Introduction

Bending sensors provide an electrical signal as a function of the bending radius or curvature.1 Such sensors offer an extremely versatile sensing platform capable of measuring changes of various physical quantities. They can be made lightweight, low-cost, and robust and tolerate vibration, thermal shock and stretching without electromagnetic interference or sensor occlusion.2 The application areas of bending sensors are rapidly increasing, including medical,3,4 automotive,5 industrial,6,7 physical activity measurements,6,8 and human–machine interactions.9 In case of passive resistive bending sensors, an electrically conductive pattern or electrode is fabricated on top of a flexible substrate, and changes its resistance upon substrate bending. These electrodes have been realized by on carbon-based materials (powder,10 ink,11 and particles12), transition metals (silver,13 copper,14 and platinum15), and conductive polymers,16 which determine the basic electrical properties of the sensor.

In this paper, we exploit the piezoresistance of graphene electrodes printed on flexible polyimide (PI) films. Graphene has been extensively exploited recently as an alternative to traditional materials, due to its superior properties, such as high conductivity, flexibility, transparency, and biocompatibility,17,18 There is a number of reports investigating electromechanical properties of the graphene based on CVD,19,20,21 mechanically exfoliated graphene,22,23 graphene oxide,24,25,26 and hydrogenated graphene oxide.20,27 The intrinsic piezoresistivity of single-layer graphene is rather limited as the hexagonal mesh of graphene can withstand strains only below ~0.7% with gauge factors (GF) of ~1.4-2.28,29,30,31 Meanwhile, the responsivity of multilayered structures, such as graphene oxide24,25,26 and hydrogenated graphene oxide is significantly higher.20,27 The high variation of the electrical resistance of multilayer samples under strain was explained by the displacement of the layers and changing their overlapping area, which provides the ability to use these structures for force and strain sensors.20

In 2014, it was discovered that direct lasing of PI films leads to the formation of 3D porous graphene,32,33,34 by a photothermal process associated with a localized high temperature, the pressure produced by laser irradiation and easy absorption of long-wavelength radiation. This process enables the development of LIG bending sensors that are mechanically flexible, lightweight, robust, and multifunctional. Several studies on LIG strain sensors have investigated the laser power effect on the GF of the functionalized LIG,35,36,37 some focused on embedding LIG on cured elastomers,38,39,40,41 while others discovered alternative lasers that fabricate LIG,42,43 The piezoresistive properties of LIG were utilized for generating and detecting sounds,43 gesture registration,35 respiratory rate,44 and human–machine interface.40 The LIG sensors in this study are used for the detection of curvature, force, deflection, and flow. The LIG bending sensor can also operate in harsh conditions, and is fabricated by a simple process without the requirement for a clean room, solvents, and subsequent treatments or other supporting processes. The sensor is customized for different applications simply by adopting the geometry, while achieving a homogeneous bidirectional response, temperature compensation, and high accuracy.

Here, we demonstrate the versatility and potential of LIG sensors, and challenge their performance under harsh conditions. In particular, we used LIG sensors as a wearable device to monitor body movements of marine animals in various locations in the Red Sea. We did so by combining the LIG sensors with ultra-low power aquatic tags. The Red Sea is the warmest (up to 36 °C in surface waters)45 and saltiest (20% above standard ocean salinity46) of all seas, and offer conditions prone to corrosion and pressure-derived failure of electronic devices.

Speed sensing of underwater animals is especially challenging, due to the harsh conditions in the Red Sea combined with the requirement for low weight, size, and power consumption. Speed sensing of marine animals is fundamental to quantify their energy expenditure, which, in turn, is crucial for understanding their foraging behaviors, biogeography, life history, and many conservation efforts.47 Animal-attached bending sensors could provide an opportunity to observe energy expenditure by quantifying the velocity of the animal body over time.48 The most commonly employed method for speed sensing is the overall dynamic body acceleration, where a derivative of acceleration is used as a proxy for the metabolic rate.48 This indirect method suffers from the inability to estimate the energy budget in the case of stationary activities and time-varying flow velocity. Other methods have exploited turbines,49,50 paddle wheels51 rotated by ambient water flow, and reflectance of infrared light against a flexible paddle.52 Meanwhile, commercially available flow sensors use various operating principles, such as differential pressure meters,53 variable area flowmeter,54 electromagnetic,55 vortex,56 ultrasonic,57 and Coriolis mass.58 These solutions have limited capabilities, either due to fragile moving part or high installation and maintenance cost. They are also susceptible to biofouling and blockage due to an accumulation of foreign particles. Additional protective housings, employed to remedy some of these issues, increase the size, buoyancy and weight associated with the device, which has been shown to influence animal behavior, swimming, and diving performance.7 Another active research area is oriented toward obtaining spatiotemporal information of human body movements using flexible, noninvasive, cost-effective, lightweight, and low-power sensors to continuously track segments of the body over extended periods and without reducing freedom of movement. LIG bending sensors could be advantageously utilized for long-term monitoring of human movement in kinesiology, physiotherapy, rehabilitation, telehealth, or in the control of prosthetic limbs.

