Introduction

The intracameral route is increasingly being utilised for drug delivery during cataract surgery [1,2,3,4]. Such medical adjuncts to surgery have been shown to reduce surgical complications and improve patient comfort [5,6,7]. Intracameral phenylephrine has been shown in numerous studies to be safe and effective with respect to intra-operative pupil dilatation and also in the management of floppy iris syndrome [1,2,3,4,5,6,7,8,9,10]. Some studies even suggest that intracameral phenylephrine is preferable to mechanical dilation devices during phacoemulsification, in terms of ease of use, reduced surgical time and lower financial costs [11].

Intracameral phenylephrine has a predictable positive action on pupil dilation, with a moderate mydriatic effect demonstrated in concentrations ranging from 0.15 mg/ml to 5.0 mg/ml (approximately 4.3 mm diameter), and a non-linear significant increase in pupil size at higher concentrations (mean pupil size 5.80 mm ± 0.79 (SD) for 15.0 mg/mL (1.5%) and 6.65 mm ± 0.57 for 30.0 mg/mL (3.0%)) [12]. This phenomenon is due to the fact that phenylephrine may bind and stimulate receptors other than the α(1)-receptor at the higher concentrations.

However, it has been our clinical observation that the degree of pupil dilatation varies considerably between patients and can be less predictable than the literature suggests. It is common surgical practice in the United Kingdom that phenylephrine is delivered as a neat 0.2 ml intracameral bolus of either 2.5 or 10% strength (derived from preservative-free Minims (Bausch & Lomb)) via a 1 ml syringe, or following a range of ad-hoc dilutions, designed to reduce the exposure to associated excipients. These excipients include sodium metabisulphite, disodium edetate and purified water.

Previous studies have highlighted the potential for a high degree in variation of drug concentration when using small volume 1 ml syringes for drug formulation, and have cautioned against this practice [13,14,15,16,17,18,19]. Similar concerns have been previously raised with respect to the preparation of intracameral and intravitreal antibiotics [13, 20, 21].

As previously mentioned, there are a range of surgeon preferences for diluting phenylephrine for intracameral use, but these ad-hoc methods are without a clear evidence base. Additionally, such protocols have not been assessed to evaluate dosage accuracy in the clinical environment. One possible reason for the unpredictable response to intracameral phenylephrine could be that the surgeon is unintentionally administering an inaccurately low dosage. We therefore wished to assess the dosage accuracy of intracameral phenylephrine preparation in clinical practice.

Methods

To replicate the clinical scenario of phenylephrine use in the theatre environment, 1 ml syringes (Becton Dickinson, Plastipak), 18 G × 1 1/2in blunt fill needles (Becton Dickinson) and 27 G × 7/8in Rycroft cannulae (Beaver-Visitec International) were used to draw up and deliver the solutions for analysis. Minims Phenylephrine hydrochloride 2.5% (Bausch & Lomb; 0.5 ml vials containing 12.5 mg of drug) and Minims Phenylephrine hydrochloride 10% (Bausch & Lomb; 0.5 ml vials containing 50 mg of drug) were used as the source of phenylephrine. Balanced salt solution (BSS; Alcon) was used for the dilution protocols. Hydrochloric acid (HCl) 0.3% was additionally used for further necessary dilution, and to prevent precipitation of phenylephrine out of the solution which would result in inaccuracies in concentration measurement.

To accurately determine the concentration of the samples used in clinical practice, analysis was carried out using the spectrophotometric method [22]. This validated technique measures how much a chemical absorbs light by measuring the intensity of light as the beam passes through the sample solution. The degree of absorption measured can then be directly correlated to the concentration of the drug, in the form of a standard curve. The relationship between absorbance and concentration must be linear if the standard curve is to be used to determine the concentration of the unknown samples.

Phenylephrine absorption spectra range from 230 to 300 nm with a peak absorption of 273 nm [22]. Samples were therefore analysed using a spectrometer (model: Lambda 25 UV/VIS spectrometer, PerkinElmer) at an absorbance wavelength of 273 nm. It was determined after a series of dilutions of phenylephrine that linearity in the standard curve was achieved with a dilution factor of 77 times. This factor of dilution was therefore applied to all the samples analysed and each sample was repeated 6 times. The sample’s absorbance was then correlated against the standard curve to give the concentration of a 0.2 ml solution.

The dilutions and analysis were carried out by an ophthalmology Specialty Registrar (SG) and a chemistry PhD student (TJ), in controlled conditions in the School of Chemistry, University of Glasgow, UK.

Results

The control standard curve for phenylephrine showed linearity with an R2 = 0.99. As a result of this, the expected clinical concentration for 2.5% minims phenylephrine as a neat bolus would be 25 mg/ml, 12.5 mg/ml for the 1:1 dilution, and 6.25 mg/ml for the 1:3 dilution. The expected concentration for 10% minims phenylephrine as a neat bolus would be 100 mg/ml, 50 mg/ml for the 1:1 dilution, and 25 mg/ml for the 1:3 dilution.

