Abstract
Three dimensional scaffolded DNA origami with inorganic nanoparticles has been used to create tailored multidimensional nanostructures. However, the image contrast of DNA is poorer than those of the heavy nanoparticles in conventional transmission electron microscopy at high defocus so that the biological and non-biological components in 3D scaffolds cannot be simultaneously resolved using tomography of samples in a native state. We demonstrate the use of electron ptychography to recover high contrast phase information from all components in a DNA origami scaffold without staining. We further quantitatively evaluate the enhancement of contrast in comparison with conventional transmission electron microscopy. In addition, We show that for ptychography post-reconstruction focusing simplifies the workflow and reduces electron dose and beam damage.
Introduction
Structural DNA nanotechnology using templating techniques for material construction, was first proposed in the early 1980s by Seeman1 and has rapidly developed since 20062. This development of DNA origami technology has shown great potential in a wide range of applications, including biomedicine3,4,5, biocomputing6, biochips and nano-circuits7,8, biomimicry9, masks for lithography10,11, and nano-mechanics12. All of these applications are based on the fact that a single DNA strand can be self-assembled into different two-dimensional (2D) and three-dimensional (3D) structures. In addition, spherical nanoparticles can be embedded in these structured DNA molecules as reported by Mirkin et al.13 and Alivisatos et al.14 and nanoparticle-capped DNA can be utilised as building blocks to build highly-ordered 3D lattice structures15,16, with a range of novel properties17,18,19. The physical properties of these are fundamentally determined by the relationship between the inorganic and biological components in the nano hybrid constructs which requires high-resolution 3D imaging of both the biological and non-biological components for characterisation.
Transmission electron microscopy (TEM), is a high resolution imaging technique, and is regarded as an essential tool for the characterisation of both biological and non-biological materials. Three dimensional imaging methods, such as single particle analysis (SPA)20 and electron tomography (ET)21,22, are widely used for 3D structural analysis of biological samples, and have recently been used in studies of DNA based structures23,24. SPA reconstruction, relies on computationally averaging thousands of images of identical particles (e.g., virus), and is more challenging to apply to heterogeneous samples with low symmetry. In contrast, ET, which is performed by recording a tilt series of projections of a single specimen, is more suitable for reconstructing the structure of non-identical biological samples such as 3D frameworks of DNA origami. Nevertheless, both of these approaches rely on the use of conventional phase contrast TEM images. It is well known that unstained biological samples, which are extremely radiation-sensitive and can be treated as pure phase objects. This offen results in images with low signal-to-noise ratio and low contrast, which can cause difficulties in the tomographic reconstruction. To enhance the contrast, samples of DNA origami frameworks in previous studies were prepared with staining25,26. However, the heavy metal ions used in the staining procedure can potentially damage the fine structure of native-state DNA27. An alternative to increase contrast at low spatial frequencies is to use high defocus values, but this leads to rapid oscillations in the phase contrast transfer function (CTF) at intermediate and high spatial frequencies if not corrected, for instance, by exit-wave restoration methods28. This poses a challenge to directly provide high-resolution 3D images of DNA frameworks, and to simultaneously visualise both the biological and non-biological components in their native state without staining.
Ptychography, as originally proposed by Hoppe29, is an alternative phase retrieval method related to coherent diffraction imaging30,31. The development of iterative algorithms32,33,34 has made ptychography capable of achieving superior spatial resolution compared to that obtained from conventional optics31, especially for extended non-crystalline samples32. Ptychography is now widely used in 2D imaging using both light35 and X-rays30,32 and in 3D imaging36,37,38,39,40. In TEM, it has also attracted considerable interest with a variety of potential applications in super-resolution imaging41,42,43,44,45, high-contrast light-element detection46,47, optical sectioning46,48, coupling to spectroscopic data acquisition49 and low-dose imaging50,51,52, using direct electron detectors53,54. Recent numerical simulations have shown that combining ptychography and electron tomography has the potential to reach atomic 3D reconstructions for inorganic materials55. Importantly, ptychography has a tunable and continuous wide-band information transfer, which can be adjusted using the probe-forming convergence angles which is important for biological applications. To transfer information from objects with larger length scales, the illumination can be further optimised to a smaller convergence angle56. This advantage has recently been demonstrated for organic matter (such as unstained virus particles), which were successfully reconstructed at a dose of 27 e−/Å2 in their native state56. We now propose that high-contrast 2D phase data reconstructed using ptychographic methods and recorded at different sample orientations can be aligned and used as an input to a tomographic reconstruction for unstained biological samples (such as DNA origami frameworks) with high resolution.
We demonstrate high-contrast 3D phase reconstructions to visualise unstained DNA origami with gold nanoparticles by combining electron ptychography and tomography. In comparison to conventional TEM, the enhancement of contrast was quantitatively evaluated under various electron dose conditions and accelerating voltages. Ptychography not only provides images with better contrast, but also simplifies the conventional tomographic workflow by reducing the electron dose and preventing radiation damage during tilting. Thus, electron ptychographic tomography (EPty-Tomo) developed as described here shows promise for revealing the relationship between 3D structures of hybrid nano-constructs fabricated with biomolecules and inorganic nanomaterials as used in aspects of nanotechnology.
