Abstract
Achieving the ultimate precisions for multiple parameters simultaneously is an outstanding challenge in quantum physics, because the optimal measurements for incompatible parameters cannot be performed jointly due to the Heisenberg uncertainty principle. In this work, a criterion proposed for multiparameter estimation provides a possible way to beat this curse. According to this criterion, it is possible to mitigate the influence of incompatibility meanwhile improve the ultimate precisions by increasing the variances of the parameter generators simultaneously. For demonstration, a scheme involving high-order Hermite-Gaussian states as probes is proposed for estimating the spatial displacement and angular tilt of light at the same time, and precisions up to 1.45 nm and 4.08 nrad are achieved in experiment simultaneously. Consequently, our findings provide a deeper insight into the role of Heisenberg uncertainty principle in multiparameter estimation, and contribute in several ways to the applications of quantum metrology.
Similar content being viewed by others
Introduction
Quantum parameter estimation plays a vital role in a wide range of physics and engineering, including interferometry1,2,3,4, superresolution5,6,7,8, optical sensing9,10,11 and so on. Generally, the ultimate precision of estimating unknown parameter is characterized by the quantum Cramér-Rao (QCR) bound12,13,14, which can be explicitly calculated by the quantum Fisher information matrix (QFIM)15,16. For single-parameter estimation, the QCR bound is always attainable by assigning an optimal measurement17,18,19. In multiparameter estimation, there is a quantum limit (QL) point that the estimating precisions for all parameters achieve their QCR bounds simultaneously. This QL point can be saturated only if the optimal measurements for all parameters are compatible, such as the estimation of multiple phases20,21 and parameters in SU(2) operators with ancillary qubits22,23. Unfortunately, the optimal measurements for incompatible parameters can not be jointly performed due to the Heisenberg uncertainty principle (HUP), thus the QL point is unachievable24,25,26. To determine the attainable precisions of incompatible parameters, a trade-off relation between the estimation inaccuracies for different parameters27 was recently revealed by incorporating the HUP and Ozawa’s uncertainty relation28,29.
Although the QL point of incompatible parameters is unachievable, we find that their trade-off precision bound can be dramatically improved by devising an appropriate measurement probe. By revealing the connection between variances of estimation errors and generators30 corresponding to different parameters, a criterion is proposed to guide the design of probe. It significantly indicates that, increasing the variances of generators simultaneously may not only improves the quantum limits, but also mitigates the incompatibility of corresponding parameters, and then the estimating precisions can approach to the QL point asymptotically.
In this work, we study a scheme that measuring the parameters of momentum and position simultaneously in a quantum system. By employing the Hermite-Gaussian (HG) state as the measurement probe, of which the momentum and position variances increase simultaneously along with the mode number, the QL point of this pair of incompatible parameters can be approached asymptotically according to our criterion. To suppress the technical noise31,32,33, we also introduce the post-selected weak measurement technique in our system. For demonstration, our scheme is performed in an optical experiment by employing HG beams, where the incompatible parameters are produced by the weak transverse displacement and angular tilt of light. When the number of HG mode increases, the estimation errors of different parameters decrease and approach to their incompatible quantum limits simultaneously, which agrees well with our theoretical prediction. Especially, precisions up to 1.45 nm and 4.08 nrad for estimating spatial displacement and angular tilt of light are achieved at the same time in our experiment. As the theoretical and experimental results all indicate that our method not only mitigates the incompatibility to approach the simultaneous quantum limits, but also improves the quantum limits to achieve the smaller estimation errors, our findings will be of interest to many application scenarios in quantum metrology, e.g., polarization microscopy34, qubit tomography35, estimation of a multidimensional field36, metrology of correlated phase and loss37, and joint measurement of phase and phase diffusion38.
Results and discussion
Quantum criterion of multiparameter estimation
Let us start with the quantum multiparameter estimation process illustrated in Fig. 1. An evolution operator \(\hat{U}({{{{{\boldsymbol{g}}}}}})\) with n unknown parameters \({{{{{\boldsymbol{g}}}}}}=({g}_{1},{g}_{2},\ldots,{g}_{n})\in {{\mathbb{R}}}^{n}\) transfers a probe state \(|\psi \rangle\) to a parameterized state of \(|{\psi }_{{{{{\boldsymbol{g}}}}}}\rangle\). Afterwards, the values of g can be estimated via performing measurements on \(|{\psi }_{{{{{\boldsymbol{g}}}}}}\rangle\). By devising the optimal measurements for all parameters, the QCR bound gives the quantum limit on the precision of every parameter via the QFIM.
Generally, the quantum Fisher information (QFI) of parameter gi can be derived as \({{{{{{{{\mathcal{Q}}}}}}}}}_{ii}=4\langle {{\Delta }}{\hat{H}}_{i}^{2}\rangle\) (\({{{{{{{{\mathcal{Q}}}}}}}}}_{ii}\) is the i-th diagonal element of the corresponding QFIM \({{{{{{{\mathcal{Q}}}}}}}}\)), where \(\langle {{\Delta }}{\hat{H}}_{i}^{2}\rangle \equiv \left\langle \psi \right|{\hat{H}}_{i}^{2}\left|\psi \right\rangle -\left\langle \psi \right|{\hat{H}}_{i}{\left|\psi \right\rangle }^{2}\) is the variance of \({\hat{H}}_{i}\), with \({\hat{H}}_{i}={{{{{{{\rm{i}}}}}}}}[\frac{\partial }{\partial {g}_{i}}{\hat{U}}^{{{{\dagger}}} }({{{{{{{\boldsymbol{g}}}}}}}})]\hat{U}({{{{{{{\boldsymbol{g}}}}}}}})\) being the generator of gi, which leads to the quantum limit of parameter gi given by30:
where ν is the measured samples number. This limit can be saturated via an optimal measurement connected to generator \({\hat{H}}_{i}\)17,39 in the single-parameter estimation. Moreover, this limit also implies that the precision of a single parameter can be improved by maximizing the variance of \({\hat{H}}_{i}\), which requires to optimize the probe state.
However, achieving the quantum limits for all parameters simultaneously requires their corresponding optimal measurements being compatible, which is granted by checking the weak commutative condition17:
where \([{\hat{H}}_{i},{\hat{H}}_{j}]\equiv {\hat{H}}_{i}{\hat{H}}_{j}-{\hat{H}}_{j}{\hat{H}}_{i}\), 〈⋅〉 denotes for \(\left\langle \psi \right|\cdot \left|\psi \right\rangle\). For two incompatible parameters gi and gj who do not satisfy the weak commutative condition, their optimal measurements can not be performed simultaneously, so their quantum limits are incompatible to be achieved. To deeply investigate the incompatibility from the physical insight, we relate the generators \({\hat{H}}_{i}\) and \({\hat{H}}_{j}\) of the incompatible parameters by Heisenberg’s uncertainty relation:
We will show that in follows, the incompatibility between measurements can be dramatically mitigated by using appropriate probe state, so that the QL point can be approached asymptotically. To achieve this goal, the probe state should be chosen maximizing the variances of \({\hat{H}}_{i}\) and \({\hat{H}}_{j}\). According to Eq. (1), this method can also improve the quantum limits to achieve smaller estimation errors regarding to parameters gi and gj.
To illustrate our result, we first define the quantum multiparameter estimation criterion (QMEC) as follow:
According to Eq. (3), we have Sij ≥ 1. The value of Sij corresponds to the uncertainties of \({\hat{H}}_{i}\) and \({\hat{H}}_{j}\). They are minimized simultaneously when Sij = 1 and become larger when Sij increases.
