Main

The first Efimov resonance position is crucial to understanding Efimov physics, as from it one may derive the absolute scale of parameters for subsequent Efimov resonances. Previous experiments in homonuclear systems yield an interesting observation: the first Efimov resonance position a appears to follow a universal formula a ≈ −9 rvdW (ref. 14), where rvdW is the van der Waals length of the molecular potential15. Calculations from universal theory based on a single-channel model confirm this ‘van der Waals universality’ for Feshbach resonances with sres > 1 (refs 16,17,18,19,20), where the resonance strength parameter sres characterizes the strength of the coupling between open and closed channels of the Feshbach resonance15. Similar theories also give universal but modified predictions for heteronuclear systems21,22. Further calculations predict significant deviations from the universal prediction for resonances with sres 1 (refs 18,23,24,25). Experiments reaching down to sres = 0.11, however, have shown little or no dependence on sres (ref. 9). Experimental results, including this work, are summarized in Fig. 1.

Figure 1: Deviation of measured first Efimov resonance positions a from predictions based on universal theory ath.
figure 1

For identical bosons, ath = −9.73 rvdW (ref. 17). For the 7Li–87Rb Efimov resonance, the universal prediction yields ath = −1,800a0 (ref. 11). In 6Li–133Cs, ath = −320a0 for the 843 G resonance, ath = −2,150a0 for the 889 G resonance, extracted from ref. 28, and ath = −2,200a0 for the 893 G resonance (see text). To compare systems with different Efimov periods λ, fractional deviations are shown. Previous measurements are plotted as open circles: 133Cs (ref. 14) (black), 7Li (refs 3,5) (red), 39K (ref. 9) (blue), 85Rb (ref. 8) (green), 7Li–87Rb (ref. 11) (orange), and 6Li–133Cs (refs 12,13,28) (magenta). Data from this work are shown as closed circles. Error bars correspond to the one standard deviation total uncertainty.

In this Letter, we compare Efimov spectra in a 6Li–133Cs mixture near one broad (sres = 0.66) and one very narrow (sres = 0.05) interspecies Feshbach resonance at B0 = 889 and 893 G, respectively. These two Feshbach resonances, shown in Fig. 2a, differ significantly in resonance strength, but only slightly in Cs–Cs scattering length (aCsCs = 200 and 260a0, where a0 is the Bohr radius). Therefore, this pair of resonances is an excellent case to assess the influence of the Feshbach resonance strength on Efimov physics while keeping other parameters nearly identical. We observe a significant difference in Efimov resonance position between the two Feshbach resonances. Our measurements also show that the resonance associated with the first Efimov state is suppressed near both Feshbach resonances.

Figure 2: Feshbach resonances employed in this work.
figure 2

a, Calculated scattering lengths as a function of magnetic field in the region of interest, showing a narrow resonance in the Lia–Cs spin channel (blue line) and a broad resonance in the Lib–Cs spin channel (red line)26. The Cs–Cs scattering length is shown as a dashed line. b, c, Cross-thermalization between Li and Cs across the Feshbach resonances after interaction times of 200 and 250 ms, respectively. Gaussian fits yield positions of 888.577(10)(10) and 892.648(1)(10) G, respectively. The shaded region on each plot indicates the one standard deviation statistical uncertainty in Feshbach resonance position, determined from the variance-weighted average of the temperature fits (black curves), while the error bars indicate the 1σ standard error of the mean for individual data points.

To resolve Efimov features near the narrow Feshbach resonance at 893 G, we require milligauss level control of our magnetic field. For this, we improve our magnetic field control from our previous work12. In addition, we develop a scheme to precisely monitor the magnetic field, achieving a precision below 3 mG in each measurement (see Methods). We also incorporate a new dual colour optical trap to eliminate relative gravitational sag of the atoms, which prevented mixing of the two species at temperatures below 200 nK in our previous work12 (see Methods).

With these improvements to the apparatus, we prepare spin-polarized Li and Cs samples at temperatures as low as 50 nK with tunable overlap. We vary magnetic field to tune the interspecies scattering length. In each scan, we randomly order the magnetic fields to eliminate systematic drifts; we also choose an interaction time and overlap to optimize the sensitivity to the collision rate. Details regarding the experimental preparation are provided in the Methods.

