Abstract
There are only few data concerning persistence of neutralizing antibodies (NAbs) among SARS-CoV-2-infected healthcare workers (HCW). These individuals are particularly exposed to SARS-CoV-2 infection and at potential risk of reinfection. We followed 26 HCW with mild COVID-19 three weeks (D21), two months (M2) and three months (M3) after the onset of symptoms. All the HCW had anti-receptor binding domain (RBD) IgA at D21, decreasing to 38.5% at M3 (p < 0.0001). Concomitantly a significant decrease in NAb titers was observed between D21 and M2 (p = 0.03) and between D21 and M3 (p < 0.0001). Here, we report that SARS-CoV-2 can elicit a NAb response correlated with anti-RBD antibody levels. However, this neutralizing activity declines, and may even be lost, in association with a decrease in systemic IgA antibody levels, from two months after disease onset. This short-lasting humoral protection supports strong recommendations to maintain infection prevention and control measures in HCW, and suggests that periodic boosts of SARS-CoV-2 vaccination may be required.
Similar content being viewed by others
Introduction
A novel human coronavirus, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causal agent of coronavirus disease 19 (COVID-19), emerged in late 2019 and rapidly spread worldwide, causing a global pandemic1. SARS-CoV-2 infection results in a wide range of clinical manifestations, from asymptomatic or mild forms to severe respiratory failure2. Healthcare workers (HCW) are particularly exposed to SARS-CoV-2 infection during the management of patients with COVID-19, and several recommendations have been made to protect them3,4,5. Moreover, infected HCW could serve as a source of hospital-acquired COVID-19. It is therefore important to assess the durability of immune protection after SARS-CoV-2 infection in this population.
Serological diagnosis is becoming increasingly important in attempts to understand the extent to which COVID-19 is spreading in the community and to identify individuals who are immunized and potentially “protected” against re-infection. Most serological studies to date have focused on hospitalized patients, and were therefore unable to evaluate the serologic responses in individuals with mild or subclinical infection, including HCW in particular6,7,8,9,10. The few studies focusing on this particular population have investigated only seroconversion rates, without considering the persistence of the SARS-CoV-2 antibodies induced over time11,12,13. Recent studies have shown that anti-SARS-CoV-2 antibody levels decrease from 8 weeks after the onset of symptoms and that serum samples from 33% of SARS-CoV-2-infected patients display no neutralizing activity, even 39 days after symptom onset10,14. Moreover, the protection correlates of immunity to SARS-CoV-2 infection are not well defined, and little is known about the persistence of antibodies over time. There is some evidence that immune protection against other human coronaviruses (HCoV) is not long-lasting15, but there is also evidence that antibodies against the severe acute respiratory syndrome coronavirus (SARS-CoV)16,17 persist for years and display potent neutralizing activity even in the absence of detectable serum immunoglobulin G (IgG) directed against SARS-CoV nucleocapsid protein (N)18. Neutralizing antibodies (NAbs) prevent viral infection mostly by blocking the early step of infection, viral entry, especially in interfering with virions binding to their receptor. NAbs can be evaluated in vitro in neutralization tests, and their presence is often correlated with protective immunity19.
There is now a need to correlate the detection of different isotypes of antibodies produced in response to SARS-CoV-2 infection with their neutralizing activity, to assess the development of protective antibody responses and to study their duration.
Here, we aimed at studying the longitudinal profile of IgG, immunoglobulin A (IgA) and M (IgM) and the neutralizing activity of sera against SARS-CoV-2, for 26 HCW recovering from mild forms of reverse transcription PCR (RT-PCR)-confirmed SARS-CoV-2 infection.
In this work we show that all the studied HCW displayed seroconversion and a NAb response against SARS-CoV-2 from 21 days after symptom onset, which was correlated with the levels of anti-RBD antibodies. However, this neutralizing activity appears to be transient with a decline, or even a loss, of the NAb titers associated with a decrease in systemic IgA antibody levels from 2 months after disease onset.