With the QMEC in hand, the achievable precision limit in multiparameter estimating is given by a trade-off relation27 (see the Supplementary Note 1 for derivation):
where \(\delta {\tilde{g}}_{i}=\sqrt{{{{{{{{{\mathcal{Q}}}}}}}}}_{ii}}\delta {g}_{i}=2\sqrt{\langle {{\Delta }}{\hat{H}}_{i}^{2}\rangle }\delta {g}_{i}\) and \(\delta {\tilde{g}}_{j}=\sqrt{{{{{{{{{\mathcal{Q}}}}}}}}}_{jj}}\delta {g}_{j}=2\sqrt{\langle {{\Delta }}{\hat{H}}_{j}^{2}\rangle }\delta {g}_{j}\) are the normalized estimation errors for the normalized parameters \({\tilde{g}}_{i}=\sqrt{{{{{{{{{\mathcal{Q}}}}}}}}}_{ii}}{g}_{i}\) and \({\tilde{g}}_{j}=\sqrt{{{{{{{{{\mathcal{Q}}}}}}}}}_{jj}}{g}_{j}\), which are dimensionless and reflect the discrepancies between the practical attainable precisions and the corresponding quantum limits. This trade-off relation not only reveals the achievable precision limit of multiparameter estimation, but also indicates a possible way to achieve simultaneous ultimate precisions via the criterion \({{{{{{{{\mathcal{S}}}}}}}}}_{ij}\).
Based on Eq. (4) and Eq. (5), the trade-off precision bounds are compared with the single parameter limits in Fig. 2. Here, the quantum limit (QL) point represents the simultaneous ultimate precisions for the parameters gi and gj. It clearly shows that the trade-off precision bound approaches the QL point when Sij increases, and the worst trade-off bound appears when Sij = 1. In other words, the larger the uncertainties of \({\hat{H}}_{i}\) and \({\hat{H}}_{j}\) are, the easier to achieve the ultimate precisions simultaneously.
The QMEC together with Eq. (5) provide us a guidance for optimizing the probe state for multiparameter estimation. As an example, we consider the simultaneous estimations on parameters with generators of momentum operator \(\hat{P}\) and position operator \(\hat{X}\). In this case, the unitary parameterization is \(\hat{U}({{{{{{{\boldsymbol{g}}}}}}}})=\exp (-{{{{{{{\rm{i}}}}}}}}{g}_{1}\hat{P}-{{{{{{{\rm{i}}}}}}}}{g}_{2}\hat{X})\), where g1 and g2 representing position displacement and momentum kick are the parameters of interest, and the corresponding QMEC can be easily calculated as \({{{{{{{{\mathcal{S}}}}}}}}}_{12}={{{{{{{{\mathcal{S}}}}}}}}}_{21}=4\langle {{\Delta }}{\hat{P}}^{2}\rangle \langle {{\Delta }}{\hat{X}}^{2}\rangle\). (Without loss of generality, we adopt units making ℏ = 1 in this article.) Let us take Gaussian state, which is usually used as probe [42,43] for example. Gaussian state satisfying \(\langle {{\Delta }}{\hat{P}}^{2}\rangle \langle {{\Delta }}{\hat{X}}^{2}\rangle=1/4\) yields \({{{{{{{{\mathcal{S}}}}}}}}}_{12}=1\), which means it gets the worst trade-off precision bound. In this sense, the high-order Hermite-Gaussian (HG) state40 with larger uncertainties on \(\hat{P}\) and \(\hat{X}\) could be a better choice for probe.
Simultaneous measurement of incompatible parameters
To practical verify our theory, we investigate a post-selected weak measurement scheme where a pair of incompatible parameters is loaded simultaneously during the weak interaction procedure. As is illustrated in Fig. 3, a two-level system and a pointer with continuous degree of freedom are prepared in states of \(\left|i\right\rangle\) and \(\left|{\psi }_{i}\right\rangle\) respectively. During the weak interaction procedure, the position displacement parameter g1 and momentum kick parameter g2 are coupled simultaneously to pointer with a impulse Hamiltonian \({\hat{H}}_{{{{{{{{\rm{I}}}}}}}}}=\left({g}_{1}\hat{P}\otimes \hat{A}+{g}_{2}\hat{X}\otimes \hat{A}\right)\delta (t-{t}_{0})\), where \(\hat{A}\) is an Hermitian operator on the two-level system. Thus, the theoretical unitary parameterization in weak measurement scheme is \(\hat{U}({{{{{{{\boldsymbol{g}}}}}}}})={\hat{U}}_{{{{{{{{\rm{w}}}}}}}}}=\exp (-{{{{{{{\rm{i}}}}}}}}\int{\hat{H}}_{I}{{{{{{{\rm{d}}}}}}}}t)\). By adopting the weak interaction assumption g1σp << 1 and g2σx << 1, the unitary parameterization can be approximately calculated as
To individually read out the measurement parameters from the pointer, we post-select the system by state \(\left|f\right\rangle\), and turn the final state in whole to be a product state \(|{\psi }_{f}\rangle|f \rangle\), where
is the final state of pointer, and \({A}_{w}=\left\langle f\right|\hat{A}\left|i\right\rangle /\langle f|i\rangle\) is weak value. Then the corresponding QFIM can be obtained as:
where 〈⋅〉i denotes for \(\left\langle {\psi }_{i}\right|\cdot \left|{\psi }_{i}\right\rangle\). Thus, the QMEC in our measurement scheme for incompatible parameters g1 and g2 can be calculated as
which has the same expression of the post-selection-free scheme, and is only dependent on the momentum and position uncertainty of initial pointer state. (See Supplementary Note 1 for calculation details.)
In the conventional weak measurement scheme, the pointer is usually chosen to have Gaussian distribution, which leads to the worst QMEC \({{{{{{{{\mathcal{S}}}}}}}}}_{12}=1\). According to the trade-off relation of parameters’ precisions in Eq. (5), the corresponding trade-off bound of Gaussian pointer is given by:
where
are respectively the normalized estimation errors of parameters g1 and g2. For simplicity, we can also define the normalized parameter vector
Here, we illustrated the the normalized estimation errors \(\delta {\tilde{g}}_{1}\) and \(\delta {\tilde{g}}_{2}\) with Gaussian pointer in Fig. 4a, where the cross point (red triangle in figure) of the QCR bounds (gray dashed lines in figure) is the QL point \({{{{{{{{\mathcal{P}}}}}}}}}_{{{{{{{{\rm{Q}}}}}}}}}=\sqrt{\nu }(\delta {\tilde{g}}_{1{{{{{{{\rm{Q}}}}}}}}}^{\min },\delta {\tilde{g}}_{2{{{{{{{\rm{Q}}}}}}}}}^{\min })=(1,1)\). However, according to the trade-off relation in Eq. (5), the achievable boundary of simultaneous estimation errors is dependent on the probe’s uncertainty. For Gaussian pointer, the trade-off bound given by Eq. (10) is illustrated by the blue solid curve in Fig. 4a, where improving the estimating precision of one parameter toward the quantum limit will make the estimation error of the other parameter turn to infinite. It means that the QL point can not be achieved for incompatible parameters via Gaussian pointer.