To determine the interspecies scattering length a at which features occur, we require precise knowledge of Feshbach resonance positions. Previous work based on three-body loss and radio-frequency spectroscopy26,27 offers a model to extract the scattering length from the magnetic field; however, higher magnetic field precision is needed for analysis near the narrow resonance. We develop a procedure to precisely determine the resonance positions based on cross-species thermalization. We first create a significant temperature difference between Li and Cs samples, with TCs ≈ 45 nK and TLi ≈ 300 nK. After the interaction time, we measure the final temperatures. Near an interspecies Feshbach resonance, enhanced elastic collisions between the two species lead to enhanced interspecies thermalization. This approach has a significant advantage over measurements relying on three-body recombination or radio-frequency spectroscopy because the elastic collision rate is symmetric about the resonance over the small range we probe and does not depend on a complex model to extract the resonance position15.

The interspecies thermalization measurements are shown in Fig. 2. We determine the resonance positions with a Gaussian fit to the measured temperatures. The extracted resonance positions from Li and Cs data agree within the uncertainty. The variance-weighted resonance positions are Bbroad = 888.577(10)(10) G and Bnarrow = 892.648(1)(10) G, where the values in parentheses indicate the statistical and systematic uncertainties, respectively. Notably, the systematic uncertainty is dominated by factors which are common to all measurements. As a result, magnetic field offsets relative to the Feshbach resonance positions, ΔBb and ΔBn, have a reduced systematic uncertainty (see Methods). Our results are consistent with refs 26,27 while offering much higher precision.

To see Efimov features near these Feshbach resonances, we modify the experimental sequence to optimize the three-body loss signal. We prepare Li and Cs at nearly equal temperatures of approximately 100 nK. After the interaction time, we measure Li and Cs atom numbers by absorption imaging (see Methods).

The atomic loss spectra are shown in Fig. 3. Coarse scans across the Feshbach resonances provide context for the Efimov features (see Fig. 3a, e). Finer scans at negative scattering length, shown in Fig. 3c, g, display enhanced loss features, identified as Efimov resonances. These features are qualitatively similar, but with different magnetic field scales. Using a Gaussian fit with a linear background, we determine the Efimov resonance positions to be 0.842(12)(10) and 0.041(1)(2) G above the broad and narrow Feshbach resonance, respectively. Using the model in ref. 27 and our measurements of the Feshbach resonance positions, we calculate the corresponding scattering lengths as a = −2,050(60) and −3,330(240)a0 for the broad and narrow resonance, respectively. The quoted uncertainties in scattering length include the previously discussed statistical and systematic uncertainties in magnetic field, as well as an additional 2% uncertainty in the model27.

Figure 3: Measurement of Efimov features near the broad and narrow Feshbach resonances.
figure 3

All magnetic fields are plotted relative to the Feshbach resonance positions determined in Fig. 2. ad, Features near the broad resonance. eh, Features near the narrow resonance. a,e, Broad scans across the Feshbach resonances. Grey, red, and brown boxes indicate the regions of the fine scans shown in b and f, c and g, and h, respectively. b,f, Scans on the positive scattering length side of Feshbach resonances. Near the narrow resonance (f), we identify suppression of three-body loss at ΔBn = −16(1)(2) mG. Two scans are shown in b. Since the scans are performed under different conditions we scale the data to the average value in the overlapping region, clarifying the overall trend. c,g, Observation of an Efimov resonance on the negative side of each Feshbach resonance, at ΔBb = 842(12)(10) mG (c) and at ΔBn = 41(1)(2) mG (g). d,h, Scans in the range expected for the lower-order Efimov resonance; the blue shaded regions indicate the expected positions assuming a scaling constant within ±10% of λ = 4.88 (ref. 22). Black dashed curves are guides to the eye. Red solid curves are Gaussian fits with quadratic (in f) or linear (in all other cases) backgrounds used to extract positions of features, while the corresponding red shaded regions indicate one standard deviation statistical uncertainty. Error bars indicate the 1σ standard error.

Comparing with our previous measurement near the broad Feshbach resonance at 843 G (ref. 12), where the first Efimov resonance occurs at −323(8)a0, both Efimov resonance positions in the present work are more than a full Efimov period higher in magnitude. This suggests the existence of a lower-order Efimov state. However, searching in the ranges expected from geometric scaling12, we do not observe any additional Efimov resonances (see Fig. 3d, h). The missing feature has been studied for the resonance at 889 G (ref. 28) and arises from a weakly bound Cs2 state, which suppresses the resonance due to the ground Efimov state. We find that the first Efimov resonance is missing for both the broad and narrow Feshbach resonances measured here. Based on this interpretation, the Efimov resonances observed in this work stem from the second Efimov states.

