Introduction

Recently, a large number of electronic skins with capabilities of detecting physical/chemical stimuli have been reported for applications in robotics, wearable electronics, and healthcare monitoring devices1,2,3,4,5,6,7,8. Owing to their wearable or body-attachable features, many types of electronic skins (e-skins) have been actively utilized as innovative tools for monitoring radial and carotid blood pressure1,2, and electrophysiological signals3,4 and for oximetry5, as well as drug delivery6. For accurate and reliable monitoring of those signals, e-skins with enhanced sensitivity, selectivity, response time, and mechanical durability are required. In accordance with these demands, e-skins with various bio-inspired micro/nanostructures (e.g., interlocking, hierarchical, crack, whisker, and fingerprint) and 2D or 3D shapes (e.g., serpentine, wrinkle, pyramid, dome, and porous) have been reported aiming to obtain high-performance and multifunctional e-skins9. In particular, owing to their effective geometrical advantages, regular arrays having various microstructures (e.g., hemisphere, pyramid, and pillar) have been used to improve the performance of e-skins based on different operation modes (e.g., resistive, capacitive, piezoelectric, and triboelectric). Specifically, dome-shaped or hemisphere-shaped microstructures have been reported to induce a large change in contact area and localized stress concentration, which are advantageous for fabricating high-performance piezoresistive sensors10 and triggering a large amount of triboelectric charge11 and a high piezopotential in the piezoelectric devices12. On the other hand, a large variation in local strain and compressibility of pyramid-shaped microstructures enhance force sensitivity and expand the dynamic sensing range of e-skins13,14,15. Inspired by the hierarchical structures in nature, such as insect legs, gecko foots, and beetle wings, pillar-shaped microstructures have been reported to provide selective and directional force-sensing properties, as well as stress-confinement effects16,17,18,19. In addition, the strong adhesion properties of pillar structures provide a new possibility for skin-attachable and wearable healthcare devices1.

Considering these geometrical effects of microstructure arrays on the performance of e-skins, previously, geometrical parameters such as shape, size, and space of microstructure arrays have been controlled to enhance the mechanical sensitivity and operation range of piezoresistive20 and capacitive e-skins15 and the power generation of self-powered e-skins16,17,18,21,22,23. Since the geometrical shape of microstructure significantly affects the contact area and localized stress of microstructure under pressure, several attempts to find the relationship between the shape of microstructure and the sensitivity of various e-skins have been performed. For example, Fan et al. controlled the surface of triboelectric sensors with different shapes of microstructure22. Lee et al. Investigated the structural shape effect on the formation of piezoelectric potential to optimize sensor performances23. Deng et al. studied the dependence of interfacial shape of microstructures (cuboid, cylinder, and pyramid) on the sensitivity of capacitive sensors24. Although previous e-skins having different microstructures have successfully shown improved tactile sensing performances, specific to some of desired applications, there have been no systematic studies of the effects of microstructure geometry on force-induced microstructure-deformation and the resulting force sensitivity and selectivity in response to multidirectional mechanical stimuli. In particular, the sensing performance of piezoresistive e-skins with microstructure arrays critically depends on the localized stress distribution of microstructures and the resulting contact area change when external mechanical forces are applied in different directions. Although the interlocked microdome structures have been reported to exhibit high pressure sensitivity25,26, in-depth investigation of the effects of microstructures on the multidirectional sensing performances has not been done. A systematic and in-depth analysis of geometrical effects on sensing performance is important to enable the design of tunable e-skins having high force sensitivity and selectivity, which can be customized for diverse applications.

In this study, multidirectional force sensitive e-skins are shown to possess customizable force sensitivity and selectivity by controlling the specific microstructure geometry. To investigate the underlying relationship between microstructure geometry and force sensing capability, three kinds of piezoresistive sensors were fabricated based on carbon nanotube/elastomer composites having different surface microstructures (e.g., dome, pyramid, and pillar). To facilitate comparison of the geometrical shape effect on the stress sensing properties, an interlocked geometry of the different microstructure arrays was employed. This has been reported to enhance the variation in contact area and localized stress in the microstructures, thereby improving the stress sensitivity and multidirectional force sensing capabilities of e-skins25,26,27,28. For the fundamental understanding of the sensing mechanisms, experimental piezoresistive properties were compared to the finite-element simulation of contact-area change and the localized stress distribution of microstructured e-skins. It was found that piezoresistive e-skins having different microstructures exhibit distinct force sensitivity and selectivity mainly due to the specific variation in contact area, which depended on the geometrical shape of the microstructures, in response to multidirectional forces (e.g., normal, shear, tensile, and bending). As a result, microdome structures presented the best force sensitivities for normal, tensile, and bending stresses. On the other hand, for shear stress, micropillar structures exhibited the highest sensitivity. As proof-of-concept demonstrations for potential applications in wearable healthcare devices, highly sensitive pressure sensors were used for detecting various bio-signals, including sound, human breath, and artery/carotid pulse pressures.

