Abstract
The possibility that neutrinos may be their own antiparticles, unique among the known fundamental particles, arises from the symmetric theory of fermions proposed by Ettore Majorana in 19371. Given the profound consequences of such Majorana neutrinos, among which is a potential explanation for the matter–antimatter asymmetry of the universe via leptogenesis2, the Majorana nature of neutrinos commands intense experimental scrutiny globally; one of the primary experimental probes is neutrinoless double beta (0νββ) decay. Here we show results from the search for 0νββ decay of 130Te, using the latest advanced cryogenic calorimeters with the CUORE experiment3. CUORE, operating just 10 millikelvin above absolute zero, has pushed the state of the art on three frontiers: the sheer mass held at such ultralow temperatures, operational longevity, and the low levels of ionizing radiation emanating from the cryogenic infrastructure. We find no evidence for 0νββ decay and set a lower bound of the process half-life as 2.2 × 1025 years at a 90 per cent credibility interval. We discuss potential applications of the advances made with CUORE to other fields such as direct dark matter, neutrino and nuclear physics searches and large-scale quantum computing, which can benefit from sustained operation of large payloads in a low-radioactivity, ultralow-temperature cryogenic environment.
Main
The standard model of particle physics is a successful paradigm for the number, properties and interactions of fundamental particles. Nevertheless, the observation of neutrino oscillations indicates the incompleteness of the standard model: they imply non-vanishing neutrino masses, requiring an extension of the standard model, and violate three accidental symmetries connected to the flavour lepton numbers Le, Lμ and Lτ, leaving the difference between the baryon and lepton number, B − L, as the only unprobed quantity. A promising process to experimentally test B − L is neutrinoless double beta (0νββ) decay, in which a nucleus of mass number A and charge Z decays by the emission of only two electrons: (A, Z) → (A, Z + 2) + 2e−. We highlight that this process creates two electrons, namely two matter particles4. This decay can be mediated by various non-standard model mechanisms involving Majorana neutrino masses. A minimal extension of the standard model Lagrangian adds heavy Majorana neutrinos that mix with the known neutrinos to produce a set of light Majorana neutrinos, explaining the observed light neutrino masses5 and at the same time providing a mechanism to explain the baryon asymmetry in the universe2. At this time, experimental searches for 0νββ decay are the most sensitive means to corroborate this framework.
The 0νββ decay signature is a peak in the spectrum of summed energy of the two emitted electrons at the mass difference (Qββ) between the parent and daughter nuclei. A worldwide quest is ongoing, involving a range of nuclei such as 76Ge6,7, 136Xe8,9 and 130Te. The latter, in the form of TeO2 cryogenic calorimeters, is used by the Cryogenic Underground Observatory for Rare Events, CUORE10,11.
To fully exploit the potential of TeO2 crystals as cryogenic calorimeters, the CUORE Collaboration designed and built to our knowledge the largest dilution refrigerator ever constructed, capable of cooling approximately 1.5 t of material to a temperature of approximately 10 mK and maintaining it for years with a 90% duty cycle (1 t = 1,000 kg). In this Article, we describe the performance of CUORE over a four-year measurement campaign and the results of a new high-sensitivity 0νββ decay search with over 1 t yr of TeO2 exposure.
The CUORE experiment
CUORE is the culmination of thirty years of 0νββ decay searches with TeO2 cryogenic calorimeters12. 130Te benefits both from a high natural isotopic abundance of approximately 34%13 and a high Qββ of 2,527.5 keV14, placing the 0νββ decay region of interest above most natural γ-emitting radioactive backgrounds. The detector is an array of 988 natTeO2 cubic crystals15 (Fig. 1) of 5 × 5 × 5 cm3 size and ~750 g mass, for a total mass of 742 kg, which corresponds to 206 kg of 130Te. The array is arranged as 19 towers, each comprised of 13 floors containing four crystals. The crystals are operated as cryogenic calorimeters16 at a temperature of approximately 10 mK. To achieve this low-temperature environment, a novel cryogenic infrastructure—the CUORE cryostat—has been realized.
a, Rendering of the six-stage cryostat, with the pulse tubes and dilution unit, the internal low-radioactivity modern and Roman lead shields, and the array of 988 TeO2 crystals (light blue). b, The detector after installation. The plastic ring was used during assembly for radon protection. c, One of the calorimeters instrumented with an NTD Ge thermistor which measures the temperature increase induced by absorbed radiation. The Si heater is used to inject pulses for thermal gain stabilization. The polytetrafluoroethylene (PTFE) supports and the gold wires instrumenting the NTD and the heater provide the thermal link between the crystal and the heat bath, that is, the Cu frames24.
In a cryogenic calorimeter, the energy deposited by impinging radiation in the absorber crystal is turned into heat, resulting in a temperature rise (Extended Data Fig. 1). Each CUORE crystal (Fig. 1c) is instrumented with a neutron-transmutation-doped germanium thermistor (NTD)17 that converts thermal pulses into electric signals and a heater18 to inject reference heat pulses for thermal gain stabilization19. Thermal signals can be induced by electrons emitted in 0νββ decays but also other background radiation, for example, γ and α particles from residual radioactive contaminants or cosmic ray muons.
