Main

The rate of growth in utero and in the first few months of postnatal life may be a determinant of the risk of developing metabolic disorders and obesity in adulthood (1). Epidemiological evidence suggests that, in full-term neonates, high protein intake during the first 2 y of life may lead to excess fat mass accretion, correlating with obesity later in life (2). In extremely preterm infants, the velocity of growth during the first few weeks of life correlates with neurodevelopmental outcome: achieving maximal growth rate has therefore been a priority for neonatologists. However, weight gain has often been the sole parameter used to assess early growth, whereas evidence in the literature suggests that the composition of weight gain (i.e., fat mass vs. lean body mass) may be a key determinant of later metabolic outcome. There is therefore keen interest among neonatologists, pediatricians, nutritionists, and physiologists in arriving at an accurate determination of body fat mass and, more generally, body composition, so as to optimize the nutritional management of low-birth-weight infants.

Several techniques have been proposed to evaluate body composition (3). Although anthropometric indexes such BMI and skinfold thickness measurement have been used (4), they are not accurate and are not easy to perform in babies. Although dual-energy X-ray absorptiometry (DXA) (5) has been commonly used to assess body composition, it is not routinely performed at the bedside and is associated with a significant, albeit small, exposure to radiation (8.9 µSv as compared with 20 µSv for a chest X-ray) (6). Therefore, DXA cannot be carried out repeatedly to monitor the time course of body composition in the same infant. Consequently, there is need for a safe technique that allows for multiple measurements. Recently air-displacement plethysmography (ADP) has been developed to measure fat mass in young infants (7).

ADP is a noninvasive technique based on the measurement of body volume and using gas laws. However, the use of this method in babies has been described only in a very limited number of studies (8,9). The available validation data are based on the use of bovine tissue phantoms (10). The latter method does not take into account two potentially confounding factors present in a living subject: breathing movements and the maintenance of body temperature (7). Moreover, assessment of body composition by ADP uses Fomon’s reference for fat-free mass (FFM) density. The latter depends on the water content of lean body mass (FFM), which is highly variable during the first few months of life (11,12). Any error in the assumed water content of FFM could therefore distort the results with respect to body composition. A proper method of validation of ADP is therefore required, involving the use of a live animal model. Given its size and physiology, the piglet has been commonly used as a model for human infants (13).

The aim of this study was to assess the accuracy and reproducibility of ADP in comparison with body chemical analyses in newborn piglets, used as a model for low-birth-weight human infants.

Results

Range

The piglets varied widely in weight (1.03–8.49 kg) and biochemical analysis of percent fat mass (%FMBA) (3.2–16.4%) ( Table 1 ). The ranges of body mass and body adiposity in the piglets covered the ranges encountered in preterm and term human babies between birth and 6 mo of age.

Table 1 Selected characteristics of the population of piglets studied and % fat mass determined by ADP

Reproducibility

In each piglet, we carried out four measurements. The coefficient of variation (CV) values for the repeated measurements ranged between 2.2 and 44.1%. The root mean square (RMS)-CV was 17.9%. Table 2 reports CV values for each group of piglets. The values of RMS-CV and median CV for repeatedly measured piglets differed significantly depending on age (d2, d7, or d21), with better precision in older piglets (RMS-CV: 26.7, 11.6, and 14.6% at d2, d7, and d21, respectively). CV values also differed significantly between the three terciles of %FMBA, with less variability among piglets with a higher fat mass. The median CV was 19.3% (25th–75th percentiles: 13.4–29.1) for %FM <5.4%, and 4.9% (3.8–9.3) for %FM >10% ( Figure 1 ). In linear regression analysis, CV was dependent only on %FMBA (R2 adjusted: 0.273).