To improve the trade-off bound of the incompatible parameters, we employ the n-order Hermite-Gaussian (HG) state as our initial pointer, whose spatial wave function is:
where \({\sigma }_{0}^{2}\) is the variance of spatial distribution of fundamental Gaussian state. From the view of quantum mechanics, n-order HG state can be denoted by the n-order eigenket of harmonic oscillators \(\left|n\right\rangle\). Then the momentum and position uncertainty can be calculated as \({\langle {{\Delta }}{\hat{P}}^{2}\rangle }_{i}=(2n+1)/4{\sigma }_{0}^{2}\), \({\langle {{\Delta }}{\hat{X}}^{2}\rangle }_{i}=(2n+1){\sigma }_{0}^{2}\), which lead to the QMEC with n-order HG pointer being improved as:
Therefore, the corresponding trade-off bound of HG pointer can be calculated as:
where \(\delta {\tilde{g}}_{1}=\left|{A}_{w}\right|\sqrt{2n+1}\delta {g}_{1}/{\sigma }_{0}\) and \(\delta {\tilde{g}}_{2}=2\left|{A}_{w}\right|{\sigma }_{0}\sqrt{2n+1}\delta {g}_{2}\). According to Eq. (12), the corresponding normalized parameter vector can be calculated as
According to Eq. (15), the trade-off bound of n-order HG pointer is improved to a finite length curve with two endpoints:
Though the QL point \({{{{{{{{\mathcal{P}}}}}}}}}_{{{{{{{{\rm{Q}}}}}}}}}=(1,\,1)\) of the incompatible parameters is practically unachievable with any classical measurement methods. However, we find that the trade-off bound of HG pointer is gradually closing to the QL point as the increasing of mode number n, because
From this relation, we can conclude that: when n → ∞, the endpoints of trade-off bound \({{{{{{{{\mathcal{P}}}}}}}}}_{{{{{{{{\rm{L}}}}}}}}}^{(n)}\to {{{{{{{{\mathcal{P}}}}}}}}}_{{{{{{{{\rm{Q}}}}}}}}}\), \({{{{{{{{\mathcal{P}}}}}}}}}_{{{{{{{{\rm{R}}}}}}}}}^{(n)}\to {{{{{{{{\mathcal{P}}}}}}}}}_{{{{{{{{\rm{Q}}}}}}}}}\), which means that by employing high-order HG pointer, we can approach the quantum limits of the incompatible parameters simultaneously with some classical measurement methods in a practical system.
Here, we illustrated the trade-off bounds of HGn pointer and HGn−1 pointer (n > 1) in Fig. 4b, where the blue solid curve is the trade-off bound of HGn pointer and the purple solid curve is the trade-off bound of HGn−1 pointer. Moreover, the gray shadowed region between these two curve is allowed for HGn pointer but forbidden for HGn−1 pointer, which is named as HGn region.
The results illustrated in Fig. 4b show that the incompatible quantum limits for parameters g1 and g2 can be approached simultaneously by increasing the mode number of HG pointer. Moreover, it can be proved that this improvement depends on the uncertainty properties of the high-order HG state rather than its higher energy level. (See the Supplementary Note 2 for details.)
To implement the practical measurement of the incompatible parameters, we would like to investigate two widely used practical measurement strategies: direct imaging and non-orthogonal projection. Given a set of positive-operator-valued measure (POVM) \(\hat{{{\Pi }}}=\{{\hat{{{\Pi }}}}_{\lambda }\,\left|\right.\,{\hat{{{\Pi }}}}_{\lambda }\ge 0,{\sum }_{\lambda }{\hat{{{\Pi }}}}_{\lambda }=\hat{{\mathbb{I}}}\}\), the estimation covariance matrix of parameters g satisfies the classical Cramér-Rao (CCR) inequality: \({{{{{{{\rm{Cov}}}}}}}}({{{{{{{\boldsymbol{g}}}}}}}},\hat{{{\Pi }}})\ge \frac{1}{\nu }{{{{{{{{\mathcal{F}}}}}}}}}^{-1}\), where \({{{{{{{\mathcal{F}}}}}}}}\) is the classical Fisher information matrix (CFIM) with entry be calculated by41:
where \({\langle {\hat{{{\Pi }}}}_{\lambda }\rangle }_{{{{{\boldsymbol{g}}}}}}=\langle {\psi }_{{{{{\boldsymbol{g}}}}}}|{\hat{{{\Pi }}}}_{\lambda }|{\psi }_{{{{{\boldsymbol{g}}}}}}\rangle\) is the measurement probability of state \(|{\psi }_{{{{{\boldsymbol{g}}}}}}\rangle\) under operator \({\hat{{{\Pi }}}}_{\lambda }\). Substituting \(|{\psi }_{i}\rangle=|n\rangle\) into \(|{\psi }_{f} \rangle\), the final pointer state after the incompatible-parameters interaction can be calculated as:
where \(\left|{\psi }_{\hat{P}}\right\rangle\) and \(\left|{\psi }_{\hat{X}}\right\rangle\) are the generated states by operators \(\hat{P}\) and \(\hat{X}\):
For direct imaging method, the measurement operators can be denoted as \({\hat{{{\Pi }}}}^{{{{{{{{\rm{DI}}}}}}}}}=\left\{\left|x\right\rangle \left\langle x\right|\,\left|\right.\,x\in {\mathbb{R}}\right\}\). Substituting \({\hat{{{\Pi }}}}_{{{{{{{{\rm{DI}}}}}}}}}\) into Eq. (19), the CFIM of direct imaging method can be obtained as:
Combining with the CCR inequalities, the normalized estimation errors of the incompatible parameters can be proved satisfying the inequality:
We illustrate this joint precision-limit bound in Fig. 4c with green solid curve, where the separate ultimate precisions of parameters are \(\delta {\tilde{g}}_{1{{{{{{{\rm{R}}}}}}}}}^{\min }\) and \(\delta {\tilde{g}}_{2{{{{{{{\rm{L}}}}}}}}}^{\min }\). Though \(\delta {\tilde{g}}_{1{{{{{{{\rm{R}}}}}}}}}^{\min }\) and \(\delta {\tilde{g}}_{2{{{{{{{\rm{L}}}}}}}}}^{\min }\) separately approach the quantum limits \(\delta {\tilde{g}}_{1{{{{{{{\rm{Q}}}}}}}}}^{\min }\) and \(\delta {\tilde{g}}_{2{{{{{{{\rm{Q}}}}}}}}}^{\min }\) as the increasing of mode number n, these two parameters can not approach their ultimate precision limits simultaneously based on the inequality in Eq. (23), which means that the direct imaging method is incapable to approach the QL point of incompatible parameters.
Drawing on the method of unambiguous quantum state discrimination42,43, we devise a set of non-orthogonal projection operators \({\hat{{{\Pi }}}}_{\not\perp }=\{{\hat{{{\Pi }}}}_{1}=|{\psi }_{\hat{X}}^{\perp }\rangle \langle {\psi }_{\hat{X}}^{\perp }|,\,{\hat{{{\Pi }}}}_{2}=|{\psi }_{\hat{P}}^{\perp }\rangle \langle {\psi }_{\hat{P}}^{\perp }|,\,\hat{{\mathbb{I}}}-{\hat{{{\Pi }}}}_{1}-{\hat{{{\Pi }}}}_{2}\}\), where the states:
which are orthogonal to the parameters generated states \(\left|{\psi }_{\hat{P}}\right\rangle\) and \(\left|{\psi }_{\hat{X}}\right\rangle\). Therefore, it is easy to determine that the parameters g1 and g2 can be separately detected by the projection measurements \({\hat{{{\Pi }}}}_{1}\) and \({\hat{{{\Pi }}}}_{2}\).
Substituting the POVM \({\hat{{{\Pi }}}}_{\not\perp }\) into Eq. (24), the CFIM of non-orthogonal projection method can be obtained as:
which leads to the precision limits
Combining with Eq. (18), it reveals that the QL point of the incompatible parameters can be approached asymptotically by employing non-orthogonal projection measurement, and the corresponding practical precision limit in Eq. (26) is a point at:
Obviously, we can calculate that: when n → ∞, the precision limit point \({{{{{{{{\mathcal{P}}}}}}}}}_{\not\perp }^{(n)}\to {{{{{{{{\mathcal{P}}}}}}}}}_{{{{{{{{\rm{Q}}}}}}}}}\), which means that non-orthogonal projection measurement can approach the quantum limits of the incompatible parameters simultaneously.