Results
Patient characteristics and serum collection
From 28 January to 21 March 2020, 26 HCW from Pitié-Salpêtrière University Hospital were enrolled in this study. Their characteristics are presented in Table 1. The median [interquartile (IQR)] age of the participants was 46 [38–53] years, 11 (42.3%) were men, and most (69.2%) were physicians. The hypothetical exposure to SARS-CoV-2 is thought to have occurred during the management of COVID-19 patients in 14 (53.8%) HCW, 6 (23.1%) of whom performed high-risk aerosol-generating procedures (nasopharyngeal, tracheal and pulmonary sampling, endotracheal intubation, use of high-flow nasal cannula, oxygen masks or non-invasive ventilation). However, 12 HCW (46.2%) were exposed to the virus during professional activities unrelated to patient care.
All the HCW had symptoms consistent with COVID-19 (Table 1). The median duration of symptoms was 2 [1–3] weeks and 5 (19.2%) HCW developed new symptoms after a period of recovery. The new symptoms were principally dysosmia and transient headache, developing a median of 3.5 [2–4] months after the COVID-19 episode.
The median time between the onset of symptoms and positive RT-PCR results was 2 [1–3] days, and the median time from onset of symptoms to blood sampling was 17 [14–23.25] days for the D21 time point, 59 [57–61] days for M2, and 97 [91–100] for M3.
IgG, IgA, and IgM profile
At the first time point (D21), all HCW had detectable IgG antibodies against SARS-CoV-2 N protein, IgA antibodies against SARS-CoV-2 receptor-binding domain (RBD), and IgA antibodies against SARS-CoV-2 spike protein (S). In addition, 92.3% (24/26) had detectable anti-RBD IgG antibodies and 80.8% (21/26) had detectable anti-S IgG antibodies. Only 42.3% (11/26) had detectable anti-N/anti-S IgM antibodies. At M2, all HCW remained positive for anti-N IgG antibodies. The rates of seropositivity for anti-S IgG, anti-RBD IgG, and anti-N/anti-S IgM antibodies were 94.1% (16/17), 100% (17/17), and 64.7% (11/17), respectively. Meanwhile, the anti-S IgA seropositivity rate declined to 88.2% (15/17) and that for anti-RBD IgA fell to 47% (8/17). At M3, the seropositivity rate for anti-N IgG had decreased slightly, to 96.2% (25/26). The proportion of anti-S IgG antibodies was 96.2% (25/26), and the proportion of anti-S IgA antibodies continue to decline, reaching 80.8% by this time point (21/26). In parallel, the seropositivity rate for anti-RBD IgG antibodies declined to 92.3% (24/26) and that for anti-RBD IgA fell to 38.5% (10/26). We were able to detect anti-N/anti-S IgM antibodies in 15/26 HCW (57.7%).
We then compared the changes in the levels of these antibodies over time, to assess the intensity of the immune response to SARS-CoV-2 (Fig. 1). Anti-S and anti-RBD IgA antibody levels decreased significantly between D21 and M2 (p = 0.007 and p < 0.001, respectively) and between D21 and M3 (p < 0.001 and p < 0.001, respectively). Anti-S and anti-RBD IgG antibody levels did not change significantly between D21 and M3, despite a slight increase in antibody levels at M2 (p < 0.001 and p = 0.04). Anti-N IgG levels were stable at M2, but decreased significantly between D21 and M3 (p < 0.001). Finally, no change in anti-N/anti-S IgM levels were observed between D21 and M2 or M3 (p = 0.18 and p = 0.53, respectively). Ten serum samples from patients with other respiratory infections caused by HCoV (2 HCoV-HKU1, 3 HCoV-OC43, 3 HCoV-NL63, and 2 HCoV-229E), obtained between 11 and 54 days after RT-PCR diagnosis, were also tested in each immunoassay, to evaluate the specificity of these tests. None of these samples gave positive results with the SARS-CoV-2-specific antibody tests used, demonstrating an absence of cross-reactivity.