Results
3D ptychographic tomography (EPty-Tomo)
The schematic experimental setup used is illustrated in Fig. 1a. Samples of unstained DNA origami with gold nanoparticles were suspended on an ultrathin carbon film at room temperature for TEM studies (see Supplementary Note 1: Sample Preparation). A tilt series of ptychography-based tomography was acquired using a + /− 70° double tilt holder (Fischione Model 2040) on a double aberration-corrected FEI Titan Cubed G2 60–300 (S)TEM operated at 60 kV accelerating voltage to reduce beam damage. A defocused electron probe with a diameter of approximately 120 nm was incident on the sample with a convergence angle of 1.5 mrad and a nominal defocus of −40 μm. The choice of a small convergence angle was to enhance low spatial frequency transfer56 with a large depth of field, which is an advantage when using thick specimens57. At each tilt angle, ptychographic datasets were acquired by illuminating the sample with a scanning probe, recording 10 × 10 far-field diffraction patterns (as shown in Supplementary Fig. 1) as a function of probe position (see Supplementary Note 2: Tilt-series Ptychographic Data Acquisition). This gave rise to a total ptychographic dataset for 23 tilt angles of approximately 39 GB. The 2D complex wavefunction of the sample at each tilt was recovered using the extended ptychographic iterative engine (ePIE)33 (see Supplementary Note 3: 2D Ptychographic Reconstruction). The phases of the tilt-series complex functions (see Supplementary Fig. 2) were used as inputs for sequential tomography reconstruction implemented using the GENeralized Fourier Iterative Reconstruction (GENFIRE) algorithm58 to calculate a final 3D reconstruction (see Supplementary Note 4: 3D Tomographic Reconstruction).
a Schematic diagram of the experimental setup. b 3D rendering of the phase-contrast of a DNA origami framework reconstructed from a ptychographic tomographic dataset. c Frequency histogram of the background (green), DNA strands (orange) and gold nanoparticles (light blue) indicated by coloured boxes in (b).
The 3D phase reconstruction from ptychographic tomography is shown in Fig. 1b and Fig. 2. The 3D phase rendering of the unstained DNA origami structures with gold nanoparticles indicates that the DNA framework collapsed onto the carbon film due to the drop-cast sample preparation used. However, the side view and cross-section (Fig. 2a and Supplementary Fig. 3c) of the volume shows two adjacent gold nanoparticles spaced 5.5 nm apart along the z-axis. More importantly, the DNA strands together with the gold nanoparticles can both be resolved with high contrast in the 3D phase reconstruction. This is supported by the fact that the peaks of DNA strand and gold nanoparticles in the frequency histogram (Fig. 1c) are both separated from the background. A part of the reconstruction and its related video was also extracted, as shown in Fig. 2b and Supplementary Movie 1; Note that to reveal the gold particle core the signal of the DNA outer layer within the orange box is not rendered. An outer layer of signal surrounding the gold nanoparticles in the 3D phase reconstruction directly revealed the formation of core-shell structures in the scaffold. This outer layer of signal is attributed to a layer of DNA short strands formed from a spherical nucleic acid conjugate59. In contrast, ET, based on conventional defocused contrast TEM images (Supplementary Fig. 4), has difficulties in directly resolving the 3D structures of the biological and non-biological materials simultaneously. This is due to the low contrast of the biomolecules compared with that of gold nanoparticles, which will be discussed quantitatively in detail subsequently.
Contrast quantification of DNA strands
In this study, EPty-Tomo exhibits two main advantages over conventional TEM based tomography. Firstly, reconstruction using ptychographic tomography shows an enhanced contrast from weakly scattering objects (unstained DNA strands), even though they are attached to strongly scattering material (gold nanoparticles). As a result, we could directly render the outer layer of the DNA short strands around the gold nanoparticles (Fig. 2b) which cannot be performed using conventional TEM tomography (Supplementary Fig. 4), unless the DNA strands are stained to boost contrast in the 2D TEM images that form the datasets used for tomographic reconstruction60. To quantify the contrast, the 3D phases were normalised with respect to the signals of the gold nanoparticles and the carbon film background (See Supplementary Note 5: Normalisation and Contrast Ratio). The signals of the carbon film background, DNA strands and gold nanoparticles were subsequently extracted from volumes with the equal number of the voxels as indicated with green, orange, and light blue frames in Fig. 1b and Supplementary Fig. 3, respectively. Finally, the normalised frequency histogram based on the extracted voxels was plotted as shown in Fig. 1c. The normalised phase of the DNA strands was localised within a narrow peak (orange) and was sufficiently high to be clearly distinguished from the carbon film background (green) by 0.17 (as a value of normalised intensity, this value is dimensionless. see Supplementary Note 6: Rendering and Histogram Analysis). This offset allows the contrast of the former to be directly separated from that of the latter in the 3D render. This result originates from the high-contrast 2D ptychographic phase reconstruction at each tilt (Supplementary Fig. 2), in which the contrast of DNA strands is higher than that of the conventional TEM images56. Figure 3a–c shows the normalised 2D ptychographic phase reconstructions at different electron doses of 88, 45 and 26 e−/Å2 varied by probe overlap ratios. As shown in the frequency histograms of the normalised data (Fig. 3f–h), the offset between the positions of the DNA and background peaks reduces from 0.24 to 0.15 with decreasing dose, confirming that the contrast in ptychographic reconstructions is dose-dependent51. As the data is normalised, the offset values can be considered as a contrast ratio (R), given by Eq. (1):
where RDNA/gold stands is the contrast ratio of the DNA strands and gold nanoparticles; PDNA and Pbkgd is the intensity value (x-axis coordinate) at the peaks of the DNA strands and background in the frequency histograms, and Pgold is the mean value of the normalised intensity of a gold nanoparticle. Hence, larger RDNA/gold values indicate higher visibility of the DNA strands with respect to the background and gold nanoparticles.
a–c Normalised 2D ptychographic phases with doses of 88, 45 and 26 e−/Å2, respectively. Reconstructed with independent randomly initialised phase guesses (as shown in Supplementary Fig. 9). d, e Normalised representative TEM images (from a set of typically 20 recorded) with doses of 27 e−/Å2 and defoci of −0.1 and −2.8 μm, respectively. f–j Frequency histograms of the background and DNA strands for a–e, respectively. k Line profiles extracted from the positions indicated by white lines in a–e. l Resolution estimates of the ptychographic reconstructions using Fourier ring correlation. Blue and green curves are calculated using two reconstructions at 45 and 26 e−/Å2, respectively.