A total of 6 samples for each of the 3 clinical dilution scenarios were analysed, for both the 2.5 and 10% phenylephrine minims, giving an overall total of 36 results. [See Table 1 for mean descriptive results, SDs, standard error of the mean and 95% confidence intervals]

Table 1 Table showing mean descriptive results, the standard deviations (SD), standard error of the mean (SE Mean) and 95% confidence intervals (CI) across a variety of dilutions

To summarise the results using the 2.5% minims phenylephrine: for the neat undiluted bolus, the mean result was 17.9 mg/ml (range 9.5 –30, standard deviation (SD) 8.51). For the 1:1 dilution, the mean result was 11.67 mg/ml (range 7.5–14, SD 2.37). For the 1:3 dilution, the mean result was 2.21 mg/ml (range 0–4.7, SD 1.99).

To summarise the results using the 10% minims phenylephrine: for the neat undiluted bolus, the mean result was 65.15 mg/ml (range 37–85.2, SD 21.74). For the 1:1 dilution, the mean result was 61.52 mg/ml (range 32.1–84.3, SD 20.77). For the 1:3 dilution, the mean result was 37.4 mg/ml (range 0–73.1, SD 31.1).

There was wide variability observed in all the different dilution groups when the actual results were compared with the expected results. This was particularly seen with the 1:3 dilutions for both 2.5 and 10%, as the 95% confidence intervals did not contain the target values. (See Table 2 and boxplot in Fig. 1)

Table 2 Table showing mean percentage deviation from intended results
Fig. 1
figure 1

Box plot demonstrating percentage deviation from expected results, showing variability across all 6 clinical scenarios, and greater variability associated with the 1:3 dilution protocols

There was evidence of significant differences in the percentage deviations from intended results between the different dilutions (ANOVA; p < 0.001). However, there was no evidence of a significant difference between the mean percentage deviations between the 2.5 and 10% concentrations for the different dilutions (p = 0.108), suggesting that the intrinsic protocol was being assessed in our study, rather than the original phenylephrine source. This allowed us to combine the results for both 2.5 and 10% into 3 groups, and perform statistical analysis (Tukey pairwise comparisons). Mean percentage deviation for the 1:3 dilution was significantly greater than for the neat group (p = 0.003), and also when compared to the 1:1 dilution groups (p = 0.001). There was no evidence of a significant difference between 1:1 dilution group and neat group (p = 0.827).

Discussion

We have demonstrated that there is a huge range of variability in the actual results and the difference from intended (expected) results when attempting to dilute intracameral phenylephrine, as demonstrated by the large 95% confidence intervals. Indeed, the 1:3 dilution group did not even contain the target value in their 95% confidence intervals. Our study has shown that the ad-hoc dilution methods currently used to prepare intracameral phenylephrine from Minims are inaccurate and can result in significantly lower concentrations of drug being administered. The potential consequences of such lower inadequate dosages are poor pupillary dilatation and continuation of floppy iris syndrome which could contribute to poorer cataract surgery outcomes. Additionally, it is important for the surgeon to accurately deliver a known concentration of any intracameral drug to reduce the potential risk of toxicity to the corneal endothelium associated with higher doses. A surgeon may be tempted to inject more intracameral phenylephrine on observing an ineffective response, and could inadvertently deliver unknown doses which could have an accumulative toxic effect. Particular care must be taken with phenylephrine in this regard, as it has been shown to have the highest concentration of free radicals of any of the commonly administered intracameral drugs, and accumulative free radical concentrations may contribute towards subsequent Toxic Anterior Segment Syndrome (TASS) [23, 24].

Our study shows that mathematical accuracy of these low volume dilution protocols do not correspond with accuracy in the clinical environment. This is predominantly due to the use of small volume (1 ml) syringes, which are known to be inaccurate for the preparation of medications and should not be used for mixing of solutions [13,14,15,16,17,18,19]. There are 3 factors related to small volume syringes which may have contributed towards our observed findings in our study, those being dead space, air bubbles and concentration gradients.