Results and discussion

Characterization of LIG bending sensor

The surface morphology of the carbon network patterns was qualitatively investigated by scanning electron microscopy (SEM, Quanta 600FEG Systems). A cross-sectional view of the carbon patterns on top of the PI film is shown in Fig. 1, indicating that the entire volume of the LIG is comprised highly porous nanomaterials. The structural characteristics of the porous graphene were also examined via confocal Raman spectrum (Fig. 1d), revealing three distinctive peaks at 1360 cm−1 (D-band), 1580 cm−1 (G-band), and 2720 cm−1 (2D-band) and thereby, suggesting the presence of graphene sheets in the porous structure. The G peak is related to the vibration of sp2 carbon atoms in the hexagonal plane, and its intensity is lower in monolayer graphene.59 The D peak is activated by disorder and defects and correspond to intravalley double resonance processes.60 The 2D peak is the key one in monolayer graphene that reduces and widens, as the number of layers increases.61 The XPS spectrum, shown in Fig. 1e, reveals a dominant C—C peak, with greatly suppressed C—O, C = O, and COO peaks, suggesting the dominance of sp2-carbon in LIG.47

Fig. 1
figure 1

a Cross-sectional SEM image of the porous carbon network lying on the top of polyimide (scale bar: 30 μm). b Low-magnification SEM image shows the porous morphology of LIG (scale bar: 15 μm). c High-magnification SEM image shows the graphene flakes randomly arranged and interconnected (scale bar: 5 μm). d Raman spectrum of LIG acquired with a laser wavelength of 473 nm. e High-resolution XPS spectrum of the C1s region of LIG

A typical factor used to characterize strain sensors is the Gauge factor (GF),

$${\mathrm{GF}} = \frac{{{\mathrm{d}}R/R}}{{{\mathrm{d}}l/l}} = \frac{{{\mathrm{d}}\rho /\rho }}{\varepsilon } + 1 + 2\nu ,$$
(1)

where ∆l/l is the strain, R is the resistance under zero strain, ρ is the electrical resistivity, ν is the Poisson ratio (νKapton = 0.34).62 An LIG electrode in the form of a strip with a length of 30 mm, a width of 2 mm, and initial resistance of ~0.7 kΩ was used to evaluate the GF. Both ends of the strip were fixed by sample holders (inset of Fig. 2) of an electromechanical pull tester (5900-Series, Instron Inc.), which provided a continuously increasing force and measurement of the resulting displacement. A continuous current of 1 mA was applied through the graphene strain sensor (as in all consecutive experiments) to measure the change of electrical resistance during the tensile deformation of the sensor with a Keithley 2400 Source Meter. Figure 2 reveals a linear relationship between strain and relative change in resistance. The increase in resistance is attributed to a narrow and long conductive porous structure. The GF  11.2 (Young modulus 2.1 GPa, yield strength  83 MPa) is extracted from the slope, and is in the range of the values of metal strain gauges. Note, the maximum strain applied was > 10%. The intrinsic contribution to the piezoresistivity was found to have ((dρ/ρ)/dl/l = 0.84) a positive sign, suggesting a positive piezoresistivity.

Fig. 2
figure 2

Strain-induced resistance change of LIG

Force, deflection, and flow detection

The electromechanical pull tester was used to induce deflection of the LIG sensor, as shown in the insets of Fig. 3. The resistance variation of the sensor in tension state (LIG on the convex side) has a linear relationship with the exerted force and the sensor deflection. The electrical resistance of the LIG sensor, shown in Fig. 3a (width: 7 mm, length: 7.6 mm, number of turns: 11), increases at the rate of ~2.98 Ω/mN and ~0.21 Ω/μm at room temperature. Conversely, the LIG bending sensor shows a decreasing resistance in compression state (LIG on the concave side), reducing at the rate of ~2.91 Ω/mN, ~−0.21 Ω/μm (Fig. 3). The absolute change in resistance is tailored by the number of turns of the LIG electrodes as seen in Fig. S1a. An increased number of turns with the same dimensions did not affect the normalized sensitivity, since the percentage change in resistance for a given strain for the entire LIG path is the same as for any single trace. Using shorter electrodes (7 mm) results in a higher sensitivity than longer ones (15 mm) with the same number of turns (Fig. S1b), as expected from Eq. (3).