Materials and methods

Fabrication of conductive composites with interlocked microstructures

The synthesis of conductive composites was initiated by dispersion (5 mg/ml) of multi-walled carbon nanotubes (Sigma-Aldrich, 110–190 nm diameter and 5–9 µm length) in chloroform (Samchun, Korea). After 6 h of sonication, well-dispersed MWNTs solution was mixed with PDMS base (Sylgard 184, Dow Corning) with an 8 wt% ratio of MWNTs to PDMS. Subsequently, the MWNT/PDMS solution was mixed with a vortex and dried at 90 °C for 12 h, in order to completely evaporate the chloroform. Prior to the micromolding process, the MWNT/PDMS precursor was combined with a curing agent (PDMS base: curing agent 10:1) and hexane (1 ml per 0.5 g of PDMS) were added for reducing the viscosity of the dried precursor. The prepared MWNT/PDMS composite solution was poured into silicon molds with different micropatterns (i.e., dome, pyramid, and micropillar), followed by air bubble removal and thermal treatment at 90 °C for 4 h, resulting in the preparation of micropatterned MWNT/PDMS composite films.

Silicon molds with micropattern arrays were fabricated via photolithography and etching processes. For manufacturing microdome-patterned and micropillar-patterned PDMS molds, hexagonally patterned photomasks (diameter and pitch: 3 µm and 15 µm for the microdome structure and 10 µm and 15 µm for the micropillar structure, respectively) and a positive photoresist (PR, AZ 5214E) were used for photolithography (mask aligner, MA/BA-6-8, Succ Microtec) on bare silicon wafers. To conduct the dry-etching process, a reverse patterning process was performed by deposition of a 50 nm-thick chrome layer using the thermal evaporation technique and lift-off process of PR using acetone. The chrome layer acted as a hard mask during the dry-etching process. Each chrome-patterned silicon wafer was isotropically or anisotropically etched via reactive ion etching (RIE) or deep reactive ion etching (DRIE) processes, respectively. Finally, each silicon mold for fabricating microdome-patterned and micropillar-patterned PDMS was prepared by removing the chrome layer through wet-etching and coating a self-assembled monolayer (SAM) on each silicon wafer to ease the PDMS-unmolding process. For the micropyramid-patterned PDMS mold, negative PR (AZ nLOF 2035) was patterned on a SiO2/Si wafer (SiO2 layer thickness of 50 nm) via photolithography employing a hexagonally patterned photomask with a 10 µm diameter and 15 µm pitch. The exposed SiO2 was then etched via a RIE process and PR was removed with acetone. The remaining SiO2 acted as a hard mask in the crystallographic wet-etching process of silicon, which was conducted by immersing it in 30 wt% potassium hydroxide for 10 min at 70 °C. Next, the SiO2 mask was completely removed by wet-etching using 4% hydrofluoric acid. After SAM-coating this silicon wafer, the fabrication process was completed.

Characterizations

The geometrical information at the surface of micro-patterned composite films was obtained using field-emission SEM (FE-SEM; S-4800, Hitachi). Surface conductivity of the micro-patterned composites having different fabricating conditions was measured using the four-probe method with a semiconductor analyzer (4200-SCS, Keithley). In addition, the mechanical modulus of the composite films was obtained using a tensile strain tester (Universal Testing Machine, WL2100, WITHLAB Co., Korea) with a strain rate of 500 mm/min.

Measurements of the multifunctional sensing performances of the e-skins

To measure the electrical properties of the e-skins under mechanical forces, a copper electrode is attached uniformly onto the fabricated composite film with silver paste and then thermally annealed at 90 °C for 30 min to minimize the electrical loss at the composite–electrode interface. Next, both composite films were placed facing each other and connected to the electrical measurement systems. To measure the electrical property of e-skins in response to tensile and bending stress, copper electrodes are attached at the side of composite films and polyimide tapes were sued to fasten the electrode on the e-skins. The electrical properties of e-skins that depend on mechanical forces were measured using the two-probe method of the semiconductor analyzer (4200-SCS, Keithley) with an applied voltage of 1–5 V. To precisely apply the mechanical forces, a pushing tester (JIPT-100, Junil Tech) was used for normal pressure, and a tensile/bending test machine (JIPT-200, Junil Tech) was used to apply stretching/bending forces. Shear force was applied with a microstage system (Micro Motion Technology, Korea). In order to evaluate the capability of sound detection, e-skins were exposed to acoustic waves with a 100 Hz frequency from a speaker (SMS-A490, Samsung) at a constant distance of 1 cm and then electrical resistance signals were collected. For the healthcare signal detection, 1 cm2 e-skins were covered with polyimide film and bandaged onto the wrist, neck, and below nose, and the change in electrical signals was recorded to monitor artery and carotid pulse pressures and human breath. To show the possibility of integration with commercially available chip, e-skin was connected to the commercial chip (STM32F030C6T6, STMicroelectronics) and signals are detected by oscilloscope (DPO2022B, Tektronix).

