Introduction

Biological or medical detection by using reliable fluorescence materials as a probe has attracted growing attention in recent years because it can effectively sense the available information from the target solution within a very short time1, 2, 3, 4, 5. In recent years, upconversion-luminescence (UCL) materials have attracted increasing interest for upconversion lasers, solar cells, photocatalysis, and biological labeling and sensing6, 7, 8, 9, 10, 11, 12. Compared with traditional single-photon-excited fluorescence materials, such as semiconductor quantum dots and organic fluorophores, UCL materials exhibit numerous advantages for potential applications in a luminescent biosensor, including high sensitivity, minimum photodamage to living organisms, weak auto-fluorescence, etc13, 14, 15, 16. Among the UCL nanomaterials, NaYF4 nanoparticles (NPs) co-doped with trivalent lanthanide ions (Ln3+) are regarded as the most promising. This is because the Yb3+ ions serve as a sensitizing agent to hold multiple near-infrared photons that then transfer to the luminescence center of neighboring Er3+ (or Tm3+) ions, resulting in efficient light emission in the visible region17, 18, 19, 20, 21. Although the Ln3+ co-doped NaYF4 NPs that have high surface areas can be easily dispersed in the liquid phase to initiate the UCL biodetection due to the fluorescence resonance energy transfer (FRET) between the upconversion-luminescence nanoparticle (UCLNP) (donor) and the chromophores (acceptor), these particulate sensors, when suspended in a target solution, are usually unstable, irreproducible and exhibit poor processability22, 23, 24, 25, 26, 27, 28, 29. Therefore, it is important to develop a novel free-standing solid UCL sensor that possesses not only ultra-high sensitivity but also excellent recyclability and tailorability.

The assembly of individual UCLNPs into transparent polymer nanostructures to construct an inorganic/organic hybrid material on the macroscopic scale is an efficient strategy to achieve a high-performance UCL biosensor that satisfies the above required advantages. This hybrid material can integrate the properties of both the inorganic UCLNPs (two- or multi-photon absorption and anti-stokes shift behaviors) and the organic polymer (lightweight, flexibility and processability)30, 31, 32, 33. To develop the recycling characteristics, the UCLNPs should be coated with a hydrophobic polymer to avoid direct contact (or interaction) between the sensitive NPs and the chromophores in aqueous solutions. Furthermore, a micro- or nano-scale polymer coating is required to produce photon energy absorption and emission of the covered UCLNPs. The challenge for these designs is the proper choice of a fabrication method for efficient self-assembly of the UCLNPs into a desirable polymer micro- or nano-matrix and their further accumulation in the macroscopic scale for UCL detection.

Electrospinning is a facile and convenient technique to produce a polymer or related hybrid fibrous membrane (HFM) by which various types of additives ranging from tiny molecules to microscopic functional NPs can be embedded into the electrospun fiber matrix to promote their functionalization34, 35, 36, 37, 38. Herein, we used the electrospinning technique to embed the UCLNPs clusters into the transparent polystyrene (PS) nanofibers, interweaving a flexible, free-standing and tailorable HFM, in which the UCL clusters consist of NaYF4:Yb3+, Tm3+ (or Er3+) NPs with diameters of 35±10 nm. Furthermore, the rational combination of the hydrophobic chemical structure of the PS with the unique morphological structure of electrospun fibrous membrane endowed UCLNPs/PS HFM with a promising superhydrophobicity with a water contact angle of 153°. By using the as-fabricated UCLNPs/PS HFM as a free-standing solid sensor, we achieved UCL detection from a single water drop (10 μl) with an ultra-low concentration of a dye molecule (10 ppb of Rhodamine B (RhB)) and a biomolecule (1 ppb of avidin). Such ultra-low detection limits for fluorescence molecules have been not reported to date. in addition, this high-performance UCL sensor also exhibited excellent recyclability due to its superhydrophobic self-cleaning surface.

Materials and methods

Synthesis of NaYF4 NPs co-doped with Yb3+ and Er3+ ions

The NaYF4 NPs, which include 18% Yb3+ and 2% Er3+, were synthesized via the solvothermal method. During this synthesis process, a transparent mixture solution, which was labeled as solution A, was prepared firstly through dissolving 1.2 mmol of NaCl, 0.48 mmol of YCl3, 0.108 mmol of YbCl3 and 0.012 mmol of ErCl3 into a 9 ml of ethylene glycol (EG) solvent. Afterwards, the other transparent solution, which was labeled as solution B, was obtained by mixing the 3.0 mmol of NH4F and 0.006 mmol of hydrophilic polyethyleneimine (PEI) in a 6 ml of EG solvent. Subsequently, the solution A was added into the solution B to form a new mixture (precursor solution) after stirring vigorously for 10 min. This precursor solution was then sealed into a Teflon-lined autoclave with the volume of 25 ml, and kept the temperature at 200 °C for 120 min. Thus, the target sample with white color was achieved by centrifugation, cleaned with ethanol four times and N, N-dimethylformamide (DMF) twice and finally dispersed in DMF solvent.