Additionally, we observe suppression of three-body loss at positive interspecies scattering length (see Fig. 3f and Supplementary Information). The suppression occurs at ΔBn = −16(1)(2) mG, corresponding to a = 8,100(1,300)a0. Searching for a similar feature near the broad Feshbach resonance over the range 887.9 to 888.5 G (a = 2,500 to 30,000a0), however, yields no discernible features (see Fig. 3b).

We present the results of all scans in terms of interspecies scattering length in Fig. 4 to compare Efimov features near the broad and narrow Feshbach resonances. To combine all scans, we convert atom number to the three-body recombination coefficient K3 based on a numerical model of three-body loss described in the Methods. Owing to uncertainties in trapping frequencies and overlap between the Li and Cs clouds, we scale K3 to the measured value far from resonance K3(0) (shown in Fig. 4 insets). From this figure, we can clearly see a difference in the Efimov resonance positions for the broad and narrow Feshbach resonances, indicated by the solid arrows. We can also see significant deviation from the universal prediction (magenta dotted lines) for the narrow Feshbach resonance.

Figure 4: Recombination rate near the broad and narrow Feshbach resonances.
figure 4

a,b, Recombination rate K3 is plotted as a function of the inverse scattering length for the broad resonance near 889 G (a) and the narrow resonance near 893 G (b). The recombination rate is normalized to the off-resonant value K3(0), see dashed lines in the insets. Vertical solid arrows indicate Efimov resonance positions. The dashed arrow in b indicates a suppression feature in the three-body loss rate at positive scattering length near the narrow resonance. The magenta dotted lines indicate the positions predicted by the universal theory, while black curves are guides to the eye consisting of the sum of Gaussians. Error bars indicate the 1σ standard error.

For precise quantitative comparison of Efimov resonances, as well as comparison to the universal theory, we summarize Feshbach and Efimov resonance positions in 6Li–133Cs in Table 1. Due to the suppressed resonance from the first Efimov states, discussed above, we compare resonance positions from the second Efimov states, which we label a(2). Between the broad and narrow Feshbach resonances near 890 G, we observe a large difference of 63(12)% in a(2), while the universal theory predicts a much smaller effect of 2.3% (−2,150a0 for the broad resonance, extracted from ref. 28, and −2,200a0 for the narrow resonance, calculated using the same method, outlined in ref. 29). This difference is expected from the small change in aCsCs. Furthermore, the universal prediction is in excellent agreement with measurements for both broad resonances at 843 and 889 G, in spite of the significant difference in aCsCs. This agreement indicates that the universal theory describes broad resonances. However, it does not capture the behaviour of the narrow resonance, as our measurement near the narrow resonance at 893 G deviates from the universal theory by 51(11)%.

Table 1 Summary of Efimov resonances for the three Feshbach resonances in Li–Cs at 843 (ref. 12), 889, and 893 G.

Placing this work in the broader context of previous studies offers insight into the universality of Efimov physics in cold atom systems. Based on the general form K3 {sin2[πlogλ(a/a)] + const.}−1 for a < 0 (ref. 30), we introduce a phase shift ΔΦ = πlogλ(a/ath) which characterizes deviation from the universal prediction and accounts for the scaling constant λ. As such, the metric ΔΦ/π can be used to compare our result to other experiments with different scaling constants (as shown in Fig. 1). Our result at sres = 0.05, the smallest resonance strength thus far investigated, offers a clear deviation of 26(5)% of an Efimov period from the universalprediction (a 5 standard deviation effect). As published theories describing narrow resonances are constrained to homonuclear systems, deeper understanding of the Efimov resonance dependence on sres will require theoretical work tailored to heteronuclear systems beyond single-channel calculations. Nevertheless, our result already suggests a trend of increasing Efimov resonance position with decreasing sres.

Methods

Dual colour optical dipole trap.

In our current work, we use an updated optical dipole trapping scheme. This includes the 1,064 nm elliptical trap and 1,070 nm translatable trap discussed in previous work12,26 with some minor changes. The elliptical trap is approximately 33 by 350 μm at the atomic position, with the tight axis along the vertical direction. As before, it may be translated vertically or modulated to increase its vertical size12. However, as in previous work, gravitational sag separates Cs from Li in this trap at very low temperatures.