Changes in Nab titers over time
We analyzed the neutralizing activity of serum samples from the 26 HCW in a virus neutralization test (VNT). At D21, all sera (100%) harbored NAbs with a neutralizing titer ≥1:5, the median neutralizing titer being 1:20 [1:10–1:40] (Fig. 2). At M2, serum samples from 88.2% (15/17) of the HCW were still neutralizing, with a median neutralizing titer of 1:20 [1:5–1:20]. By M3, serum samples from another two HCW had lost their neutralizing activity; serum samples from 84.6% (22/26) of the HCW remained neutralizing, with a median titer of 1:10 [1:5–1:20]. NAb titers decreased significantly between D21 and M2 (p = 0.03) and between D21 and M3 (p < 0.001). The four HCW whose sera lost their neutralizing capacity had no detectable anti-RBD IgA antibodies at M3, whereas such antibodies were detected when their sera were neutralizing at D21.
We also tested the same 10 HCoV serum samples (2 HCoV-HKU1, 3 HCoV-OC43, 3 HCoV-NL63, and 2 HCoV-229E) to assess cross-neutralization capacities between HCoV and SARS-CoV-2. None of these serum samples displayed SARS-CoV-2-neutralizing capacity.
Association of NAb titer with IgG, IgA, and IgM antibody profile
We first evaluated the relative contributions of each antibody isotype and/or epitopes to the neutralizing capacity of the sera at the various time points. We found that the antibodies most strongly associated with NAb titers were anti-RBD IgG and IgA antibodies (Spearman’s rank correlation coefficient (rs,): 0.73 [confidence interval 95%, CI 95%: 0.58–0.82]; p < 0.0001 and rs: 0.64 [CI 95%: 0.47–0.77]; p < 0.0001, respectively). We purified IgA and IgG antibody fractions from three participants at D21 and M3 to evaluate their relative abilities to neutralize SARS-CoV-2 in a neutralization experiment, with syncytium formation in S-Fuse cells as the readout, evaluating the half-maximal neutralizing effective concentration (EC50)20. We found that the purified IgA had a greater neutralizing capacity than IgG in each of the paired serum samples at the early time point (D21; IgA EC50 < IgG EC50), whereas the opposite pattern was observed at M3 (Fig. 3).
Discussion
We describe here the changes over time in IgG, IgA, and IgM antibody profiles associated with the neutralizing activity of serum samples from 26 HCW who recovered from mild forms of SARS-CoV-2 infection. All these HCW displayed seroconversion at D21 after symptom onset, and elicited an NAb response to SARS-CoV-2 correlated with the anti-RBD antibody levels. However, this neutralizing activity appears to be transient, with NAbs decreasing in titer, or even being completely lost, in association with a decrease in systemic IgA antibody levels from 2 months after disease onset.
Our findings are consistent with a very high rate of seroconversion and a temporal pattern of antibody appearance similar to that reported for hospitalized SARS-CoV-2-infected patients in other studies6,7,8,10,14,21,22. It has been reported for SARS-CoV that the peak level of IgG against whole-virus lysate is reached between 4 and 6 months after symptom onset, and that these levels then remain stable for at least 1 year before decreasing16,17. Here, for SARS-CoV-2, IgG antibodies are detected earlier, for anti-N and anti-S antibodies, and their levels seem to remain stable between M2 and M3.
We studied the neutralizing activity of the serum samples from these HCW, a biological marker often correlated with protective immunity19, using a sensitive and reproducible virus neutralization test. The VNT determines the functional ability of antibodies to prevent virus infection in vitro. This assay has also the advantage to study the overall serum neutralizing activity (both isotypes and epitope-specific antibodies), as it is performed on a whole replicating virus. All the serum samples studied had neutralizing activity against a local clinical isolate of SARS-CoV-2 at D21, indicative of a potent protective immune response to SARS-CoV-2 infection, even after mild forms of COVID-19.
Antibodies directed against the S protein are thought to be responsible for neutralizing activity against this virus, particularly those recognizing the RBD epitope, because S protein has been shown to be essential for viral particle entry into target cells, via interactions between the RBD and angiotensin-converting enzyme 2 (ACE2). Moreover, S protein was identified from the structural proteins of SARS-CoV as a major inducer of protective immunity23,24. This suggests that it may be important to assess changes in the levels of antibodies directed against S protein and RBD over time, to improve our understanding of the potential protective immune response to SARS-CoV-2 infection. In our experiments, IgA antibodies were the only antibody isotype to display rapid decreases in both levels and seropositivity rates from M2 onwards. Moreover, anti-RBD IgA antibodies, together with anti-RBD IgG antibodies, displayed the strongest association with NAb titers. This isotype also dominated the early neutralizing activity of the sera, as shown by neutralization experiments on the purified IgA fraction. These findings suggest that IgA antibodies are the major component of the NAbs developed in response to SARS-CoV-2 infection.
