Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

  • Letter
  • Published:

High-resolution magnetic resonance spectroscopy using a solid-state spin sensor

Abstract

Quantum systems that consist of solid-state electronic spins can be sensitive detectors of nuclear magnetic resonance (NMR) signals, particularly from very small samples. For example, nitrogen–vacancy centres in diamond have been used to record NMR signals from nanometre-scale samples1,2,3, with sensitivity sufficient to detect the magnetic field produced by a single protein4. However, the best reported spectral resolution for NMR of molecules using nitrogen–vacancy centres is about 100 hertz5. This is insufficient to resolve the key spectral identifiers of molecular structure that are critical to NMR applications in chemistry, structural biology and materials research, such as scalar couplings (which require a resolution of less than ten hertz6) and small chemical shifts (which require a resolution of around one part per million of the nuclear Larmor frequency). Conventional, inductively detected NMR can provide the necessary high spectral resolution, but its limited sensitivity typically requires millimetre-scale samples, precluding applications that involve smaller samples, such as picolitre-volume chemical analysis or correlated optical and NMR microscopy. Here we demonstrate a measurement technique that uses a solid-state spin sensor (a magnetometer) consisting of an ensemble of nitrogen–vacancy centres in combination with a narrowband synchronized readout protocol7,8,9 to obtain NMR spectral resolution of about one hertz. We use this technique to observe NMR scalar couplings in a micrometre-scale sample volume of approximately ten picolitres. We also use the ensemble of nitrogen–vacancy centres to apply NMR to thermally polarized nuclear spins and resolve chemical-shift spectra from small molecules. Our technique enables analytical NMR spectroscopy at the scale of single cells.

This is a preview of subscription content, access via your institution

Access options

Buy this article

Prices may be subject to local taxes which are calculated during checkout

Figure 1: NV-ensemble sensor for CASR NMR.
Figure 2: NMR detection using CASR.
Figure 3: CASR-detected molecular NMR spectra.

Similar content being viewed by others

References

  1. Mamin, H. J . et al. Nanoscale nuclear magnetic resonance with a nitrogen-vacancy spin sensor. Science 339, 557–560 (2013)

    Article  CAS  ADS  Google Scholar 

  2. Staudacher, T . et al. Nuclear magnetic resonance spectroscopy on a (5-nanometer)3 sample volume. Science 339, 561–563 (2013)

    Article  CAS  ADS  Google Scholar 

  3. DeVience, S. J . et al. Nanoscale NMR spectroscopy and imaging of multiple nuclear species. Nat. Nanotechnol. 10, 129–134 (2015)

    Article  CAS  ADS  Google Scholar 

  4. Lovchinsky, I . et al. Nuclear magnetic resonance detection and spectroscopy of single proteins using quantum logic. Science 351, 836–841 (2016)

    Article  CAS  ADS  MathSciNet  Google Scholar 

  5. Aslam, N . et al. Nanoscale nuclear magnetic resonance with chemical resolution. Science 357, 67–71 (2017)

    Article  CAS  ADS  Google Scholar 

  6. Berger, S & Sicker, D. Classics in Spectroscopy Isolation and Structure Elucidation of Natural Products 1st edn (Wiley-VCH, 2009)

  7. Walsworth, R. L., Glenn, D. R. & Bucher, D. B. Synchronized-readout for narrowband detection of time-varying electromagnetic fields using solid state spins. US patent application 62/341,497 (filed 25 May 2016); International patent application PCT/US17/34256 (filed 24 May 2017)

  8. Schmitt, S . et al. Submillihertz magnetic spectroscopy performed with a nanoscale quantum sensor. Science 356, 832–837 (2017)

    Article  CAS  ADS  Google Scholar 

  9. Boss, J. M ., Cujia, K. S ., Zopes, J & Degen, C. Quantum sensing with arbitrary frequency resolution. Science 356, 837–840 (2017)

    Article  CAS  ADS  Google Scholar 

  10. Schirhagl, R . et al. Nitrogen-vacancy centers in diamond: nanoscale sensors for physics and biology. Annu. Rev. Phys. Chem. 65, 83–105 (2014)

    Article  CAS  ADS  Google Scholar 

  11. Herzog, B. E ., Cadeddu, D ., Xue, F ., Peddibhotia, P & Poggio, M. Boundary between the thermal and statistical polarization regimes in a nuclear spin ensemble. Appl. Phys. Lett. 105, 043112 (2014)