For comparison, a defocus-series of TEM images were also obtained over a range of defocus values from −0.1 μm to −8.9 μm (Supplementary Fig. 5a). The histograms of the original images (Supplementary Fig. 5b) shows that the contrast of the standalone DNA strands could only be increased by few tens of counts with increasing defoci. whereas, the peak positions of the gold nanoparticles at frequency histograms (Supplementary Fig. 5b) were increased by a few hundred in intensity. As a result, the R values remain low around 0.07 in the histograms (i.e. defoci of −0.1 and −2.8 μm, as shown in Fig. 3i, j, with data for other defoci shown in Supplementary Fig. 5e). Hence, the visibility of the DNA strands with respect to the gold nanoparticles is not improved with increasing defocus. In addition, larger defoci (−8.9 μm) leads to visible Fresnel fringes around the gold nanoparticles (shown in Supplementary Fig. 5a), which completely suppresses the contrast of the DNA short strands at the surface of gold nanoparticles. Thus, it is clearly challenging to resolve biological molecules around inorganic nanoparticles with high contrast and resolution using defocused TEM images. However, for the 2D ptychographic phases (Fig. 3a–c), the R value (0.24 – 0.15 in Fig. 3f–h) was two-fold higher than any defocused TEM data, so that DNA samples were imaged with higher contrast as shown in the line profiles across the DNA strands (Fig. 3k).
The ptychographic phase can reflect the relative thickness of the sample61. In this work, the normalised phase at the intersection of two DNA strands (0.40) is approximately twice that of a single DNA strand (0.21), as shown in Fig. 3k suggesting that the phase signal is quantitative for this sample61,62.
Resolution of 3D reconstructions
The second advantage of EPty-Tomo is the capability to achieve a optimised resolution, the bandwidth of which can be controlled by changing the convergence semi-angle of the probe. To evaluate the 3D resolution, Fourier shell correlation (FSC)63, as conventionally used in tomography, was employed to evaluate the degree of correlation between two tomographic reconstructions at different spatial frequencies. The FSC was calculated using the full dataset (90 diffraction patterns at each projection) split into two independent datasets (45 diffraction patterns at each projection, as shown schematically in Supplementary Fig. 6) which were used for independent reconstructions, one of which is shown in Supplementary Fig. 7a. Details of the FSC analysis can be found in Supplementary Note 7: FSC and FRC and the FSC as a function of spatial frequency is shown in Supplementary Fig. 7b. Using this approach, the 3D resolution was estimated as 2.08 nm for a 0.5-bit criterion. It is established that the resolution of 3D reconstruction is determined by both the number of tilt angles and the resolution of individual 2D projections64. The theoretical resolution for 2D ptychography (two-dimensional projections in this 3D reconstruction) can be expressed as λ/(α + β), where λ is the electron wavelength, α is the convergence angle and β is the collection angle65. Since the DNA strands used here were weakly scattering objects and almost transparent to the electron beam, the signal scattered outside of the bright field disc is negligible. Therefore, in this work only the signal within the bright field disc is used for the ptychographic reconstruction, such that the 2D theoretical resolution, evaluated as λ/(2α) was 1.62 nm, in agreement with the result of experimental 2D phase-contrast resolution (Fig. 3i) achieved. The resolution of conventional phase contrast TEM imaging was defined by the first zero crossing of the contrast transfer function. For the 60 kV TEM image at a dose of 27 e−/Å2 (Fig. 3e) with the best R value (0.07 in Fig. 3j) obtained with a defocus of −2.8 μm without using an objective aperture, the resolution was estimated as 3.69 nm, which is worse than that (1.83 nm in Fig. 3l) of the ptychographic phase (Fig. 3c) under the similar dose condition of 26 e−/Å2 with almost a two-fold increase in the R value (0.19 in Fig. 3h).
Contrast enhancement at low voltage
As we have observed, both contrast and resolution were both strongly influenced by the accelerating voltage and the electron dose. Figure 4a–d shows comparisons between the normalised 2D ptychographic phases and TEM images taken at 60 kV and 300 kV accelerating voltages. From the same sample, the data at 60 kV showed a value of R approximately three times higher than that at 300 kV for both ptychography and TEM (Fig. 4e–h) consistent with increased contrast from weakly scattering objects at lower voltages66. Importantly R for the ptychographic reconstruction increased from 0.04 to 0.11, which was sufficient to distinguish the frequency peaks of the DNA strands from backgrounds at 60 kV, whereas for TEM data, it increased from 0.02 to 0.07, which did not meet the requirement for separation.
Dose-dependent reconstructions
To study the dose-dependent ptychographic contrast of DNA, we reduced the total electron dose by reducing the overlap ratios (see Supplementary Note 8: Dose Reduction). As illustrated in Fig. 3a–c, the doses were 88 e−/Å2, 45 e−/Å2 and 26 e−/Å2 for each tilt angle, for overlap ratios of 83%, 76 and 66%. The resolution of 2D ptychographic reconstruction calculated by Fourier ring correlation (FRC) is shown in Fig. 3l (see details in Supplementary Note 7: FSC and FRC). Resolutions of 1.65 nm and 1.83 nm are calculated from two independent reconstructions with a dose of 45 e−/Å2 and 26 e−/Å2, respectively (Fig. 3l). Similarly, the contrast ratio R of the DNA strands was reduced from 0.24 (88 e−/Å2) to 0.19 (45 e−/Å2) and 0.15 (26 e−/Å2 as shown in Fig. 3f–h). By comparison, a series of TEM images with different doses (to over 250 e−/Å2) were also collected (Supplementary Fig. 8a). Using the same normalisation the contrast ratio (R) was maintained at around 0.065, when the dose was greater than 60 e−/Å2 (Supplementary Fig. 8c), suggesting that simply increasing the dose above this limit does not enhance the contrast of the DNA against the background of the amorphous carbon film in TEM imaging.