Nevertheless, the increase in IgA EC50 at M3 may be explained by the proportion of specific IgA directed against SARS-CoV-2 RBD relative to total systemic IgA decreasing sharply, whereas SARS-CoV-2 anti-RBD IgG levels increased, potentially with an increase in neutralizing activity by somatic hypermutation. However, this increase in both the level and neutralizing activity of IgG directed against S protein may not be sufficient to compensate entirely for the disappearance of neutralizing activity due to IgA. This conclusion is also supported by the presence of anti-S IgA in HCW who were seronegative for anti-S IgG at D21 and the loss of neutralizing activity for serum samples testing positive for anti-S or anti-RBD IgG, but negative for anti-S or anti-RBD IgA. These findings may be explained by the natural course and immunogenicity of SARS-CoV-2 infection, with a probable preferential induction of local and systemic, but not very long-lasting IgA antibodies against the S protein due to the mucosal entry pathway of this respiratory virus.
A recent study in rhesus macaques experimentally infected with SARS-CoV-2 showed the development of NAbs associated with protection against re-infection after a challenge at 35 days25. This result, consistent with our findings and those of other groups, indicates that SARS-CoV-2 infection elicits a protective humoral response, at least temporarily, which may be correlated with the neutralizing activity of sera. Further studies are required to assess the protection correlates after SARS-CoV-2 infection, such as the minimal NAb titer for protection, the contribution of secretory IgA and local immunity, and the neutralizing capacity of anti-S IgG over time, even after the disappearance of circulating IgA.
In conclusion, our results and the recent description of rare cases of SARS-CoV-2 reinfection26,27 are in favor of a potent risk of re-infection in HCW and support strong recommendations to maintain an adequate use of personal protective equipment, and to apply infection prevention and control measures, even for HCW who have recovered from a mild form of COVID-19 and who have antibodies detectable in routine serologic tests, at least until strong correlates of immune protection are identified. This study also suggests that vaccination against SARS-CoV-2 in humans will probably have short lasting protective effect meaning that most people should get vaccinated periodically.
Methods
Study population and sampling
This study was conducted at Pitié-Salpêtrière University Hospital, one of the first hospitals in Paris to manage patients infected with SARS-CoV-2. Symptomatic HCW with a SARS-CoV-2-positive RT-PCR on a nasopharyngeal specimen were included, and serum samples were obtained between 2 and 4 weeks (D21), and then 2 months (M2) and 3 months (M3) after symptom onset. The study was carried out in accordance with the Declaration of Helsinki. This study was a retrospective non-interventional study with no addition to standard care procedures. Reclassifications of biological remnants into research material after completion of the ordered virological tests and data collection were declared to the Sorbonne Université Data Protection Committee under number 2020-025 in accordance with French law. Written informed consent for participation in this study was obtained from all participants.
SARS-CoV-2 IgG, IgA, and IgM immunoassays
Serum IgG, IgA, and IgM levels were determined with commercially available immunoassay kits: an automated chemiluminescent microparticle immunoassay for detecting IgG against SARS-CoV-2 nucleocapsid (N) protein (Architect SARS-CoV-2 IgG assay; Abbott Laboratories), two enzyme-linked immunosorbent assays (ELISA) for detecting IgG or IgA isotype antibodies against the S1 domain of the spike (S) protein (SARS-CoV-2 IgG or IgA ELISA, EuroImmun), two ELISA for detecting IgG or IgA isotype antibodies against the receptor-binding domain (RBD) of the S protein (Anti-SARS-CoV-2 IgG or IgA ELISA, Mediagnost), and one ELISA for detecting IgM against SARS-CoV-2 N and S proteins (Dia.Pro COVID-19 IgM, Dia.Pro Diagnostic Bioprobes srl). All immunoassays were used and interpreted according to the manufacturer’s instructions. Samples for which the results were unclear were retested and considered positive if confirmed to be equivocal, and negative otherwise.