Experimental set-up and results
To experimentally verify that using HG pointer can approach the quantum limits of incompatible parameters simultaneously, we employ Hermite-Gaussian beam in an optical experiment, whose transverse spatial state can be expressed as \(\left|{u}_{n}(z)\right\rangle=\hat{U}(z)\left|n\right\rangle\), where \(\hat{U}(z)=\exp \left({{{{{{{\rm{i}}}}}}}}\frac{1}{2k}{\hat{P}}^{2}z\right)\) is the z-dependent propagation operator. Here k = 2π/λ is the wave number of light beam and z is the propagation distance begin from the beam waist. Therefore, the generators of the incompatible parameters g1 and g2 should evolve as \(\hat{P}(z)=\hat{U}(z)\hat{P}{\hat{U}}^{{{{\dagger}}} }(z)\) and \(\hat{X}(z)=\hat{U}(z)\hat{X}{\hat{U}}^{{{{\dagger}}} }(z)\).
In this experiment, we generate the n-order HG beam via a spatial light modulator (SLM) and a spatial filter system44, as is shown in Fig. 5. The light beam from the laser working at 780nm is expanded for generating HG beams. Here, we choose the beam’s polarization kets \(\left|H\right\rangle\) and \(\left|V\right\rangle\) as the basis of measured two-level system. The pre-selection state \(\left|i\right\rangle=\frac{1}{\sqrt{2}}\left(\left|H\right\rangle+\left|V\right\rangle \right)\) is implemented by a Glan-Taylor polarizer (GTP) and a half wave plate (HWP). The pre-selected beam is injected to a polarized Mach-Zehnder interferometer (MZI), and a mirror driven by two piezoelectric transducer (PZT) chips is used to generate the tiny transverse spatial displacement d and tiny angular tilt φ (which leads to a tiny transverse momentum kick of kφ) simultaneously for the \(\left|H\right\rangle\) component of light beam. Thus, the unitary evolution of this weak interaction procedure can be denoted as:
where \(\hat{A}=\frac{1}{2}\left(\hat{{\mathbb{I}}}+{\hat{\sigma }}_{z}\right)\), and \({\hat{\sigma }}_{z}=\left|H\right\rangle \left\langle H\right|-\left|V\right\rangle \left\langle V\right|\) is the Pauli operator.
After the weak interaction procedure in the polarized MZI, the light beam is post-selected by state \(\left|f\right\rangle=\cos \left(\frac{\pi }{4}-\frac{\varepsilon }{2}\right)\left|H\right\rangle -\sin \left(\frac{\pi }{4}-\frac{\varepsilon }{2}\right)\left|V\right\rangle\), where ε << 1 (in our experiment, the post-selection angle is set as ε = 5∘). Thus, the weak value can be calculated as
After the post-selection, another SLM is employed to implement the non-orthogonal projection measurement with a Fourier transfer lens and a spatial filtering from a single mode fiber (SMF) coupling detected photons to an avalanche photodiode (APD).
The optical length from the waist of HG beam to the signal mirror is denoted as z1, the length from the signal mirror to the second SLM is denoted as z2, and z1 + z2 = z0. Thus, the unitary parameterization with incompatible parameters g1 and g2 is \(\hat{U}({{{{{{{\boldsymbol{g}}}}}}}})=\hat{U}({z}_{2}){\hat{U}}_{{{{{{{{\rm{w}}}}}}}}}^{\exp }{\hat{U}}^{{{{\dagger}}} }({z}_{2})\) in this experiment (see the Methods part), where g1 and g2 can be separately expressed as
and the final beam state is then derived as (see the Methods part):
where \(\left|{u}_{\hat{P}}\right\rangle=\hat{U}({z}_{0})\left|{\psi }_{\hat{P}}\right\rangle\) and \(\left|{u}_{\hat{X}}\right\rangle=\hat{U}({z}_{0})\left|{\psi }_{\hat{X}}\right\rangle\) are the generated states by operators \(\hat{P}(z)\) and \(\hat{X}(z)\), \({\tilde{g}}_{1}={A}_{w}\sqrt{2n+1}{g}_{1}/{\sigma }_{0}\) and \({\tilde{g}}_{2}=2{A}_{w}\sqrt{2n+1}{\sigma }_{0}{g}_{2}\) are still the normalized parameters regarding the parameters g1 and g2. Thus the non-orthogonal projection operators for HG beams are \({\hat{{{\Pi }}}}_{1}=|{u}_{\hat{X}}^{\perp }\rangle \langle {u}_{\hat{X}}^{\perp }|\) and \({\hat{{{\Pi }}}}_{2}=|{u}_{\hat{P}}^{\perp }\rangle \langle {u}_{\hat{P}}^{\perp }|\).
By displaying the non-orthogonal projection \({\hat{{{\Pi }}}}_{1}\) on the SLM, the parameter g1 can be individually detected with projection probability
Then displaying the non-orthogonal projection \({\hat{{{\Pi }}}}_{2}\) on the SLM, the parameter g2 can be also individually detected with projection probability
In this experiment, we generate the position displacement and angular tilt signals simultaneously for light beam via a PZT driven mirror, where two asynchronous cosine driving signals with frequency f = 2 kHz and relative phase θ = 4∘ are exerted on the two PZT chips separately. Besides the 2 kHz driving signals, the initial displacement and tilt bias errors of the mirror can not be negligible in practice, which leads to the initial biases \({g}_{1}^{{{\Delta }}}\) and \({g}_{2}^{{{\Delta }}}\) for the parameters g1 and g2. Thus, the total signals of the incompatible parameters is denoted as \({g}_{1}^{{{{{{{{\rm{tot}}}}}}}}}={g}_{1}^{{{\Delta }}}+{g}_{1}\cos (2\pi ft)\) and \({g}_{2}^{{{{{{{{\rm{tot}}}}}}}}}={g}_{2}^{{{\Delta }}}+{g}_{2}\cos (2\pi ft)\) separately. It is easy to determine that \({g}_{1}\,\ll \, {g}_{1}^{{{\Delta }}} \, \ll \, 1\) and \({g}_{1} \, \ll \, {g}_{1}^{{{\Delta }}} \, \ll \, 1\) (see the Methods part).
In practice, before exerting the driving signals, we projected the final beam state on \(\left|{u}_{n}({z}_{0})\right\rangle\) to fix the effective sample number ν for different HG modes, which is obtained by the detected optical power I0 (experimental values of I0 and ν are given in the Method part). Then exert the driving signals on PZT chips and project the final beam on state \(|{u}_{\hat{X}}^{\perp }\rangle\) and \(|{u}_{\hat{P}}^{\perp }\rangle\) separately, whose corresponding detected optical powers are denoted as I1 and I2. Finally, the detected power signals were inputted into the spectrum analyzer, where we can independently demodulate the parameters g1 and g2 from the corresponding peak powers at f = 2 kHz:
Here we only concern with the shot noise in experiment, then the theoretical detected peak signal-to-noise ratios (SNR) with two non-orthogonal projections can be obtained as:
When SNR1 = 1, the minimum detectable parameter g1 is:
Similarly, when SNR2 = 1, the minimum detectable parameter g2 is:
Experimentally, the spatial displacement d and angular tilt φ of light beam can be estimated from the detected parameters g1 and g2 as \(d={g}_{1}-\frac{{z}_{1}}{k}{g}_{2}\) and φ = g2/k, which leads to the corresponding estimating errors be calculated as
Thus, the theoretical minimum detectable spatial displacement and angular tilt of light beam in our experiment can be obtained as:
where \(b=2k{\sigma }_{0}^{2}\) is the Rayleigh range.
