each other within the total uncertainty, mainly because of the reference transition energy uncertainties. When the same reference line is used, measurements from different spectrometers are compatible with each other within the statistical uncertainties only.
The final energy value ⟨E⟩ and associated uncertainty σ is obtained by the standard method of the weighted average of correlated measurements (see, for example, refs. 57,58,59) with
Ej indicates the single measurements and \({({C}_{ij})}^{-1}\) is the inverse of the correlation matrix
In the above formula, Ei corresponds to the different energy evaluations from equation (1) from different spectrometers and using different reference lines, and pk the different independent parameters with the associated uncertainties δpk. The different values of Ei are strongly correlated by common parameters as the moving reference energy, the stationary calibration line positions astat and \({a}_{{\rm{ref}}}^{{\rm{stat}}}\) (two per arm) and the cooler voltage parameters (common to all four measurements). The final systematic uncertainty of about 0.16 eV from four correlated measurements, each with a systematic uncertainty of about 0.25 eV is because of the averaging procedure. If the four evaluations were independent, a reduction of a factor of √4 = 2 would be expected. Because of the use of the same calibration line for each arm (and other correlations), the uncertainty correlation reduces this factor to √2, which is approximately the value of a ratio between the single evaluation uncertainty and the final one as expected. The additional reduction of the final uncertainty is because of the smaller systematic uncertainty associated with the evaluation using Be-like U as a reference, because of the closer velocity for He-like and Be-like U beams and thus to the higher reduction of the uncertainty related to the observation angle evaluation.
A similar analysis treatment is applied for the relative energy evaluations.
MCDF calculation
The MCDF values reported here are obtained by MCDF calculations. For He-like U, double excitations up to 7i orbitals are included, using the sequence of configurations given in refs. 60,61 to remove the unwanted ones. For Li-like uranium, it takes into account all singly, doubly and triply excited configurations up to 8k orbitals using the latest version of the MCDFGME code. For Be-like U, the highest excited orbital is 7i. The main quadruple excitations are added too. In all cases, the Breit interaction is treated self-consistently and higher-order retardation is included62,63. The mass shift correction is evaluated in a relativistic model following refs. 64,65 as described in ref. 66.
The QED corrections with two and four vertices are included. The self-energy with a finite size correction67,68 is included. The vacuum polarization at the Uehling approximation (order α(Zα)) is treated to all orders by inclusion in the Dirac equation69. The Wichmann and Kroll correction (order α(Zα)3) and approximate higher-order corrections of order α(Zα)5 and α(Zα)7 are also taken into account. The self-energy screening correction is taken into account following the model operator from refs. 70,71. The latest two-loop self-energy contributions from ref. 72, other two-loop corrections mixing self-energy and vacuum polarization73,74,75 and the Kàllén and Sabry two-loop vacuum polarization are included. The finite size used is from ref. 76. The nuclear polarization from refs. 77,78,79 is included too. Both latter contributions are very small when considering the transition energy differences between different charge states. The different contributions and associated uncertainties are given in Extended Data Table 4.
Data availability
The datasets generated during and/or analysed during the current study are available from the corresponding authors on reasonable request.
Code availability
The two-dimensional data fit is performed with the publicly available author’s code Nested_fit (v.4.0) available in the GitHub repository (https://github.com/martinit18/nested_fit). All other codes and scripts that are used to generate or analyse data during this study are available from the corresponding authors on request.
References
Sailer, T. et al. Measurement of the bound-electron g-factor difference in coupled ions. Nature 606, 479–483 (2022).
Hanneke, D., Fogwell, S. & Gabrielse, G. New measurement of the electron magnetic moment and the fine structure constant. Phys. Rev. Lett. 100, 120801 (2008).
Aoyama, T., Hayakawa, M., Kinoshita, T. & Nio, M. Tenth-order QED contribution to the electron g − 2 and an improved value of the fine structure constant. Phys. Rev. Lett. 109, 111807 (2012).
Morel, L., Yao, Z., Cladé, P. & Guellati-Khélifa, S. Determination of the fine-structure constant with an accuracy of 81 parts per trillion. Nature 588, 61–65 (2020).