CUORE is protected by several means against backgrounds that can mimic a 0νββ decay. It is located underground at the Laboratori Nazionali del Gran Sasso (LNGS) of INFN, Italy, under a rock overburden equivalent to approximately 3,600 m of water, which shields from hadronic cosmic rays and reduces the muon flux by six orders of magnitude. Environmental γ backgrounds are suppressed by a 30-cm layer of low-radioactivity lead above the detector (Fig. 1), a 6-cm-thick lateral and bottom shield of 210Pb-depleted ancient lead recovered from a Roman shipwreck20 (Extended Data Fig. 2), and a 25-cm-thick lead shield outside the cryostat. Environmental neutrons are suppressed by a 20-cm layer of polyethylene and a thin layer of boric acid outside the external lead shield. Finally, radioactive contaminants in the crystals and in the adjacent structures are minimized by careful screening of material for radio-purity and use of high-efficiency cleaning procedures and manipulation protocols21.
Cryogenic innovation and performance
Dilution refrigerator technology was originally proposed in the 1950s22 and underwent considerable development in the 1980s driven also by the application of cryogenic calorimeters for single-particle detection23. Gradually, experimental volumes of the order of tens of litres capable of hosting cold masses of up to 60 kg at 10 mK temperature24 were achieved. Ultimately, detectors were limited by the capacity, duty cycle and radio-purity of commercial or near-commercial cryogenic systems. In the context of this history, the CUORE cryostat represents a major advance in cryogenic technology, reaching an experimental volume of approximately 1 m3 and a cold mass of 1.5 t (detectors, holders, shields) at 10 mK, which corresponds to a 20-fold improvement in experimental volume and target mass compared to the previous state of the art at this temperature scale. Prior to CUORE, the ultimate temperature for comparable target masses was in the resonant-mass gravitational antenna community at 65 mK23.
The CUORE detector is hosted in a multistage cryogen-free cryostat25 (Fig. 1), equipped with five pulse tube cryocoolers that avoid pre-cooling with a liquid helium bath, thus enabling a high duty cycle. A custom-designed dilution unit with a double condensing line for redundancy provides more than 4 μW cooling power at 10 mK. The cryostat is uniquely designed to provide the necessary i) cooling power and temperature stability over a time scale of years, ii) very low radioactivity environment, and iii) extremely low-vibration conditions. As shown in Fig. 2a, b, CUORE became operational in 2017, with the initial period mostly devoted to characterization and optimization campaigns. Since 2019, the data-taking has proceeded smoothly with a duty cycle of approximately 90%. Figure 2d shows that the temperature stability achieved is at the level of 0.2% (±3σ range) over a period in excess of one year. Such a stability is important to achieve a uniform response of all detectors over time. The CUORE calorimeters are sensitive to thermal signals and feature an intrinsic thermal fluctuation limit of approximately 0.5 keV, so any process inducing heat dissipation equal to or greater than 0.5 keV degrades the energy resolution. Mechanical vibrations can be transferred to the inner components and produce heat through friction. To minimize the impact of vibrational noise, the calorimeter array is mechanically decoupled from the cryostat by a custom suspension system. Vibrations induced by the pulse tubes at the 1.4-Hz operational frequency and its harmonics are particularly relevant. In CUORE, we actively tune the pulse tube relative phases for vibration cancellation26 (Fig. 3). This solution is transferable to any cryogenic application involving signals in the same bandwidth of the pulse-tube-induced noise.
a, The exposure accumulated by CUORE (teal), along with the exposure used for this analysis (orange). Parts of 2017 and 2018 were dedicated to maintenance and optimization of the cryogenic set-up. b, Since then, CUORE has been operating stably with a 90% duty cycle (March 2019–October 2020). c, Examples of temperature instabilities induced by external causes. From left to right: blackout (June 2019), earthquake in Albania of magnitude 6.4, 520 km away (November 2019), regular maintenance (July 2020), and insertion of calibration sources (September 2020). d, The temperature stability of CUORE over ~1 yr of continuous operation, shown by a plot of relative temperature fluctuation versus time, and a histogram of the same data. (1 t yr = 1,000 kg yr.).
a, Frequency spectrum of the noise for a random combination of the pulse tube phases (orange) and after the active phase tuning (teal). For reference, the frequency spectrum of physical signals is also reported. b, Integral of the power spectrum at the pulse tube frequency (1.4 Hz) and its harmonics before and after active noise cancellation.
CUORE now collects sensitive exposure with 984 out of 988 calorimeters, at a rate that is, to our knowledge, unprecedented for cryogenic particle detectors. Below, we describe the data treatment and 0νββ decay search with greater than 1 t yr of TeO2 exposure.
Data analysis and results
CUORE data are subdivided into datasets of 1–2 months of physics data, separated by a few days of calibration data collected with the detector exposed to 232Th and/or 60Co sources.