To circumvent this, we implement a dual colour trap consisting of 1,064 and 785 nm light co-propagating with the elliptical beam, with maximum powers of 150 and 120 mW, respectively. In our present work, both beams are focused to a waist of 29 μm with the 1,064 nm beam approximately 5 μm above the 785 nm beam. The 785 nm beam pushes Cs up while pulling down Li, allowing us to counteract the difference in gravitational sag. Using this trap, we may maintain perfect overlap at arbitrarily low temperatures by careful choice of the 785 and 1,064 nm, and elliptical beam powers, as well as the elliptical beam position.

As all of these beams are co-propagating, they only very weakly trap atoms along the propagation (axial) direction. While an additional beam is used to provide axial confinement during initial loading, in the final trap this beam is turned off, and axial confinement is provided by magnetic field curvature with a trapping frequency of approximately 6.5 Hz for Cs and 36 Hz for Li near 900 G. The use of magnetic trapping ensures that the atoms are located at the centre of curvature of our magnetic field, allowing us to better measure our magnetic field with only small adjustments to our experimental procedure, as detailed below.

Magnetic field calibration.

As in our previous work, we use the |F, mF〉 = |3,3〉 to |4,4〉 (where F and mF denote the total angular momentum and magnetic quantum number, respectively) microwave transition in caesium to calibrate our magnetic field B. However, we now use a tomographic approach to measure the field in a single execution of the experimental sequence. We use our ability to move the elliptical beam to measure the field curvature to a precision of approximately 95%. To measure the field, we run a modified version of the sequence, omitting most of the caesium evaporation and leaving caesium at a temperature of 1–2 μK. We then use a 1 ms microwave pulse set to a frequency slightly below that which would pump the centre of the cloud, and immediately image the atoms in the |4,4〉 state. Because of the magnetic field curvature, two regions of the cloud are imaged. The separation between these two imaged regions is determined by the magnetic field curvature, the microwave frequency, and the magnetic field at the centre of the cloud. Because we use magnetic trapping to provide axial confinement, our atoms are located at the centre position and, when fully evaporated, are confined to a very small region around it. Thus, for a fixed microwave frequency, we can determine the magnetic field directly from a single image. Images showing this tomographic technique for magnetic field calibration and a fully evaporated cloud for comparison are contained in the Supplementary Methods.

During normal operation, we use this tomographic technique to characterize our field approximately 5 s after every shot. This allows us to know our field, in spite of slow drifts in our field on the order of 30 mG, with a precision of 3 mG from a single experimental execution. There exists a small but nonzero offset between the calibration and the main experimental sequence, and to control for this offset we precisely measure it each day. No detectable drift between the field calibration and the main experimental sequence exists over the course of a day, as verified from several hundred shots taken over the course of several hours.

The primary systematic uncertainty in the magnetic field is due to the uncertainty in the field curvature. For typical experimental conditions, this contributes approximately 3 mG. In addition, temperatures of 100 nK in both lithium and caesium yield a cloud width in the magnetic trap corresponding to approximately 2 mG, leading to slight asymmetric broadening of any features narrower than this. Finally, as noted in the previous paragraph, we measure the offset between the field calibration and the main experimental sequence daily, averaging the measurement until the uncertainty is less than 1 mG. This calibration uncertainty leads to an additional systematic. Combining all of these systematic uncertainties leads to an estimate of the absolute systematic uncertainty of approximately 4 mG. Even with a more conservative estimate of 10 mG which we use in the Letter, our results are not significantly changed.

While systematic errors due to the field curvature influence the absolute magnetic field positions of measured features, they are common to all measurements performed in our system, and therefore do not influence the relative magnetic field positions of these features. For relative magnetic field measurements, the uncertainties due to the magnetic field curvature and the finite temperature effect are negligible. However, the daily offset measurement uncertainty does remain for the relative magnetic field measurement, given by the combined uncertainty of the two uncorrelated offset measurements, leading to a relative systematic uncertainty of 1.4 mG. Finally, the Feshbach resonance position statistical uncertainty must be included, leading to a total relative uncertainty of 2 mG for the narrow Feshbach resonance and 10 mG for the broad Feshbach resonance.