    Article  ADS  Google Scholar 

  12. Meriles, C. A . et al. Imaging mesoscopic nuclear spin noise with a diamond magnetometer. J. Chem. Phys. 133, 124105 (2010)

    Article  ADS  Google Scholar 

  13. Staudacher, T . et al. Probing molecular dynamics at the nanoscale via an individual paramagnetic centre. Nat. Commun. 6, 8527 (2015)

    Article  CAS  ADS  Google Scholar 

  14. Zaiser, S . et al. Enhancing quantum sensing sensitivity by a quantum memory. Nat. Commun. 7, 12279 (2016)

    Article  CAS  ADS  Google Scholar 

  15. Rosskopf, T., Zopes, J., Boss, J. M. & Degen, C. L. A quantum spectrum analyzer enhanced by a nuclear spin memory. npj Quantum Inf. 3, 33 (2017)

    Article  ADS  Google Scholar 

  16. Bloembergen, M ., Purcell, E. M & Pound, R. V. Relaxation effects in nuclear magnetic resonance absorption. Phys. Rev. 73, 679–712 (1948)

    Article  CAS  ADS  Google Scholar 

  17. Olson, D. L ., Peck, T. L ., Webb, A. G ., Magin, R. L & Sweedler, J. V. High-resolution microcoil 1H-NMR for mass-limited, nanoliter-volume samples. Science 270, 1967–1970 (1995)

    Article  CAS  ADS  Google Scholar 

  18. Fratila, R. M & Velders, A. H. Small-volume nuclear magnetic resonance spectroscopy. Annu. Rev. Anal. Chem. 4, 227–249 (2011)

    Article  CAS  Google Scholar 

  19. Ryan, H ., Smith, A & Utz, M. Structural shimming for high-resolution nuclear magnetic resonance spectroscopy in lab-on-a-chip devices. Lab Chip 14, 1678–1685 (2014)

    Article  CAS  Google Scholar 

  20. Liao, S. H . et al. A study of J-coupling spectroscopy using the Earth’s field nuclear magnetic resonance inside a laboratory. Rev. Sci. Instrum. 81, 104104 (2010)

    Article  ADS  Google Scholar 

  21. Babij, N. R . et al. NMR chemical shifts of trace impurities: industrially preferred solvents used in process and green chemistry. Org. Process Res. Dev. 20, 661–667 (2016)

    Article  CAS  Google Scholar 

  22. Waddington, D. E. J . et al. Nanodiamond-enhanced MRI via in situ hyperpolarization. Nat. Commun. 8, 15118 (2017)

    Article  ADS  Google Scholar 

  23. Abrams, D ., Trusheim, M. E ., Englund, D. R ., Shattuck, M. D & Meriles, C. A. Dynamic nuclear spin polarization of liquids and gases in contact with nanostructured diamond. Nano Lett. 14, 2471–2478 (2014)

    Article  CAS  ADS  Google Scholar 

  24. Mousoulis, C ., Xu, X ., Reiter, D. A & Neu, C. P. Single cell spectroscopy: noninvasive measures of small-scale structure and function. Methods 64, 119–128 (2013)

    Article  CAS  Google Scholar 

  25. Grisi, M . et al. NMR spectroscopy of single sub-nL ova with inductive ultra-compact single-chip probes. Sci. Rep. 7, 44670 (2017)

    Article  CAS  ADS  Google Scholar 

  26. Grant, S. C . et al. NMR spectroscopy of single neurons. Magn. Reson. Med. 44, 19–22 (2000)

    Article  CAS  Google Scholar 

  27. Fessenden, M. Metabolomics: Small molecules, single cells. Nature 540, 153–155 (2016)

    Article  CAS  ADS  Google Scholar 

  28. Marusyk, A ., Almendro, V & Polyak, K. Intra-tumour heterogeneity: a looking glass for cancer? Nat. Rev. Cancer 12, 323–334 (2012)

    Article  CAS  Google Scholar 

  29. Glenn, D. R . et al. Single-cell magnetic imaging using a quantum diamond microscope. Nat. Methods 12, 736–738 (2015)

    Article  CAS  Google Scholar 

  30. Teschler, J. K . et al. Living in the matrix: assembly and control of Vibrio cholerae biofilms. Nat. Rev. Microbiol. 13, 255–268 (2015)