For 3D reconstruction, the total dose of the tilt series was reduced from 2024 e−/Å2 (Fig. 1b) to 1035 e−/Å2 (Supplementary Fig. 7a) and to 598 e−/Å2 (Supplementary Fig. 7d) using the dose-reduced 2D ptychographic phases (as shown in Fig. 3a–c). With reduced total dose (for details see Supplementary Note 8: Dose Reduction), the 3D structure of the DNA origami was still successfully reconstructed by ptychographic tomography. In a histogram analysis (shown in Supplementary Fig. 7c–f), the peaks were still separated although broadened. The 3D resolution calculated from a FSC was lowered from 2.08 nm at a dose of 1035 e−/Å2 (Supplementary Fig. 7c) to 3.74 nm at a dose of 598 e−/Å2 (Supplementary Fig. 7f) corresponding to the resolution degradation in the 2D phases (Fig. 3l). To further improve the quality of the reconstructed 2D phase data and at reduced dose, the use of a newly developed ultrafast detector53,54,67,68,69 shows promise. and recording data under cryogenic conditions will further limit radiation damage, as has been demonstrated by by Zhou et al.56.
Discussion
To develop structural DNA nanotechnology, 3D TEM imaging is critical for precisely designing and characterising the programable inter-particle linkers, particularly at low electron dose. Generally, the 3D reconstruction methods that have been applied to DNA origami are either conventional tomography or SPA70 as summarised in Table 1. SPA is based on the assumption that the samples are homogeneous with many identical copies of the same structure. For example, the 3D reconstruction work by Shih et al.71 reported images of unstained DNA origami octahedral particles at 3.2 nm resolution, and assumed that many identical particles folded into the same structure23,72. However, DNA origami nanostructures are purposely designed and fabricated with multiple degrees of freedom and complex 2D/3D motion flexibility73,74 to diverse functionality and hence, SPA is unsuitable for reconstructing many different conformations. In contrast, TEM tomography is often chosen for 3D reconstruction of heterogeneous samples, as shown in Table 1. For example, Zhang et al.24 applied TEM tomography to study the structural dynamics of stained DNA-gold nanoparticle conjugates and achieved a 3D reconstruction with a resolution of 1.4 ~ 2.3 nm using a total dose of about 1500 ~ 2500 e−/Å2. However, the major problem of this approach is that the contrast of the DNA per se was not high enough to be distinguished from the support unless it was stained. This is consistent with our TEM observations of unstained DNA strands (Fig. 3d, e, Supplementary Fig. 4). However, taking advantage of the phase sensitivity of ptychography, we were able to achieve high contrast 3D reconstructions of unstained DNA origami at a resolution of 2.08 nm.
In general contrast and SNR in a tomogram of a biological sample are limited by the tolerance to total radiation dose during the entire acquisition of the entire tilt series. It is therefore worthwhile to compare the tomographic workflows that are used for conventional TEM with those for ptychography (shown respectively in Fig. 5a, b). For conventional TEM-based tomography, accurate defocus control is essential for high resolution image acquisition during tilting, as defoci need to be approximately constant for all tilt angles. However, in practice, the defocus value must be always tracked and adjusted before each image acquisition (Fig. 5a). This procedure can be time-consuming, but also adds electron dose that does not contribute to the final image dataset. In contrast, ptychography has the advantage of post-acquisition focusing48, and hence the defocus values can be compensated during the reconstruction after data collection (Fig. 5b). The defocus values for the current work were found to vary between −45 μm and −34 μm (Fig. 5c, Supplementary Table 1). Details of the post-acquisition focusing process are described in Supplementary Note 9: Post-focusing. As a result, defocus adjustment can be omitted during acquisition, saving exposure time and the dose budget.
As an alternative ptychographic retrival in STEM, phase-contrast methods including through focal series28 and tilt series22,75 have been used to increase resolution and improve image interpretation in TEM. Atomic resolution exitwave tomography has been theoretically demonstrated for an amorphous structure76. However, most of the experimental focus series exitwave reconstruction algorithms require small defocus changes relative to the dimensions of the sample77 in order to achieve high resolution78. To restore low spatial frequencies without compromising high spatial frequency transfer, the inclusion of a second focal series data set with a larger focal step has been suggested28. However, the large focal differences in the micrometre range required may lead to variations in magnification, image rotation, and possibly other distortions. In addition, the extent to which radiation damage may limit these alternative approaches remains to be explored experimentally, and the difficulties of image alignment at low dose may introduce further limitations.
In addition to computational methods, a physical phase plate such as Zernike79,80,81 and Volta82,83 that can be positioned at the back focal plane of objective lens to introduce a phase shift between the scattered and unscattered electron wave, leading to in-focus phase contrast without compromising low-resolution transfer. Tomography using phase plates is commonly used for the studies of biological objects in cryogenic TEM81,84. However, organic and inorganic hybrid structures such as the sample used here have not been studied. Furhermore these devices can suffer from signal attenuation at high frequencies, inconsistent fabrication, instability and a short usable life-span due to electrostatic charging85,86.
Recently, in STEM a pre-specimen phase plate was introduced in the probe-forming lens to acquire a 4D-STEM dataset with a focused probe, called MIDI-STEM87. This was further combined with non-iterative ptychography, giving enhancement of the contrast transfer at low spatial frequencies for 2D imaging88. Potentially this technique could further provide a 3D phase reconstruction when used in conjunction with tomography. Using MIDI-STEM also allows simultaneous annular dark field (ADF) imaging89, but it generally requires a fast detector. If raw data volumes in a dense representation are considered then there is also a substantial increase in data volume with field of view for this technique. However, we note that there have been reports of advanced data processing strategies to mitigate this68,90. In contrast, defocus-probe ptychography can be preformed with relatively simple detectors and requires less raw data volume for an object of the same size. Furthermore, removing the requirement to insert a condenser phase plate before each acquisition reduces the experimental complexity, particularly for low-dose experiments.