Experimental sequence.

We load and evaporate Li in the dual colour trap and Cs in the elliptical trap in a manner similar to the procedure described in refs 12,26. As the elliptical trap can be translated vertically, Li and Cs are separated for most of the preparation. Preparation ends as Cs is translated to overlap with Li while the beam powers are gradually changed to allow mixing of Li and Cs. At the same time, the field is ramped to a value slightly above the Feshbach resonance to be studied: for the narrow resonance, 850 mG away; for the broad resonance, 5.2 G away. In both cases, the absolute value of the scattering length is below 400a0, sufficient to suppress interactions during the final stage of preparation.

We then jump the magnetic field to the desired value and hold for an interaction time at fixed magnetic field. The magnetic field is varied from one shot to the next over a fixed range, with the order in which points are taken randomized to eliminate slow drifts. The interaction time is held fixed over each field scan. After the interaction time, the field is jumped back to a fixed value for high-field imaging of Li. We then determine the Li and Cs particle number and temperature using absorption imaging.

The sequence differs slightly for different scans. In particular, the cross-thermalization measurement is performed with increased power in the 785 nm beam, as this simultaneously increases the Li trap depth and decreases the Cs trap depth, leading to the required temperature imbalance (TLi = 200–400 nK, TCs = 40–50 nK). Furthermore, with the Li at high temperature, we ensure that it does not form a degenerate Fermi gas, avoiding potential many-body effects which would complicate the cross-thermalization measurement. In addition, during this sequence, the Li and Cs clouds are mostly separated. As a result, the collision rate is reduced, allowing for longer interaction times. This is essential to reduce the importance of the magnetic field settling time of approximately 2 ms. In addition, the three-body recombination rate is suppressed even more than the elastic collision rate by the reduced density in the overlapping region, suppressing three-body loss relative to the cross-thermalization rate.

For the Efimov resonance measurements, a lower 785 nm beam power is used such that the Li and Cs temperatures are approximately equal, with T ≈ 100 nK. However, for measurements very near the Feshbach resonance, we still use partial overlap to slow the three-body recombination rate, reducing the importance of the magnetic field settling time. For measurements far from the Feshbach resonance, with Li–Cs scattering length |a| < 1,000a0, we optimize the overlap between the Li and Cs clouds to compensate for the reduced recombination rate at small scattering length.

After this measurement, we perform a high-field calibration, as detailed above. The total time between the end of the main experimental sequence and the field calibration is <5 s.

Recombination coefficient K3 extraction.

As shown in Fig. 3, raw data consists of the measurement of atom number via absorption imaging after a finite interaction time at a specific magnetic field. To compare data across different days and varying conditions, we convert atom loss into a scaled measurement of the three-body recombination coefficient K3, which is normalized to the measured value far away from resonance K3(0).

To extract the scaled value of K3, we adopt a simple model of loss in our system motivated by a number of observations. First, when Li and Cs are not mixed, we measure a lifetime orders of magnitude longer than when they are mixed. As such, we can neglect both three-body loss due to Cs-only collisions and one-body loss. Second, the variation in temperature across each scan is negligible. This allows us to neglect loss due to cross-thermalization and heating atoms out of the trap. With these approximations, and assuming an equilibrium distribution, the atom number of Li and Cs can be modelled with the following set of differential equations

where G(T) is a time-independent geometric factor accounting for the partial overlap of the clouds given by G(T) = (1/NCs2NLi)∫ nCs2(x, T)nLi(x, T)d3x. The factor of two arises from the fact that two Cs atoms are lost in each three-body recombination collision.

As the enhanced (or suppressed) number of atoms lost is small, we find that typically the species with a smaller number of atoms in a given scan exhibits the best signal to noise. Therefore, when we extract K3 from a given scan, we fit the number of atoms remaining of whichever species shows the largest signal to noise to the above model.

Due to slight changes of the trap from day to day, the geometric factor G(T) is difficult to measure to the level of precision necessary. Therefore, we rescale extracted values of K3 in each scan such that the average values in regions of overlapping magnetic field match across different scans. Further, for clarity in Fig. 4, data are binned according to inverse interspecies scattering length, and presented as the variance-weighted mean of all data in each bin.

Data availability.

The data associated with the plots and this study are available from the corresponding author upon request.

Additional Information

Publisher’s note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.