Virus neutralization test
The neutralizing activity of the various serum samples was assessed with a whole virus replication assay using a SARS-CoV-2 strain (GenBank accession number MW322968) isolated from a COVID-19 patient hospitalized at Pitié-Salpêtrière University Hospital. The infection of this patient was confirmed by a positive SARS-CoV-2 RT-PCR on 6 March 2020, and, the virus was isolated by inoculating Vero cells with a sputum sample in our biosafety level-3 (BSL-3) facility. The serum samples were decomplemented by heat inactivation (56 °C for 30 min), subjected to serial twofold dilution (1:5 to 1:2560), and incubated with 50 µl of diluted virus (2 × 103 TCID50/ml) in a 96-well plate at 37 °C for 60 min. We then added 100 µl of a Vero E6 cell suspension (3 × 105 cells/ml) to the mixture and incubated at 37 °C under an atmosphere containing 5% CO2 until the microscopy examination on day 4 to assess the cytopathic effect (CPE). Neutralization antibody titers are expressed as the highest serum dilution displaying 100% inhibition of the CPE. The same positive serum was added to each experiment to assess the reproductivity and specificity of the VNT assay; pre-epidemic serum samples from patients with other HCoV infections (confirmed by RT-PCR with FilmArray® Respiratory Panel 2 plus, Biomérieux) were also tested.
Purification of IgA and IgG antibodies from serum
Serum samples were diluted 1:3 in 1× PBS and incubated for 20 min with Protein G/agarose (Invivogen). IgG-depleted serum was then incubated with peptide M/agarose (Invivogen) for 20 min. Agarose beads were washed three times with 1 ml 1× PBS and incubated with 0.1 M glycine pH 2 for 10 min in ice. The pH was adjusted to 7 with 1 M Tris pH 9, and the eluted IgG and IgA were subjected to buffer exchange in 1× PBS (Vivaspin 500, Sartorius), through a 50 kDa membrane. The concentrations of IgA and IgG were determined by ELISA (Bethyl Laboratories), according to the manufacturer’s instructions.
Neutralization experiments in S-Fuse cells
U2OS-ACE2 GFP1-10 or GFP 11 cells, also known as S-Fuse cells, become GFP-positive when they are productively infected by SARS-CoV-2 (ref. 20). Cells were mixed (ratio 1:1) and plated at a density of 8 × 103 per well in a μClear 96-well plate (Greiner Bio-One). SARS-CoV-2 (BetaCoV/France/IDF0372/2020) (MOI 0.1) was incubated with IgA or IgG at the indicated concentrations for 30 min at room temperature and added to S-Fuse cells. The cells were fixed, 18 h later, in 2% paraformaldehyde, washed and stained with Hoechst stain (dilution 1:1000; Invitrogen). Images were acquired with an Opera Phenix high-content confocal microscope (Perkin Elmer). The area displaying GFP expression and the number of nuclei were quantified with Harmony software 4.8 (Perkin Elmer). The percentage neutralization was calculated from the GFP-positive area as follows: 100 × (1 – (value with IgA/IgG – value in “non-infected”)/(value in “no IgA/IgG” – value in “non-infected”)). The neutralizing activity of each isotype is expressed as the half maximal effective concentration (EC50). We calculated EC50 values (µg/ml) from a reconstructed curve of the percentage neutralization at the various concentrations indicated.
Statistical methods
Continuous variables are expressed as the median and IQR and discrete variables are expressed as numbers and percentages. Statistical analysis was performed with non-parametric tests in GraphPad Prism 6.0. A probability value of p < 0.05 was considered statistically significant. Spearman’s rank correlation coefficients (rs,) were estimated to determine the associations between serum neutralization titers and Ig levels. The results were interpreted according to the strength and direction (r) and the statistical significance (p value) of the correlation. Two-sided Wilcoxon signed-rank tests were used to compare serum Ig levels and NAb titers for HCW sera between D21 and M2 and between D21 and M3.
Reporting summary
Further information on research design is available in the Nature Research Reporting Summary linked to this article.