In summary, by combining electron ptychography and tomography, we have demonstrated 3D reconstruction of unstained DNA origami strands and gold nanoparticles with core-shell structures; a case of imaging biological and non-biological hybrid materials. In contrast to conventional TEM tomography, ptychography based tomography (EPty-Tomo) shows advantages of both high contrast and resolution at a low dose and can simultaneously visualise both weakly scattering materials (beam-sensitive biological materials) and strong scattering (inorganic, metal) materials. The post-focusing capability of ptychography simplifies the tomographic workflow, consequently reducing the total dose budget and radiation damage. With future developments of ultrafast detectors and improved cryogenic techniques, ptychographic tomography has great potential as an alternative to conventional electron cryo-tomography for high-resolution, large-volume visualisation of biological/non-biological hybrid structured materials. In turn this will assist the efficient development and refinement of fabrication processes and functional design.
Methods
Samples
DNA origami with a tetrahedral structure with gold nanoparticles inlayed was prepared using one-step self-assembly method. DNA origami was unstained and suspended on 50-mesh copper grid covered with an ultrathin carbon film in room temperature and air dried. Detailed information of sample preparation is described in Supplementary Note 1: Sample Preparation.
Experimental measurements
Data for ptychographic tomography was acquired using a FEI Titan G2 Cubed with two aberration correctors at an accelerated voltage of 60 kV. A beam with a convergence angle of 1.5 mrad and defocus of −40 μm was formed giving a diameter of 120 nm at the sample. Diffraction patterns were recorded using Gatan Orius SC200 camera with 2048 × 2048 pixels for a dwell time of 0.2 s. At each tilt angle, the electron beam was scanned in a 10 × 10 array over the sample with a scanning step of 20 nm to fulfil the overlap ratio required by ptychography. The sample was tilted about two mutually perpendicular axes from −49.99 to 53.94 degree and from −53.42 to 46.40 degree, respectively. A Fischione Model 2040 tomographic holder was used which has a maximum tilt angle of +/− 70° degree. However, for higher tilting angles, the sample was blocked by the copper grid. The tilt angle increment was approximate 10 degree. Defocus values as a function of the tilt angles are listed in Supplementary Table 1 and typical diffraction patterns and 2D ptychographic phases are shown in Supplementary Fig. 1 and Supplementary Fig. 2.
Ptychography and tomography reconstructions
The two-dimensional sample complex function at each tilt angle was reconstructed using the ePIE algorithm33. Detailed information of the ePIE algorithm used is described in Supplementary Note 3: 2D Ptychographic Reconstruction.
In the ptychographic reconstruction, amplitude of initial object guess is 1 (i.e. constant array), and initial phase is initialised with random low frequency information (from 0 to 0.035 nm−1). Initial probe function is calculated from the measured values of the convergence angle and defocus.
Diffraction patterns collected at each angle under different defocus conditions were processed by threshold and reconstructed using ePIE for 100 iterations with α = 0.5. Defocus values at each tilt angle are listed in Supplementary Table 1. The phases of the reconstructed complex functions (Supplementary Fig. 2) were then used as inputs for the subsequent tomographic reconstruction.
After ptychographic reconstructions, two datasets of the 2D ptychographic phase projections were generated from two tilt series as inputs for the tomographic reconstruction procedure. Tilt axes and image shifts were aligned manually using IMOD91 and tilt angles were subsequently calibrated (Supplementary Table 1). GENeralized Fourier Iterative Reconstruction (GENFIRE) algorithm58 was used for tomographyic reconstruction and the resultant 3D reconstructions is shown in Fig. 1b, Fig. 2, Supplementary Fig. 3a, Supplementary Fig. 7. Detailed information of tomographic reconstruction is described in Supplementary Note 4: 3D Tomographic Reconstruction.
Reporting summary
Further information on research design is available in the Nature Research Reporting Summary linked to this article.
Data availability
The raw data (tilt-series diffraction datasets) in this study have been deposited in the Zenodo database (https://doi.org/10.5281/zenodo.6819331).
Code availability
Distributions of ePIE code are subject to an agreed licence agreement with Phase Focus Ltd. and the aurhors of this paper are not permitted to distribute the ePIE code used under the terms of that agreement. The IMOD code is available as open source under a General Public License (GPL) version v2.0 from the authors (https://bio3d.colorado.edu/imod/). The GENFIRE code is available as open source under a GNU General Public licence v3.0 (https://github.com/genfire-em/GENFIRE-Python).
References
Seeman, N. C. Nucleic-acid junctions and lattices. J. Theor. Biol. 99, 237–247 (1982).
Rothemund, P. W. K. Folding DNA to create nanoscale shapes and patterns. Nature 440, 297–302 (2006).
Jiang, D. et al. DNA origami nanostructures can exhibit preferential renal uptake and alleviate acute kidney injury. Nat. Biomed. Eng. 2, 865–877 (2018).
Jiang, Q., Liu, S., Liu, J., Wang, Z. G. & Ding, B. Rationally designed DNA‐origami nanomaterials for drug delivery in vivo. Adv. Mater. 31, 1804785 (2019).
Palazzolo, S. et al. An effective multi-stage liposomal DNA origami nanosystem for in vivo cancer therapy. Cancers 11, 1997 (2019).
Liu, H., Wang, J., Song, S., Fan, C. & Gothelf, K. V. A DNA-based system for selecting and displaying the combined result of two input variables. Nat. Commun. 6, 1–7 (2015).