In our experimental scheme, parameters g1 and g2 are able to directly detected by applying non-orthogonal projection measurement. Thus we illustrate the experimental precisions of parameters g1 and g2 in Fig. 6. The experimental results of minimum detectable parameters g1 and g2 are plotted without normalized, therefore the QL point of each HG mode is difference, and the HG regions turn into the ’L’-type. As is shown in Fig. 6a, our experimental precision points of different HG modes are exactly in the corresponding HG regions. In Fig. 6b to Fig. 6f, we illustrate the experimental results of HG1 mode to HG5 mode separately. In these sub-figures, we also plot the theoretical prediction of experimental precision for every HG mode, which is derived directly from Eq. (36) and Eq. (37) with the fixed experimental photons number ν = 1.05 × 107, post-selection angle ε = 5∘ and beam waist radius w0 = 2σ0 = 240 μm.
To directly exhibit our experimental results, we also list the driving voltages of PZT chips when SNR1 = 1 and SNR2 = 1, and the practical minimum detected values of parameters g1, g2, and the corresponding spatial displacement d and angular tilt φ with different HG modes in Table 1. As results, we finally achieve the 1.45 nm precision on the light beam’s spatial displacement and the 4.08 nrad precision on the light beam’s angular tilt when measuring them simultaneously with 5-order HG beam.
Geometrical properties of QMEC
In the quantum metrological process, the parameterization evolution \(\hat{U}({{{{{{{\boldsymbol{g}}}}}}}})\) projects the probe state \(\left|\psi \right\rangle\) in Hilbert space to the parameterized state \(|{\psi }_{{{{{\boldsymbol{g}}}}}}\rangle\) in parameter space. Theoretically, the matrix elements of \({{{{{{{\mathcal{Q}}}}}}}}\) are identical to the Fubini-Study metric45 for pure state, which is a second-order tensor in the projective Hilbert space (parameter space). Thus, the QFIM can be naturally extended to the quantum geometric tensor (QGT)46,47, whose entry is obtained by:
Obviously, QGT is a complex metric in the projective Hilbert space with properties:
where \({{{{{{{\mathcal{C}}}}}}}}\) is the Berry curvature (BC) defined on the parameter space. For quantum estimation theory, the non-diagonal elements of BC indicate the non-commutativity of different parameters, which means the larger the BC is, the harder to estimate two different parameters simultaneously. In Lu and Wang’s work27, they related the trade-off bound to the quantum geometric tensor. Then the QMEC can be calculated as (see the Supplementary Note 1 for derivation):
where the geometric properties on parameter space are involved. Especially, the QMEC indicates a normalized curvature on the parameter space:
where \({\tilde{{{{{{{{\mathcal{C}}}}}}}}}}_{ij}^{2}=1/{{{{{{{{\mathcal{S}}}}}}}}}_{ij}\). Traditionally, the Berry curvature \({{{{{{{{\mathcal{C}}}}}}}}}_{ij}\), i.e., the weak commutative condition is concerned alone in evaluating the incompatibility of different parameters on multiparameter estimation in Eq. (2). However, the geometrical properties of the QMEC in our work reveals that the Berry curvature alone is insufficient in evaluating the incompatibility, the metric property on the parameter space, i.e., the QFIM influences the attainability of simultaneous quantum limits on multiparameter estimation. Thus, the normalized curvature \({\tilde{{{{{{{{\mathcal{C}}}}}}}}}}_{ij}\) is more appropriate to describe the curvature property on the parameter space.
Comparison of trade-off bound and Holevo bound
The Holevo CR bound is another wide studied lower bound of estimating variances on multiparameter quantum estimation, which reveals the quantum limits on weighted mean errors and is proven attainable within collective measurements48,49. However, the Holevo CR bound is difficult to completely identify the trade-off curve regarding the attainable precision limits on estimating different parameters. In this part, we would like to give the Holevo CR bound on estimating two incompatible parameters of a parameterized pure state, and compare it with our trade-off bound.
Theoretically, the analytic expression of Holevo bound is difficult to be obtained for the generalized multiparameter estimation scenario, and numerical algorithms are widely employed for solving it50,51. In our work, we concern with the measurement scenario of two incompatible parameters for a pure state model, where the corresponding Holevo bound is given as:
which is first derived by Matsumoto at52. \(\delta {\tilde{g}}_{i}\) and \(\delta {\tilde{g}}_{j}\) are the normalized estimation errors for incompatible parameters gi and gj, \({\tilde{{{{{{{{\mathcal{C}}}}}}}}}}_{ij}\) is the normalized Berry curvature defined in Eq. (43). By comparing our trade-off bound of Eq. (5) with the Holevo bound in Fig. 7, we can see that the Holevo bound is exactly tangent to the trade-off bound at \(\delta {\tilde{g}}_{i}=\delta {\tilde{g}}_{j}\). From the results in Fig. 7, we can conclude that though the Holevo bound gives a tight bound of weighted mean errors for two incompatible parameters, it is less informative than the trade-off bound employed in our work.
Furthermore, we concern with the Holevo bound in our post-selected measurement scenario with HGn pointer, where the normalized Berry curvature is given as \({\tilde{{{{{{{{\mathcal{C}}}}}}}}}}_{12}=\frac{1}{2n+1}\). Then the Holevo bound for the incompatible parameters g1 and g2 generated by the momentum operator \(\hat{P}\) and position operator \(\hat{X}\) can be calculated as
By comparing it with the trade-off bound of Eq. (15) in Fig. 8, we can see that the Holevo bound is tangent to the trade-off bound at \(\sqrt{\nu }\delta {\tilde{g}}_{i}=\sqrt{\nu }\delta {\tilde{g}}_{j}=\sqrt{\frac{2(2n+1)}{2n+1+2\sqrt{n(n+1)}}}\), and the trade-off bound is more informative than the Holevo bound.
In summary, this study has identified a practical way to approach the QL point of incompatible parameters asymptotically, which was considered unachievable. By connecting the estimation errors of parameters with the variances of corresponding generators, we have proposed a criterion to improve the trade-off precision bound from the physical insight. This significant criterion indicates that the incompatibility is able to be mitigated via increasing the corresponding generators’ variances simultaneously, where devising an appropriate probe state is important. For demonstration, we have build up a practical scheme for measuring the incompatible parameters of momentum and position simultaneously in a quantum system, and a corresponding optical experiment has also been implemented on the simultaneous measurement of light beam’s transverse displacement and angular tilt. By employing the HG states as the probe, the QL point of the incompatible parameters has been approached asymptotically in both theoretical frame and experimental results. Furthermore, our method is able to improve the measurement precisions, because increasing the generators’ variances also decreases the ultimate estimation errors of unknown parameters. Experimentally, we have achieved the precisions up to 1.45 nm and 4.08 nrad on the simultaneous measurement of spatial displacement and angular tilt of light. Although only the spatial incompatible parameters are experimentally exemplified, our theoretical analysis is perfectly applicable to the homodyne detection of coherent light in the phase space53. Therefore, the theoretical and experimental findings in this study not only contribute to develop and refine the quantum multiparameter estimation theory, but also have potential for other quantum optics applications, such as quantum communications54,55 and superresolution8,56.