Table 2 Anthropometric measurements and % fat mass (%FM), determined by ADP and biochemical methods, in three groups of piglets measured at 2, 7, and 21 d of life
Figure 1
figure 1

Reproducibility of ADP determinations (expressed as within-subject CV), based on four measurements performed on the same day in each individual piglet, as a function of fat mass. The population of piglets was divided into terciles of percentage fat mass (%FM), as determined by a biochemical method. First tercile: n = 11, median CV (%FM, ADP) 19.3 (13.4–29.1), RMS-CV: 24.7%. Second tercile: n = 11, median CV (%FM, ADP) 9.8 (6–17.5), RMS-CV: 13.1%. Third tercile: n = 11, median CV (%FM, ADP) 4.9 (3.8–9.3), RMS-CV: 13.48%. ADP, air-displacement plethysmography; CV, coefficient of variation; RMS, root mean square.

Accuracy

Mean %FM values determined by biochemical analysis and ADP were 8.7 ± 4.1% and 8.01 ± 4.03%, respectively. The mean difference (−0.66 ± 1.73%) was significantly different from zero (P = 0.031). Linear regression and Bland–Altman analyses of %FM obtained by each of the methods indicated good agreement ( Figure 2 ). The regression analysis indicated a low standard error of the estimate (1.71) and a high R2 (0.83).

Figure 2
figure 2

Comparison of percentage fat mass (%FM) values determined by ADP and biochemical analyses of the carcasses. (a) Linear regression. Solid line: line for correlation, r2 = 0.83. (b) Bland–Atman plot. Solid lines: 5th and 95th percentiles of the (%FMADP − %FMbiochemical analysis) difference. ADP, air-displacement plethysmography.

As shown in Table 3 , the correlation between %FMBA and %FMADP persisted with R2 >0.8 when equations specific for the physiologic characteristics of piglets were incorporated into the software.

Table 3 Regression analysis of results of percentage fat mass (%FM) determined using ADP and biochemical analysis, using various literature estimates of piglet fat mass density and various equations for the calculation of BSA

Discussion

This study used live newborn piglets to compare the accuracy of body composition determination using ADP with that using biochemical analysis. A reasonably good agreement was observed between the results of ADP and biochemical analyses; ADP underestimated fat mass, the mean difference being 0.66% with an SD of 1.73%. Even though the difference was statistically significant (P = 0.031), the difference seems small and may not be physiologically relevant. The agreement between the two methods was confirmed by the regression analysis of %FM, as per biochemical and ADP methods, and was not dependent on changes in %FM. The findings agree with previous reports on the accuracy of ADP, with a better coefficient of determination (R2 = 0.83) in the current study than previously obtained with bovine tissue phantoms (R2 = 0.76) (9), and the comparison study with the four-compartment reference model using labeled water dilution in children (R2 = 0.73) (8). Such improved accuracy as compared with results from tissue phantoms (9) may be attributable to the use of ADP under conditions close to its recommended use, i.e., with live subjects breathing spontaneously and maintaining a stable body temperature (7). We anesthetized the piglets so as to facilitate the performance of the experiments. However, Ma et al. found that, in human infants, the level of activity of the infant had no effect on the value of fat mass measured (9). We therefore believe that sedation in the piglets in our study was unlikely to have affected the validity of the ADP results. Ellis et al. (8) determined the accuracy of pediatric ADP measurement in comparison with indirect measurements of body composition using the four-compartment model in infants, whereas “true” %FM, used as the reference value, was directly determined by biochemical analysis in our study.

We assessed the reproducibility of ADP determinations by carrying out four separate measurements of %FM within less than 1 h in each piglet. The calculated RMS-CV between measurements is relatively high, at 17.9%. Earlier studies of ADP variability in inanimate, non-animal phantoms, found measurements to be very precise (7). However, with animal phantoms, the CV was dependent on %FMBA, the CV being 18.4% with %FMBA ≤10% and 3.21% with %FMBA >30% (10). In our study, the piglets were thin, with a mean %FMBA of 8.7%, and two-thirds of the population had FMBA of <10%. The mean CV was 8.6% for %FMBA >10%, which seems acceptable. Similarly, the clinical study by Ma et al. reported a change in CV of %FM depending on body weight (9). Given that %FMBA is often >10% (14) in human infants, ADP using the Pea Pod is therefore suitable for the assessment of body composition in most infants. However, in small-for-gestational-age infants and preterm babies, given their lower body %FMBA, it may be prudent to repeat measurements at least twice, all the more so as the babies are able to move during the testing procedure (15).