Finite-element method

In order to calculate the contact area and localized stress of microstructured e-skins, structural analysis was conducted using finite–element simulations. Linear elastic materials with experimentally measured mechanical properties followed composite models with different microstructures. For the basic model for numerical analysis of contact area, more than 0.5 million linear tetrahedral and wedge elements (element size: 0.2 (Min.) and 2 (Max.)) with an adaptive mesh-refinement scheme were employed. Each element in case of interlocked microdome, micropyramid, and micropillar has element/volume ratio of 31.8, 55.4, 73.0 and average aspect ratio of 1.54, 1.57, 1.56, respectively. Multidirectional loading conditions were modulated by displacement controls and converted to the corresponding normal, shear, tensile, and bending forces forms. Based on the surface-to-surface contact scheme between two deformable bodies, mechanical contact, localized stress, and thickness of the composite can be obtained under proper loading conditions.

Results and discussion

Electronic skins having interlocked microstructures and different geometries

Figure 1a shows a schematic representation of a piezoresistive e-skin constituting multi-walled carbon nanotubes/polydimethylsiloxane (MWNT/PDMS) composite films having interlocked microstructure arrays. In this case, the piezoresistive properties of the e-skin depend mainly on the bulk film resistance (RF) and the contact resistance (RC) between the two neighboring microstructures of conductive composite films (Fig. 1b). While the piezoresistance of conventional e-skins constituting a planar composite film is affected predominantly by the RF change, the piezoresistance of the interlocked microstructures is dominated by variations in RC. For conductive composites, the piezoresistance is affected mainly by the tunneling resistance29,30. Similarly, in the interlocked MWNT/PDMS composite films of the present work, contact resistance is dominated by the tunneling resistance (RT) between microstructured composite films, which is inversely proportional to the variation in contact area according to the equation RT = (V/J) × (1/ACNT), where V is the applied voltage, J is the current density, and ACNT is the electrical contact area between MWNTs, which is in turn proportional to the physical contact area (AC) between interlocked microstructures25. Therefore, the contact-area change critically affects contact resistance. In addition, the tunneling current (J) through a thin PDMS insulating layer at the interface of interlocked microstructures exponentially increases with decreasing insulating layer thickness (TPDMS)31. As schematically shown in Fig. 1c, the pressure sensing mechanism can be explained as follows. When an external pressure is applied on interlocked microdomes, stress accumulates at the tips of dome structures, and this concentrated stress can easily deform the microdomes and thus increase AC between interlocked microstructures and decrease TPDMS of the PDMS insulating layer between CNTs. These changes in contact area and barrier thickness significantly affect the tunneling currents through the thin PDMS insulating layer, causing a drastic increase in relative-current change as a response to pressure loading.

Fig. 1: Piezoresistive e-skins with interlocked microstructures having different surface morphologies.
figure 1

a Schematic illustration of the main structure of the e-skins with interlocked microstructures. b Schematic showing the bulk film resistance (RF) and the contact resistance (RC) between the two neighboring microstructured films. c Pressure-sensing mechanism of piezoresistive e-skins having interlocked microstructures. d Schematic illustration of conductive composites with different microstructured arrays. e Top and tilted (inset) SEM images of the microstructured composites with different surface morphologies (microdome, micropyramid, and micropillar)

To investigate the effects of microstructure shape on piezoresistance, e-skins having three different surface morphologies (i.e., dome, pyramid, and pillar) were fabricated using the micromolding process (Fig. 1d, e). For this process, silicon replica molds with different micropattern arrays were produced via photolithography and etching processes (the detailed methodology is in the Experimental section). The fabricated microstructures had equal feature sizes; 10 µm diameter, 15 µm pitch, and 6 µm height (Scanning electron microscope (SEM) images in Fig. 1e). For interlocked composite microstructures, high surface conductivity is preferred for enhancing pressure sensitivity due to the drastic RC change with changing contact area under proper loading pressure25. In this study, interlocked composite microstructures having 8 wt% CNTs were utilized. For the different microstructure composites, sheet resistance exhibited similar values, around 1 × 104 ohm/sq (Supplementary Fig. S1).