Methods
Technical advantages of weak value
To practically demonstrate our theory, we employed the post-selected weak measurement scheme with weak value amplification technique to measure the incompatible parameters simultaneously. The weak value Aw ≈ 1/ε takes no enhancement for the theoretical minimum detectable parameters because the detected photons number \(\nu={\left|\langle f|i\rangle \right|}^{2}{\nu }_{0}={\sin }^{2}\frac{\varepsilon }{2}{\nu }_{0}\) is attenuated by the post-selection, where ν0 is the photons number before post-selection. However, the weak value amplification technology has been proved efficient for suppressing technical noises, such as reflection of optical elements2 and detector saturation33,57,58. Especially, the detector saturation is non-negligible in our experiment for the saturation power of our APD detector is only 1.54 nW. Considering the projection demodulation of SLM, only 10% photons can be modulated on the 1st-order diffraction, so the maximum received power of our detector is ~154 pW, which is easily saturated without post-selection. For example, the efficient detected light power in our experiment is I0 = 49.09 pW, and the post-selection angle ε = 5∘. Therefore, for the post-selection-free scheme, a \({I}_{0}/{\sin }^{2}\frac{\varepsilon }{2}=\,{{\mbox{25.8}}}\,\,\,{{\mbox{nW}}}\) detected light power is needed to achieve the same precision of the post-selected scheme, which is far lager than the saturation power of the APD detector.
Experimental materials
The laser employed in this experiment is a Distributed Bragg Reflector (DBR) Single-Frequency Laser of of Thorlabs Inc. (part number: DBR780PN), which works at λ = 780 nm with 1 MHz typical linewidth. To generate the high-order HG beams, we used a SLM of Hamamatsu Photonics (part number: X13138-02), which has 1272 × 1024 pixels with 12.5 μm pixel pitch. The focal length of the Fourier lens in the 4-f system is 5 cm. A 200 μm square pinhole is used as the spatial filter.
In this work, we set up a polarized MZI to generate the position displacement and momentum kick interaction simultaneously for the weak measurement scheme. To improve th beam’s degree of polarization, two additional polarizers were inserted into two optical arms of the interferometer. Moreover, a lock-in amplifier was used to stabilize the relative phase of two optical path in the MZI. In the experiment, we pasted 2 PZTs on the back of the signal mirror (see the Experimental materials part). Then we exerted two f = 2 kHz cosine driving signals with a relative phase θ on the two PZTs separately. The interval between these two PZTs is 20 mm, and the part number of these PZTs is NAC2013 of Core Tomorrow Company, which shifts 22nm with 1V driving voltage. Thus, when setting the relative phase θ = 0∘, there is only a 11 nm shift signal of mirror with 1 Vpp driving Voltage, which leads to a d = 15.56 nm transverse displacement signal of light beam. In contrast, when setting the relative phase θ = 180∘, there is only a 1.1 μrad tilt signal of mirror (φ = 2.2 μrad angular tilt of light beam) with 1 Vpp driving Voltage, which leads to a kφ = 17.72 m−1 momentum kick signal of light beam, where k = 2π/λ = 8.06 × 106 m−1 is the wave number of laser beam.
In this experiment, we modulated the waist radius of fundamental Gaussian beam as w0 = 2σ0 = 240 μm and set the relative phase of driving signal as θ = 4∘. Then the 1 Vpp driving signal of PZTs corresponds to the unit spatial displacement amplitude du ≈ 15.55 nm/V and the unit angular tilt amplitude φu ≈ 76.78 nrad/V. Besides, the misaligned bias of PZT mirror caused an initial displacement bias dΔ, which is on the 104 nm scale (scale of w0/10), and an initial angular tilt bias φΔ, which is on the mrad scale. Thus, the total displacement signal is \({d}^{{{{{{{{\rm{tot}}}}}}}}}={d}^{{{\Delta }}}+d\cos (2\pi ft)\) and the total tilt signal \({\varphi }^{{{{{{{{\rm{tot}}}}}}}}}={\varphi }^{{{\Delta }}}+\varphi \sin (2\pi ft)\). It is easy to determine that d << dΔ << 1 and φ << φΔ << 1. Moreover, the optical lengths z1 = −27.2 cm, z2 = 64 cm in our experiment. Thus, the total modulated signals of the incompatible parameters \({g}_{1}^{{{{{{{{\rm{tot}}}}}}}}}={d}^{{{{{{{{\rm{tot}}}}}}}}}+{z}_{1}{\varphi }^{{{{{{{{\rm{tot}}}}}}}}}={g}_{1}^{{{\Delta }}}+{g}_{1}\cos (2\pi ft)\) and \({g}_{2}^{{{{{{{{\rm{tot}}}}}}}}}=k{\varphi }^{{{{{{{{\rm{tot}}}}}}}}}={g}_{2}^{{{\Delta }}}+{g}_{2}\cos (2\pi ft)\). Thus, the modulated signals’ amplitudes of the incompatible parameters at f = 2 kHz are \({g}_{1}=\sqrt{{d}^{2}+{z}_{1}^{2}{\varphi }^{2}}\) and g2 = kφ, which lead to \({g}_{1}^{{{{{{{{\rm{u}}}}}}}}}\,\approx \,{{\mbox{26.03}}}\,\,\,{{\mbox{nm/V}}}\) and \({g}_{2}^{{{{{{{{\rm{u}}}}}}}}}\,\approx \,0.62\,{{{{{{{{\rm{m}}}}}}}}}^{-1}/{{{{{{{\rm{V}}}}}}}}\).
In practice, by projecting the final beam state on \(\left|{u}_{n}({z}_{0})\right\rangle\), we determined the effective sample number ν = Nτ, where N is the photon number in unit time and τ is the detecting time length. In this experiment, a Si Avalanche Photodetector (part number: APD440A of Thorlabs Inc.) was employed to receive the projection signal, which has maximum conversion gain of 2.65 × 109 V/W and 100 kHz bandwidth. The detected optical power of APD on state \(\left|{u}_{n}({z}_{0})\right\rangle\) was fixed as I0 = 49.06 pW for different HG modes, which leads to N = 1.92 × 108 s−1. Then the detected voltage signal was analyzed by the spectrum analyzer module of Moku:Lab, which is a reconfigurable hardware platform produced by Liquid instruments. The resolution bandwidth (RWB) of our spectrum analyzer was 18.34 Hz, which leads to the detecting time of τ = 54.53 ms. Thus, the effective sample number in our experiment is fixed as ν = 1.05 × 107.
Operator algebra for HG state
From the view of quantum mechanics, ψn(x) is the time-independent solution for the Schr\(\ddot{{{{{{{{\rm{o}}}}}}}}}\)dinger equation of harmonic oscillators:
For eigenvalue \({E}_{n}=(n+\frac{1}{2})\), the corresponding eigenket can be obtained as:
Thus, we can employ the mode creation (annihilation) operators \(\hat{a}({\hat{a}}^{{{{\dagger}}} })\) for HG state:
Then the higher-order HG state can be obtained from the fundamental Gaussian state with the creation operator:
Besides, the momentum operator \(\hat{P}\) and position operator \(\hat{X}\) can be also represented by creation and annihilation operators:
Substituting Eq. (50) into Eq. (7), it is easy to calculate the final pointer state with n-order HG state as:
where the generated states \(\left|{\psi }_{\hat{P}}\right\rangle\) and \(\left|{\psi }_{\hat{X}}\right\rangle\) have been given in Eq. (21).