Firstly, ‘dead space’ within the syringe refers to the volume of a solution retained in the hub and needle when the plunger of the syringe is fully depressed. One study estimated this volume at 0.07 ml in a conventional 1 ml syringe [19]. This volume represents 35% of the total 0.2 ml expected intracameral dosage, and has the consequence that only 0.13 ml of potential drug volume would be administered when using an undiluted neat “bolus”. For the diluted protocols, this dead space volume represents undiluted BSS, which would subsequently be injected along with some (unknown) diluted drug solution. Both scenarios would result in a reduced intracameral drug concentration. Secondly, large air bubbles easily form within 1 ml syringes, especially when drawing up small volumes of fluid from vials which have air pockets within them. This again has consequences of inaccurate dosing. Lastly, inadequate dilution within the syringe, due to the small chamber size preventing mixing, can result in a concentration gradient forming with the weakest dilution most anterior in the syringe. This weak 0.2 ml would then subsequently be injected into the anterior chamber. (See illustration in Fig. 2)

Fig. 2
figure 2

Colour photograph showing the lack of mixing and dead space in a 1 ml syringe, illustrated by drawing up a minim of Fluorescein and 0.5 ml of water for injection

We have observed a wide range of unexpectedly variable concentrations of drug across all the dilution protocols. Rather than diluting the excipients and optimising the drug, this means the surgeon is actually delivering a random quantity of drug when following such protocols.

We were interested to note the wide variability and inaccuracy associated with the use of a 1:3 dilution technique. As previously mentioned, minims phenylephrine contains sodium metabisulphite and disodium edetate as excipients. In real life, these results suggest that the surgeon who has chosen a 10% source to maximise exposure to phenylephrine, yet wishes to minimise the exposure to excipients through 1:3 dilution in a small volume syringe, could inadvertently be either delivering the equivalent of a full concentration neat 10% bolus, or alternatively, an extremely diluted solution with neither significant levels of drug or excipients. This range of inaccuracy and variability is obviously unacceptable, but could it be harmful?

Animal studies have investigated exposure to nonpreserved bisulfite-free phenylephrine 1.5% and demonstrated efficacy and safety [25]. Another study evaluating endothelial cell morphology and viability in the rabbit cornea did not detect any deleterious effect following intracameral exposure to bisulfite-containing phenylephrine (up to 1%) [26]. This would account for the relative safety of the current operating room practice of diluting preservative-free minims of phenylephrine for intracameral use [27].

There are justified concerns regarding the safety of using off-licence intracameral preparations and the potential for errors [13, 28]. These include local ocular risks such as endothelial damage from excipients or preservatives, and incorrect dosages from compounding pharmacies resulting in cases of TASS [13, 28]. Rare cardiovascular effects such as hypertension have been reported, though the direct causation of such systemic events have been questioned [29,30,31,32]. There has been a recently published case series of TASS following cataract surgery due to inadvertent administration of intracameral lidocaine and 2.5% phenylephrine preserved with 10% benzalkonium chloride, where 2 patients ultimately required corneal transplantation [33].

Our study has demonstrated the need for commercially available unpreserved intracameral phenylephrine to be available to ensure accuracy of dosage. There are currently 2 commercially available combination products which contain phenylephrine and are licenced for use in cataract surgery—Mydrane (Laboratoires THEA, Clermont-Ferrand, France), and Omidria (Omeros, Seattle). One bolus intracameral dose of 0.2 ml Mydrane solution contains 0.04 mg of tropicamide, 0.62 mg of phenylephrine hydrochloride and 2 mg of lidocaine hydrochloride. Omidria contains phenylephrine 1.0% and ketorolac 0.3%; 4mls of which is diluted in 500 mL of the ophthalmic irrigating solution [34]. Both these products have been shown to be safe and effective in cataract surgery, to dilate and maintain pupil size by preventing intraoperative miosis, and reducing postoperative ocular pain [1, 2, 5,6,7]. These products do not require any additional preparation prior to use, and so eliminate any potential for dosage errors. In light of our study results demonstrating dosage variability with ad-hoc dilution of phenylephrine for intracameral use, it would be prudent to use a pre-prepared, purpose-designed, commercial surgical adjunct, for both safety and efficacy.

Conclusion

Our study is the first to evaluate intracameral phenylephrine preparation protocols for dosage accuracy. We have used a validated technique to measure the concentrations of the drug under laboratory conditions. Small volume (1 ml) syringes are known to be inaccurate for the preparation of medications and should not be used for mixing of solutions. Our findings provide support to the clinical observation that the degree of drug effect can vary considerably between patients, due to the potentially low and variable concentration of phenylephrine delivered intracamerally. Having bespoke commercial intracameral phenylephrine products available would address this problem and could improve cataract surgical outcomes in the setting of poor pupil dilation and/or floppy iris syndrome.

Summary

What was known before

  • Intracameral adjuncts such as phenylephrine are increasingly used to improve pupil dilatation and address floppy iris syndrome in cataract surgery.

  • These off-licence agents are often delivered following ad-hoc dilutions to minimise endothelial toxicity, but the accuracy of this practice has not been investigated.

What this study adds

  • Current ad-hoc dilution methods used to prepare intracameral phenylephrine are inaccurate and highly variable.

  • Small volume 1 ml syringes should not be used for mixing or dilution of drug.

  • Using commercial intracameral phenylephrine products would address this problem and improve surgical outcomes in cases of poor pupil dilation and/or floppy iris syndrome.