Multidirectional force-sensing capabilities of microstructured e-skins

Pressure-sensing capability of single microstructured e-skins

Before discussing the structural effect of piezoresistance on interlocked CNT/PDMS composite microstructures, the pressure-sensing properties of single-sided composite films having different surface microstructures was investigated. Single-sided microstructured films have been widely employed to enhance the performance of flexible pressure sensors10,14,17,32 and triboelectric generators11,22. For pressure-sensitive piezoresistance, a flat indium tin oxide (ITO) film was used as the top electrode on the surface of micropatterned composite films (Fig. 2a). In this case, the output current depends on the RF of the bulk film and the RC between the microstructure and electrode. The relative electrical current change (ΔI/I0) as a function of normal pressure applied on top of the ITO electrode increased with increasing applied pressure (Fig. 2b). The ΔI/I0 values of single microstructured films increased as a function of pressure more rapidly in comparison to that of single planar structure. For quantitative analysis, the pressure sensitivity (S) can be calculated using the equation S = (ΔI/I0)/ΔP, where I0 is the initial current, ΔI is the change in current after pressure loading, and ΔP is the change in normal pressure. The linear pressure sensitivity exhibited different values depending on the microstructure shape (18.3, 12.6, and 5.3 kPa−1 for microdome, micropyramid, and micropillar structures, respectively), all of which were much higher than that of a planar structure (0.5 kPa−1) in the low-pressure range (<1 kPa) (Fig. 2b and Supplementary Fig.  S2a). As will be discussed later, the enhanced sensitivity of microstructured films, compared to the planar one, can be attributed to stress concentration at the small contact spot between the microstructure and ITO electrode, which resulted in an increase in contact area and decrease in PDMS barrier thickness, thereby increasing the tunneling current between the microstructure and electrode. For the planar structure, the external pressure mainly induced a change in inter-tube distance within the bulk composite film without affecting the contact area much, resulting in the lower pressure sensitivity than those of microstructures. Compared to the low pressure range, in the medium pressure range (1−10 kPa), the pressure sensitivity decreased: 10.3, 3.3, 0.4, and 0.2 kPa−1 for microdome, micropyramid, micropillar, and planar structures, respectively (Fig. 2b and Supplementary Fig.  S2b), but the effect of microstructure on the sensitivity did not change; sensitivity showed the same tendency as that in the low-pressure range (microdome > micropyramid > micropillar > planar).

Fig. 2: Pressure-sensing capability of single microstructured e-skins.
figure 2

a Schematic illustration of the pressure-sensing principle of single microstructured e-skins with different surface morphologies. b Relative current changes in response to normal pressure. c Finite-element analysis (FEA) of localized stress distributions in response to pressure for different surface microstructure arrays (top layer: ITO, bottom layer: MWNT/PDMS composite). d Calculated relative contact-area changes in response to normal pressure

To further understand the piezoresistance of single-sided composite microstructures, finite-element simulations of contact-area variation of the microstructures under normal pressure were performed. When a pressure of 10 kPa was applied on the composite films, microdome and micropyramid structures exhibited a local stress-concentration at the small contact spots, which was not observed for micropillar structures that do not have those small contact spots (Fig. 2c). In addition to the local stress-accumulation, the applied pressure induced a contact-area change, where dome and pyramid structures exhibited a significantly larger change than planar structures (Fig. 2d). As compared to pillar structures, the significantly smaller initial contact area of dome and pyramid structures under zero pressure led to a greater change in contact area under mechanical pressure (Supplementary Fig. S3), which resulted in a drastic increase in output current (Supplementary Fig. S4). In addition to the contact area, the concentrated stress can decrease the thickness of the PDMS dielectric barrier between the CNT and electrode, which is known to induce an exponential increase in tunneling current31. The change of microstructure thickness in response to pressure (Supplementary Fig. S5) implies that the barrier thickness decreases with increasing pressure. These changes in contact area and barrier thickness significantly increased the tunneling currents through the interface between the electrode and CNT composite as a response to pressure loading.

