Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

  • Article
  • Published:

Field-resolved infrared spectroscopy of biological systems

Abstract

The proper functioning of living systems and physiological phenotypes depends on molecular composition. Yet simultaneous quantitative detection of a wide variety of molecules remains a challenge1,2,3,4,5,6,7,8. Here we show how broadband optical coherence opens up opportunities for fingerprinting complex molecular ensembles in their natural environment. Vibrationally excited molecules emit a coherent electric field following few-cycle infrared laser excitation9,10,11,12, and this field is specific to the sample’s molecular composition. Employing electro-optic sampling10,12,13,14,15, we directly measure this global molecular fingerprint down to field strengths 107 times weaker than that of the excitation. This enables transillumination of intact living systems with thicknesses of the order of 0.1 millimetres, permitting broadband infrared spectroscopic probing of human cells and plant leaves. In a proof-of-concept analysis of human blood serum, temporal isolation of the infrared electric-field fingerprint from its excitation along with its sampling with attosecond timing precision results in detection sensitivity of submicrograms per millilitre of blood serum and a detectable dynamic range of molecular concentration exceeding 105. This technique promises improved molecular sensitivity and molecular coverage for probing complex, real-world biological and medical settings.

This is a preview of subscription content, access via your institution

Access options

Rent or buy this article

Prices vary by article type

from$1.95

to$39.95

Prices may be subject to local taxes which are calculated during checkout

Fig. 1: Infrared FRS.
Fig. 2: Background quantification for detection of resonant molecular responses.
Fig. 3: Limit of detection of DMSO2 molecules dissolved in water.
Fig. 4: GMFs of human blood serum and their reproducibility.
Fig. 5: Sensitivity and specificity of FRS of complex fluids performed with bandwidth-optimized sampling.
Fig. 6: FRS of strongly absorbing living systems.

Similar content being viewed by others

Data availability

The data that support the findings of this study are available from the corresponding author upon reasonable request.

References

  1. Geyer, P. E., Holdt, L. M., Teupser, D. & Mann, M. Revisiting biomarker discovery by plasma proteomics. Mol. Syst. Biol. 13, 942 (2017).

    PubMed  PubMed Central  Google Scholar 

  2. Barth, A. & Haris, P. I. Biological and Biomedical Infrared Spectroscopy (IOS Press, 2009).

  3. Lasch, P. & Kneipp, J. Biomedical Vibrational Spectroscopy (Wiley, 2010).

  4. Baker, M. J. et al. Developing and understanding biofluid vibrational spectroscopy: a critical review. Chem. Soc. Rev. 45, 1803–1818 (2016).

    PubMed  CAS  Google Scholar 

  5. Hasin, Y., Seldin, M. & Lusis, A. Multi-omics approaches to disease. Genome Biol. 18, 83 (2017).

    PubMed  PubMed Central  Google Scholar 

  6. Chen, R. et al. Personal omics profiling reveals dynamic molecular and medical phenotypes. Cell 148, 1293–1307 (2012).

    PubMed  PubMed Central  CAS  Google Scholar 

  7. Türker-Kaya, S. & Huck, C. A review of mid-infrared and near-infrared imaging: principles, concepts and applications in plant tissue analysis. Molecules 22, 168 (2017).

    PubMed Central  Google Scholar 

  8. Doherty, J., Cinque, G. & Gardner, P. Single-cell analysis using Fourier transform infrared microspectroscopy. Appl. Spectrosc. Rev. 52, 560–587 (2017).

    ADS  CAS  Google Scholar 

  9. Laubereau, A. & Kaiser, W. Vibrational dynamics of liquids and solids investigated by picosecond light pulses. Rev. Mod. Phys. 50, 607–665 (1978).

    ADS  CAS  Google Scholar 

  10. Sell, A., Scheu, R., Leitenstorfer, A. & Huber, R. Field-resolved detection of phase-locked infrared transients from a compact Er:fiber system tunable between 55 and 107 THz. Appl. Phys. Lett. 93, 251107 (2008).

    ADS  Google Scholar 

  11. Coddington, I., Swann, W. C. & Newbury, N. R. Time-domain spectroscopy of molecular free-induction decay in the infrared. Opt. Lett. 35, 1395–1397 (2010).