Synthesis of NaYF4 NPs co-doped with Yb3+ and Tm3+ ions

The NaYF4 NPs, which include 20% Yb3+ and 0.2% Tm3+, were synthesized using the solvothermal method. During this synthesis process, a transparent mixture solution, which was labeled as solution A, was prepared firstly through dissolving 1.2 mmol of NaCl, 0.48 mmol of YCl3, 0.12 mmol of YbCl3 and 0.0012 mmol of TmCl3 into a 9 ml of EG solvent. Afterwards, the other transparent solution, which was labeled as solution B, was obtained by mixing the 3.0 mmol of NH4F and 0.006 mmol of PEI in a 6 ml of EG solvent. Subsequently, the solution A was added into the solution B to form a new mixture (precursor solution) after stirring vigorously for 10 min. This precursor solution was then sealed into a Teflon-lined autoclave with the volume of 25 ml, and kept the temperature at 200 °C for 120 min. Thus, the target sample with white color was achieved by centrifugation, cleaned with ethanol four times and DMF twice and finally dispersed in DMF solvent.

Fabrication of the UCL membranes

Approximately 0.4 g of PS powder (Mw=350 000) was dissolved into 5 ml of the above UCL NP/DMF solution at 50 °C (~0.08 M for the NaYF4:Yb3+, Tm3+ NPs and for ~0.1 M of the NaYF4:Yb3+, Er3+ NPs). This composite solution was then transferred to a plastic syringe for electrospinning. The applied negative voltage was fixed at 10 kV, and the collection distance was chose at 15 cm. Thus, the NaYF4:Yb3+, Tm3+ and the NaYF4:Yb3+, Er3+ NPs-embedded PS electrospun nanofibers were fabricated to produce upconversion blue emission and green emission membranes, respectively.

Characterization

The phase structures of the as-synthesized products were investigated by X-ray diffraction (XRD) technique (Cu Kα line at 0.1541 nm; XRD-6000, Shimadzu, Japan). The surface morphologies of these products were observed by a field emission scanning electron microscopy (FE-SEM) (S-4800, Hitachi, Japan), and their inner micro-structures were revealed by a transmission electron microscopy (TEM) (JEM-2100, JEOL, Japan). The optical properties of these products were detected by a Lambda 750 UV–Vis–NIR spectrophotometer (Perkin-Elmer, USA). The fluorescence spectra were recorded using a F4600 fluorimeter (Shimadzu, Japan). The water contact angles of the products were measured with a droplet analysis system (DSA100, Kruss, Germany) at five different points.

Fluorescence detection on a single water droplet

A schematic diagram of the fluorescence measurement is presented in Figure 3c in which the optical signals generated from both the UCL membrane and the detecting droplet are investigated simultaneously. The as-fabricated membrane was put onto the upside of a glass slide, and an intersection angle of 45° was maintained between this glass slide and the incident laser (980-nm diode). Then, a water droplet (10 μl) containing a certain concentration of avidin or RhB was dropped onto the membrane surface. The continuous 980-nm diode laser was used to pump the droplet position of the membrane surface, and the corresponding signal was collected using an iHR 550 spectrometer located along the vertical direction of the incident laser at a spectral resolution of 0.1 nm. All of the measurements were conducted at room temperature.

Results and discussion

The Ln3+-doped NaYF4 NPs were synthesized via a facile solvothermal method with hydrophilic PEI as the surfactant to guide the growth of the crystals, and the upconversion (UC) emission spectra were finely tuned from the visible to near-infrared region by modulating the ratios or species of the dopants (Yb3+, Tm3+ and Er3+) in the NaYF4 host lattice17. Meanwhile, the synthesized Ln3+-doped NaYF4 NPs were well-dispersed in the solvent of DMF. This provided a favorable opportunity for electrospinning of the UCLNPs/PS HM due to the good solubility of the PS polymer in the DMF solvent. Thus, the as-synthesized UCLNPs were centrifuged to remove the excess residual surfactant and solvent and then dispersed in DMF solution. To manifest strong UC emission intensity, a high concentration of Ln3+-doped NaYF4 NPs was required (~0.08 M for the NaYF4:Yb3+, Tm3+ NPs and ~0.1 M for the NaYF4:Yb3+, Er3+ NPs). Afterwards, the PS polymer, the host matrix, was also dissolved into the UCLNP-suspended solution to obtain the electrospun precursor solution. After electrospinning this viscous solution, the UCLNPs could be assembled within the PS nanofibers, which then interweaved to form a HFM. In our present work, the NaYF4:Yb3+, Tm3+ and NaYF4:Yb3+, Er3+ NP-embedded PS electrospun nanofibers were fabricated to produce blue and green UCL membranes, respectively. The UCL originated from the embedded NaYF4: Yb3+, Tm3+(Er3+) NPs, which allowed the as-electrospun HFM to be used as a UCL sensor with high sensitivity. Furthermore, because of the intrinsic nature of the PS nanofibrous framework, the free-standing HFM is also flexible and freely tailorable.