Pressure-sensing capability of interlocked microstructured e-skins

Considering the pressure-sensing capabilities of single-sided microstructured composites, interlocked composites having double microstructured surfaces are expected to further enhance pressure sensitivity owing to larger pressure-induced deformation of interlocked microstructures. Figure 3a shows the change in output current of CNT/PDMS composites having planar and interlocked microstructures under normal pressure. The interlocked composites with microdome, micropyramid, and micropillar arrays exhibited abrupt increases in current on application of a pressure up to 26 kPa, corresponding to ΔI/I0 values of approximately 1.38 × 106, 4.05 × 105, and 3.91 × 103, respectively, which are significantly higher than those of single microstructured films (ΔI/I0 < 130). This behavior can be attributed mainly to the larger initial thickness of the insulating layer for interlocked microstructures, which resulted in a significantly lower initial current at the low-pressure range (Supplementary Fig. S6) and thus higher ΔI/I0 values compared to single microstructured films (Supplementary Fig. S4). It is worth noting that the interlocked microdome structures exhibited the largest change in current in response to pressure and the lowest minimum detection level (0.09 Pa, corresponding to air flow of 1 m/s on 1.5 × 1.5 cm2 of sensor) compared to the other microstructures, indicating the critical role of inter-microdome contacts on the enhanced piezoresistance (Supplementary Fig. S7). To show the possibility of integration with commercially available chip, e-skin was connected to the commercial chip and was detectable signals on application of pressure (Supplementary Fig. S8). To understand the different trend on ΔI/I0 variations depending on microstructure shapes, finite-element simulations of contact-area change under normal pressure were performed. Figure 3c indicates that the microdome structure exhibited the largest increase in relative contact area (A/A0) as compared to micropyramid and micropillar arrays (the absolute values are shown in Supplementary Fig. S9), supporting the shape-dependent trend of ΔI/I0 variations in Fig. 3a. This simulation result indicates that the rate of contact-area change with respect to pressure decreased in the following order: dome > pyramid > pillar, which is the same tendency as that for single-sided microstructured films.

Fig. 3: Pressure-sensing capability of interlocked microstructured e-skins.
figure 3

a Relative current changes of interlocked e-skins having different microstructures as a function of applied pressure. The magnified graph to the right shows the relative current changes of micropillar and planar structures. b Pressure sensitivity of e-skins for low (<1 kPa), medium (1–10 kPa), and high (>10 kPa) pressure ranges. c Calculated contact area variations of e-skins with interlocked microstructure arrays in response to applied pressure. d FEA showing the localized stress distribution of interlocked microstructure arrays for the applied pressure of 10 kPa. e Experimental tunneling current of e-skins with interlocked microstructures fitted to theoretically calculated tunneling resistance

To elucidate the sensing performances of interlocked microstructure e-skins, pressure sensitivity was analyzed (Fig. 3b and Supplementary Fig. S10). All of the e-skins having interlocked microdome, micropyramid, and micropillar structures exhibited great pressure sensitivity: 47,062 kPa−1, 4569 kPa−1, and 2733 kPa−1 in the low-pressure range (<1 kPa); 90,657 kPa−1, 21,308 kPa−1, and 85 kPa−1 in the medium-pressure range (1–10 kPa); and 30,214 kPa−1, 12,219 kPa−1, and 29 kPa−1 in the high-pressure range (>10 kPa), respectively. Compared to the planar structure, these microstructures exhibited extremely high pressure sensitivity and a wide dynamic pressure range before saturation. This can be attributed to the larger change in contact area (Fig. 3c) and insulating layer thickness (Supplementary Fig. S11) at the interface of interlocked microstructures. Since the tunneling current of interlocked microstructures primarily depends on variations of contact area and insulating layer thickness, it is worth to compare the theoretical calculation of tunneling current with the experimental one to further understand the working mechanism of piezoresistive interlocked microsctructures. The experimental tunneling resistance can be extracted by using the relation RT = RRFRCR, where R is the total resistance of interlocked composite film, RF is the bulk composite film resistance, and RCR is the constriction resistance. RCR can be neglected in our system due to the comparable size between the diameter of MWNTs and intertube contact area29. The theoretical tunneling resistance (RT = (V/J) × (1/ACNT)) can be estimated by calculating the tunneling current density (J) according to Simmons model33 and the actual electrical contact area (ACNT). Figure 3e exhibits theoretical tunneling current of different microstructures, which are fitted to experimental tunneling current. The calculation details are provided in Supplementary Section 1. The theoretical and experimental results match well, which support that variations of contact area and insulating layer thickness significantly affect the tunneling current and thus the pressure sensitivity.

In particular, the interlocked microdome structures exhibited remarkable sensitivities over broad pressure ranges, which are much better than those of previously reported e-skins (Supplementary Table S1). It is also worth noting that there is a critical difference in sensitivity values depending on whether the sensitivity is expressed in terms of either current (S= (ΔI/I0)/ΔP) or resistance (S= (ΔR/R0)/ΔP). In the e-skin system with a drastic variation in electrical response reported in the present study, the sensitivity expressed in terms of current is more adequate for the precise analysis of sensitivity because the relative resistance change becomes 1 (ΔR=RR0R0 and ΔR/R0≈1) and thus underestimates the sensitivity when the initial resistance is significantly higher than the resistance under pressure.

