Paravalvular aortic regurgitation (PAR) after transcatheter aortic valve replacement is common and independently associated with increased morbidity and mortality. The determinants of PAR are uncertain, but new data extend our understanding, and a simple practice change in preprocedural imaging could help dramatically to reduce the incidence of this important complication.
This is a preview of subscription content, access via your institution
Access options
Subscribe to this journal
Receive 12 print issues and online access
$209.00 per year
only $17.42 per issue
Buy this article
- Purchase on Springer Link
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout
References
Waksman, R. From TAVI to TAVR: transforming imagination into reality. Cardiovas. Revasc. Med. 12, 343–344 (2011).
Delgado, V. et al. Multimodality imaging in transcatheter aortic valve implantation: key steps to assess procedural feasibility. EuroIntervention 6, 643–652 (2010).
Tamburino, C. et al. Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis. Circulation 123, 299–308 (2011).
Abdel-Wahab, M. et al. Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry. Heart 97, 899–906 (2011).
Jabbour, A. et al. Multimodality imaging in transcatheter aortic valve implantation and post-procedural aortic regurgitation: comparison among cardiovascular magnetic resonance, cardiac computed tomography, and echocardiography. J. Am. Coll. Cardiol. 58, 2165–2173 (2011).
Willson, A. B. et al. 3-Dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement. A multicenter retrospective analysis. J. Am. Coll. Cardiol. http://dx.doi.org/10.1016/j.jacc.2011.12.015.
Jilaihawi, H. et al. Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation. J. Am. Coll. Cardiol. http://dx.doi.org/10.1016/j.jacc.2011.11.045.
Capelli, C. et al. Patient-specific simulations of transcatheter aortic valve stent implantation. Med. Biol. Eng. Comput. 50, 183–192 (2012).
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing financial interests.
Rights and permissions
About this article
Cite this article
Quail, M., Taylor, A. Super size me? Annular size and paravalvular leak after TAVR. Nat Rev Cardiol 9, 265–266 (2012). https://doi.org/10.1038/nrcardio.2012.38
Published:
Issue Date:
DOI: https://doi.org/10.1038/nrcardio.2012.38
This article is cited by
-
Influence of the Measurement Plane on Aortic Annulus Indices: Structural and Clinical Implications
Cardiovascular Engineering and Technology (2013)