Abstract
Penile shortening after inflatable penile prosthesis for erectile dysfunction is a common postoperative patient complaint and can reduce overall satisfaction with the procedure. In this prospective study we report our results regarding penile dimensions and patient satisfaction outcomes after 1 year of follow-up from AMS™LGX700® penile prosthesis implant with 6 months of vacuum erectile device therapy. Seventy-four selected patients with medically refractory erectile dysfunction underwent AMS™ LGX 700® IPP placement. Postoperatively, patients were assigned vacuum device therapy for 5 min twice daily. Follow-up continued for 1 year after surgery. Dimensional and functional results were assessed. Baseline median preoperative stretched penile length and girth were 14 cm (range 10–17) and 9 cm (range 7–12), respectively. At the end of the study penile median dimensional outcomes were 17 cm (range 13–23) for length and 11 cm (range 10–13) for girth while a median number of 24 pumps (range 18–29) to fully inflate the device was seen. Baseline median International Index of Erectile Function (IIEF-5) score was 9 (range 5–11), at 6 months 20 (range 18–26) and at 1 year was 25 (range 20–27) (p < 0.0001). Median Erectile Dysfunction Inventory of Treatment Satisfaction (EDITS) score at the end of the follow-up was 74 (range 66–78). Our postoperative rehabilitation program is feasible and should be recommended after prothesis surgery in order to increase overall satisfaction with the procedure. Penile postoperative dimensional outcomes were statistically significant improved and complications were negligible.
This is a preview of subscription content, access via your institution
Access options
Subscribe to this journal
Receive 8 print issues and online access
$259.00 per year
only $32.38 per issue
Rent or buy this article
Get just this article for as long as you need it
$39.95
Prices may be subject to local taxes which are calculated during checkout


References
NIH, C.D.P.o.I. NIH Consensus Conference. Impotence. JAMA. 1993;270:83.
Bettocchi C, Palumbo F, Spilotros M, Lucarelli G, Palazzo S, Battaglia M, et al. Patient and partner satisfaction after AMS inflatable penile prosthesis implant. J Sex Med. 2010;7(1 Pt 1):304–9.
Gonzalez-Cadavid NF. Mechanisms of penile fibrosis. Sex Med. 2009;6(Suppl 3):353–62.
Furlow WL, Goldwasser B, Gundian JC. Implantation of model AMS 700 penile prosthesis: long-term results. J Urol. 1988 Apr;139:741–2.
Deveci S, Martin D, Parker M, Mulhall JP. Penile length alterations following penile prosthesis surgery. Eur Urol. 2007 Apr;51:1128–31.
Dillon BE, Chama NB, Honig SC. Penile size and penile enlargement surgery: a review. Int J Impot Res. 2008;20:519–29.
Egydio PH, Kuehhas FE. Penile lengthening and widening without grafting according to a modified ‘sliding’ technique. BJU Int. 2015;116:965–72.
Chung PH, Siegel JA, Tausch TJ, Klein AK, Scott JM, Morey AF. Inflatable penile prosthesis as tissue expander: what is the evidence? Int Braz J Urol. 2017;43:911–6.
Gontero P, Di Marco M, Giubilei G, Bartoletti R, Pappagallo G, Tizzani A, et al. Use of penile extender device in the treatment of penile curvature as a result of Peyronie’s disease. Results of a phase II prospective study. J Sex Med. 2009;6:558–66.
Gontero P, Di Marco M, Giubilei G, Bartoletti R, Pappagallo G, Tizzani A, et al. A pilot phase-II prospective study to test the “efficacy” and tolerability of a penile-extender device in the treatment of “short penis. BJU Int. 2009;103:793–7.
Levine LA, Newell M, Taylor FL. Penile traction therapy for treatment of Peyronie’s disease: a single-center pilot study. J Sex Med. 2008;5:1468–73.
Antonini G, De Berardinis E, Del Giudice F, Busetto GM, Lauretti S, Fragas R, et al. Inflatable penile prosthesis placement, scratch technique and postoperative vacuum therapy as a combined approach to definitive treatment of Peyronie’s disease. J Urol. 2018;200:642–7.