Applications of pressure-sensitive e-skins in robotics and healthcare devices require fast response time and repeated usability. Figure 4a shows the response time of interlocked composites having different microstructures upon loading and unloading of a 10 kPa pressure. The response time of interlocked composites with microdome, micropyramid, and micropillar arrays were 12, 162, and 160 ms, respectively, which were significantly faster than that of planar composite films (420 ms). The slow piezoresistive response time of planar composites can be attributed to the viscoelastic properties of PDMS, which induces a time delay for bulk film deformation in response to stress. On the other hand, the piezoresistive property of interlocked microstructures is dominated by surface microstructure deformation rather than bulk film deformation, leading to minimization of time-delay behavior. Additionally, sufficient void spaces between the interlocked microstructures enabled a facile release of energy, resulting in faster recovery times than that for the planar structure13. In particular, the interlocked microdome arrays exhibited the fastest response time (35 times faster than that of planar structures, Fig. 4a) due to the largest variation in contact area (Fig. 3c), which facilitates the immediate formation of a conductive path. Figure 4b shows the interlocked microstructures also exhibited excellent mechanical stability over repeated cycles. Piezoresistive e-skins having interlocked microstructures presented uniform piezoresistive properties upon repetitive pressure loadings (10 kPa) over 1000 times without any surface crack (Supplementary Fig. S12). In contrast, e-skins having planar structures exhibited non-uniform and unstable piezoresistive properties over repetitive cycles, which can be attributed to incomplete recovery to their original state due to a slow response/relaxation time and a strong stiction between two planar surfaces.

Fig. 4: Response time and durability properties of e-skins with interlocked microstructure arrays.
figure 4

a Response and relaxation times of e-skins under a loading/unloading pressure of 10 kPa. b Mechanical durability of e-skins under repeating a loading/unloading pressure of 10 kPa up to 100 cycles (left) and 1000 cycles (right)

Multidirectional force-sensing capability of interlocked microstructured e-skins

In human fingertip skin, various mechanoreceptors and interlocked epidermal-dermal ridges enable spatiotemporal recognition of intensity, direction, and location of forces applied in different directions, which is critical for hand-manipulation of objects with different shapes. Artificial e-skins that can detect and discriminate multidirectional forces are required in robotic skins, gesture monitoring devices, and other healthcare sensors. Interlocked microstructures can induce a unique microstructure deformation tendency specific to each microstructure geometry depending on the direction of applied forces. This would result in sensitive and selective piezoresistance in multidirectional force sensing. Figure 5 shows the piezoresistive sensing properties of interlocked microstructures having different geometries in response to shear, tensile, and bending stresses.

Fig. 5: Relative current changes and contact area variations of interlocked microstructured e-skins in response to different mechanical forces (shear, stretching, and bending).
figure 5

af Changes in relative current and contact area of e-skins having interlocked microstructures in response to applied multidirectional mechanical stresses: (a, b) shear stress, (c, d) tensile stress, and (e, f) bending stress

Figure 5a shows the shear-force detection properties of interlocked microstructures. In order to engage the upper and lower microstructure layers, a normal preload (~45 kPa) was applied on the upper layer prior to applying shear force. In the linear regime of Fig. 5a, the pillar structure exhibited the highest shear sensitivity (0.54 N−1), which is ~2 and ~4 times larger than that of the dome (0.27 N−1) and pyramid (0.14 N−1) structures. The finite-element simulation results (Supplementary Fig. S13) exhibit that the normal preload induced a microstructure deformation at the contact spots, and the subsequent application of shear force further increased the microstructure deformation in the lateral direction and the contact area between interlocked microstructures. The calculated contact-area change in response to shear force shows that the rate of contact-area variation decreases in the following order: pillar, then dome, and finally the pyramid structure (Fig. 5b), which is the same tendency observed in the experimental results. It is worth noting that the pillar structure exhibited the smaller contact-area change for normal pressure compared to dome and pyramid structures due to the large initial contact area (Fig. 3c). These results imply that once the initial contact is formed between the opposing microstructures under a predefined normal preload, the pillar structure deforms more easily than the other microstructures in response to lateral shear force, which results in the enhanced contact area change and thus improved shear-force sensitivity.