The voltage across each NTD is amplified, passed through an anti-aliasing filter, and continuously digitized with a 1-kHz sampling frequency27,28. We identify thermal pulses in the data stream and compute the pulse amplitudes, applying optimum filters that maximize the frequency-dependent signal-to-noise ratio29. To monitor and correct for possible drifts of the thermal gain of the detectors we exploit two ‘standard candles’: monoenergetic heater pulses for the calorimeters with functioning and stable heaters (>95% of the total), and events from the 2,615-keV 208Tl calibration line for the remainder. Drift-stabilized pulse amplitudes are converted to energy using the regularly acquired source calibration data30. We blind the 0νββ search via a data-salting procedure that produces an artificial peak at Qββ30. Once the full analysis procedure is finalized and frozen, we reverse the salting.
To simplify the analysis, we eliminate data from periods affected by high noise or failed data processing, which amounts to 5% of the exposure. Furthermore, calorimeters with greater than 19-keV full width at half maximum (FWHM) energy resolution at the 2,615-keV calibration line are discarded, adding 3% loss in exposure. In addition to these so-called base cuts, the following second-level cuts are then applied to suppress single background-like or low-quality events. Monte Carlo simulations show that approximately 88% of 0νββ decay events release their full energy in a single crystal31. Hence, we apply an anti-coincidence cut that excludes events depositing energy in more than one crystal. Finally, we use pulse shape discrimination to eliminate pulses that are consistent with more than one energy deposit in the pulse time window, pulses with a non-physical shape, and excessively noisy pulses that survived the previous selections (Extended Data Fig. 3). The selection efficiencies are summarized in Table 1, with details provided in Methods.
The detector response to a monoenergetic energy deposition is an important input to the 0νββ decay search. We empirically model the response function of each calorimeter as a sum of three equal-width Gaussians and determine the function parameters from a fit to the 2,615-keV calibration line3. As a characteristic indicator of the overall energy resolution of the calorimeters we quote the exposure-weighted harmonic mean FWHM of the detectors at this calibration line, 7.78 ± 0.03 keV. All values are reported as mean ± s.d.
We quantify the scaling of energy resolution with energy and investigate energy reconstruction bias—that is, the deviation of reconstructed γ-line positions from the literature values—by fitting the calorimeter response functions to prominent γ lines in the physics data, allowing the peak means and widths to vary in the fit. The bias is allowed to scale as a quadratic function of energy, as done in our previous result32, whereas the resolution scaling has been changed to a linear function of energy, following studies showing that it was overparameterized by a quadratic scaling. The results, extrapolated to Qββ, are an exposure-weighted harmonic mean FWHM energy resolution of 7.8 ± 0.5 keV and an energy bias of less than 0.7 keV. We summarize all the relevant analysis quantities in Table 1.
Figure 4 shows the full energy spectrum along with the [2,490, 2,575] keV fit region, which contains only one background peak at 2,505.7 keV from the simultaneous absorption of two coincident γ rays from 60Co in the same crystal. We estimate that around 90% of the continuum background consists of degraded α particles from radioactive contaminants of the support structure surface, and the other approximately 10% are multi-Compton scattered 2,615-keV γ events31,33.
We separately show the effects of the base cuts, the anti-coincidence (AC) cut, and the pulse shape discrimination (PSD). The most prominent background peaks in the spectrum are highlighted. Inset, the region of interest after all selection cuts, with the best-fit curve (solid red), the best-fit curve with the 0νββ rate fixed to the 90% CI limit (blue), and background-only fit (black) superimposed.
We run an unbinned Bayesian fit with uniform non-negative priors on the background and 0νββ decay rates. The fit with a background-only model—that is, excluding the 0νββ component—yields a mean background rate of (1.49 ± 0.04) × 10−2 counts keV−1 kg−1 yr−1 at Qββ for a corresponding median exclusion sensitivity of \({T}_{1/2}^{0\nu } > 2.8\times {10}^{25}\,{\rm{y}}{\rm{r}}\) (90% credibility interval (CI)). The fit with the signal-plus-background model shows no evidence for 0νββ decay. We find the best fit at Γ0ν = (0.9 ± 1.4) × 10−26 yr−1 and set a limit on the process half-life of \({T}_{1/2}^{0\nu } > 2.2\times {10}^{25}\,{\rm{y}}{\rm{r}}\) (90% CI). Systematic uncertainties are included as nuisance parameters and affect both the best fit and the limit by 0.8% (Extended Data Table 1). Compared to the sensitivity, the probability of getting a stronger limit is 72%. This represents, to our knowledge, the current world-leading 0νββ sensitivity for 130Te, having improved in accordance with our increased exposure since our previous result32, and although the actual limit is weaker, it is well within the range of possible outcomes due to statistical fluctuations.
Under the common assumption of a light neutrino exchange mechanism, the 130Te half-life limit converts to a limit on the effective Majorana mass of mββ < 90–305 meV, with the spread induced by different nuclear matrix element calculations34,35,36,37,38,39,40. This limit on mββ is among the strongest in the field, proving the competitiveness of the cryogenic calorimeter technique used in CUORE. CUORE will continue to take data until it reaches its designed 130Te exposure of 1,000 kg yr.