    Article  CAS  Google Scholar 

  31. Acosta, V. M . et al. Temperature dependence of the nitrogen-vacancy magnetic resonance in diamond. Phys. Rev. Lett. 104, 070801 (2010)

    Article  CAS  ADS  Google Scholar 

  32. Wheeler, D. D. & Conradi, M. S. Practical exercises for learning to construct NMR/MRI probe circuits. Concepts Magn. Reson. 40A, 1–13 (2012)

    Article  CAS  Google Scholar 

  33. Badilita, V. et al. Microscale nuclear magnetic resonance: a tool for soft matter research. Soft Matter 8, 10583–10597 (2012)

    Article  CAS  ADS  Google Scholar 

  34. Finch, G., Yilmaz, A. & Utz, M. An optimized detector for in-situ high-resolution NMR in microfluidic devices. J. Magn. Reson. 262, 73–80 (2016)

    Article  CAS  ADS  Google Scholar 

Download references

Acknowledgements

This material is based on work supported by, or supported in part by, the US Army Research Laboratory and the US Army Research Office under contract/grant number W911NF1510548. D.B.B. was partially supported by the German Research Foundation (BU 3257/1-1). M.D.L. acknowledges support from the Gordon and Betty Moore foundation. We thank R. Fu for assisting with acquisition of the electromagnet used to apply the bias field, M. Rosen for guidance on NMR techniques and S. DeVience for assisting with SpinDynamica calculations of NMR spectra at low B0.

Author information

Authors and Affiliations

Authors

Contributions

R.L.W., D.R.G. and D.B.B. devised the synchronized readout technique. D.R.G., D.B.B. and R.L.W. conceived the application of the technique to picolitre-scale NMR measurements, designed the experiments and analysed the data. D.B.B. and D.R.G. designed and constructed the ensemble NV magnetometer and wrote the accompanying control software. J.L. carried out the single-NV synchronized readout experiments with incoherent averaging. M.D.L., H.P. and R.L.W. conceived the application of NV diamond magnetometry to NMR detection at short length scales. All authors discussed the results and participated in writing the manuscript.

Corresponding author

Correspondence to Ronald L. Walsworth.

Ethics declarations

Competing interests

The authors declare no competing financial interests.

Additional information

Reviewer Information Nature thanks D. Budker and the other anonymous reviewer(s) for their contribution to the peer review of this work.

Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Extended data figures and tables

Extended Data Figure 1 Sensitivity of the NV-ensemble sensor.

a, Synchronized readout (SR) measurements of magnetic test signals from a nearby coil antenna at fcoil = 3.742 MHz (Supplementary Methods 1). The control voltage for the AC current source of the coil was varied from Vc = 0 to Vc = 0.35 V. Each blue trace corresponds to a different value of the control voltage. The amplitude of the oscillating magnetic field that is produced by the coil (bac) is proportional to Vc. The amplitude of the measured synchronized readout signal increases with Vc. b, Synchronized readout signal data (blue points) as a function of control voltage Vc at constant time tmin ≈ 0.53 ms, obtained by cutting the data shown in a along the dashed line. The red line is a sinusoidal fit to the data, from which we obtain the control voltage Vc = 0.22 V that produces a π/2 NV phase accumulation in a single magnetometry subsequence. The π/2 NV phase accumulation occurs when the fluorescence signal is at its minimum, S(π/2). This provides a calibration for the amplitude of the applied test signal. c, Synchronized readout amplitude spectrum of a 10.0-nT test signal (fcoil = 3.752 MHz), recorded in T = 0.96 s. The calibrated signal amplitude defines the vertical axis of the plot. The rectangular window shows the frequency range used to estimate the noise in the spectrum. The noise amplitude σB is determined by comparing with the calibrated test signal. d, Synchronized readout noise measurements as a function of averaging time for acquisition durations of 0.96 s (blue circles) and 0.05 s (grey boxes). A power-law fit to the 0.96 s data (red line) indicates an inverse square-root scaling with time and a sensitivity of ηB = 32 ± 4 pT Hz−1/2. AU, arbitrary units; RMS, root-mean-square.