For detecting tensile strain, the micropillar structure exhibited the least sensitive piezoresistance compared to the microdome and micropyramid structures (Fig. 5c). For tensile strain, the output current decreases due to the deformation of hexagonal microstructure arrays into elongated hexagonal arrays in the tensile direction, which results in a decreased contact area and thus decreased output current26. The simulation results indicate that the lateral tensile strain induced a decrease in concentrated stress at the contact spots and in the contact area between opposing microstructured films (Supplementary Fig. S14), leading to a decrease in output current. For the quantitative comparison of strain-sensing properties, a gauge factor (GF) was analyzed. This is defined by the equation GF = (ΔR/R0)/(ΔL/L0), where R is the electrical resistance and L is the length of film. The interlocked microdomes exhibited the largest GF (~16), which was about 2 and 7 times larger than those of the micropyramid (~7) and micropillar (~2.2) structures for tensile strains up to 30% (Supplementary Fig. S15). The calculated contact-area change in Fig. 5d also exhibits a similar tendency with the order microdome, then micropyramid, and finally micropillar for the rate of contact area change in response to tensile strain. As a result of bending strain, the concentrated stress and contact area of interlocked microstructures increased with bending curvature (Supplementary Fig. S16). Similar to normal-pressure and tensile-strain sensing, the interlocked microdome structure exhibited the largest bending strain sensitivity, followed by the micropyramid and micropillar structures (Fig. 5e). The calculated contact-area change in Fig. 5f similarly exhibits the largest contact-area change for interlocked microdome structures.

In addition to force sensitivity, discrimination of multidirectional forces is an essential requirement for practical applications of e-skins. In an interlocked geometry of microstructures, distinct deformation patterns depending on the type of mechanical forces induce unique output current signals specific to the applied forces26. This geometry-specific force-responsive behavior exhibited by interlocked microstructures enables detection and differentiating of multidirectional mechanical stimuli. Each e-skin having different microstructures exhibited unique output current patterns with different signal intensity and response times depending on the type of mechanical forces (normal, shear, tensile, and bending; Fig. 6). It was also observed that differently shaped microstructures exhibited different signal intensities and patterns under the same mechanical stimuli. In particular, microdome structures exhibited the most sensitive piezoresistance for normal pressure, tensile strain, and bending stimuli. In contrast, the micropillar structures showed the most sensitive piezoresistance in response to shear force. All of these different signal patterns are attributed to different magnitudes of deformations of the interlocked microstructures and to response/relaxation times depending on the direction of the applied forces and the shape of the microstructures. Although the microdome structures exhibited the most sensitive piezoresistance for normal pressure, tensile strain, and bending stimuli compared to micropyramid and micropillar structures for the equal microstructures feature sizes (10 µm diameter, 15 µm pitch, and 6 µm height), it is worth to note that the force sensitivity of e-skins also depends on the feature size such as the height, diameter, and pitch of periodic microstructures in addition to the microstructure shape. For example, as shown in Supplementary Fig. S17, the increase of pillar height of micropillar structures results in the enhanced force sensing capabilities. It is expected that the variation of other feature sizes (diameter, pitch) of microstructures significantly affects the multidirectional force sensitivities, which requires further in-depth and systematic studies.

Fig. 6: Multidirectional force sensing capabilities of interlocked microstructured e-skins in response to different mechanical forces (normal, shear, stretching, and bending).
figure 6

Each e-skin exhibits unique output current patterns with different signal intensity and response times depending on the type of mechanical forces

Healthcare device applications of microstructured e-skins

For practical applications of the piezoresistive e-skins in healthcare monitoring devices, the detection of various bio-signals was compared over a wide range of pressures, from acoustic wave (<1 Pa) and human breath (1 Pa–1 kPa) to human pulse pressure (1–10 kPa, e.g., artery pulse pressure, average 30–40 mmHg, 4–5.3 kPa) and carotid pulse pressure (average 35 mmHg, 4.67 kPa)34,35. The detection of acoustic waves allows for the application of e-skins in hearing-aid devices, highly sensitive microphones, and human–machine interfaces. In order to analyze the capability of sound detection, the e-skins were positioned 1 cm away from the speaker (Fig. 7a) and the output currents were measured in response to acoustic waves with sound pressure levels varying from 90 to 110 dB at a constant frequency of 100 Hz (Fig. 7b). As the sound pressure levels increased, the vibration-induced fluctuation of current gradually increased. In particular, the micropillar structure exhibited the best capability to detect acoustic waves, which can be attributed to the vibration-induced fluctuation of large initial contact area of interlocked micropillar structures. The detection of acoustic waves at low acoustic pressure and different frequency is also applicable to verify the precise detection of acoustic wave (Supplementary Fig. S18). Figures S18a and S18b show the detection capability of acoustic wave depending on the sound intensity (60–85 dB) under fixed frequency (50 Hz) and different frequency (50–150 Hz) under fixed intensity (80 dB), respectively. Furthermore, to verify the precise detection, we extracted the detected frequency by a high pass frequency filter (>65 Hz) (Supplementary Fig. S18c) and compared the experimental and theoretical acoustic waves (Supplementary Fig. S18d). The great acoustic wave sensing capabilities of our piezoresistive e-skins are caused by the high pressure sensitivity, which can be favorably compared with the previous acoustic sensors (Supplementary Table S2). Based on the capability to perceive acoustic waves, these e-skins can also recognize the specific words by detecting unique signal patterns with noise filtering process as shown in Fig. 7c. When the e-skins are exposed to sound source of the word “electronic skin” with intensity of 110 dB, different signal patterns can be observed. As expected, the micropillar structure shows the most distinct signal patterns due to the large fluctuation of contact area under tiny vibration. For the detection of human breathing motion, the e-skin was attached right below the nose (Fig. 7d). For repeated breathing motion, all the e-skins exhibited periodical electrical signals corresponding to inspiration/inhalation (Fig. 7e). Particularly, the micropillar structure exhibited the largest change in output current, which can be attributed to the largest shear force sensitivity of micropillar structures, as shown in Fig. 5a. The results also exhibit similar characteristics at low operating-voltages (0.1 and 1 V, Supplementary Fig. S19), where the low operating voltage of 0.1 V is comparable to that of previously reported e-skins (Supplementary Table S1) and provides a great possibility for low power consumption of wearable devices.