Impact
We have demonstrated that the cryogenic calorimeter technique is scalable to tonne-scale detector masses and multi-year measurement campaigns, while maintaining low radioactive backgrounds. Next-generation calorimetric 0νββ decay searches exploiting these developments are planned. Among these, CUPID (CUORE Upgrade with Particle IDentification)41 will use the same cryogenic infrastructure as CUORE, replacing the TeO2 crystals with scintillating \({{\rm{Li}}}_{2}^{100}{{\rm{MoO}}}_{4}\) crystals and exploiting the scintillation light for greater than 100-fold active suppression of the α background42,43. In parallel, the AMoRE collaboration aims to build a large-mass calorimetric 0νββ decay experiment in Korea44. In general, the possibility to cool large detector payloads paired with the low energy thresholds achievable by cryogenic calorimeters will benefit next-generation projects at the frontier of particle physics, for example dark matter searches such as SuperCDMS45 and CRESST46, and low-energy observatories exploiting CEνNS for solar and supernova neutrino studies47 and neutrino flux monitoring of nuclear reactors48.
A serendipitous effect is that the cryogenic innovations pioneered by CUORE for 0νββ decay appear to be a solution-in-waiting for the challenges faced by the relatively young, but rapidly growing, field of quantum information technology. The need to cool increasingly large arrays of qubits to less than approximately 100 mK means there is now a commercial market for large, high-cooling-power dilution refrigerators, with some featuring technological solutions derived from CUORE. Moreover, the recent realization that ionizing radiation from natural radioactivity will be a limiting factor for the coherence time of quantum processors with an increasing number of qubits49 suggests that the one-time niche, low-radioactivity ultralow-temperature cryogenics pioneered for 0νββ decay may become mainstream in large-scale quantum computing50.
Methods
Optimum trigger and analysis threshold
The continuous data stream of CUORE is triggered with the optimum trigger, an algorithm based on the optimum filter51 characterized by a lower threshold than a more standard derivative trigger32. A lower threshold enables us not only to reconstruct the low-energy part of the spectrum, but also yields a higher efficiency in reconstructing the events in coincidence between different calorimeters, and consequently a more precise understanding of the corresponding background components52,53.
The optimum trigger transfer function of every event is matched to the ideal signal shape, obtained as the average of good-quality pulses, so that frequency components with low signal-to-noise ratio are suppressed. A trigger is fired if the filtered signal amplitude exceeds a fixed multiple of the noise root mean square (RMS), defined separately for each calorimeter and dataset. We evaluate the energy threshold by injecting fake pulses of varying amplitude, calculated by inverting the calibration function, into the data stream. We reconstruct the stabilized amplitude of the fake pulses, fit the ratio of correctly triggered events to generated events with an error function, and use the 90% quantile as a figure of merit for the optimum trigger threshold. This approach enables monitoring of the threshold during data collection, and is based on the assumption that the signal shape is not energy dependent, that is, that the average pulse obtained from high-energy γ events is also a good template for events of a few keV. The distribution of energy threshold at 90% trigger efficiency is shown in Extended Data Fig. 4.
For this work we set a common analysis threshold of 40 keV, which results in >90% trigger efficiency for the majority (97%) of the calorimeters, while at the same time allowing the removal of multi-Compton events from the region of interest through the anti-coincidence cut.
Efficiencies
The total efficiency is the product of the reconstruction, anti-coincidence, pulse shape discrimination (PSD) and containment efficiencies.
The reconstruction efficiency is the probability that a signal event is triggered, has the energy properly reconstructed, and is not rejected by the basic quality cuts requiring a stable pre-trigger voltage and only a single pulse in the signal window. It is evaluated for each calorimeter using externally flagged heater events54, which are a good approximation of signal-like events.
The anti-coincidence efficiency is the probability that a true single-crystal event correctly passes our anti-coincidence cut, instead of being wrongly vetoed owing to an accidental coincidence with an unrelated event. It is extracted as the acceptance of fully absorbed γ events at 1,460 keV from the electron capture decays of 40K, which provide a reference sample of single-crystal events.
The PSD efficiency is obtained as the average acceptance of events in the 60Co, 40K and 208Tl γ peaks that already passed the base and anti-coincidence cuts. In principle, the PSD efficiency could be different for each calorimeter, but given the limited statistics in physics data we evaluate it over all channels and over the full dataset. To account for possible variation between individual calorimeters, we compare the PSD efficiency obtained by directly summing their individual spectra with that extracted from an exposure-weighted sum of the calorimeters’ spectra. We find an average ±0.3% discrepancy between the two values and include it as a global systematic uncertainty in the 0νββ fit. This takes a Gaussian prior instead of the uniform prior used in our previous result32, which had its uncertainty come from a discrepancy between two approaches that has since been resolved.
Finally, the containment efficiency is evaluated through Geant4-based Monte Carlo simulations55 and accounts for the energy loss due to geometrical effects as well as bremsstrahlung.