    ADS  PubMed  CAS  Google Scholar 

  12. Kowligy, A. S. et al. Infrared electric field sampled frequency comb spectroscopy. Sci. Adv. 5, eaaw8794 (2019).

    ADS  PubMed  PubMed Central  CAS  Google Scholar 

  13. Wu, Q. & Zhang, X.-C. Free-space electro-optic sampling of terahertz beams. Appl. Phys. Lett. 67, 3523–3525 (1995).

    ADS  CAS  Google Scholar 

  14. Nahata, A., Weling, A. S. & Heinz, T. F. A wideband coherent terahertz spectroscopy system using optical rectification and electro-optic sampling. Appl. Phys. Lett. 69, 2321–2323 (1996).

    ADS  CAS  Google Scholar 

  15. Pupeza, I. et al. High-power sub-two-cycle mid-infrared pulses at 100 MHz repetition rate. Nat. Photon. 9, 721–724 (2015).

    ADS  CAS  Google Scholar 

  16. Gianazza, E., Miller, I., Palazzolo, L., Parravicini, C. & Eberini, I. With or without you—proteomics with or without major plasma/serum proteins. J. Proteomics 140, 62–80 (2016).

    PubMed  CAS  Google Scholar 

  17. Dębska, B. & Guzowska-Świder, B. Fuzzy definition of molecular fragments in chemical structures. J. Chem. Inf. Comput. Sci. 40, 325–329 (2000).

    PubMed  Google Scholar 

  18. Demtröder, W. Molecular Physics (Wiley, 2005).

  19. Movasaghi, Z., Rehman, S. & ur Rehman, Dr. I. Fourier transform infrared (FTIR) spectroscopy of biological tissues. Appl. Spectrosc. Rev. 43, 134–179 (2008).

    ADS  CAS  Google Scholar 

  20. Griffiths, P. R. & De Haseth, J. A. Fourier Transform Infrared Spectrometry (Wiley, 2007).

  21. Keilmann, F., Gohle, C. & Holzwarth, R. Time-domain mid-infrared frequency-comb spectrometer. Opt. Lett. 29, 1542–1544 (2004).

    ADS  PubMed  Google Scholar 

  22. Newbury, N. R., Coddington, I. & Swann, W. Sensitivity of coherent dual-comb spectroscopy. Opt. Express 18, 7929–7945 (2010).

    ADS  PubMed  CAS  Google Scholar 

  23. Villares, G., Hugi, A., Blaser, S. & Faist, J. Dual-comb spectroscopy based on quantum-cascade-laser frequency combs. Nat. Commun. 5, 5192 (2014).

    ADS  PubMed  CAS  Google Scholar 

  24. Schwaighofer, A. et al. Beyond Fourier transform infrared spectroscopy: external cavity quantum cascade laser-based mid-infrared transmission spectroscopy of proteins in the amide I and amide II region. Anal. Chem. 90, 7072–7079 (2018).

    PubMed  CAS  Google Scholar 

  25. Haas, J., Catalán, E. V., Piron, P., Karlsson, M. & Mizaikoff, B. Infrared spectroscopy based on broadly tunable quantum cascade lasers and polycrystalline diamond waveguides. Analyst 143, 5112–5119 (2018).

    ADS  PubMed  CAS  Google Scholar 

  26. Ollesch, J. et al. An infrared spectroscopic blood test for non-small cell lung carcinoma and subtyping into pulmonary squamous cell carcinoma or adenocarcinoma. Biomed. Spectrosc. Imaging 5, 129–144 (2016).

    Google Scholar 

  27. Brandstetter, M., Volgger, L., Genner, A., Jungbauer, C. & Lendl, B. Direct determination of glucose, lactate and triglycerides in blood serum by a tunable quantum cascade laser-based mid-IR sensor. Appl. Phys. B 110, 233–239 (2013).

    ADS  CAS  Google Scholar 

  28. Baker, M. J. et al. Using Fourier transform IR spectroscopy to analyze biological materials. Nat. Protocols 9, 1771–1791 (2014).

    PubMed  CAS  Google Scholar 

  29. Martin, M. C. et al. 3D spectral imaging with synchrotron Fourier transform infrared spectro-microtomography. Nat. Methods 10, 861–864 (2013).

    PubMed  CAS  Google Scholar 

  30. Rohleder, D. et al. Comparison of mid-infrared and Raman spectroscopy in the quantitative analysis of serum. J. Biomed. Opt. 10, 031108 (2005).