Propagation of HG beams
The z-dependent wave function of n-order HG beam is40
where the three z-dependent parameters: spatial variance of fundamental Gaussian beam σ2, Gouy phase χ and curvature radius of the wavefront q can be determined by equalities:
Here k = 2π/λ is the wave number of light beam and \(b=2k{\sigma }_{0}^{2}\) is the Rayleigh range59. Then we denote \(\left|{u}_{n}(z)\right\rangle=\int{{{{{{{\rm{d}}}}}}}}x{u}_{n}(x,z)\left|x\right\rangle\), obviously, \(\left|{u}_{n}(0)\right\rangle=\left|n\right\rangle\). The HG beams are solutions of the paraxial wave equation
which can be rewritten as
This equation has the formal solution \(\left|{u}_{n}(z)\right\rangle=\hat{U}(z)\left|{u}_{n}(0)\right\rangle\) with the propagation operator
Thus, the z-dependent creation (annihilation) operators are given by \(\hat{a}(z)=\hat{U}(z)\hat{a}{\hat{U}}^{{{{\dagger}}} }(z)\) and \({\hat{a}}^{{{{\dagger}}} }(z)=\hat{U}(z){\hat{a}}^{{{{\dagger}}} }{\hat{U}}^{{{{\dagger}}} }(z)\). Hence, the higher-order HG beam state can also be obtained by the fundamental state according to
Moreover, the z-dependent momentum and position operators \(\hat{P}(z)\) and \(\hat{X}(z)\) for free propagation can be derived as:
According to the experimental set-up, the final state of the whole system can be calculated by:
where \(\hat{U}({{{{{{{\boldsymbol{g}}}}}}}})=\hat{U}({z}_{2}){\hat{U}}_{{{{{{{{\rm{w}}}}}}}}}^{\exp }{\hat{U}}^{{{{\dagger}}} }({z}_{2})\) is the unitary parameterization in the experiment, and it can be expressed with \(\hat{P}({z}_{0})\) and \(\hat{X}({z}_{0})\) by:
where g1 = d + z1φ and g2 = kφ. This expression is derived from the relations:
Substituting Eq. (59) into Eq. (58), the final beam state \(|{u}_{f}({z}_{0})\rangle\) in Eq. (31) is finally calculated by
Thus, the projective states \(\left|{u}_{\hat{P}}\right\rangle=\hat{U}({z}_{0})\left|{\psi }_{\hat{P}}\right\rangle\) and \(\left|{u}_{\hat{X}}\right\rangle=\hat{U}({z}_{0})\left|{\psi }_{\hat{X}}\right\rangle\) in the experiment. Moreover, the normalized parameters \({\tilde{g}}_{1}\) and \({\tilde{g}}_{2}\) in the experiment are still given by \({\tilde{g}}_{1}={A}_{w}\sqrt{2n+1}{g}_{1}/{\sigma }_{0}\) and \({\tilde{g}}_{2}=2{A}_{w}{\sigma }_{0}\sqrt{2n+1}{g}_{1}\).
SNR calculation
In the experiment, the detected optical power of APD on state \(\left|{u}_{n}({z}_{0})\right\rangle\) is denoted as I0, which was fixed for different HG modes. Exerting the driving signals on PZT chips and separately projecting the final beam on states \(|{u}_{\hat{X}}^{\perp }\rangle\) and \(|{u}_{\hat{P}}^{\perp }\rangle\), then the corresponding detected optical powers are calculated as:
Inputting the detected power signals of APD into the spectrum analyzer, where we can independently demodulate the parameters g1 and g2 at f = 2 kHz from the corresponding peak powers \({I}_{1}^{(2\,{{{{{{{\rm{kHz}}}}}}}})}\) and \({I}_{2}^{(2\,{{{{{{{\rm{kHz}}}}}}}})}\) in Eq. (34). Besides, the corresponding detected shot noises of APD when displaying measurements \({\hat{{{\Pi }}}}_{1}=|{u}_{\hat{X}}^{\perp }\rangle \langle {u}_{\hat{X}}^{\perp }|\) and \({\hat{{{\Pi }}}}_{2}=|{u}_{\hat{P}}^{\perp }\rangle \langle {u}_{\hat{P}}^{\perp }|\) can be separately calculated as:
Theoretically, the effective optical power of final beam state is I0 = γν/τ, where γ is the single photon’s energy at λ = 780 nm. Then the corresponding shot noise of final beam state is given by \(\delta {I}_{0}=\gamma \delta \nu /\tau=\gamma \sqrt{\nu }/\tau\). Thus, the theoretical detected peak signal-to-noise ratios SNR1 and SNR2 of our experimental scheme when displaying measurements \({\hat{{{\Pi }}}}_{1}\) and \({\hat{{{\Pi }}}}_{2}\) can be obtained in Eq. (35).
Data availability
The data that support the findings of this study are available within the paper and its Supplementary Information. Any additional information is available from the corresponding authors upon request.
References
Haine, S. A. Mean-field dynamics and fisher information in matter wave interferometry. Phys. Rev. Lett. 116, 230404 (2016).
Fang, C., Huang, J.-Z. & Zeng, G. Robust interferometry against imperfections based on weak value amplification. Phys. Rev. A 97, 063818 (2018).
Fang, C., Huang, J.-Z., Li, H., Li, Y. & Zeng, G. Improving precision of mach-zehnder interferometer with compensation employing weak measurement. Appl. Phys. Lett. 115, 031101 (2019).
Zhao, D. et al. Type of non-reciprocity in a fiber sagnac interferometer induced by geometric phases. Opt. Express 30, 12 (2022).
Dowling, J. P. & Seshadreesan, K. P. Quantum optical technologies for metrology, sensing, and imaging. J. Lightw. Technol. 33, 2359 (2015).
Genovese, M. Real applications of quantum imaging. J. Optics 18, 073002 (2016).
Tsang, M., Nair, R. & Lu, X.-M. Quantum theory of superresolution for two incoherent optical point sources. Phys. Rev. X 6, 031033 (2016).
Tham, W.-K., Ferretti, H. & Steinberg, A. M. Beating rayleigh’s curse by imaging using phase information. Phys. Rev. Lett. 118, 070801 (2017).
Adhikari, R. X. Gravitational radiation detection with laser interferometry. Rev. Mod. Phys. 86, 121 (2014).
Degen, C. L., Reinhard, F. & Cappellaro, P. Quantum sensing. Rev. Mod. Phys. 89, 035002 (2017).
Liu, M. et al. High-precision temperature measurement with adjustable operating range based on weak measurement. J. Phys. B At. Mol. Opt. Phys. 54, 085501 (2021).
Helstrom, C. Minimum mean-squared error of estimates in quantum statistics. Phys. Lett. A 25, 101 (1967).
Helstrom, C. The minimum variance of estimates in quantum signal detection. IEEE Trans. Inf. Theory 14, 234 (1968).
R., Demkowicz-Dobrzański, M., Jarzyna, and J., Kołodyński. Chapter four - quantum limits in optical interferometry (Elsevier, 2015) pp. 345–435
Viii quantum estimation theory. In: Quantum Detection and Estimation Theory, Mathematics in Science and Engineering https://doi.org/10.1016/S0076-5392(08)60258-1, Vol. 123, edited by C. W. Helstrom, pp. 235–293 (Elsevier, 1976).
Szczykulska, M., Baumgratz, T. & Datta, A. Multi-parameter quantum metrology. Adv. Phys: X 1, 621 (2016).
Liu, J., Yuan, H., Lu, X.-M. & Wang, X. Quantum fisher information matrix and multiparameter estimation. J. Phys. A: Math. Theor. 53, 023001 (2019).
A. Holevo, Unbiased measurements. In https://doi.org/10.1007/978-88-7642-378-9_6Probabilistic and Statistical Aspects of Quantum Theory, pp. 219–264 (Edizioni della Normale, Pisa, 2011).
Yang, Y., Chiribella, G. & Hayashi, M. Attaining the ultimate precision limit in quantum state estimation. Commun. Math. Phys. 368, 223 (2019).
Pezzè, L. et al. Optimal measurements for simultaneous quantum estimation of multiple phases. Phys. Rev. Lett. 119, 130504 (2017).
Roccia, E. et al. Multiparameter approach to quantum phase estimation with limited visibility. Optica 5, 1171 (2018).
Hou, Z. et al. Minimal tradeoff and ultimate precision limit of multiparameter quantum magnetometry under the parallel scheme. Phys. Rev. Lett. 125, 020501 (2020).