Principal component analysis for PSD
In this analysis we use a new algorithm based on principal component analysis (PCA) for pulse shape discrimination. The method has been developed and documented for CUPID-Mo56, and has been adapted for use in CUORE57. This technique replaces the algorithm used in previous CUORE results, which was based on six pulse shape variables30. The PCA decomposition of signal-like events pulled from γ calibration peaks yields a leading component similar to an average pulse, which on its own captures >90% of the variance between pulses. We choose to treat the average pulse of each calorimeter in a dataset as if it were the leading PCA component, normalizing it like a PCA eigenvector. We can then project any event from the same channel onto this vector and attempt to reconstruct the 10-s waveform using only this leading component. For any waveform x and leading PCA component w with length n, we define the reconstruction error as:
This reconstruction error metric measures how well an event waveform can be reconstructed using only the average pulse treated as a leading PCA component. Events that deviate from the typical expected shape of a signal waveform are poorly reconstructed and have a high reconstruction error. We normalize the reconstruction errors as a second-order polynomial function of energy on a calorimeter-dataset basis (see Extended Data Fig. 5), and cut on the normalized values by optimizing a figure of merit for signal efficiency over expected background in the Qββ region of interest. Using this PCA-based method, we obtain an overall efficiency of (96.4 ± 0.2)% compared to the (94.0 ± 0.2)% from the pulse shape analysis used in our previous results, as well as a 50% reduction in the PSD systematic uncertainty from 0.6% to 0.3%.
Statistical analysis
The high-level statistical 0νββ decay analysis consists of an unbinned Bayesian fit on the combined data developed with the BAT software package58. The model parameters are the 0νββ decay rate (Γ0ν), a linearly sloped background, and the 60Co sum peak amplitude. Γ0ν and the 60Co rate are common to all datasets, with the 60Co rate scaled by a preset dataset-dependent factor to account for its expected decay over time. The base background rate, expressed in terms of counts keV−1 kg−1 yr−1, is dataset-dependent, whereas the linear slope to the background is shared among all datasets, because any structure to the shape of the background should not vary between datasets. Γ0ν, the 60Co rate, and the background rate parameters have uniform priors that are constrained to non-negative values, whereas the linear slope to the background has a uniform prior that allows both positive and negative values.
In addition to these statistical parameters, we consider the systematic effects induced by the uncertainty on the energy bias and energy resolution59,60, the value of Qββ, the natural isotopic abundance of 130Te, and the reconstruction, anti-coincidence, PSD and containment efficiencies. We evaluate their separate effects on the 0νββ rate by adding nuisance parameters to the fit one at a time and studying both the effect on the posterior global mode \({\hat{{\Gamma }}}_{0\nu }\) and the marginalized 90% CI limit on Γ0ν.
A list of the systematics and priors is reported in Extended Data Table 1. The efficiencies and the isotopic abundance are multiplicative terms on our expected signal, so the effect of each is reported as a relative effect on Γ0ν. By contrast, the uncertainties on Qββ, the energy bias, and the resolution scaling have a non-trivial relation to the signal rate; therefore, we report the absolute effect of each on Γ0ν. The dominant effect is due to the uncertainty on the energy bias and resolution scaling in physics data. We account for possible correlations between the nuisance parameters by including all of them in the fit simultaneously.
We chose a uniform prior on our physical observable of interest Γ0ν, which means we treat any number of signal events as equally likely. Other possible uninformative choices could be considered appropriate, as well. Because the result of any Bayesian analysis depends to some extent on the choice of the priors, we checked how other reasonable priors affect our result57. We considered: a uniform prior on \(\sqrt{{{\Gamma }}_{0\nu }}\), equivalent to a uniform prior on mββ and also equivalent to using the Jeffreys prior; a scale-invariant uniform prior on logΓ0ν; and a uniform prior on 1/Γ0ν, equivalent to a uniform prior on \({T}_{1/2}^{0\nu }\).
These priors are all undefined at Γ0ν = 0, so we impose a lower cut-off of Γ0ν > 10−27 yr−1, which with the given exposure corresponds to approximately one signal event. The case with a uniform prior on \(\sqrt{{{\Gamma }}_{0\nu }}\) gives the smallest effect, and strengthens the limit by 25%, whereas the flat prior on 1/Γ0ν provides the largest effect, increasing the limit on \({T}_{1/2}^{0\nu }\) by a factor of 4. In fact, all these priors weigh the small values of Γ0ν more. Therefore, our choice of a flat prior on Γ0ν provides the most conservative result.
We compute the 0νββ exclusion sensitivity by generating a set of 104 toy experiments with the background-model, that is, including only the 60Co and linear background components. The toys are split into 15 datasets with exposure and background rates obtained from the background-only fits to our actual data. We fit each toy with the signal-plus-background model, and extract the distribution of 90% CI limits, shown in Extended Data Fig. 4.
We perform the frequentist analysis using the Rolke method61, obtaining a lower limit on the process half-life of \({T}_{1/2}^{0\nu } > 2.6\times {10}^{25}\,{\rm{yr}}\) (90% CI). The profile likelihood function ℒ for Γ0ν is retrieved from the full Markov chain produced by the Bayesian analysis tool. The non-uniform priors on the systematic effects in the Bayesian fit are thus incorporated into the frequentist result as well. We extract a 90% confidence interval on Γ0ν by treating −2logℒ as an approximate χ2 distribution with one degree of freedom. The lower limit on \({T}_{1/2}^{0\nu }\) comes from the corresponding upper edge of the confidence interval on Γ0ν. Applying the same method to the toy experiments, we find a median exclusion sensitivity of \({T}_{1/2}^{0\nu } > 2.9\times {10}^{25}\,{\rm{yr}}\).