Figure 1a shows the TEM image of the as-synthesized NaYF4:Yb3+, Tm3+ NPs. The particles are spherical in shape with an average diameter of 35±10 nm. The high-resolution TEM (HRTEM) image displays a lattice fringe with a d-spacing of 0.31 nm, which corresponds to the (111) planes of the cubic NaYF4 crystal. After assembling the as-synthesized UCLNPs in the PS matrix using the electrospining technique, one-dimensional hybrid nanofibers with a diameter of 600~800 nm and a length of several tens of micrometers were fabricated (Figure 1b). Meanwhile, some of the spherical NPs were observable on the nanofiber surfaces, which may be due to a combination effect that is based on three aspects34, 35, 36, 37, 38: (1) the high viscosity of the electrospun precursor solution; (2) the high concentration of the UCLNPs in the hybrid nanofibers and (3) the fast resolidification of the PS polymer during the electrostatic drawing process. XRD patterns of the as-fabricated samples are shown in Figure 1c in which a broad peak appeared at 20° on the curve of the pure PS nanofibers, which can be ascribed to the semicrystallinity of the polymer. All of the diffraction peaks on the curve of the pure NaYF4:Yb3+, Tm3+ NPs are in agreement with the characteristic peaks of cubic NaYF4 crystals (JCPDS-77-2042), indicating the high crystallinity of the as-synthesized UCLNPs. As expected, two sets of diffraction peaks exist for the NaYF4:Yb3+, Tm3+/PS hybrid nanofibers, which correspondingly originated from the cubic NaYF4 crystals and the semicrystalline PS polymer. The as-fabricated hybrid nanofiber was further observed with TEM, and the images are shown in Figure 1d. TEM revealed that the NaYF4:Yb3+, Tm3+ NPs embedded into the PS electrospun nanofiber aggregated to form clusters with sizes between 100 and 300 nm due to the high viscosity of the electrospun precursor solution, which strongly limits the dispersion degree of the NaYF4:Yb3+, Tm3+ NPs in the DMF solution. These aggregated UCLNPs may result in an enhanced luminescence intensity compared with the dispersed NPs. The high-magnification TEM image of the red circle shown in Figure 1d demonstrates that the NaYF4:Yb3+, Tm3+ NPs on the hybrid nanofiber surface are also covered by the PS polymer with the thickness of 13 nm (Supplementary Fig. S1). The selected area electron diffraction (SAED) pattern of an individual NaYF4:Yb3+, Tm3+/PS hybrid nanofiber further confirms the crystallinity of the NaYF4-based NPs in the nanofibers. Therefore, we conclude that the NaYF4:Yb3+, Tm3+ NPs assembled into the PS electrospun nanofibers, forming a novel HFM. To generalize the model of a flexible UCL membrane, we also embedded NaYF4:Yb3+, Er3+ NPs into PS electrospun nanofibers using the same synthesis method (Supplementary Fig. S2).

Figure 1
figure 1

(a) TEM image of the as-synthesized NaYF4:Yb3+, Tm3+ NPs; the inset shows the HRTEM image of the NPs; (b) SEM image of the as-electrospun NaYF4:Yb3+, Tm3+/PS hybrid nanofibers; (c) XRD patterns of the as-fabricated samples: (a) PS nanofibers; (b) NaYF4:Yb3+, Tm3+/PS hybrid nanofibers; (c) NaYF4:Yb3+, Tm3+ NPs; (d) low and high magnification of the TEM image of an individual NaYF4:Yb3+, Tm3+/PS hybrid nanofiber and the corresponding SAED pattern.