Data availability
The GenBank accession code for the SARS-CoV-2 strain used in the VNT is MW322968. Source data are provided with this paper.
Change history
10 May 2021
A Correction to this paper has been published: https://doi.org/10.1038/s41467-021-23128-6
References
Zhu, N. et al. A novel coronavirus from patients with pneumonia in China, 2019. N. Engl. J. Med. 382, 727–733 (2020).
Tian, S. et al. Characteristics of COVID-19 infection in Beijing. J. Infect. 80, 401–406 (2020).
Center for Disease Control and Prevention. Infection Control Guidance for Healthcare Professionals about Coronavirus (COVID-19) (2020).
European Centre for Disease Prevention and Control. Infection Prevention and Control and Preparedness for COVID-19 in Healthcare Settings—Third Update. Technical Report (2020).
World Health Organization. Rational use of personal protective equipment for coronavirus disease (COVID-19) and considerations during severe shortages. Interim guidance (2020).
Guo, L. et al. Profiling early humoral response to diagnose novel coronavirus disease (COVID-19). Clin. Infect. Dis. https://doi.org/10.1093/cid/ciaa310 (2020).
Ni, L. et al. Detection of SARS-CoV-2-specific humoral and cellular immunity in COVID-19 convalescent individuals. Immunity https://doi.org/10.1016/j.immuni.2020.04.023 (2020).
Yu, H. et al. Distinct features of SARS-CoV-2-specific IgA response in COVID-19 patients. Eur. Respir. J. https://doi.org/10.1183/13993003.01526-2020 (2020).
Suthar, M. S. et al. Rapid Generation of Neutralizing Antibody Responses in COVID-19 Patients. Cell Reports Medicine. 1, 100040 (2020).
Robbiani, D. F. et al. Convergent antibody responses to SARS-CoV-2 in convalescent individuals. Nature 584, 437–442 (2020).
Houlihan, C. F. et al. Pandemic peak SARS-CoV-2 infection and seroconversion rates in London frontline health-care workers. Lancet Lond. Engl. 396, e6–e7 (2020).
Chen, Y. et al. High SARS-CoV-2 antibody prevalence among healthcare workers exposed to COVID-19 patients. J. Infect. 81, 420–426 (2020).
Rudberg, A.-S. et al. SARS-CoV-2 exposure, symptoms and seroprevalence in healthcare workers in Sweden. Nat. Commun. 11, 5064 (2020).
Long, Q.-X. et al. Clinical and immunological assessment of asymptomatic SARS-CoV-2 infections. Nat. Med. 26, 1200–1204 (2020).
Callow, K. A., Parry, H. F., Sergeant, M. & Tyrrell, D. A. The time course of the immune response to experimental coronavirus infection of man. Epidemiol. Infect. 105, 435–446 (1990).
Wu, L.-P. et al. Duration of antibody responses after severe acute respiratory syndrome. Emerg. Infect. Dis. 13, 1562–1564 (2007).
Lin, Q., Zhu, L., Ni, Z., Meng, H. & You, L. Duration of serum neutralizing antibodies for SARS-CoV-2: lessons from SARS-CoV infection. J. Microbiol. Immunol. Infect. (2020) https://doi.org/10.1016/j.jmii.2020.03.015 (2020).
Anderson, D. E. et al. Lack of cross-neutralization by SARS patient sera towards SARS-CoV-2. Emerg. Microbes Infect. 9, 900–902 (2020).
Plotkin, S. A. Correlates of protection induced by vaccination. Clin. Vaccin. Immunol. 17, 1055–1065 (2010).
Buchrieser, J. et al. Syncytia formation by SARS-CoV-2 infected cells. EMBO J. n/a, e106267 (2020).
Haveri, A. et al. Serological and molecular findings during SARS-CoV-2 infection: the first case study in Finland, January to February 2020. Eurosurveillance 25, 2000266 (2020).
Kellam, P. & Barclay, W. The dynamics of humoral immune responses following SARS-CoV-2 infection and the potential for reinfection. J. Gen. Virol. https://doi.org/10.1099/jgv.0.001439 (2020).