Data availability
The data generated during this analysis and shown in paper figures are available in ASCII format (CSV) as Source Data in the repository https://cuore.lngs.infn.it/en/publications/collaborationpapers. Additional information is available upon request by contacting the CUORE Collaboration.
Change history
22 September 2022
In the PDF version of this article initially published, spurious “–1” exponents appeared after year (“yr”) in the second-to-last “Data analysis and results” section following median exclusion sensitivity and process half-life expressions; the exponents are removed from the PDF while the HTML version remains correct.
References
Majorana, E. Theory of the symmetry of electrons and positrons [in Italian]. Nuovo Cim. 14, 171–184 (1937).
Fukugita, M. & Yanagida, T. Baryogenesis without grand unification. Phys. Lett. B 174, 45 (1986).
CUORE Collaboration. . First results from CUORE: a search for lepton number violation via 0νββ decay of 130Te. Phys. Rev. Lett. 120, 132501 (2018).
Vissani, F. What is matter according to particle physics, and why try to observe its creation in a lab? Universe 7, 61 (2021).
Bilenky, S. M. & Giunti, C. Neutrinoless double-beta decay: a probe of physics beyond the Standard Model. Int. J. Mod. Phys. A 30, 1530001 (2015).
GERDA Collaboration. Final results of GERDA on the search for neutrinoless double-β decay. Phys. Rev. Lett. 125, 252502 (2020).
Majorana Collaboration. A search for neutrinoless double-beta decay in 76Ge with 26 kg yr of exposure from the Majorana Demonstrator. Phys. Rev. C 100, 025501 (2019).
EXO-200 Collaboration. Search for neutrinoless double-β decay with the complete EXO-200 dataset. Phys. Rev. Lett. 123, 161802 (2019).
KamLAND-Zen Collaboration. Search for Majorana neutrinos near the inverted mass hierarchy region with KamLAND-Zen. Phys. Rev. Lett. 117, 082503 (2016).
Arnaboldi, C. et al. CUORE: a Cryogenic Underground Observatory for Rare Events. Nucl. Instrum. Meth. A 518, 775–798 (2004).
Artusa, D. R. et al. Searching for neutrinoless double-beta decay of 130Te with CUORE. Adv. High Energy Phys. 2015, 879871 (2015).
Brofferio, C. & Dell’Oro, S. The saga of neutrinoless double beta decay search with TeO2 thermal detectors. Rev. Sci. Instrum. 89, 121502 (2018).
Fehr, M. A., Rehkamper, M. & Halliday, A. N. Application of MC-ICPMS to the precise determination of tellurium isotope compositions in chondrites, iron meteorites and sulfides. Int. J. Mass Spectrom. 232, 83–94 (2004).
Rahaman, S. et al. Double-beta decay Q values of 116Cd and 130Te. Phys. Lett. B 703, 412–416 (2011).
Arnaboldi, C. et al. Production of high purity TeO2 single crystals for the study of neutrinoless double beta decay. J. Cryst. Growth 312, 2999–3008 (2010).
Enss, C. & McCammon, D. Physical principles of low temperature detectors: ultimate performance limits and current detector capabilities. J. Low Temp. Phys. 151, 5–24 (2008).
Haller, E. E., Palaio, N. P., Rodder, M., Hansen, W. L. & Kreysa, E. NTD germanium: a novel material for low temperature bolometers. In Neutron Transmutation Doping of Semiconductor Materials (ed. Larrabee, R. D.) 21–36 (Springer, 1984).
Andreotti, E. et al. Production, characterization, and selection of the heating elements for the response stabilization of the CUORE bolometers. Nucl. Instrum. Meth. A 664, 161–170 (2012).
Alfonso, K. et al. A high precision pulse generation and stabilization system for bolometric experiments. J. Instrum. 13, P02029 (2018).
Pattavina, L. et al. Radiopurity of an archeological Roman lead cryogenic detector. Eur. Phys. J. A 55, 127 (2019).
Alessandria, F. et al. Validation of techniques to mitigate copper surface contamination in CUORE. Astropart. Phys. 45, 13–22 (2013).
Proceedings of the International Conference on Low Temperature Physics. Nature 168, 939–940 (1951).
Adams, D. Q. et al. CUORE opens the door to tonne-scale cryogenics experiments. Prog. Part. Nucl. Phys. 122, 103902 (2022).
Alduino, C. et al. CUORE-0 detector: design, construction and operation. J. Instrum. 11, P07009 (2016).
Alduino, C. et al. The CUORE cryostat: an infrastructure for rare event searches at millikelvin temperatures. Cryogenics 102, 9–21 (2019).
D’Addabbo, A. et al. An active noise cancellation technique for the CUORE pulse tube cryocoolers. Cryogenics 93, 56–65 (2018).
Arnaboldi, C. et al. A front-end electronic system for large arrays of bolometers. J. Instrum. 13, P02026 (2018).