    ADS  PubMed  CAS  Google Scholar 

  31. Bhargava, R. Infrared spectroscopic imaging: the next generation. Appl. Spectrosc. 66, 1091–1120 (2012).

    ADS  PubMed  PubMed Central  CAS  Google Scholar 

  32. Quaroni, L., Zlateva, T., Wehbe, K. & Cinque, G. Infrared imaging of small molecules in living cells: from in vitro metabolic analysis to cytopathology. Faraday Discuss. 187, 259–271 (2016).

    ADS  PubMed  CAS  Google Scholar 

  33. Bonnier, F. et al. Ultra-filtration of human serum for improved quantitative analysis of low molecular weight biomarkers using ATR-IR spectroscopy. Analyst 142, 1285–1298 (2017).

    ADS  PubMed  CAS  Google Scholar 

  34. Haas, J. & Mizaikoff, B. Advances in mid-infrared spectroscopy for chemical analysis. Annu. Rev. Anal. Chem. 9, 45–68 (2016).

    Google Scholar 

  35. Lu, R. et al. High-sensitivity infrared attenuated total reflectance sensors for in situ multicomponent detection of volatile organic compounds in water. Nat. Protocols 11, 377–386 (2016).

    PubMed  CAS  Google Scholar 

  36. Haase, K., Kröger-Lui, N., Pucci, A., Schönhals, A. & Petrich, W. Advancements in quantum cascade laser-based infrared microscopy of aqueous media. Faraday Discuss. 187, 119–134 (2016).

    ADS  PubMed  CAS  Google Scholar 

  37. Haase, K., Kröger-Lui, N., Pucci, A., Schönhals, A. & Petrich, W. Real-time mid-infrared imaging of living microorganisms. J. Biophoton. 9, 61–66 (2016).

    CAS  Google Scholar 

  38. Gaida, C. et al. Watt-scale super-octave mid-infrared intrapulse difference frequency generation. Light Sci. Appl. 7, 94 (2018).

    ADS  PubMed  PubMed Central  Google Scholar 

  39. Seidel, M. et al. Multi-watt, multi-octave, mid-infrared femtosecond source. Science Advances 4, eaaq1526 (2018).

    ADS  PubMed  PubMed Central  Google Scholar 

  40. Butler, T. P. et al. Watt-scale 50-MHz source of single-cycle waveform-stable pulses in the molecular fingerprint region. Opt. Lett. 44, 1730–1733 (2019).

    ADS  PubMed  CAS  Google Scholar 

  41. Pupeza, I. et al. Field-resolved spectroscopy in the molecular fingerprint region. In Lasers and Electro-Optics Europe & European Quantum Electronics Conf. (CLEO/Europe-EQEC) https://doi.org/10.1109/CLEOE-EQEC.2017.8086859 (IEEE, 2017).

  42. Huber, M. et al. Detection sensitivity of field-resolved spectroscopy in the molecular fingerprint region. In Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC) https://doi.org/10.1109/CLEOE-EQEC.2017.8086921 (IEEE, 2017).

  43. Timmers, H. et al. Molecular fingerprinting with bright, broadband infrared frequency combs. Optica 5, 727–732 (2018).

    ADS  CAS  Google Scholar 

  44. Muraviev, A. V., Smolski, V. O., Loparo, Z. E. & Vodopyanov, K. L. Massively parallel sensing of trace molecules and their isotopologues with broadband subharmonic mid-infrared frequency combs. Nat. Photon. 12, 209–214 (2018).

    ADS  CAS  Google Scholar 

  45. Udem, T., Holzwarth, R. & Hänsch, T. W. Optical frequency metrology. Nature 416, 233–237 (2002).

    ADS  PubMed  CAS  Google Scholar 

  46. Ye, J. & Cundiff, S. T. Femtosecond Optical Frequency Comb: Principle, Operation, And Applications (Springer, 2005).

  47. Schweinberger, W. et al. Interferometric delay tracking for low-noise Mach-Zehnder-type scanning measurements. Opt. Express 27, 4789–4798 (2019).

    ADS  PubMed  CAS  Google Scholar 

  48. Schubert, O. et al. Rapid-scan acousto-optical delay line with 34 kHz scan rate and 15 as precision. Opt. Lett. 38, 2907–2910 (2013).

    ADS  PubMed  CAS  Google Scholar 

  49. Birarda, G. et al. IR-Live: fabrication of a low-cost plastic microfluidic device for infrared spectromicroscopy of living cells. Lab Chip 16, 1644–1651 (2016).