Biesheuvel, J. et al. Probing QED and fundamental constants through laser spectroscopy of vibrational transitions in HD+. Nat. Commun. 7, 10385 (2016).
Rengelink, R. J. et al. Precision spectroscopy of helium in a magic wavelength optical dipole trap. Nat. Phys. 14, 1132–1137 (2018).
Yerokhin, V. A., Pachucki, K. & Patkóš, V. Theory of the Lamb shift in hydrogen and light hydrogen-like ions. Ann. Phys. 531, 1800324 (2019).
Yerokhin, V. A., Patkóš, V. & Pachucki, K. Atomic structure calculations of helium with correlated exponential functions. Symmetry 13, 1246 (2021).
Shabaev, V. M. Two-time Green’s function method in quantum electrodynamics of high-Z few-electron atoms. Phys. Rep. 356, 119–228 (2002).
Indelicato, P. & Mohr, P.J. in Handbook of Relativistic Quantum Chemistry (ed. Liu, W.) 131–242 (Springer, 2016).
Yerokhin, V. A. & Shabaev, V. M. Lamb shift of n = 1 and n = 2 states of hydrogenlike atoms, 1 ≤ Z ≤ 110. J. Phys. Chem. Ref. Data 44, 033103 (2015).
Malyshev, A. V., Kozhedub, Y. S. & Shabaev, V. M. Ab initio calculations of the 2p3/2 → 2s transition in He-, Li-, and Be-like uranium. Phys. Rev. A 107, 042806 (2023).
Kozlov, M. G., Safronova, M. S., López-Urrutia, J. R. C. & Schmidt, P. O. Highly charged ions: optical clocks and applications in fundamental physics. Rev. Mod. Phys 90, 045005 (2018).
King, S. A. et al. An optical atomic clock based on a highly charged ion. Nature 611, 43–47 (2022).
Safronova, M. S. et al. Search for new physics with atoms and molecules. Rev. Mod. Phys 90, 025008 (2019).
Abi, B. et al. Measurement of the positive muon anomalous magnetic moment to 0.46 ppm. Phys. Rev. Lett. 126, 141801 (2021).
Gurung, L., Babij, T. J., Hogan, S. D. & Cassidy, D. B. Precision microwave spectroscopy of the positronium n = 2 fine structure. Phys. Rev. Lett. 125, 073002 (2020).
Volotka, A. V. et al. Test of many-electron QED effects in the hyperfine splitting of heavy high-Z ions. Phys. Rev. Lett. 108, 073001 (2012).
Ullmann, J. et al. High precision hyperfine measurements in bismuth challenge bound-state strong-field QED. Nat. Commun. 8, 15484 (2017).
Skripnikov, L. V. et al. New nuclear magnetic moment of 209Bi: resolving the bismuth hyperfine puzzle. Phys. Rev. Lett. 120, 093001 (2018).
Sturm, S. et al. g factor of hydrogenlike 28Si13+. Phys. Rev. Lett. 107, 023002 (2011).
Glazov, D. A. et al. g factor of lithiumlike silicon: new challenge to bound-state QED. Phys. Rev. Lett. 123, 173001 (2019).
Kosheleva, V. P., Volotka, A. V., Glazov, D. A., Zinenko, D. V. & Fritzsche, S. g factor of lithiumlike silicon and calcium: resolving the disagreement between theory and experiment. Phys. Rev. Lett. 128, 103001 (2022).
Morgner, J. et al. Stringent test of QED with hydrogen-like tin. Nature 622, 53–57 (2023).
Shabaev, V. M. et al. Stringent tests of QED using highly charged ions. Hyperfine Interact. 239, 60 (2018).
Indelicato, P. QED tests with highly charged ions. J. Phys. B 52, 232001 (2019).
Gumberidze, A. et al. Quantum electrodynamics in strong electric fields: the ground-state Lamb shift in hydrogenlike uranium. Phys. Rev. Lett. 94, 223001 (2005).
Gumberidze, A. et al. Electron-electron interaction in strong electromagnetic fields: the two-electron contribution to the ground-state energy in He-like uranium. Phys. Rev. Lett. 92, 203004–4 (2004).