Our study used a porcine model, which allows for the biochemical analysis of body composition. Previous studies by Ellis et al. (8), and Ma et al. (9) compared ADP results to measures of %FM obtained through indirect methods (8,9). The latter methods assess body composition on the basis of the measurement of total body water and may or may not be combined with the determination of bone mineral content and total body potassium. Both studies demonstrated the accuracy of the ADP method. Nevertheless, indirect measurements such as ADP assume that the density of FFM is known for each individual subject, despite the fact that total body water is known to change dramatically during the first 6 mo of life (12,16). Such variations significantly alter the density of FFM (11,12) and, consequently, the calculation of %FFM and %FM based on body density. Therefore, despite their obvious relevance, human validation studies are of limited value in assessing the accuracy of ADP. This was the rationale for our selection of biochemical analysis as the “gold standard” reference method, which obviously required an animal model.

Piglets have been used earlier to validate several techniques that are relevant for neonatal care (17,18,19), and are considered relevant models for the study of human nutrition (13,20). The %FM for a piglet is only 1% at birth, which corresponds to the %FM of a preterm human infant with a gestational age of 30 wk. Early fat mass accretion is rapid in piglets; %FM reaches up to 15% at 21 d of age, which is close to the %FM of a human full-term newborn infant, or of a premature infant at the time of discharge from the neonatology unit (13,14,15,21). In this study, the piglets selected covered a wide range of %FM. Also, we used modified equations in the software formulas for %FM so as to adapt them to porcine physiologic features (22,23,24,25). The fat mass density in piglets differs slightly from that in human infants (0.914 vs. 0.9007) (26). FFM density was assumed to be approximately the same in piglets and infants, taking into account the fact that total body water is identical between the two species (20). The software of the ADP instrument determines %FMadp on the basis of air pressure measurements in the test chamber and on anthropometric measurements including lung capacity and body surface area (7). Tidal volume and functional residual capacity are comparable in piglets and human infants; we therefore did not adjust the corresponding formulas in the software (27,28). The modified formulas appropriate for the calculation of body surface area in piglets are described (22,23,24,25). The use of such modified equations did not result in significant changes in the accuracy of %FMadp; for example, the coefficient of determination between ADP results and modification of fat mass density and body surface area (Deroth formula) (24) was 0.985. We can therefore conclude that, in our study, ADP produced valid results in piglets.

ADP is of potential interest for the routine determination of body composition of infants in clinical practice. Anthropometry was found to lack accuracy (4). A comparison of the measurement of %FFM and %FM using DXA and biochemical analysis found DXA to be accurate for the determination of %FFM but not for %FM (R2 = 0.36), with a 15% overestimation in the latter (19). In addition, the radiation associated with the measurement precludes the performance of multiple DXA scans for the monitoring of infant growth (5). Quantitative nuclear magnetic resonance was found to be accurate, based on a comparison with biochemical analysis in pigs, and was precise for body weights between 3 and 50 kg (R2 = 0.87) (19). Although quantitative nuclear magnetic resonance is a quick and noninvasive technique just as ADP is, ADP has the additional advantage of being feasible in neonatal intensive care units because of the relatively small size and better mobility of the instrument and the shorter duration required to carry out the measurements.

In conclusion, Although ADP had previously been validated for the assessment of body composition in infants weighing >2 kg or in inanimate tissue phantoms, this study is the first to compare ADP against the reference method, namely, biochemical analysis, in live, spontaneously breathing animals in the same weight range as preterm and low-birth-weight human infants. Although the precision of the ADP method was relatively poor in the low range of % FM, ADP measured fat mass with reasonable precision and accuracy in live animals in the range of body weights seen in low-birth-weight human infants. Our findings suggest that pediatric ADP yields suitable accuracy and precision for use in clinical neonatal practice, provided repeated measurements are performed.