    PubMed  CAS  Google Scholar 

  50. Max, J.-J. & Chapados, C. Glucose and fructose hydrates in aqueous solution by IR spectroscopy. J. Phys. Chem. A 111, 2679–2689 (2007).

    PubMed  CAS  Google Scholar 

  51. Tsurumachi, N., Fuji, T., Kawato, S., Hattori, T. & Nakatsuka, H. Interferometric observation of femtosecond free induction decay. Opt. Lett. 19, 1867–1869 (1994).

    ADS  PubMed  CAS  Google Scholar 

  52. Gallot, G. & Grischkowsky, D. Electro-optic detection of terahertz radiation. J. Opt. Soc. Am. B 16, 1204–1212 (1999).

    ADS  CAS  Google Scholar 

  53. Hobbs, P. C. D. Ultrasensitive laser measurements without tears. Appl. Opt. 36, 903–920 (1997).

    ADS  PubMed  CAS  Google Scholar 

  54. Foltynowicz, A., Ban, T., Masłowski, P., Adler, F. & Ye, J. Quantum-noise-limited optical frequency comb spectroscopy. Phys. Rev. Lett. 107, 233002 (2011).

    ADS  PubMed  Google Scholar 

  55. Buberl, T. Broadband interferometric subtraction of optical fields. Opt. Express 27, 2432–2443 (2019).

    ADS  PubMed  CAS  Google Scholar 

  56. Tomberg, T., Muraviev, A., Ru, Q. & Vodopyanov, K. L. Background-free broadband absorption spectroscopy based on interferometric suppression with a sign-inverted waveform. Optica 6, 147–151 (2019).

    ADS  CAS  Google Scholar 

  57. Fritsch, K., Poetzlberger, M., Pervak, V., Brons, J. & Pronin, O. All-solid-state multipass spectral broadening to sub-20 fs. Opt. Lett. 43, 4643–4646 (2018).

    ADS  PubMed  CAS  Google Scholar 

  58. Schulte, J., Sartorius, T., Weitenberg, J., Vernaleken, A. & Russbueldt, P. Nonlinear pulse compression in a multi-pass cell. Opt. Lett. 41, 4511–4514 (2016).

    ADS  PubMed  CAS  Google Scholar 

  59. Huber, M. et al. Active intensity noise suppression for a broadband mid-infrared laser source. Opt. Express 25, 22499–22509 (2017).

    ADS  PubMed  CAS  Google Scholar 

  60. Lanin, A. A., Voronin, A. A., Fedotov, A. B. & Zheltikov, A. M. Time-domain spectroscopy in the mid-infrared. Sci. Rep. 4, 1–8 (2014).

    Google Scholar 

Download references

Acknowledgements

We thank D. Gerz, A. Zigman Kohlmaier, L. Fuerst and I. Kosse for their contributions and help with the measurements. We acknowledge the support of the Max Planck Society, the Center for Advanced Laser Applications of the Ludwig-Maximilians University and the King Saud University via the Researchers Supporting Project (NSRSP-2019/1).

Author information

Authors and Affiliations

Authors

Contributions

I.P., M.H., M.T., W.S., S.A.H., C.H., E.F., A. Apolonski, A. Azzeer, M.Z. and F.K. conceived the experiments. I.P., M.H., M.T., W.S., S.A.H., C.H., K.F., M.P., L.V., T.A, K.V.K., N.K., V.P., O.P., M.Z. and F.K. designed the experiments and analysed the experimental data. M.H., F.F. and M.Z. prepared the living systems. S.A.H., K.F., M.P. and O.P. designed and built the few-cycle near-infrared femtosecond laser source. I.P., M.H., W.S., S.A.H., C.H., L.V., V. P. and N.K. developed the optical system for the generation and electro-optic detection of waveform-stable MIR radiation. All authors contributed to evaluating the results and writing the manuscript.

Corresponding authors

Correspondence to Ioachim Pupeza or Ferenc Krausz.

Ethics declarations

Competing interests

The authors declare no competing interests.