Fu, J., Liu, M., Liu, Y., Woodbury, N. W. & Yan, H. Interenzyme substrate diffusion for an enzyme cascade organized on spatially addressable DNA nanostructures. J. Am. Chem. Soc. 134, 5516–5519 (2012).
Masubuchi, T. et al. Construction of integrated gene logic-chip. Nat. Nanotechnol. 13, 933–940 (2018).
Grome, M. W., Zhang, Z., Pincet, F. & Lin, C. Vesicle tubulation with self‐assembling DNA nanosprings. Angew. Chem. Int. Ed. 57, 5330–5334 (2018).
Surwade, S. P., Zhao, S. & Liu, H. Molecular lithography through DNA-mediated etching and masking of SiO2. J. Am. Chem. Soc. 133, 11868–11871 (2011).
Diagne, C. T., Brun, C., Gasparutto, D., Baillin, X. & Tiron, R. DNA origami mask for sub-ten-nanometer lithography. ACS Nano. 10, 6458–6463 (2016).
Nickels, P. C. et al. Molecular force spectroscopy with a DNA origami–based nanoscopic force clamp. Science 354, 305–307 (2016).
Mirkin, C. A., Letsinger, R. L., Mucic, R. C. & Storhoff, J. J. A DNA-based method for rationally assembling nanoparticles into macroscopic materials. Nature 382, 607–609 (1996).
Alivisatos, A. P. et al. Organization of ‘nanocrystal molecules’ using DNA. Nature 382, 609–611 (1996).
Tian, Y. et al. Lattice engineering through nanoparticle-DNA frameworks. Nat. Mater. 15, 654–661 (2016).
Zhang, T. et al. 3D DNA origami crystals. Adv. Mater. 30, 1–6 (2018).
Ofir, Y., Samanta, B. & Rotello, V. M. Polymer and biopolymer mediated self-assembly of gold nanoparticles. Chem. Soc. Rev. 37, 1814–1825 (2008).
Nie, Z., Petukhova, A. & Kumacheva, E. Properties and emerging applications of self-assembled structures made from inorganic nanoparticles. Nat. Nanotechnol. 5, 15–25 (2010).
Kuzyk, A. et al. DNA-based self-assembly of chiral plasmonic nanostructures with tailored optical response. Nature 483, 311–314 (2012).
Frank, J. Three-Dimensional Electron Microscopy of Macromolecular Assemblies. (Oxford University Press, New York, 1996).
Koster, A. J. et al. Perspectives of molecular and cellular electron tomography. J. Struct. Biol. 120, 276–308 (1997).
Midgley, P. A. & Dunin-Borkowski, R. E. Electron tomography and holography in materials science. Nat. Mater. 8, 271–280 (2009).
Bai, X., Martin, T. G., Scheres, S. H. & Dietz, H. Cryo-EM structure of a 3D DNA-origami object. Proc. Natl Acad. Sci. 109, 20012–20017 (2012).
Zhang, L. et al. Three-dimensional structural dynamics and fluctuations of DNA-nanogold conjugates by individual-particle electron tomography. Nat. Commun. 7, 1–10 (2016).
Briegel, A., Pilhofer, M., Mastronarde, D. N. & Jensen, G. J. The challenge of determining handedness in electron tomography and the use of DNA origami gold nanoparticle helices as molecular standards. J. Struct. Biol. 183, 95–98 (2013).
Lei, D. et al. Three-dimensional structural dynamics of DNA origami Bennett linkages using individual-particle electron tomography. Nat. Commun. 9, 1–8 (2018).
Oliveira, S. C., Corduneanu, O. & Oliveira-Brett, A. M. In situ evaluation of heavy metal-DNA interactions using an electrochemical DNA biosensor. Bioelectrochemistry 72, 53–58 (2008).
Haigh, S., Jiang, B., Alloyeau, D., Kisielowski, C. & Kirkland, A. Recording low and high spatial frequencies in exit wave reconstructions. Ultramicroscopy 133, 26–34 (2013).
Hegerl, R. & Hoppe, W. Dynamische theorie der kristallstrukturanalyse durch elektronenbeugung im inhomogenen primärstrahlwellenfeld. Ber. der Bunsenges. f.ür. physikalische Chem. 74, 1148–1154 (1970).
Miao, J. W., Charalambous, P., Kirz, J. & Sayre, D. Extending the methodology of X-ray crystallography to allow imaging of micrometre-sized non-crystalline specimens. Nature 400, 342–344 (1999).
Rodenburg, J. M. Ptychography and related diffractive imaging methods. Adv. Imaging Electron Phys. 150, 87–184 (2008).
Rodenburg, J. M. et al. Hard-x-ray lensless imaging of extended objects. Phys. Rev. Lett. 98, 034801 (2007).
Maiden, A. M. & Rodenburg, J. M. An improved ptychographical phase retrieval algorithm for diffractive imaging. Ultramicroscopy 109, 1256–1262 (2009).
Thibault, P., Dierolf, M., Bunk, O., Menzel, A. & Pfeiffer, F. Probe retrieval in ptychographic coherent diffractive imaging. Ultramicroscopy 109, 338–343 (2009).
Rodenburg, J. M., Hurst, A. C. & Cullis, A. G. Transmission microscopy without lenses for objects of unlimited size. Ultramicroscopy 107, 227–231 (2007).
Dierolf, M. et al. Ptychographic X-ray computed tomography at the nanoscale. Nature 467, 436–439 (2010).
Maiden, A. M., Humphry, M. J. & Rodenburg, J. M. Ptychographic transmission microscopy in three dimensions using a multi-slice approach. J. Optical Soc. Am. A-Opt. Image Sci. Vis. 29, 1606–1614 (2012).