Fig. 3
figure 3

Average resistance as a function of a force and b deflection induced during extension and compression of LIG. The error bars indicate the standard deviation. The coefficient of determination (R2) is 0.9961 during extension and 0.9984 during compression

To test the response of a LIG bending sensor to different flow rates, a setup was constructed wherein a fluid flowing inside a tube bent the sensor toward the direction of fluid flow (Fig. 4). The bulk flow of the fluid is quantized by the bending moment exerted on the bend sensor that is caused by the drag associated with the flowing fluid.5 The flow tube for sensor testing was assembled using two segments of opaque PVC (0.73 -m length) and transparent acrylic (0.29 m), with the same internal diameter of 36 mm. A ball valve, for the regulation of the flow rates during testing, was fitted to one end of the PVC pipe, which was connected by a flexible hose to a submerged pump (DC Runner 2.1, Aqua Medic) in a seawater basin. The ultrasonic flow meter (Siemens Sitrans, FUP 1010) was installed on the PVC section of the flow tube for measuring the water flow rates to the test sensor that was vertically fixed and adhesive-sealed through a slit on the acrylic tube. With the acrylic tube being transparent, it provided clear visualization of the sensor bending at various flow rates during testing. Hence, the flow experiments were conducted with a velocity up to 3 m/s to minimize effects of turbulent flows. Figure 5a and b show responses of the bending sensor, when the water flow induces tension and compression, respectively, in the LIG electrodes. The sensor response is linear within the speed range of 0.5–3 m/s. The sensitivities obtained for the flow sensor are ~100 Ω/(m/s) and ~110 Ω/(m/s), for the cases of LIG tension and compression, respectively.

Fig. 4
figure 4

Schematic of the flow test setup. The inset shows the bending the LIG sensor toward the direction of fluid flow

Fig. 5
figure 5

The response of the bending sensor to different flow velocities, when the LIG electrode is a extended and b compressed

Double-sided LIG sensor

The sensor concept in combination with the simple fabrication process, allow fabricating a double-sided LIG sensor, where the LIG electrodes are patterned on both sides of the PI film (Fig. 6a, b). By utilizing a difference measurement, where the output signals of the sensor under compression and tension are subtracted, several advantages arise. First, an equal directional response is obtained for both bending directions, since compressive and tensile responses are added up. Second, the output voltage is zero under zero-load condition, allowing for higher signal amplification. Third, a rejection of common input signals is achieved. An example for the latter is the effect of temperature, which is removed by using the double-sided LIG sensor. As previously reported, the resistance of LIG electrodes decreases by 4% over a temperature range of 20–60 °C.63 By measuring the resistance change of both sensor electrodes of the LIG sensor (Fig. 7a) and subtracting them from each other (Fig. 7b), the electrode deflection and applied force can be determined, with the same sensitivity in both bending directions. Since both LIG electrodes are affected by the same temperature (Fig. 8a), signal subtraction results in a complete compensation of the temperature effect (Fig. 8b). This is possible, due to the close proximity of the printed electrodes (~50 μm) and high thermal conductivity of PI (0.46 W m−1 K−1).

Fig. 6
figure 6

Schematics of a a double-sided LIG bending sensor and b its cross-section with the stress, due to bending

Fig. 7
figure 7

a The responses of a double-sided LIG sensor to bending with the LIG under tension and compression states. b The results of difference measurements

Fig. 8
figure 8

a The resistance of the LIG temperature sensor as a function of temperature. Each data point represents the average of three measured values; each error bar connects the maximum and the minimum values. b The result of subtracting the average output signals of electrodes from each other

Marine animals monitoring

The LIG bending sensors proves a powerful tool, when coupled with aquatic tags, such as Aquamote64 and Daily diary,65 to allow reconstruction of fine-scale behavior. Animal monitoring experiments were carried out at the Oceanographic Foundation Research Center in Valencia on a Bottlenose dolphin (the genus Tursiops) and a Loggerhead sea turtle (Caretta caretta). To this end, an LIG sensor of 17.2 kΩ resistance, shown in Fig. 9 (width: 7 mm, length: 15 mm, number of turns: 11), was integrated with a commercial tag (ICM-20948, TDK InvenSense), which was attached to the dolphin’s spine noninvasively by a vacuum sucker (Fig. 10a), and the turtle’s carapace by a waterproof velcro (VLC02, Velcro® Brand Marine Grade Hook and Loop) and pure epoxy compound (Subcoat S, Veneziani Yachting) (Fig. 11a). The resistance of the LIG tag was recorded during a dolphin’s training session and translated to swimming speeds via a calibration obtained from Fig. 6. Different maneuvers, such as shallow-, medium-, and deep diving and swimming (Fig. 10b) were carried out by the dolphin in 3 min, and were clearly reflected in the sensor response, with a maximum speed of ~2.7 m/s reached during deep diving and an average speed of ~0.8 m/s, ~1.3 m/s, ~2 m/s, and ~0.4 m/s for shallow-, medium-, and deep diving and swimming, respectively. The overall average and median speeds of the Bottlenose dolphin were ~0.32 m/s and ~0.3 m/s, respectively. The speed recorded when the dolphin was swimming at the surface of the water is likely inaccurate, due to submerging of the sensor. A different sensor position could help remedying this problem.