Methods

Animals

The experiment was conducted in accordance with the legislations of the European Union (directive 86/609/CEE) and France (Décret: 2001-464 29/05/01) for the care and use of animals in research (agreement for animal housing number B-35-275-32 and certificate of authorization number 6061 to experiment on live animals). The scientific and technical staff obtained an agreement from the French veterinary service authorities to conduct animal research. To obtain a sample with a wide range of fat mass and body weight, we included three groups of 12 cross-bred piglets (Piétrain × (Large White × Landrace)) from the experimental herd of INRA (St Gilles, France). Two piglets were selected per litter: one with a weight close to the mean litter birth weight (1.30 ± 0.03 kg), and one with a birth weight of approximately the 10th percentile, corresponding to a birth weight of 0.90 ± 0.02 kg. Six pairs of piglets were separated from the respective sows at 2, 7, and 21 d of life. On the day of the experiment, if the weight was out of the range of ADP (1–8 kg), or if the piglet had died, another piglet within the same weight range was selected.

Experimental Design

The piglets were separated from the sows 2 h before they were scheduled to be killed. For 1 h before the test each piglet was housed in an individual cage or, if its weight was <3 kg, in an incubator (air temperature: 33 °C). General anesthesia was achieved with isoflurane (1–8 vol/100 vol; C.S.P, Cournon d’Auvergne, France) delivered in 100% through a veterinary anesthesia ventilator. The piglets were not intubated, and they maintained spontaneous ventilation. Because the presence of excess hair would increase the volume of air trapped close to the skin, and could potentially alter ADP measurements, the piglets were shaved with clippers, washed, and dried. The umbilical cords of the younger piglets were cut before starting the experiment. Just before the first ADP test, an injection of 20 mg/kg of ketamine (Imalgene; Merial, Lyon, France) was administered into the trapezius muscle. Between each of the four ADP measurements, anesthesia with isoflurane was repeated. The piglets were killed at the end of the fourth ADP measurement, using anesthesia by isoflurane, followed by intracardiac T-61 injection (1 ml; Elvetis, Domloup, France). After death, the piglets were frozen until biochemical analysis.

ADP System

The Pea Pod (formerly Life Measurement, now COSMED, Rome, Italy) ADP infant body composition system is a new, noninvasive system designed to evaluate the body composition of babies weighing between 1 and 8 kg. It determines the body volume of a baby placed in an airtight measuring chamber of 37 l. During the test, pressure variations are induced in the measuring chamber. The rise in pressure is linked to the air volume, by laws of gas compression, so that the determination of pressure changes allows determination of the baby’s body volume. The ADP software calculates the baby’s body density, on the basis of the body volume/weight ratio. The atmospheric air present in the lungs and the ambient air that remains trapped around the skin do not obey the same rules of compressibility; therefore, lung volume and body surface area must be taken into account in calculations. Because the presence of hair would increase the volume of air trapped close to the skin, thereby modifying the results of the test, the use of either a hair cap or oil to smooth down the hair has been recommended in human infants (7). In the case of the piglets, we decided to shave them. Body composition is considered as the sum of two compartments: fat mass and FFM. ADP estimates the density of FFM using values extrapolated for babies born preterm, on the basis of Fomon’s and Butte’s equations developed for full-term infants (11,12), assuming the density of fat mass to be constant at 0.9007. The ADP software then calculates the percentage of fat mass (% FMADP) on the basis of body density.