Trtik, P., Diaz, A., Guizar-Sicairos, M., Menzel, A. & Bunk, O. Density mapping of hardened cement paste using ptychographic X-ray computed tomography. Cem. Concr. Compos. 36, 71–77 (2013).
Holler, M. et al. X-ray ptychographic computed tomography at 16 nm isotropic 3D resolution. Sci. Rep. 4, 1–5 (2014).
Suzuki, A. et al. High-resolution multislice X-ray ptychography of extended thick objects. Phys. Rev. Lett. 112, 053903 (2014).
Rodenburg, J. M., Mccallum, B. C. & Nellist, P. D. Experimental tests on double-resolution coherent imaging via stem. Ultramicroscopy 48, 304–314 (1993).
Nellist, P. D., McCallum, B. C. & Rodenburg, J. M. Resolution beyond the ‘information limit’ in transmission electron microscopy. Nature 374, 630–632 (1995).
Pennycook, T. J. et al. Efficient phase contrast imaging in STEM using a pixelated detector. Part I: Experimental demonstration at atomic resolution. Ultramicroscopy 151, 160–167 (2015).
Yang, H., Pennycook, T. J. & Nellist, P. D. Efficient phase contrast imaging in STEM using a pixelated detector. Part II: Optimisation of imaging conditions. Ultramicroscopy 151, 232–239 (2015).
Jiang, Y. et al. Electron ptychography of 2D materials to deep sub-ångström resolution. Nature 559, 343–349 (2018).
Yang, H. et al. Simultaneous atomic-resolution electron ptychography and Z-contrast imaging of light and heavy elements in complex nanostructures. Nat. Commun. 7, 12532 (2016).
Wang, P., Zhang, F., Gao, S., Zhang, M. & Kirkland, A. I. Electron ptychographic diffractive imaging of boron atoms in LaB6 crystals. Sci. Rep. 7, 1–8 (2017).
Gao, S. et al. Electron ptychographic microscopy for three-dimensional imaging. Nat. Commun. 8, 1–8 (2017).
Song, B. et al. Hollow electron ptychographic diffractive imaging. Phys. Rev. Lett. 121, 146101 (2018).
Pelz, P. M., Qiu, W. X., Bucker, R., Kassier, G. & Miller, R. J. D. Low-dose cryo electron ptychography via non-convex Bayesian optimization. Sci. Rep. 7, 9883 (2017).
Song, J. et al. Atomic resolution defocused electron ptychography at low dose with a fast, direct electron detector. Sci. Rep. 9, 1–8 (2019).
Pennycook, T. J., Martinez, G. T., Nellist, P. D. & Meyer, J. C. High dose efficiency atomic resolution imaging via electron ptychography. Ultramicroscopy 196, 131–135 (2019).
Tate, M. W. et al. High dynamic range pixel array detector for scanning transmission electron microscopy. Microsc. Microanalysis. 22, 237 (2016).
Mir, J. A. et al. Characterisation of the Medipix3 detector for 60 and 80keV electrons. Ultramicroscopy 182, 44–53 (2017).
Chang, D. J. et al. Ptychographic atomic electron tomography: Towards three-dimensional imaging of individual light atoms in materials. Phys. Rev. B. 102, 174101 (2020).
Zhou, L. et al. Low-dose phase retrieval of biological specimens using cryo-electron ptychography. Nat. Commun. 11, 1–9 (2020).
Wolf, S. G., Houben, L. & Elbaum, M. Cryo-scanning transmission electron tomography of vitrified cells. Nat. Methods 11, 423–428 (2014).
Pryor, A. et al. GENFIRE: A generalized Fourier iterative reconstruction algorithm for high-resolution 3D imaging. Sci. Rep. 7, 1–12 (2017).
Cutler, J. I., Auyeung, E. & Mirkin, C. A. Spherical nucleic acids. J. Am. Chem. Soc. 134, 1376–1391 (2012).
Narayan, S. P. et al. The sequence‐specific cellular uptake of spherical nucleic acid nanoparticle conjugates. Small 11, 4173–4182 (2015).
Maiden, A., Sarahan, M., Stagg, M., Schramm, S. & Humphry, M. Quantitative electron phase imaging with high sensitivity and an unlimited field of view. Sci. Rep. 5, 1–8 (2015).
Hüe, F., Rodenburg, J., Maiden, A., Sweeney, F. & Midgley, P. Wave-front phase retrieval in transmission electron microscopy via ptychography. Phys. Rev. B 82, 121415 (2010).
Van Heel, M. & Schatz, M. Fourier shell correlation threshold criteria. J. Struct. Biol. 151, 250–262 (2005).
Bals, S., Van Aert, S. & Van Tendeloo, G. High resolution electron tomography. Curr. Opin. Solid State Mater. Sci. 17, 107–114 (2013).
Maiden, A. M., Humphry, M. J., Zhang, F. & Rodenburg, J. M. Superresolution imaging via ptychography. J. Optical Soc. Am. A. 28, 604–612 (2011).
Vancová, M. How to observe small biological objects in low voltage electron microscope. Microsc. Microanalysis. 13, 248–249 (2007).
Ercius, P. et al. The 4D camera–An 87 kHz frame-rate detector for counted 4D-STEM experiments. Microsc. Microanalysis. 26, 1896–1897 (2020).
Jannis, D. et al. Event driven 4D STEM acquisition with a Timepix3 detector: microsecond dwell time and faster scans for high precision and low dose applications. Ultramicroscopy 233, 113423 (2022).
Philipp, H. T. et al. Very-high dynamic range, 10,000 frames/second pixel array detector for electron microscopy. Microsc. Microanalysis. 28, 425–440 (2022).
Zhou, Z. H. Towards atomic resolution structural determination by single-particle cryo-electron microscopy. Curr. Opin. Struct. Biol. 18, 218–228 (2008).