Hou, Z. et al. Zero-trade-off multiparameter quantum estimation via simultaneously saturating multiple heisenberg uncertainty relations. Sci. Adv. 7, eabd2986 (2021).
Guo, W., Zhong, W., Jing, X.-X., Fu, L.-B. & Wang, X. Berry curvature as a lower bound for multiparameter estimation. Phys. Rev. A 93, 042115 (2016).
Fujiwara, A. & Nagaoka, H. Quantum fisher metric and estimation for pure state models. Phys. Lett. A 201, 119 (1995).
Busch, P., Heinonen, T. & Lahti, P. Heisenberg’s uncertainty principle. Phys. Rep. 452, 155 (2007).
Lu, X.-M. & Wang, X. Incorporating heisenberg’s uncertainty principle into quantum multiparameter estimation. Phys. Rev. Lett. 126, 120503 (2021).
Ozawa, M. Uncertainty relations for joint measurements of noncommuting observables. Phys. Lett. A 320, 367 (2004).
Branciard, C. Error-tradeoff and error-disturbance relations for incompatible quantum measurements. Proc. Natl. Acad. Sci. 110, 6742 (2013).
Giovannetti, V., Lloyd, S. & Maccone, L. Quantum metrology. Phys. Rev. Lett. 96, 010401 (2006).
Jordan, A. N., Martínez-Rincón, J. & Howell, J. C. Technical advantages for weak-value amplification: when less is more. Phys. Rev. X 4, 011031 (2014).
Magaña-Loaiza, O. S., Harris, J., Lundeen, J. S. & Boyd, R. W. Weak-value measurements can outperform conventional measurements. Phys. Scr. 92, 023001 (2016).
Harris, J., Boyd, R. W. & Lundeen, J. S. Weak value amplification can outperform conventional measurement in the presence of detector saturation. Phys. Rev. Lett. 118, 070802 (2017).
Israel, Y., Rosen, S. & Silberberg, Y. Supersensitive polarization microscopy using noon states of light. Phys. Rev. Lett. 112, 103604 (2014).
Hou, Z., Zhu, H., Xiang, G.-Y., Li, C.-F. & Guo, G.-C. Achieving quantum precision limit in adaptive qubit state tomography. npj Quantum Inf. 2, 16001 (2016).
Baumgratz, T. & Datta, A. Quantum enhanced estimation of a multidimensional field. Phys. Rev. Lett. 116, 030801 (2016).
Birchall, P. M. et al. Quantum optical metrology of correlated phase and loss. Phys. Rev. Lett. 124, 140501 (2020).
Vidrighin, M. D. et al. Joint estimation of phase and phase diffusion for quantum metrology. Nat. Commun. 5, 3532 (2014).
Hayashi, M. Asymptotic Theory of Quantum Statistical Inference. https://doi.org/10.1142/5630 (WORLD SCIENTIFIC, 2005).
Nienhuis, G. & Allen, L. Paraxial wave optics and harmonic oscillators. Phys. Rev. A 48, 656 (1993).
Yang, J., Pang, S., Zhou, Y. & Jordan, A. N. Optimal measurements for quantum multiparameter estimation with general states. Phys. Rev. A 100, 032104 (2019).
Bergou, J. A., Herzog, U.& Hillery, M. 11 discrimination of quantum states, in https://doi.org/10.1007/978-3-540-44481-7_11Quantum State Estimation, edited by M. Paris and J. R^eháček (Springer Berlin Heidelberg, Berlin, Heidelberg, 2004) pp. 417–465.
Chefles, A. Quantum state discrimination. Contemp. Phys. 41, 401 (2000).
Clark, T. W., Offer, R. F., Franke-Arnold, S., Arnold, A. S. & Radwell, N. Comparison of beam generation techniques using a phase only spatial light modulator. Opt. Express 24, 6249 (2016).
Abe, S. Quantized geometry associated with uncertainty and correlation. Phys. Rev. A 48, 4102 (1993).
Campos Venuti, L. & Zanardi, P. Quantum critical scaling of the geometric tensors. Phys. Rev. Lett. 99, 095701 (2007).
Provost, J. P. & Vallee, G. Riemannian structure on manifolds of quantum states. Commun. Math. Phys. 76, 289 (1980).
Yamagata, K., Fujiwara, A. & Gill, R. D. Quantum local asymptotic normality based on a new quantum likelihood ratio. Ann. Stat. 41, 2197 (2013).
Hayashi, M. & Matsumoto, K. Asymptotic performance of optimal state estimation in qubit system. J. Math. Phys. 49, 102101 (2008).
Demkowicz-Dobrzański, R., Górecki, W. & Guţă, M. Multi-parameter estimation beyond quantum fisher information. J. Phys. A: Math. Theor. 53, 363001 (2020).
Sidhu, J. S., Ouyang, Y., Campbell, E. T. & Kok, P. Tight bounds on the simultaneous estimation of incompatible parameters. Phys. Rev. X 11, 011028 (2021).
Matsumoto, K. A new approach to the cramér-rao-type bound of the pure-state model. J. Phys. A: Math. Gen. 35, 3111 (2002).
Helstrom, C. W. Cramér-rao inequalities for operator-valued measures in quantum mechanics. Int. J. Theor. Phys. 8, 361 (1973).
Simon, D. S., Jaeger, G. & Sergienko, A. V. Quantum communication and cryptography In https://doi.org/10.1007/978-3-319-46551-7_9Quantum Metrology, Imaging, and Communication, pp. 201–220n (Springer International Publishing, Cham, 2017).
Wang, S., Huang, P., Wang, T. & Zeng, G. Feasibility of all-day quantum communication with coherent detection. Phys. Rev. Applied 12, 024041 (2019).
Gessner, M., Fabre, C. & Treps, N. Superresolution limits from measurement crosstalk. Phys. Rev. Lett. 125, 100501 (2020).
Xu, L., Liu, Z. & Zhang, L. Weak-measurement-enhanced metrology in the presence of ccd noise and saturation, in https://doi.org/10.1364/FIO.2018.JW4A.126Frontiers in Optics/Laser Science, paper JW4A.126 (Optica Publishing Group, 2018).
Xu, L. et al. Approaching quantum-limited metrology with imperfect detectors by using weak-value amplification. Phys. Rev. Lett. 125, 080501 (2020).
Nienhuis, G. Analogies between optical and quantum mechanical angular momentum. Philos. Trans. A Math. Phys. Eng. Sci. 375, 20150443 (2017).
Acknowledgements
We thank professor Guoyong Xiang for the helpful discussions. B.X. thanks Miaomiao Liu and Zhiyue Zuo for their help in setting up the experiment. The authors are thankful for the financial support from the National Natural Science Foundation of China (Grants No.62071298, No. 61671287, No.61631014, and No. 61901258) and the fund of the State Key Laboratory of Advanced Optical Communication Systems and Networks.
Author information
Authors and Affiliations
Contributions
G.Z. conceived the research project, J.H. designed the scheme, B.X. constructed the theoretical model and carried out the experiments with assistance from J.H., H.L., H.W., and B.X. analyzed the data. B.X. and J.H. wrote the manuscript with contributions from all authors.
Corresponding authors
Ethics declarations
Competing interests
The authors declare no competing interests.
Peer review
Peer review information
Nature Communications thanks Xiao-Ming Lu, and the other, anonymous, reviewer(s) for their contribution to the peer review of this work. Peer reviewer reports are available.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Xia, B., Huang, J., Li, H. et al. Toward incompatible quantum limits on multiparameter estimation. Nat Commun 14, 1021 (2023). https://doi.org/10.1038/s41467-023-36661-3
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41467-023-36661-3
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.