Additional information

Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Extended data figures and tables

Extended Data Fig. 1 Comparison of FTS with FRS.

a, Schematic of FTS. b, Schematic of FRS. c, Portions of the background signal contributed by the sample response to the FTS (blue, first right-hand-side term of equation (1a)) and to the FRS (red, first right-hand-side term of equation (1b)) signals at a fixed delay (τ = 1,500 fs). For illustration purposes, the nonlinear upconversion efficiency was set to 1 and the ‘carved out’ effective window time length to 50 fs (without loss of generality). Example parameters: 190-fs Gaussian excitation pulse and 1,139-cm−1 DMSO2 absorption (see Extended Data Table 1).

Source Data

Extended Data Fig. 2 Detection dynamic range and linearity of the instrument response.

a, Infrared excitation pulse (normalized to maximum), recorded with attenuating optical density (OD) filters instead of the cuvette in the beam path, for increasing attenuation and measurement time T. A 1,200-fs scan range and T = 16 s and T = 1,600 s were considered. Small variations of the pulse shape for different attenuations are attributed to slight dispersion variations among the OD filters. The attenuation-independent pulse shape confirms the instrument linearity over the entire parameter range considered. b, c, Spectral intensity (normalized to the maximum of the attenuation-free measurement) and phase of the signals in a, respectively. The detection noise floors in b were obtained by blocking the MIR signal and evaluating the mean of the (white) noise in the considered spectral range, and confirm the linear decrease of the noise floor with T. For the data in c, for all time-domain waveforms a super-Gaussian filter (width 700 fs, order 20) was applied.

Source Data

Extended Data Fig. 3 Experimental setup.

See subsection ‘High-power femtosecond oscillator and generation of waveform-stable MIR Pulses’ in Supplementary Information section I for details. a, HWP, half-wave plate; QWP, quarter-wave plate; IDFG, intra-pulse difference frequency generation; IDT, interferometric delay tracking; Ge, germanium beam combiner. All steering mirrors for the MIR beam were gold-coated. In the bandwidth-optimized instrument setting, four custom dispersive mirrors were added to the MIR beam path (see text). The pulse was temporally compressed with customized dispersive optics. Pulse compression. EOS traces of the excitation pulse transmitted through water in the bandwidth-optimized instrument setting, with (blue) and without (red) four dispersive mirrors in the MIR beam path. c, As in b but on a logarithmic scale, visualizing the improved roll-off of the signal achieved with the dispersive optics.

Source Data

Extended Data Fig. 4 Contributions to quantum efficiency in electro-optic sampling.

a, Frequency-resolved measurement of the noise of the balanced detection (black), and calculated shot noise (red). The dashed line indicates the lock-in frequency, and its peak stems from the chopper. b, Comparison of MIR power depletion after EOS crystal for the two different crystal thicknesses. The oscillations originate from interferences of the MIR pulse incident to the EOS crystal and MIR radiation generated therein (these oscillations do not affect the performance of EOS detection).

Source Data

Extended Data Fig. 5 Measurement of noise contributions for the estimation of the performance of FTS with our femtosecond-laser-based source, our mechanical scan, and state-of-the-art infrared detection.

a, The setup mimics a FTS setup in the Mach–Zehnder configuration, with balanced lock-in detection. For lock-in frequency modulation, a mechanical chopper is placed in the ‘sample arm’. The two arms are recombined with a 50:50 beam splitter. The two outputs are detected with two independent MIR detectors (see text for details). The power impinging on each detector was limited to 450 mW, corresponding to a detector output voltage of 20 V. The relative intensity noise (RIN) spectrum of the source is recorded with an FFT-Analyzer in the range 0.1–100 kHz (before balanced detection). Balanced lock-in detection is performed with a lock-in amplifier with differential input. The beam block was used in the measurements shown in c. b, RIN spectrum of the free-running (red curve) and intensity-stabilized (blue curve) MIR beam (before the interferometer). The integrated RIN of the stabilized source from 1 Hz and 100 kHz is as low as 0.04%. c, Demodulated (after lock-in detection with a time constant of 1.6 ms and 4th-order filter) time-domain trace of detector noise (grey), local-oscillator signal with sample arm blocked (turquoise) and of the combination of both interferometer arms impinging on the balanced detection (blue). The inset shows a 1-second section of the signals, for a detailed comparison of the local-oscillator noise and the detector noise.

