Abstract
Roche Applied Science has repeatedly set standards for high-speed real-time PCR systems. The new LightCycler® 480 System offers different methods of data analysis for relative quantification of gene-expression behavior. Whereas the ΔΔCT Method provides fast, easy analysis of gene expression, the E-Method from Roche Applied Science can produce more accurate relative quantification data by compensating for differences in target and reference-gene amplification efficiency, either within an experiment or between experiments.
Main
Twenty years ago, the PCR—an amazingly simple idea that would become one of the most revolutionary scientific techniques of the 20th century—was first described. Since then, the invention of real-time PCR technology has permitted further revolutionary advances in DNA analysis. For years, Roche Applied Science has set standards for innovative, high-speed real-time PCR systems.
The innovations started with the carousel-based LightCycler® Real-Time PCR Systems (32 capillaries per run), which are currently widely accepted by the scientific community. Roche Applied Science now extends this tradition of innovation and high performance to higher-throughput applications with the new LightCycler 480 System (96- and/or 384-well plate format).
The cutting-edge LightCycler 480 System (Fig. 1) design includes modular instrumentation and software, high-performance reagents and tailor-made disposables, all of which guarantee the best PCR results. Technological enhancements in the LightCycler 480 System, which include a sophisticated thermal cycler and optical system, permit rapid and precise analysis of gene expression and genetic variation. When combined with assays from Roche Applied Science's new Universal ProbeLibrary—a new probe-based, yet highly flexible, gene-expression assay system—the LightCycler 480 System provides convenient fast-tracking of many research activities.
Effect of efficiency on relative quantification methods
Real-time PCR can be used to accurately quantify a target nucleic acid, using either absolute quantification methods (for example, to determine the actual number of viral copies in a sample) or relative quantification methods (for example, to determine the ratio of a regulated target gene to an unregulated housekeeping gene in the same sample)1,2. As the name suggests, the latter method calculates the normalized values of one gene's expression level relative to another rather than absolute values.
The relative quantification method has become the method of choice for investigating changes in gene expression behavior, such as the expression of a tumor suppressor gene under non-disease and disease conditions. However, the reliability of all relative quantification calculations depends on the quality of the PCR.
Efficiency is a quantitative expression of the quality of the PCR process. The highest-quality PCRs run with an efficiency of 2, meaning that the number of target molecules doubles with every PCR cycle. Unfortunately, PCR efficiency is highly sensitive to many aspects of the reaction that vary from run-to-run (for example, sample preparation, nucleic acid purification, PCR primers and probes). Consequently, two different PCRs may not have identical efficiencies.
A choice of relative quantification methods
For precise relative quantification, the most recent generation of LightCycler Systems (the LightCycler® 2.0 Instrument and the LightCycler® 480 Instrument) offers a choice of different methods of data analysis, such as the ΔΔCT Method and the E-Method, each of which handles the problem of efficiency differently (Fig. 2). Furthermore, these software modules allow fast-tracking research activities based on a highly flexible design.
The ΔΔCT Method was the method used in early relative quantification experiments, and it can still provide fast, easy analysis of gene expression3. This method, however, only provides reliable quantitative data if certain assumptions inherent in the method are met: the efficiency of the PCR assays for both target and reference genes must be optimal and/or identical. For the ΔΔCT calculation, the efficiency of both PCRs is assumed to be 2, which represents a doubling of molecules in each cycle. But if target and reference PCR efficiencies are neither identical nor optimal, the ΔΔCT Method may produce incorrect gene expression data. In such cases, methods that are based on true efficiency values, such as Roche Applied Science's E-Method, can provide more accurate data.
The E-Method can produce more accurate relative quantification data because it can compensate for differences in target and reference gene amplification efficiency either within an experiment or between experiments. The E-Method analyzes the amplification efficiency of target and reference genes by using so-called relative standards. These standards are serial dilutions of a single sample (for example, undiluted, 1:10, 1:100 and so on), where concentration is expressed in relative units (for example, 1, 0.1, 0.01 and so on). By using such dilutions to generate a standard curve, the E-Method avoids the time-consuming preparation of artificial or cloned standards, and the determination of their absolute values. Additionally, as the relative standards contain normal sample material, their amplification efficiencies are very similar to those of all the unknown samples.
Furthermore, the E-Method can normalize for run-to-run differences, such as those caused by variations in reagent chemistry. For such normalization, one sample (for example, one of the relative standards) must be designated a calibrator for the target and for the reference gene. These calibrators are then used repeatedly in subsequent runs during the entire study to guarantee a common reference point and allow comparison of all experiments within the series.
Conclusion
The relative quantification software of the LightCycler Systems provides several highly accurate algorithms for relative quantification. Reliable gene-expression data can be generated with either the ΔΔCT Method or the Roche Applied Science E-Method, depending on the PCR efficiency of a particular experimental system.
Additional information about the LightCycler Systems and the described gene expression approaches is available on the Roche Applied Science Special Interest Page (http://www.lightcycler.com).
LIGHTCYCLER is a trademark of Roche. Patent and license disclaimer information is available online (http://www.lightcycler.com).
References
Edwards, K. et al. Real-Time PCR: An Essential Guide (Horizon Bioscience, Norfolk, 2004).
Bustin, S.A. A–Z of Quantitative PCR (International University Line, La Jolla, 2006).
Livak, K.J. & Schmittgen, T.D. Analysis of relative gene expression data using real-time quantitative PCR and the 2−ΔΔCT method. Methods 25, 402–408 (2001).
Author information
Authors and Affiliations
Corresponding author
Additional information
Disclaimer
This article was submitted to Nature Methods by a commercial organization and has not been peer reviewed. Nature Methods takes no responsibility for the accuracy or otherwise of the information provided.
Rights and permissions
About this article
Cite this article
Tellmann, G. The E-Method: a highly accurate technique for gene-expression analysis. Nat Methods 3, i–ii (2006). https://doi.org/10.1038/nmeth894
Published:
Issue Date:
DOI: https://doi.org/10.1038/nmeth894
This article is cited by
-
Sperm-specific histone H1 in highly condensed sperm nucleus of Sargassum horneri
Scientific Reports (2024)
-
DYT-THAP1: exploring gene expression in fibroblasts for potential biomarker discovery
Neurogenetics (2024)
-
Addition of soluble fiber to standard purified diets is important for gut morphology in mice
Scientific Reports (2023)
-
A trade-off between space exploration and mobilization of organic phosphorus through associated microbiomes enables niche differentiation of arbuscular mycorrhizal fungi on the same root
Science China Life Sciences (2023)
-
Dietary intake of Spirulina platensis alters HSP70 gene expression profiles in the brain of rats in an experimental model of mixed stress
Journal of Genetics (2022)