Fig. 7: Healthcare monitoring applications of interlocked microstructured e-skins.
figure 7

a Photograph of the acoustic wave detection test using e-skins at a fixed distance of 1 cm from the speaker. b Relative current change of e-skins having interlocked microdome, micropyramid, and micropillar structures in response to different intensities of acoustic waves at a constant frequency of 100 Hz. c Acoustic sound detection capability of the e-skins with interlocked microstructures in response to sound source of “electronic skin”. d Photograph of the human breath detection test using e-skins placed below the nose. e Relative current change of e-skins in response to human breath. f, g Photographs of the blood pressure monitoring test of (f) artery and (g) carotid pulse pressure using e-skins attached onto human wrist and neck. h Relative current changes of the e-skins with interlocked microstructures while monitoring artery pulse pressure (top) and carotid pulse pressure (bottom)

For the detection of artery pulse signals, the output current signals of the e-skins (~1 cm2) were recorded after attaching them onto the wrist (Fig. 7f). All the e-skins having different microstructures showed periodic waveforms of 62 beats/min (Fig. 7h), corresponding to the average heartbeat of adult males. An artery pulse waveform contains three distinguishable peaks: P1 for the main pulse pressure and P2 and P3 for the reflected wave pressures from the hand and lower body, respectively36. The most distinct pressure peaks were observed for the interlocked microdome structures (Fig. 7h), which is in accordance with the highest pressure-sensitivity of microdome structures in the medium pressure regime (1–10 kPa; Fig. 3a). For a quantitative comparison of artery pulse wave detection capabilities, the radial artery augmentation index (AIr = P2/P1) and radial diastolic augmentation (DAI = P3/P1) were analyzed. The AIr and DAI acquired for the microdome and micropyramid structures are 0.53 and 0.19 and 0.54 and 0.2, respectively; this closely matched the average values of healthy 28-year-old males36. However, the interlocked micropillar structure did not exhibit clearly distinguishable pulse pressure peaks. Furthermore, the carotid pulse pressure was measured by attaching e-skins onto the neck (Fig. 7g). The resulting waveforms presented the distinguished peaks corresponding to the inflection point of the carotid distention pressure (P1) and common carotid distention pressure (P2) (Fig. 7h), which provide cardiovascular information based on the pressure augmentation index (PAI), PAI = (P2P1)/(P2P0). Similar to the results for artery pressure, the interlocked microdome structure exhibited the clearest detection peaks due to high sensitivity at the pulse pressure ranges. The PAI value acquired for the microdome structure was in good accordance with that of healthy 28-year-old males (PAI = −3.4)37.

Conclusions

We developed multidirectional force sensitive e-skins which possess customizable force sensitivity and selectivity by controlling the specific microstructure geometries (i.e., microdome, micropyramid, and micropillar). Different microstructure shapes of e-skins exhibited distinguishable variations in contact area and localized stress between the two opposing composite films, which critically affect force sensitivity, selectivity, and response/relaxation times of e-skins for multi-directional (i.e., normal, shear, tensile, and bending) mechanical forces. It was found that microdome structures presented the best force sensitivities for normal, tensile, and bending stresses. For shear stress, micropillar structures exhibited the highest sensitivity. All of the interlocked microstructures exhibited better sensitivities compared to single microstructures and planar films, which can be explained by the finite-element calculation of contact-area change and stress distribution. As proof-of-concept demonstrations, e-skins were successfully employed in the monitoring of various bio-signals over a wide range of pressures, from acoustic wave (<1 Pa) and human breath (1 Pa–1 kPa) to human pulse pressure (1–10 kPa). The findings in this study related to direction-specific sensitivities of e-skins depending on the microstructure shape are a strong precedent for developing high-performance and customizable e-skins for applications requiring direction-specific force-sensing capabilities.