Abstract
In the standard corticotropin-stimulation test, which is used to assess the function of the hypothalamo–pituitary–adrenal axis, synthetic corticotropin is administered at a dose of 250 µg. Previous studies suggested that tests that use lower corticotropin doses had better discrimination than standard-dose tests possibly by avoiding supraphysiological concentrations of corticotropin. Here, we discuss a meta-analysis by Kazluaskaite et al. that compared standard-dose and low-dose corticotropin-stimulation tests and concluded that the low-dose test has a superior sensitivity and specificity. Superiority over the standard-dose test, however, was only found following a series of internal corrections and adjustments conducted by the investigators that might be inappropriate. Unadjusted meta-analyses demonstrated no advantage of the low-dose test over the standard-dose test. As data on the long-term follow-up of patients with borderline results are only available for the standard 250 µg dose test, this test should continue to be advocated, with assay-specific cut-off levels.
This is a preview of subscription content, access via your institution
Access options
Subscribe to this journal
Receive 12 print issues and online access
$209.00 per year
only $17.42 per issue
Rent or buy this article
Prices vary by article type
from$1.95
to$39.95
Prices may be subject to local taxes which are calculated during checkout
References
Stewart PM et al. (1998) A rational approach for assessing the hypothalamo–pituitary–adrenal axis. Lancet 1: 1208–1210
Dickstein G et al. (1991) Adrenocorticotropin stimulation test: effects of basal cortisol level, time of day, and suggested new sensitive low-dose test. J Clin Endocrinol Metab 72: 773–789
Mayenknecht J et al. (1998) Comparison of low- and high-dose corticotropin stimulation tests in patients with pituitary disease. J Clin Endocrinol Metab 83: 1558–1562
Dorin RI et al. (2003) Diagnosis of adrenal insufficiency. Ann Intern Med 139: 194–204
Kazlauskaite R et al. (2008) Corticotropin tests for hypothalamic-pituitary-adrenal axis insufficiency: a meta-analysis. J Clin Endocrinol Metab [10.1210/jc.2008-0710]
Abdu TA et al. (1999) Comparison of the low-dose short synacthen test (1 µg), the conventional-dose short synacthen test (250 µg), and the insulin-tolerance test for assessment of the hypothalamo-pituitary-adrenal axis in patients with pituitary disease. J Clin Endocrinol Metab 84: 838–843
Agha A et al. (2006) The long-term predictive accuracy of the short synacthen (corticotropin) stimulation test for assessment of the hypothalamic-pituitary-adrenal axis. J Clin Endocrinol Metab 91: 43–47
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing financial interests.
Rights and permissions
About this article
Cite this article
Stewart, P., Clark, P. The low-dose corticotropin-stimulation test revisited: the less, the better?. Nat Rev Endocrinol 5, 68–69 (2009). https://doi.org/10.1038/ncpendmet1038
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/ncpendmet1038
This article is cited by
-
The unresolved riddle of glucocorticoid withdrawal
Journal of Endocrinological Investigation (2017)