Fig. 9
figure 9

a LIG electrodes (black) patterned on a flexible polyimide sheet (orange). b Schematic of a cross-section of piezoresistive cantilever beam

Fig. 10
figure 10

a LIG bending sensor integrated with ultra-low power Aquamote tag (scale bar: 2 cm) and attached to a dolphin’s spine. b The resistance of the LIG sensor and corresponding swim speed of the dolphin as a function of time for a duration of 3 min

Fig. 11
figure 11

a LIG bending sensor integrated with commercial tag (scale bar: 1 cm) and attached to the sea turtle. b The recorded speed of sea turtle as a function of time for a duration of 4 h

The measurements of the sea turtle’s speed required a more sensitive speed sensor than the one used for the dolphin, due to the slower motion of the turtle. As described above, the sensitivity can be easily tailored by increasing the cantilever length or area. Therefore, the sensor design was modified to increase its area by the addition of a 2 × 2 cm2 patch, as shown in Fig. S3. The sea turtle reached the maximum speed of ~1.82 m/s, when swimming to the surface to breath, which happened seven times during the recorded ~4 h (Fig. 11b). The average and median speeds of the turtle were ~0.51 m/s and ~0.53 m/s, respectively. The turtle was constantly in motion with the lowest speed reaching ~0.1 m/s.

Flow velocity monitoring

Another LIG sensor (width: 7 mm length: 15 mm, number of turns: 3) was combined with a Daily Diary tag (TDR10-DD, Wildlife computers), which had a size of 20 × 20 mm2 (Fig. 12a), to measure the flow velocity of the underwater currents at the Al Fahal coral reef in the Cental Red Sea (geographic coordinates: 22.25285 °N, 38.96123 °E, average salinity: ~35%, average temperature ~33 °C) (Fig. 12b; Supplementary Movie 1). The result of a flow measurement over ~1 h (Fig. 12c) reveals that surface current flow had average and median speeds of ~0.47 m/s and ~0.48 m/s, respectively, with an occasional increase to a maximum speed of ~0.92 m/s. The minimum speed was ~0.21 m/s.

Fig. 12
figure 12

a Tag deployment in Al Fahal Reef of Red sea to measure flow velocity. Inset shows the LIG bending sensor integrated with a Daily Diary tag (scale bar: 1 cm). b Recorded resistance as a function of time for a duration of 1 h

Wearable device

The schematic illustration of LIG bending sensors attached to various body locations for associated detection of joint-bending-related motions, such as fingers, elbows, knees, ankle, and neck, is shown in Fig. 13. LIG sensors of various geometry were directly and noninvasively mounted using 0.1 g of biocompatible petroleum jelly (Vaseline® Products). The responses of the index finger bending forward and backward consecutively with various speeds (~0.1 bends/min and ~0.25 bends/min) are shown Fig. 13a. Figure 13b displays knee-related motions, which discriminate walking, jogging, and squatting according to their distinctly differentiated waveforms. The combinations of two or more LIG sensors would allow the measurement of multiple DOFs, such as torso, shoulder, and ankle. A hypnagogic jerk (sleep start or hypnic jerk) is a brief contraction of the body that occurs involuntarily, when a person is beginning to fall asleep, which often causes the person to jump and awake suddenly. The associated movement of the head results in neck bending, which can be monitored for assessing drivers vigilance.66,67 This head movement was measured by means of an LIG bending sensor attached to the neck, as seen in Fig. 13c.