In order to use the instrument software designed for humans, we had to measure the “heights” of the piglets, and assign postnatal and gestational ages to the animals, because those parameters are required for the software to estimate body surface area and lung volume. Each piglet underwent four consecutive ADP tests. We measured the sizes of the piglets in terms of two parameters: (i) length from eyes to hind legs (EL) and (ii) length from snout to hind legs (SL). We used EL for the first and third ADP tests, and SL length for the second and fourth ADP tests. We then analyzed the impact of the method used for length measurement on Pea Pod determination of %FM. The length measure from the snout improved the correlation between ADP values and those obtained from biochemical analysis (r2 = 0.844 vs. 0.787). We therefore subsequently replaced in the Pea Pod’s calculation spreadsheet the EL length used in first and third tests with the SL length to enable the Pea Pod software to produce two new values of %FM using the SL length. For each piglet, we therefore had four values of %FM using SL length, and two values of %FM using EL length. The four results obtained using SL length allowed us to assess the reproducibility of the ADP.

Because the ADP software requires the baby’s age, we also tried several approaches to enter the piglets’ age into the software as if piglets were human babies. For the 21-d-old piglets, we entered the postnatal age of a human baby having the same weight as per French infant growth curves. For the 2- and 7-d-old piglets, we programmed the ADP as if the piglets were preterm human infants born the day of the test. If the anesthesia was not sufficient in any of the experiments, we immediately discontinued the measurement. The ADP software used pediatric formulas based on body surface area, functional residual lung capacity, and FFM density to calculate %FM on the basis of pressure measurements (7,11,12). Because the Pea Pod is designed for human infants, these correcting factors that are valid for humans are embedded in the software (7). We used piglet-specific equations from the veterinary literature to calculate body surface area in the piglets in our experiments (22,23,24,25,26), thereby obtaining appropriate %FM values. We also entered the piglet-specific values of the density of fat mass into the APD software because the piglet-specific values differ from those in humans (0.9140 vs. 0.9007).

Chemical Analysis for Assessment of Body Composition

Whole-body chemical analysis was performed on each piglet. The animals were stored at −20 °C immediately after killing. The frozen animals were minced, and samples were obtained and freeze-dried for further chemical analyses. Analyses were then performed in duplicate on freeze-dried samples. The residual water content after freeze-drying was determined from a 2.0-g sample by drying at +105 °C to constant weight. Lipid content was determined from a 2.5-g sample by solvent extraction using an automatic Soxtec Avanti 2050 extraction system (FOSS, Höganäs, Sweden) as described previously (29). In brief, lipids were extracted using a chloroform and methanol mixture (chloroform:methanol, 2:1; Carlo Erba, Reuil-sur-Brêche, France). The CV (calculated as (100 × SD)/(mean)) of the chemical lipid measurement was 7.4%.

Statistics

All statistical analyses were performed using SPSS (Windows version 16.0; SPSS, Chicago, IL). The values are expressed as mean ± SD. The reproducibility of %FMADP was determined by calculating the SD and CV = (100 × SD)/(mean) for four repeated measurements. Experimental reproducibility was evaluated using RMS-CV for the whole piglet population and for each population studied, as follows: RMS-CV: √∑(CV2/n). For analyzing the differences in CV between piglets, we performed one-way ANOVA, comparing terciles of the population of piglets on the basis of fat mass and age. We also performed stepwise regression analysis, including body weight, body length, age, and %FM as variables in the model.

In order to assess the accuracy of ADP measurements in comparison with results obtained by biochemical analyses, we performed a linear regression analysis with %FM from biochemical analyses (%FMBA) as the dependent variable. The coefficient of determination (R2) and the standard error of the estimate from the linear regression were also calculated. Bland–Altman analysis was used to determine the limits of agreement between the two methods as well as potential bias (30). A paired-sample t-test was used to detect any significant differences between %FMADP and %FMBA. In order to analyze the influence of our software adaptations (i.e., body surface area calculation, tidal volume, and fat mass density), we performed linear regression, analyzing the relation between %FMADP and %FMBA for each hypothesis.

Statement of Financial Support

This project was supported, in part, by grants from Agence Nationale de la Recherche (ANR-05-PNRA-009, Paris, France), the French Society of Neonatology, and Abbott Laboratories.