Antonini G, Busetto GM, De Berardinis E, Giovannone R, Vicini P, Del Giudice F, et al. Minimally invasive infrapubic inflatable penile prosthesis implant for erectile dysfunction: evaluation of efficacy, satisfaction profile and complications. Int J Impot Res. 2016;28:4–8.
Rosen RC, Riley A, Wagner G, Osterloh IH, Kirkpatrick J, Mishra A, et al. The international index of erectile function (IIEF): a multidimensional scale for assessment of erectile dysfunction. Urology. 1997;49:822–30.
Pisano F, Falcone M, Abbona A, Oderda M, Soria F, Peraldo F, et al. The importance of psychosexual counselling in the re-establishment of organic and erotic functions after penile prosthesis implantation. Int J Impot Res. 2015;27:197–200.
Althof SE, Corty EW, Levine SB, Levine F, Burnett AL, McVary K, et al. EDITS: development of questionnaires for evaluating satisfaction with treatments for erectile dysfunction. Urology. 1999;53:793–9.
Antonini G, Busetto GM, Del Giudice F, Ferro M, Chung BI, Conti SL, et al. Distal corporal anchoring stitch: a technique to address distal corporal crossovers and impending lateral extrusions of a penile prosthesis. J Sex Med. 2017;14:767–73.
Hellstrom WJ, Montague DK, Moncada I, Carson C, Minhas S, Faria G, et al. Implants, mechanical devices, and vascular surgery for erectile dysfunction. J Sex Med. 2010;7(1 Pt 2):501–23.
Montague DK. Penile prosthesis implantation in the era of medical treatment for erectile dysfunction. Urol Clin North Am. 2011;38:217–25.
Falcone M, Rolle L, Ceruti C, Timpano M, Sedigh O, Preto M, et al. Prospective analysis of the surgical outcomes and patients’ satisfaction rate after the AMS Spectra penile prosthesis implantation. Urology. 2013;82:373–6.
Akin-Olugbade O, Parker M, Guhring P, Mulhall J. Determinants of patients satisfaction following penile prosthesis surgery. 16 J Sex Med. 2006;3:743–8.
Levine LA, Becher EF, Bella AJ, Brant WO, Kohler TS, Martinez-Salamanca JI, et al. Penile prosthesis surgery: current recommendations from the international consultation on sexual medicine. J Sex Med. 2016;13:489–518.
Wang R, Howard GE, Hoang A, Yuan JH, Lin HC, Dai YT. Prospective and long-term evaluation of erect penile length obtained with inflatable penile prosthesis to that induced by intracavernosal injection. Asian J Androl. 2009;11:411–5.
Osterberg EC, Maganty A, Ramasamy R, Eid JF. Pharmacologically induced erect penile length and stretched penile length are both good predictors of post-inflatable prosthesis penile length. Int J Impot Res. 2014;26:128–31.
Wallen JJ, Barrera EV, Ge L, Pastuszak AW, Carrion RE, Perito PE, et al. Biomechanical comparison of inflatable penile implants: a cadaveric pilot study. J Sex Med. 2018;15:1034–40.
Negro CL, Paradiso M, Rocca A, Bardari F. Implantation of AMS 700 LGX penile prosthesis preserves penile length without the need for penile lengthening procedures. Asian J Androl. 2016;18:114–7.
Henry GD, Carrion R, Jennermann C, Wang R. Prospective evaluation of postoperative penile rehabilitation: penile length/girth maintenance 1 year following Coloplast Titan inflatable penile prosthesis. J Sex Med. 2015;12:1298–304.
Sellers T, Dineen M, Salem EA, Wilson SK. Vacuum preparation, optimization of cylinder length and postoperative daily inflation reduces complaints of shortened penile length following implantation of inflatable penile prosthesis. Adv Sex Med. 2013;3:14–18.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Additional information
Publisher’s note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Antonini, G., De Berardinis, E., Busetto, G. et al. Postoperative vacuum therapy following AMS™ LGX 700® inflatable penile prosthesis placement: penile dimension outcomes and overall satisfaction. Int J Impot Res 32, 133–139 (2020). https://doi.org/10.1038/s41443-019-0125-z
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/s41443-019-0125-z
This article is cited by
-
Commentary on posteroperative vaccuum therapy following AMS LGX 700 inflatable penile prosthesis placement: penile dimension outcomes and overall satisfaction
International Journal of Impotence Research (2020)