Di Domizio, S. et al. A data acquisition and control system for large mass bolometer arrays. J. Instrum. 13, P12003 (2018).
Di Domizio, S., Orio, F. & Vignati, M. Lowering the energy threshold of large-mass bolometric detectors. J. Instrum. 6, P02007 (2011).
CUORE Collaboration. Analysis techniques for the evaluation of the neutrinoless double-β decay lifetime in 130Te with the CUORE-0 detector. Phys. Rev. C 93, 045503 (2016).
Adams, D. Q. et al. Measurement of the 2νββ decay half-life of 130Te with CUORE. Phys. Rev. Lett. 126, 171801 (2021).
CUORE Collaboration. Improved limit on neutrinoless double-beta decay in 130Te with CUORE. Phys. Rev. Lett. 124, 122501 (2020).
Alduino, C. et al. The projected background for the CUORE experiment. Eur. Phys. J. C 77, 543 (2017).
Menéndez, J. et al. Disassembling the nuclear matrix elements of the neutrinoless beta beta decay. Nucl. Phys. A 818, 139–151 (2009).
Šimkovic, F. et al. 0νββ and 2νββ nuclear matrix elements, quasiparticle random-phase approximation, and isospin symmetry restoration. Phys. Rev. C 87, 045501 (2013).
López Vaquero, N., Rodríguez, T. R. & Egido, J. L. Shape and pairing fluctuations effects on neutrinoless double beta decay nuclear matrix elements. Phys. Rev. Lett. 111, 142501 (2013).
Neacsu, A. & Horoi, M. Shell model studies of the 130Te neutrinoless double-beta decay. Phys. Rev. C 91, 024309 (2015).
Yao, J. M., Song, L. S., Hagino, K., Ring, P. & Meng, J. Systematic study of nuclear matrix elements in neutrinoless double-β decay with a beyond-mean-field covariant density functional theory. Phys. Rev. C 91, 024316 (2015).
Barea, J., Kotila, J. & Iachello, F. 0νββ and 2νββ nuclear matrix elements in the interacting boson model with isospin restoration. Phys. Rev. C 91, 034304 (2015).
Hyvärinen, J. & Suhonen, J. Nuclear matrix elements for 0νββ decays with light or heavy Majorana-neutrino exchange. Phys. Rev. C 91, 024613 (2015).
The CUPID Interest Group. CUPID pre-CDR. Preprint at https://arxiv.org/abs/1907.09376 (2019).
Armengaud, E. et al. The CUPID-Mo experiment for neutrinoless double-beta decay: performance and prospects. Eur. Phys. J. C 80, 44 (2020).
Azzolini, O. et al. Final result of CUPID-0 phase I in the search for the 82Se neutrinoless double-β decay. Phys. Rev. Lett. 123, 032501 (2019).
Alenkov, V. et al. First results from the AMoRE-Pilot neutrinoless double beta decay experiment. Eur. Phys. J. C 79, 791 (2019).
SuperCDMS Collaboration. Projected sensitivity of the SuperCDMS SNOLAB experiment. Phys. Rev. D 95, 082002 (2017).
CRESST Collaboration. First results from the CRESST-III low-mass dark matter program. Phys. Rev. D 100, 102002 (2019).
Pattavina, L., Ferreiro Iachellini, N. & Tamborra, I. Neutrino observatory based on archaeological lead. Phys. Rev. D 102, 063001 (2020).
NUCLEUS Collaboration. Exploring CEνNS with NUCLEUS at the Chooz nuclear power plant. Eur. Phys. J. C 79, 1018 (2019).
Wilen, C. D. et al. Correlated charge noise and relaxation errors in superconducting qubits. Nature 594, 369–373 (2021).
Cardani, L. et al. Reducing the impact of radioactivity on quantum circuits in a deep-underground facility. Nat. Commun. 12, 2733 (2021).
Gatti, E. & Manfredi, P. F. Processing the signals from solid state detectors in elementary particle physics. Riv. Nuovo Cim. 9, 1–146 (1986).
CUORE Collaboration. Low energy analysis techniques for CUORE. Eur. Phys. J. C 77, 857 (2017).
Campani, A. et al. Lowering the energy threshold of the CUORE experiment: benefits in the surface alpha events reconstruction. J. Low Temp. Phys. 200, 321–330 (2020).
Alessandrello, A. et al. Methods for response stabilization in bolometers for rare decays. Nucl. Instrum. Meth. A 412, 454–464 (1998).
Alduino, C. et al. Measurement of the two-neutrino double-beta decay half-life of 130Te with the CUORE-0 experiment. Eur. Phys. J. C 77, 13 (2017).
Huang, R. et al. Pulse shape discrimination in CUPID-Mo using principal component analysis. J. Instrum. 16, P03032 (2021).
Huang, R. G. Searching for 0νββ Decay with CUORE and CUPID. PhD thesis, Univ. California, Berkeley (2021).
Caldwell, A., Kollár, D. & Kröninger, K. BAT – the Bayesian analysis toolkit. Comput. Phys. Commun. 180, 2197–2209 (2009).
Fantini, G. Search for Double Beta Decay of 13Te to the 0+ States of 130Xe with the CUORE Experiment. PhD thesis, Gran Sasso Science Institute (2020).