Thorn, D. B. et al. Precision measurement of the K-shell spectrum from highly charged xenon with an array of x-ray calorimeters. Phys. Rev. Lett. 103, 163001 (2009).
Trassinelli, M. et al. Observation of the 2p3/2 → 2s1/2 intra-shell transition in He-like uranium. Europhys. Lett. 87, 63001 (2009).
Steck, M. & Litvinov, Y. A. Heavy-ion storage rings and their use in precision experiments with highly charged ions. Prog. Part. Nucl. Phys. 115, 103811 (2020).
Beiersdorfer, P., Chen, H., Thorn, D. B. & Trabert, E. Measurement of the two-loop Lamb shift in lithiumlike U89+. Phys. Rev. Lett. 95, 233003 (2005).
Hengstler, D. et al. Towards FAIR: first measurements of metallic magnetic calorimeters for high-resolution x-ray spectroscopy at GSI. Phys. Scripta T166, 014054 (2015).
Kraft-Bermuth, S. et al. Precise determination of the 1s Lamb shift in hydrogen-like lead and gold using microcalorimeters. J. Phys. B 50, 055603 (2017).
Gassner, T. et al. Wavelength-dispersive spectroscopy in the hard x-ray regime of a heavy highly-charged ion: the 1s Lamb shift in hydrogen-like gold. New J. Phys. 20, 073033 (2018).
Beiersdorfer, P., Knapp, D., Marrs, R. E., Elliott, S. R. & Chen, M. H. Structure and Lamb shift of 2s1/−2p3/2 levels in lithiumlike U89+ through neonlike U82+. Phys. Rev. Lett. 71, 3939 (1993).
Beiersdorfer, P. Spectral measurements of few-electron uranium ions produced and trapped in a high-energy electron beam ion trap. Nucl. Instrum. Methods Phys. Res. B 99, 114–116 (1995).
Deslattes, R. D. et al. X-ray transition energies: new approach to a comprehensive evaluation. Rev. Mod. Phys. 75, 35–99 (2003).
Trassinelli, M. et al. Doppler-tuned Bragg spectroscopy of excited levels in He-like uranium: a discussion of the uncertainty contributions. J. Phys. Conf. Ser. 163, 012026 (2009).
Artemyev, A. N., Shabaev, V. M., Yerokhin, V. A., Plunien, G. & Soff, G. QED calculation of the n = 1 and n = 2 energy levels in He-like ions. Phys. Rev. A 71, 062104 (2005).
Kozhedub, Y. S., Malyshev, A. V., Glazov, D. A., Shabaev, V. M. & Tupitsyn, I. I. QED calculation of electron-electron correlation effects in heliumlike ions. Phys. Rev. A 100, 062506 (2019).
Drake, G. W. F. Theoretical energies for the n = 1 and 2 states of the helium isoelectronic sequence up to Z = 100. Can. J. Phys. 66, 586 (1988).
Chen, M. H., Cheng, K. T. & Johnson, W. R. Relativistic configuration-interaction calculations of n = 2 triplet states of heliumlike ions. Phys. Rev. A 47, 3692 (1993).
Plante, D. R., Johnson, W. R. & Sapirstein, J. Relativistic all-order many-body calculations of the n = 1 and n = 2 states of heliumlike ions. Phys. Rev. A 49, 3519–3530 (1994).
Cheng, K. T., Chen, M. H. & Sapirstein, J. Quantum electrodynamic corrections in high-Z Li-like and Be-like ions. Phys. Rev. A 62, 054501 (2000).
Stöhlker, T. et al. Charge-exchange cross sections and beam lifetimes for stored and decelerated bare uranium ions. Phys. Rev. A 58, 2043–2050 (1998).
Franzke, B. The heavy ion storage and cooler ring project ESR at GSI. Nucl. Instrum. Methods Phys. Res. B 24-25, 18–25 (1987).
Kühnel, M. et al. Low-Z internal target from a cryogenically cooled liquid microjet source. Nucl. Instrum. Methods Phys. Res. A 602, 311–314 (2009).
Fourment, C. et al. Broadband, high dynamics and high resolution charge coupled device-based spectrometer in dynamic mode for multi-keV repetitive x-ray sources. Rev. Sci. Instrum. 80, 083505 (2009).