Buchholz, U. J. et al. Contributions of the structural proteins of severe acute respiratory syndrome coronavirus to protective immunity. Proc. Natl Acad. Sci. USA 101, 9804–9809 (2004).
He, Y., Lu, H., Siddiqui, P., Zhou, Y. & Jiang, S. Receptor-binding domain of severe acute respiratory syndrome coronavirus spike protein contains multiple conformation-dependent epitopes that induce highly potent neutralizing antibodies. J. Immunol. 174, 4908–4915 (2005).
Chandrashekar, A. et al. SARS-CoV-2 infection protects against rechallenge in rhesus macaques. Science https://doi.org/10.1126/science.abc4776 (2020).
To, K. K.-W. et al. COVID-19 re-infection by a phylogenetically distinct SARS-coronavirus-2 strain confirmed by whole genome sequencing. Clin. Infect. Dis. https://doi.org/10.1093/cid/ciaa1275 (2020).
Tillett, R. L. et al. Genomic evidence for reinfection with SARS-CoV-2: a case study. Lancet Infect. Dis. 21, P52–58 (2020).
Acknowledgements
The AGM laboratory is funded by Agence Nationale de Recherches sur le SIDA et les hépatites virales (AC43, Medical Virology), the SARS-CoV-2 Program of the Faculty of Medicine of Sorbonne University, the Agence Nationale de la Recherche. The GG laboratory is supported by the Fondation de France, “Tous unis contre le virus” framework Alliance (Fondation de France, AP-HP, Institut Pasteur) in collaboration with the Agence Nationale de la Recherche (ANR Flash COVID19 program) and by the SARS-CoV-2 Program of the Faculty of Medicine of Sorbonne University ICOViD programs. The OS laboratory is funded by Institut Pasteur, the ANRS, the Vaccine Research Institute (ANR-10-LABX-77), Labex IBEID (ANR-10-LABX-62-IBEID), “TIMTAMDEN” ANR-14-CE14-0029, “CHIKV-Viro-Immuno” ANR-14-CE14-0015-01, the Gilead HIV cure program, ANR/FRM Flash Covid PROTEO-SARS-CoV-2 and IDISCOVR, and Fondation pour la Recherche Médicale. We thank Nathalie Aulner and the UtechS Photonic BioImaging (UPBI) core facility (Institut Pasteur), a member of the France BioImaging network, for image acquisition and analysis.
Author information
Authors and Affiliations
Consortia
Contributions
A.-G.M., V.C., S.B., D.B., D.S., O.S. and G.G. planned the research; S.M., I.M., V.L., K.Z., A.G., K.D. and T.B. conducted the experiments; V.L., S.M., I.M., D.P., A.J. and T.B. analyzed the data; S.M., A.-G.M. and V.C. wrote the paper. All the authors read and corrected the manuscript and approved the final version.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Peer review information Nature Communications thanks Ai-Long Huang, Tengchuan Jin and the other, anonymous, reviewer(s) for their contribution to the peer review of this work. Peer reviewer reports are available.
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary information
Source data
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Marot, S., Malet, I., Leducq, V. et al. Rapid decline of neutralizing antibodies against SARS-CoV-2 among infected healthcare workers. Nat Commun 12, 844 (2021). https://doi.org/10.1038/s41467-021-21111-9
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41467-021-21111-9
This article is cited by
-
Seroprevalence of anti-SARS-CoV-2 antibodies in household domestic ferrets (Mustela putorius furo) in Spain, 2019–2023
Veterinary Research Communications (2024)
-
Reduced neutralization against Delta, Gamma, Mu, and Omicron BA.1 variants of SARS-CoV-2 from previous non-Omicron infection
Medical Microbiology and Immunology (2023)
-
Antibody response, associated symptoms and profile of patients presumably infected by SARS-CoV-2 with taste or smell disorders in the SAPRIS multicohort study
BMC Infectious Diseases (2023)
-
Robust induction of B cell and T cell responses by a third dose of inactivated SARS-CoV-2 vaccine
Cell Discovery (2022)
-
Anti-SARS-CoV-2 antibody levels and kinetics of vaccine response: potential role for unresolved inflammation following recovery from SARS-CoV-2 infection
Scientific Reports (2022)
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.