Campani, A. The Search for Neutrinoless Double Beta Decay of 130Te and 120Te with the CUORE Experiment. PhD thesis, Univ. Genova (2021).
Rolke, W. A. & López, A. M. Confidence intervals and upper bounds for small signals in the presence of background noise. Nucl. Instrum. Meth. A 458, 745–758 (2001).
Acknowledgements
We thank the directors and staff of the Laboratori Nazionali del Gran Sasso and the technical staff of our laboratories. This work was supported by the Istituto Nazionale di Fisica Nucleare (INFN); the National Science Foundation under grant nos. NSF-PHY-0605119, NSF-PHY-0500337, NSF-PHY-0855314, NSF-PHY-0902171, NSF-PHY-0969852, NSF-PHY-1614611, NSF-PHY-1307204, NSF-PHY-1314881, NSF-PHY-1401832 and NSF-PHY-1913374; and Yale University. This material is also based upon work supported by the US Department of Energy (DOE) Office of Science under contract nos. DE-AC02-05CH11231 and DE-AC52-07NA27344; by the DOE Office of Science, Office of Nuclear Physics under contract nos. DE-FG02-08ER41551, DE-FG03-00ER41138, DE-SC0012654, DE-SC0020423, DE-SC0019316; and by the EU Horizon 2020 research and innovation programme under Marie Skłodowska-Curie Grant agreement no. 754496. This research used resources of the National Energy Research Scientific Computing Center (NERSC). This work makes use of both the DIANA data analysis and APOLLO data-acquisition software packages, which were developed by the CUORICINO, CUORE, LUCIFER and CUPID-0 collaborations.
Author information
Authors and Affiliations
Consortia
Contributions
All listed authors have contributed to the present publication. The different contributions span from the design and construction of the detector and of the cryogenic system to the acquisition and analysis of data. The manuscript underwent an internal review process extended to the whole collaboration, and all authors approved its final version; the authors’ names are listed alphabetically.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Peer review
Peer review information
Nature thanks the anonymous reviewers for their contribution to the peer review of this work. Peer reviewer reports are available.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Extended data figures and tables
Extended Data Fig. 1 Working principle of the cryogenic calorimeter.
Left, simplified calorimeter thermal model. The detector is modelled as a single object with heat capacity C coupled to the heat bath (with constant temperature T0) through the thermal conductance G. The NTD thermistor for signal readout is glued to the absorber. Right, example of a CUORE pulse from the 2,615-keV calibration line: T0 corresponds to the baseline height, the pulse amplitude is proportional to the deposited energy, and the decay time depends on the value of C/G.
Extended Data Fig. 2 Roman lead.
Top left, the recovery of the lead bricks from the Sardinian sea. Bottom left, the ingot inscriptions were cut and preserved, and the ingot bodies were used for the CUORE internal lead shield. Right, lateral view of the internal lead shield20.
Extended Data Fig. 3 Pulse shape discrimination.
Effect of the PSD cut on calibration data around the 2,615-keV line (left) and on physics data near Qββ (right). In calibration data, the anti-coincidence is not applied in order to maximize the statistics on the γ peaks, and the PSD mostly removes pileup events (events with more than one energy deposit in the time window). In physics data, the PSD mostly eliminates random noise events, which can correspond to either physical events with excessive noise or to noise-induced events with non-physical pulse shapes. Such events appear randomly across the energy spectrum, so the cut mostly acts on the continuum.
Extended Data Fig. 4 Optimum trigger and statistical analysis.
Top left, distribution of energy thresholds at 90% trigger efficiency for the optimum trigger algorithm in a single dataset. The 40-keV analysis threshold is indicated by the vertical line. Top right, 90% CI exclusion limits on \({T}_{1/2}^{0\nu }\) from an ensemble of 104 toy experiments generated with the background-only model, with background rates obtained from the background-only fit to the data. The median exclusion sensitivity is indicated by the orange line. Bottom left, posterior probability distribution for Γ0ν obtained from the Bayesian fit, with the 90% CI highlighted. Bottom right, Δχ2 values obtained from the profile likelihood of Γ0ν, with Δχ2 = 0 being the most-favoured value. The frequentist limit at 90% confidence level (CL) is indicated.
Extended Data Fig. 5 PCA performance.
Left, example of a normalization fit of the PCA reconstruction error versus energy for a single calorimeter and dataset. The distribution contains only events that passed the other base cuts. The second-order polynomial fit is shown in orange. Right, two example pulses from this calorimeter. The actual pulse is drawn in teal, and the corresponding reconstruction obtained by the PCA is drawn in orange. The top pulse deviates from the expected shape of a good pulse and is rejected, whereas the bottom one conforms to the expected response and is accepted.
Supplementary information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
The CUORE Collaboration. Search for Majorana neutrinos exploiting millikelvin cryogenics with CUORE. Nature 604, 53–58 (2022). https://doi.org/10.1038/s41586-022-04497-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/s41586-022-04497-4
This article is cited by
-
Ba+2 ion trapping using organic submonolayer for ultra-low background neutrinoless double beta detector
Nature Communications (2022)
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.