Extended Data Figure 2 Electromagnet stabilization.

a, Time-series data of magnetic field (B0) deviations, recorded at the primary (NMR) NV-diamond-ensemble sensor, once every 5 min, over 48 h. b, Histogram of the data in a, showing a Gaussian distribution of magnetic-field deviations with a standard deviation of 46 nT. Because the measurement precision of the sensors and the current precision of the coil used to correct B0 were both much smaller than the actual B0 fluctuations, the deviation from the set-point was effectively zero immediately after every feedback adjustment. Assuming linear drift of the magnetic field during each (5-min) feedback interval, the average magnetic-field deviation from the set-point during the interval was approximately half the value recorded at the end of the interval. The real standard deviation of the magnetic-field fluctuations at the primary NV-NMR sensor was therefore estimated to be about 23 nT. c, Schematic of the electromagnet and sensors, drawn to scale. The black coils are the main magnet coils (88 mT); copper coils are the correction coils for fast control of B0.

Extended Data Figure 3 Estimate of NMR measurement volume.

a, Fluorescence image of the NV sensing volume. The image shown has been stretched by 21/2 in the horizontal (x) direction to account for the 45° angle between the imaging plane and the diamond surface. Scale bar, 30 μm. b, c, Cuts through the image in a (horizontal, b; vertical, c) fitted to Gaussian line shapes. The extracted spot size was 27 μm FWHM in x and 20 μm in y. d, Example random configuration of NV centres (purple) and sample protons (grey) generated by the Monte Carlo calculation (Supplementary Note 3) used to estimate the total NMR signal magnitude integrated over the sensor. The NV-sensor volume is modelled as an elliptic cylinder with semi-axes of 14 μm in x and 10 μm in y and a height of 13 μm in z. The set of protons shown corresponds to a 25 pl half-ellipsoid measurement volume. The diamond surface is at z = 0. e, Calculated NMR signal, integrated over the NV-sensor volume and normalized to the asymptotic NMR signal at large sample volume. The integral over the sample was carried out using half-ellipsoid, hemispheric and cube-shaped volumes; the volume at which the protons contained therein produced a normalized signal of 0.5 was less than 10 pl in each case. Error bars are numerical uncertainties (1σ) obtained from 10 repetitions of the Monte Carlo calculation. A.U., arbitrary units.

Extended Data Figure 4 Scaling of the NV magnetic back-action calculated as a function of the position in the NMR sample.

ad, The position-dependent back-action magnetic field in the NMR sample volume, produced by spin-polarized NV centres during CASR sensing, is calculated numerically (Supplementary Note 4). The B-field integral factors into an NV-density-dependent constant (74 nT for the present sensor) and a dimensionless, position-dependent geometric factor (colour scale). The NV magnetization is approximated as a two-dimensional Gaussian in x and y (with FWHMs of 28 μm and 20 μm, respectively) to represent the laser-intensity-dependent NV polarization, and as a step function in z (so that it is non-zero only between z = −13 μm and 0 μm) to represent the finite extent of the NV layer below the diamond surface. The geometric factor is calculated in several planes above the diamond surface, including z = 2 μm (a), z = 5 μm (b), z = 8 μm (c) and z = 10 μm (d). Even at a distance of only about 2 μm above the diamond surface, the maximum range of the geometric factor is approximately between −1 and +1. This corresponds to an approximately ±74-nT (or about ±1 p.p.m. of B0) shift in the magnetic field seen by the protons during each CASR magnetometry subsequence due to the NV centres. The back-action shift is much smaller than this magnetic-field shift in most of the measurement volume.

Extended Data Figure 5 Synchronized readout spectral resolution measured using signals from a coil antenna.

a, Power spectrum of the synchronized readout signal obtained with a single-NV magnetic sensor in a confocal microscope (Supplementary Methods 5). The synchronized readout protocol used an iteration time of τSR = 75 μs and the total experiment duration was T = SR = 112.5 s, for n = 1.5 × 106 iterations. Data shown are the average of Navg = 100 experiments. The observed spectral width was 5.2 mHz (FWHM). Independent, spectrally narrow signal sources were used to drive each of the three detected frequencies. Successive synchronized readout sequences were incoherently averaged, resulting in poor a signal-to-noise ratio compared to CASR. b, Power spectrum of the synchronized readout signal obtained with an NV-ensemble magnetic sensor. The synchronized readout protocol used an iteration time of τSR = 75 μs and the total experiment duration was T = SR = 112.5 s, for n = 1.5 × 106 iterations. The spectrum shown is for a single average (Navg = 1). The observed spectral width was again 5.2 mHz (FWHM). c, Power spectrum of the synchronized readout signal obtained with an NV-ensemble magnetic sensor. The synchronized readout protocol used an iteration time of τSR = 1.2 ms and the total experiment duration was T = SR = 3,000 s, for n = 2.5 × 106 iterations. The observed spectral width was 0.4 mHz (FWHM), substantially broader than the Fourier limit. The measured line widths for the three signals were consistent to within about 10%, suggesting that the spectral resolution in this measurement was limited by the stability of the timing source used to control the synchronized readout protocol.