Zamponi, F., Kämpfer, T., Morak, A., Uschmann, I. & Förster, E. Characterization of a deep depletion, back-illuminated charge-coupled device in the x-ray range. Rev. Sci. Instrum. 76, 116101 (2005).
Trassinelli, M. Bayesian data analysis tools for atomic physics. Nucl. Instrum. Methods Phys. Res. B 408, 301–312 (2017).
Trassinelli, M. The Nested_fit data analysis program. Proceedings 33, 14 (2019).
Trassinelli, M. & Ciccodicola, P. Mean shift cluster recognition method implementation in the nested sampling algorithm. Entropy 22, 185 (2020).
Trassinelli, M. Shape and satellite studies of highly charged ions x-ray spectra using bayesian methods. Atoms 11, 64 (2023).
Weber, G. et al. Total projectile electron loss cross sections of U28+ ions in collisions with gaseous targets ranging from hydrogen to krypton. Phys. Rev. ST Accel. Beams 18, 034403 (2015).
Gassner, T. & Beyer, H. F. Spatial characterization of the internal gas target at the ESR for the FOCAL experiment. Phys. Scripta 2015, 014052 (2015).
Schmelling, M. Averaging correlated data. Phys. Scr. 51, 676 (1995).
Bevington, P. R. & Robinson, D. K. Data Reduction and Error Analysis for the Physical Sciences (McGraw-Hill, 2003).
Gregory, P. Bayesian Logical Data Analysis for the Physical Sciences: A Comparative Approach with Mathematica Support (Cambridge Univ. Press, 2005).
Froese Fischer, C. The Hartree-Fock Method for Atoms (Wiley, 1977).
Gorceix, O., Indelicato, P. & Desclaux, J. P. Multiconfiguration Dirac-Fock studies of two-electron ions. I. Electron-electron interaction. J. Phys. B 20, 639 (1987).
Gorceix, O. & Indelicato, P. Effect of the complete Breit interaction on two-electron ion energy levels. Phys. Rev. A 37, 1087–1094 (1988).
Indelicato, P. & Desclaux, J. P. Multiconfiguration Dirac-Fock calculations of transition energies with QED corrections in three-electron ions. Phys. Rev. A 42, 5139–5149 (1990).
Shabaev, V. M. QED theory of the nuclear recoil effect in atoms. Phys. Rev. A 57, 59–67 (1998).
Shabaev, V. M. & Artemyev, A. N. Relativistic nuclear recoil corrections to the energy levels of multicharged ions. J. Phys. B 27, 1307 (1994).
Li, J. et al. Mass- and field-shift isotope parameters for the 2s−2p resonance doublet of lithiumlike ions. Phys. Rev. A 86, 022518 (2012).
Mohr, P. J. & Soff, G. Nuclear size correction to the electron self-energy. Phys. Rev. Lett. 70, 158–161 (1993).
Beier, T., Mohr, P. J., Persson, H. & Soff, G. Influence of nuclear size on QED corrections in hydrogenlike heavy ions. Phys. Rev. A 58, 954 (1998).
Indelicato, P. Nonperturbative evaluation of some QED contributions to the muonic hydrogen n=2 Lamb shift and hyperfine structure. Phys. Rev. A 87, 022501 (2013).
Shabaev, V. M., Tupitsyn, I. I. & Yerokhin, V. A. Model operator approach to the Lamb shift calculations in relativistic many-electron atoms. Phys. Rev. A 88, 012513 (2013).
Shabaev, V. M., Tupitsyn, I. I. & Yerokhin, V. A. QEDMOD: Fortran program for calculating the model Lamb-shift operator. Comp. Phys. Commun. 189, 175–181 (2015).
Yerokhin, V. A. Two-loop self-energy in the Lamb shift of the ground and excited states of hydrogenlike ions. Phys. Rev. A 97, 052509 (2018).
Yerokhin, V. A., Indelicato, P. & Shabaev, V. M. Nonperturbative calculation of the two-loop Lamb shift in Li-like ions. Phys. Rev. Lett. 97, 253004 (2006).