Fig. 13
figure 13

a Schematic of wearable LIG bending sensors attached to different positions of a human body to monitor joint-bending-related motions. b Monitoring the response of finger bending c Knee-related motion monitoring: walking, jogging, and squatting. d Microsleep detection by monitoring head nodding and waking up

The outstanding material properties of LIG opened new perspectives for a versatile, durable, printed bending sensor capable of detecting flow, deflection or force across a range of conditions, and on a range of subjects. The flexibility in geometry and a simple fabrication process allow simple tuning of the bending sensor to achieve different sensitivities or dynamic ranges. Using tensile stress/strain measurements, a Young modulus of 2.1 GPa and yield strength of 83 MPa were found for the sensor with LIG printed on 125 -µm-thick Kapton tapes. The gauge factor of LIG is 1.16 with a piezoresistive coefficient of ~0.84. The sensor has a very large range with maximum strains reaching 14%. Bending tests in the form of cantilever deflection and point load showed a linear response to compressive and tensile bending of the LIG. A double-sided electrode concept was developed by printing on both sides of the Kapton. In combination with a difference measurement, an increased and homogeneous bidirectional response was obtained with full temperature compensation. The sensor can also withstand harsh environment conditions over an extended period of time.

The developed LIG sensors were applied in several applications to demonstrate their versatility, such as marine animals’ speed monitoring, current flow velocity measurements in a coral reef, as well as human joint bending and motion tracking. Thereby, the LIG sensors feature lightweight and minimal intrusiveness, accommodating the requirements to monitor animals with very different velocities and behaviors. Attached to the human body, the wearable sensors operated at large bending ranges, showing a great potential for personal healthcare monitoring, smart prosthetics, and human–machine interactions.

Methods

Fabrication of LIG sensor

Conductive porous graphene electrodes were directly patterned on commercial PI films of 125 μm in thickness (Kapton # IM301449, DuPont, Delaware, USA) using a CO2 infrared laser (wavelength 10.6 μm, laser spot diameter ~150 μm, Universal Laser Systems® PLS6.75) in ambient condition and used as piezoresistors. The laser beam parameters of 3.6 W power, 3 cm/s speed, 1000 pulses per inch, and 3 -mm laser-to-surface distance were tuned to obtain good adhesion of the carbon network to the substrate and achieve the porous morphology. The printed electrode pattern was structured in a meander shape (Fig. 1a) to provide a large change in resistance, while keeping the minimum electrode width ( ~150 μm, corresponding to the laser spot diameter). To provide a stable wire connection to the sensor, 80 nm of gold were sputtered on top of both contact pads, as shown in Fig. 1a. The electrical wires were connected using conductive epoxy (CW2400, CircuitWorks. Inc), which features strong mechanical bonds, excellent electrical conductivity, and quick room temperature curing. Finally, in case of operation in conductive media like seawater, a polydimethylsiloxane (PDMS) coating was applied to avoid interference with the measurement, due to shunt currents. PDMS (Dow Corning Corp., Slygard® 184) with a ratio of 10 (base):1 (curing agent) was spin coated on top (2500 revolutions per min for 90 s) of the device, and the sample was placed in a vacuum desiccator for 20 min to eliminate air bubbles. Then, this passivation layer was cured in the oven at 80 °C for 1 h. The thickness of the PDMS was 10 µm.

Working principle

The bending sensor utilizes LIG on a flexible PI film to transduce a signal via cantilever deflection, i.e., it is supported at one end with the other end free (Fig. 1b). An external force, F, applied to the tip of the cantilever induces a uniaxial stress,68,69

$$\sigma = \frac{{F\left( {L - d} \right)c}}{{I_A}},$$
(2)

where, L is the cantilever length, c is the distance to the neutral axis, d is the distance from the support, and IA is the area moment of inertia. Therefore, the longitudinal stress varies linearly through the cantilever thickness and along its length. The maximum stress, σmax, occurs at the surface of the cantilever at the anchor point, as shown in Fig. 1b. The interaction of sensor with an external force, such as water flow, along the y-axis induces a cantilever bending and fractional resistance change that can be approximated by68,69,70,71

$$\frac{{\Delta R}}{R} = \pi _{\mathrm{l}}\sigma _{{\mathrm{max}}} = \frac{{6\pi _{\mathrm{l}}(L - L_{{\mathrm{pr}}}/2)}}{{wt^2}}F,$$
(3)

where πl is the piezoresistive coefficient, Lpr is the length of the piezoresistor, t and w are the thickness and width of the cantilever, respectively. Hence, the sensitivity of the sensor is tuned by the length and cross-sectional area of the sensor substrate and the length of the piezoresistor.

All studies, and the current study, were performed under approvals Oce-4-18 and Oce-12-18- by the Animal Care and Use Committee at the Oceanogràfic. In addition, all studies at the Oceanogràfic were supervised by veterinary and husbandry at staff of the Oceanografic. All procedures involving human were approved by the KAUST Institutional Biosafety and Bioethics Committee (IBEC). The volunteers provided signed consent to participate in the study.