Extended Data Figure 6 Spatial inhomogeneity of B0.

a, b, Transverse gradients in the magnetic bias field B0, sampled in the vicinity of the NMR measurement volume using pulsed ESR applied to the NV centres (Supplementary Methods 6). Local magnetic fields are determined by scanning the excitation laser across the diamond surface in the u direction (parallel to the diamond face, along the line with maximum projection on the cylindrical axis of the magnet poles; a) and the v direction (parallel to the diamond face, along the line perpendicular to the magnet axis; b). NV-ensemble ESR spectra were recorded at each scan position and the scan was repeated three times (n = 3). Error bars were estimated by computing the standard error in the mean of magnetic-field values over the repeated measurements at each scan position. The observed magnetic-field gradient in the v direction, dB0/dv ≈ 10 μT mm−1, is expected to yield a FNP spectral signal width of about 8.5 Hz (or about 2.3 p.p.m.) for the NMR measurement volume of diameter about 20 μm. This value is consistent with the observed FNP line widths of 8–10 Hz for water (Fig. 2c).

Extended Data Figure 7 Calculated and measured ethyl formate spectra.

a, Measured and calculated CASR NMR power spectra (offset for clarity) of ethyl formate at B0 = 88 mT. The blue trace is the original measurement, reproduced from Fig. 3c. The grey trace is a second measurement, carried out under the same conditions and with a fresh sample, to verify repeatability. The red trace is the calculated spectrum (Supplementary Note 8), obtained using the molecular parameters measured in bulk NMR at high field. b, High-field (reference proton frequency fref = 500 MHz) NMR amplitude spectra of ethyl formate. Spectral constants extracted from these data were used to calculate the low-field spectrum in a. The top-left panel shows the full spectrum; the other panels show zoomed-in regions of the spectrum corresponding to one chemical-shift group. The blue circles are the recorded data; the red lines are fits to sums of Lorentzian line shapes used to extract the molecular parameters. Because the expected triplet for the isolated proton (group III) is unresolved, we used the largest J-coupling consistent with the data. The dotted grey lines show the underlying triplet line shapes.

Extended Data Figure 8 Comparison of NV-ensemble CASR to micrometre-scale inductive NMR detector technologies.

Figure adapted from ref. 33 with permission of The Royal Society of Chemistry (https://doi.org/10.1039/C2SM26065D). Two additional inductive NMR data points from more recent studies have also been included25,34. The limit of detection is defined as the minimum number of nuclear spins in the sample volume needed to obtain a signal-to-noise ratio of 3 in 1 s of averaging. The sensitivity of the inductive detectors is scaled to a common bias field of B0 = 14.1 T, according to the convention of ref. 33. The CASR NMR sensitivity for our experiments (large red square) is calculated from the glycerol FNP measurements at B0 = 0.088 T, without scaling the bias field. Projected CASR sensitivities (small red squares) are calculated for both the 10-pl measurement volume at B0 = 3 T and a scaled-up sensor with a measurement volume of about 10 nl (Supplementary Note 9), also at B0 = 3 T. Realizing NV-ensemble CASR measurements at even higher bias fields would be very challenging technically owing to the large NV Rabi frequencies required; we therefore do not extrapolate CASR NMR to B0 = 14.1 T for this comparison.

Related audio

Supplementary information

Supplementary Information

This file contains Supplementary Methods, Notes and Data Sections 1-10 and Supplementary References. (PDF 982 kb)

PowerPoint slides

Source data

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Glenn, D., Bucher, D., Lee, J. et al. High-resolution magnetic resonance spectroscopy using a solid-state spin sensor. Nature 555, 351–354 (2018). https://doi.org/10.1038/nature25781

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1038/nature25781

This article is cited by

Comments

By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.

Search

Quick links

Nature Briefing

Sign up for the Nature Briefing newsletter — what matters in science, free to your inbox daily.

Get the most important science stories of the day, free in your inbox. Sign up for Nature Briefing