Yerokhin, V. A., Indelicato, P. & Shabaev, V. M. Two-loop QED corrections in few-electron ions. Can. J. Phys. 85, 521–529 (2007).
Yerokhin, V. A., Indelicato, P. & Shabaev, V. M. Two-loop QED corrections with closed fermion loops. Phys. Rev. A 77, 062510 (2008).
Angeli, I. & Marinova, K. P. Table of experimental nuclear ground state charge radii: an update. At. Data Nucl. Data Tables 99, 69–95 (2013).
Plunien, G., Müller, B., Greiner, W. & Soff, G. Nuclear polarization contribution to the Lamb shift in heavy atoms. Phys. Rev. A 39, 5428–5431 (1989).
Plunien, G. & Soff, G. Nuclear-polarization contribution to the Lamb shift in actinide nuclei. Phys. Rev. A 51, 1119–1131 (1995).
Plunien, G. & Soff, G. Erratum: nuclear-polarization contribution to the Lamb shift in actinide nuclei. Phys. Rev. A 53, 4614–4615 (1996).
Acknowledgements
The results presented here are based on the experiment E125, which is performed at the infrastructure ESR at the GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, in the framework of FAIR Phase-0 and SPARC collaboration. This work is supported by the Horizon 2020 research and innovation programme of the European Union and grant agreement no. 6544002. We acknowledge the support provided by ErUM FSP T05-‘Aufbau von APPA bei FAIR’ (BMBF nos. 05P19SJFAA and 05P21SJFA1). We thank A. Malyshev, V. Shabaev and Y. Kozhedub for providing previously unknown theoretical results and also for the discussions on theoretical uncertainties. M.T. thanks the ExtreMe Matter Institute EMMI and Alexander von Humboldt Foundation for their support for the stays at the GSI for the preparation and data acquisition. L.D. acknowledges funding support from the Initiative Physique des Infinis (IPI), a research training programme of the Idex SUPER at Sorbonne Université.
Author information
Authors and Affiliations
Contributions
The experiment was originally designed by M.T., R.L., H.F.B. and T.S.; R.L., G.G.P. and I.U. characterized the spectrometer crystals. The experiment was prepared and performed by R.L., M.T., T.S., L.D., U.S., S.T., F.M.K., P.D., J.G., A.G., R.E.G., R.H., P.-M.H., P.I., E.L., B.L., S.L., Y.A.L., N.P., M. Scheidel, R.S.S., M. Steck, S.S., K.S. and G.W. The data were analysed by R.L., M.T., L.D., M.G., J.M. and J.P.S., with the help of the spectrometer simulation performed by H.F.B., M.T., D.B. and P.J. Theoretical calculations were performed by P.I. The paper was written by M.T., R.L., A.G. and N.P. All authors discussed and approved the data as well as the paper.
Corresponding authors
Ethics declarations
Competing interests
The authors declare no competing interests.
Peer review
Peer review information
Nature thanks Toshiyuki Azuma and the other, anonymous, reviewer(s) for their contribution to the peer review of this work.
Additional information
Extended data
is available for this paper at https://doi.org/10.1038/s41586-023-06910-y.
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Extended data figures and tables
Extended Data Fig. 1 Experimental spectra and fits.
Projection, with respect to the dispersion axis (x-axis in Fig. 1 proportional to the photon energy), of the spectral lines recorded by the outer spectrometer for the intrashell transition of He-like U (a), Li-like U (b) and Be-like U (c), and the Kα1 line of zinc in second order reflection (d). The best fits to all transitions (solid lines) and the simulation of the He-like transition (dotted line) are also shown. One channel corresponds to 0.079 eV.
Extended Data Fig. 2 Details of the four measurements.
He-like U intrashell transition energy evaluations obtained from different spectrometer arms and using different moving calibration. Statistical and total uncertainties are indicated with red and black error bars, respectively. Error bars denote ± 1 standard deviation.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Loetzsch, R., Beyer, H.F., Duval, L. et al. Testing quantum electrodynamics in extreme fields using helium-like uranium. Nature 625, 673–678 (2024). https://doi.org/10.1038/s41586-023-06910-y
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/s41586-023-06910-y
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.