Shih, W. M., Quispe, J. D. & Joyce, G. F. A 1.7-kilobase single-stranded DNA that folds into a nanoscale octahedron. Nature 427, 618–621 (2004).
He, Y. et al. On the chirality of self‐assembled DNA octahedra. Angew. Chem. Int. Ed. 49, 748–751 (2010).
Marras, A. E., Zhou, L., Su, H. J. & Castro, C. E. Programmable motion of DNA origami mechanisms. Proc. Natl Acad. Sci. 112, 713–718 (2015).
Castro, C. E., Su, H. J., Marras, A. E., Zhou, L. & Johnson, J. Mechanical design of DNA nanostructures. Nanoscale 7, 5913–5921 (2015).
Haigh, S. J., Sawada, H. & Kirkland, A. I. Atomic structure imaging beyond conventional resolution limits in the transmission electron microscope. Phys. Rev. Lett. 103, 126101 (2009).
Borisenko, K. B. et al. Toward electron exit wave tomography of amorphous materials at atomic resolution. J. Alloy. Compd. 536, S94–S98 (2012).
Whittaker, M. L. et al. Dynamic clay microstructures emerge via ion complexation waves. Preprint at https://arxiv.org/abs/2012.09295 (2020).
Ren, D., Ophus, C., Chen, M. & Waller, L. A multiple scattering algorithm for three dimensional phase contrast atomic electron tomography. Ultramicroscopy 208, 112860 (2020).
Danev, R., Kanamaru, S., Marko, M. & Nagayama, K. Zernike phase contrast cryo-electron tomography. J. Struct. Biol. 171, 174–181 (2010).
Dai, W. et al. Visualizing virus assembly intermediates inside marine cyanobacteria. Nature 502, 707–710 (2013).
Dai, W. et al. Zernike phase-contrast electron cryotomography applied to marine cyanobacteria infected with cyanophages. Nat. Protoc. 9, 2630–2642 (2014).
Danev, R., Buijsse, B., Khoshouei, M., Plitzko, J. M. & Baumeister, W. Volta potential phase plate for in-focus phase contrast transmission electron microscopy. Proc. Natl Acad. Sci. 111, 15635–15640 (2014).
Khoshouei, M., Radjainia, M., Baumeister, W. & Danev, R. Cryo-EM structure of haemoglobin at 3.2 Å determined with the Volta phase plate. Nat. Commun. 8, 1–6 (2017).
Fukuda, Y., Laugks, U., Lučić, V., Baumeister, W. & Danev, R. Electron cryotomography of vitrified cells with a Volta phase plate. J. Struct. Biol. 190, 143–154 (2015).
Danev, R., Glaeser, R. M. & Nagayama, K. Practical factors affecting the performance of a thin-film phase plate for transmission electron microscopy. Ultramicroscopy 109, 312–325 (2009).
Danev, R. & Baumeister, W. Expanding the boundaries of cryo-EM with phase plates. Curr. Opin. Struct. Biol. 46, 87–94 (2017).
Ophus, C. et al. Efficient linear phase contrast in scanning transmission electron microscopy with matched illumination and detector interferometry. Nat. Commun. 7, 1–7 (2016).
Yang, H., Ercius, P., Nellist, P. D. & Ophus, C. Enhanced phase contrast transfer using ptychography combined with a pre-specimen phase plate in a scanning transmission electron microscope. Ultramicroscopy 171, 117–125 (2016).
Pennycook, S. & Jesson, D. High-resolution incoherent imaging of crystals. Phys. Rev. Lett. 64, 938 (1990).
Pelz, P. M., Johnson, I., Ophus, C., Ercius, P. & Scott, M. C. Real-Time interactive 4D-STEM phase-contrast imaging from electron event representation data: less computation with the right representation. IEEE Signal Process. Mag. 39, 25–31 (2021).
Kremer, J. R., Mastronarde, D. N. & McIntosh, J. R. Computer visualization of three-dimensional image data using IMOD. J. Struct. Biol. 116, 71–76 (1996).
Danev, R., Yanagisawa, H. & Kikkawa, M. Cryo-electron microscopy methodology: current aspects and future directions. Trends Biochemical Sci. 44, 837–848 (2019).
Tian, Y. et al. Prescribed nanoparticle cluster architectures and low-dimensional arrays built using octahedral DNA origami frames. Nat. Nanotechnol. 10, 637–644 (2015).
Acknowledgements
The authors would like to acknowledge funding from the National Natural Science Foundation of China (11874199, 21991134, 21934007, 92056117), the International Cooperation and Exchange Program by NSFC (11911530174, 92056117), University of Warwick Research Development Fund (RDF) 2021–22 Science Development Award, Natural Science Foundation of Jiangsu Province (BK20210187) and China Postdoctoral Science Fundation (No. 2022M711564).
Author information
Authors and Affiliations
Contributions
PW conceived the project. Z.Y.D. and S.G. carried out the 3D ptychographical data acquisition and algorithm development. Z.Y.D. carried out the 3D reconstruction and analysis with S.G., L.Q.Z. and X.D.P. S.G. and C.H. carried out the focal-series reconstruction. W.N.F., X.G.L. and C.H.F. prepared the DNA origami samples. Z.Y.D., S.G., W.N.F., L.Q.Z., X.D.P., X.Q.P., C.H.F. and P.W. discussed the data analysis. Z.Y.D., S.G., A.I.K. and P.W. wrote and edited the manuscript. All authors discussed the results and commented on the manuscript.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Peer review
Peer review information
Nature Communications thanks Jianwei (John) Miao and the other, anonymous, reviewer(s) for their contribution to the peer review of this work.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Ding, Z., Gao, S., Fang, W. et al. Three-dimensional electron ptychography of organic–inorganic hybrid nanostructures. Nat Commun 13, 4787 (2022). https://doi.org/10.1038/s41467-022-32548-x
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41467-022-32548-x
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.