Source Data

Extended Data Fig. 6 Simulations of time-domain decay of a molecular Lorentzian oscillator.

a, Fit of a Lorentzian oscillator to the 1,139 cm−1 absorption of (low-concentration) DMSO2. Black line, intensity transmission through pure, molecular DMSO2, determined by referencing the transmission spectrum of a 1 mg ml−1 solution to that of water, measured via FTIR, and normalizing to a 1-µm path. Green line, least-squares fit (1,080–1,190 cm−1) of a Lorentzian oscillator to the 1,139 cm−1 absorption, yielding a full width at half depth of 13.47 cm−1 and an absorption coefficient α = 11.96 cm−1. The numerical example shows the instantaneous and resonant parts of the electric field as described by equations (1) to (4) in Supplementary Information section II. The initial pulse is a Gaussian pulse with an intensity envelope (full width at half maximum) of 190 fs. The Lorentzian absorption band has a peak of α2z with α2 = 0.0024 cm−1, corresponding to a 200 ng ml−1 solution of DMSO2 in water, and a width δυ = 13.47 cm−1. These values were obtained from fitting a Lorentzian absorber to the 1,139 cm−1 band of the transmission spectrum of a 1 mg ml−1 solution obtained with FTIR and linear extrapolation to a concentration 5,000 times lower. b, Time-domain representation of the normalized envelope functions of the electric fields described (see key). A value of tB = 1.5 ps is chosen. The green vertical bars indicate the boundaries of the band-pass-filtered resonant response shown in green: 1.5 ps and 4 ps. c, Magnitudes of the Fourier transforms of the envelopes shown in a, normalized to C. At the absorption maximum, the discrepancy between the resonant response as in Supplementary Information section 2 and its approximation as in Supplementary Information section 3 is 1%, justifying this convenient approximation. The error introduced by band-pass filtering the resonant response between 1.5 ps and 4 ps compared to the high-pass time-filtered signal is 4%.

Source Data

Extended Data Fig. 7 Spectral intensity of the Fourier-transformed temporal fingerprints of DMSO2.

Spectral intensity is shown for different concentrations, after high-pass-time-filtering at tB = 1,500 fs and subtraction of pure water reference, normalized to the spectral intensity of the reference pulse. Green dashed lines, modelled Lorentzian oscillator with the parameters derived from the fit in Extended Data Fig. 6. This model agrees excellently with the measured fingerprints, and confirms the minimum detectable absorbance predicted by equation (2) as well as the linear response of the instrument.

Source Data

Extended Data Fig. 8 Principal component analysis.

ad, Comparison of the loading vectors for the first principal component for the FTIR data (a) and the FRS data (b) from the serum spiking experiment, with the pre-processed GMF data (see text) of the FTIR (c) and FRS (d) measurements of a 1 mg ml−1 DMSO2 solution. We note that the FRS spectra are complex, so the real and imaginary parts were considered separately (and stitched to single vectors). e, Figure of merit (FOM) (colour scale in arbitrary units; see Supplementary Information section VI) quantifying the separation of classes according to the first principal component (the lower the FOM, the better the separation), evaluated for a large range of the beginning time tB and time window length Δt. The cross indicates parameters yielding optimum separation. fi, Comparison of the loading vectors for the first principal component for the FTIR data (f) and the FRS data (g) from the sugar mixture experiment, with the pre-processed GMF data of the FTIR (h) and FRS (i). For the latter, the difference of the spectra of the 50/50 mixture and the pure maltose solution is shown. The real and imaginary parts were considered separately. j, FOM quantifying the separation of classes according to the first principal component, in analogy to e.

Source Data

Extended Data Fig. 9 Absorption spectra of 10 mg ml−1 aqueous solutions of maltose and melibiose, measured by FRS and FTIR.

The difference in total absorption is due to the differing cuvette thickness. a, FRS; b, FTIR. OD, optical density.

Source Data

Extended Data Table 1 Parameters for numerical estimation of the sensitivity of FTS implemented with our infrared source

Supplementary information

Supplementary Information

This file contains Supplementary Information sections 1–7 and Supplementary References.

Video 1: A qualitative explanation of the emergence of the global molecular fingerprint.

Source data

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Pupeza, I., Huber, M., Trubetskov, M. et al. Field-resolved infrared spectroscopy of biological systems. Nature 577, 52–59 (2020). https://doi.org/10.1038/s41586-019-1850-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1038/s41586-019-1850-7

This article is cited by

Comments

By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.

Search

Quick links

Nature Briefing

Sign up for the Nature Briefing newsletter — what matters in science, free to your inbox daily.

Get the most important science stories of the day, free in your inbox. Sign up for Nature Briefing