The UCL behaviors of the as-fabricated HFMs were studied in comparison with the corresponding UCLNPs dispersed in DMF solution and the pure PS nanofibrous membrane. As shown in Figure 2a, there is no observable UCL property on the pure PS nanofibrous membrane under the excitation of 980-nm illumination. Notably, the PS film shows a high transmittance from the visible to the near-infrared region (Supplementary Fig. S3). After assembly of the NaYF4:Yb3+, Tm3+ NPs into the PS electrospun nanofibers, the HFMs exhibited a strong blue UCL when excited by a 980-nm laser diode (LD). This blue UCL is attributed to the 1G43H6 transition of Tm3+ (refs. 17, 31). Compared to the pure NaYF4:Yb3+, Tm3+ NPs, the intensity ratios of the 1I63F4, 1D23H6, 1D23F4, 1G43H6, 3F23H6 and 3F33H6 to 1G43F4 emissions decreased in the NaYF4:Yb3+, Tm3+/PS hybrid membrane. This phenomenon suggests that some vibrational transitions from the chemical bonds (or groups) of the PS polymer may interact with the excited levels of the surrounding NaYF4:Yb3+, Tm3+ NPs via a nonradiative energy transfer process, leading to changes in the UCL spectra from the corresponding energy level transitions of Tm3+ (refs. 17, 31). Based on this energy transfer process, the relative intensities of 2H11/24I15/2 and 4S3/24I15/2 to 4F9/24I15/2 that were emitted from the NaYF4:Yb3+, Er3+ NPs were significantly enhanced after coating the PS polymer (detailed analysis is provided in the supporting information, Supplementary Figs. S4 and S5). The NaYF4:Yb3+, Er3+/PS hybrid membrane displays a promoted green emission under 980-nm LD excitation (Figure 2b)31, 32. Embedding the UCLNPs into the polymer matrix effectively suppresses the local thermal effect driven by the LD excitation. This process also plays a role on promoting the UCL properties of the NaYF4 NPs, based on the cross relaxation31. When we excited the products with 980-nm LD, the blue and green light spots of a diameter of ~0.8 cm were clearly observed on the NaYF4:Yb3+, Tm3+/PS and NaYF4:Yb3+, Er3+/PS HFM surfaces, respectively (insets of Figure 2a and 2b). These observations further demonstrate the formation of UCNPs/PS HFMs, and this also provided an opportunity to implement UCL detection.

Figure 2
figure 2

(a) Normalized UC emission spectra of (a) the PS nanofibrous membrane; (b) the NaYF4:Yb3+, Tm3+/PS HFM and (c) the NaYF4:Yb3+, Tm3+ NPs dispersed in DMF solution. The insets show the corresponding optical images obtained under natural-light or 980-nm LD irradiation. (b) Normalized UC emission spectra of (a) the NaYF4:Yb3+, Er3+/PS HFM and (b) the NaYF4:Yb3+, Er3+ NPs dispersed in DMF solution. The insets show the corresponding optical images obtained under natural-light or 980-nm LD irradiation. (c) Contact angles and the corresponding optical profiles (and image) of water droplets on the different positions of the HFM surface; (d) Optical images of the tailored HFM with different morphologies.

The surface wettability of the as-electrospun HFMs was investigated using water contact angle (WCA) measurements. The WCA results and selected water droplet images that were tested on different positions of the HFM are shown in Figure 2c. All of the water droplets erect on the membrane surfaces with an average CA of ~153°, which implies that a superhydrophobic surface on the UCL membrane was constructed via the rational combination of the low surface energy of the polymer and the unique hierarchical micro-/nanostructures of the electrospun fibrous membrane. The as-electrospun UCL membrane, which is interweaved by the randomly-oriented PS nanofibers, possesses a relatively rough surface compared with the flat PS film. This may result in a decreased contact area between the water droplet and the electrospun PS membrane by trapping the air bubbles in the spaces between the interweaved PS fibers. According to the Casssie–Baxter equation39, 40, 41, 42: cosθ*=f1 cosθf2, where θ* and θ are the WCA on a flat and rough surface, respectively, and f1 and f2 are the fractions of liquid/solid and liquid/gas contact areas, for which f1+f2=1. We conclude that an electrospun membrane with a rough surface could enhance the hydrophobic property of the PS polymer by either decreasing the liquid/solid contact areas or increasing the liquid/gas contact areas. Thus, water droplets with a quasi-spherical shape can be easily aligned on the HFM surfaces with designed patterns. For example, the four letters ‘DLUN’ were patterned, as shown in Figure 2c. Using the advantage of the superhydrophobic surface, the dye or biomolecules that were dissolved in the water droplets were carried away after detection, therefore produce a self-cleaning function for the UCL membrane. In addition, as a result of the free-standing and flexible properties for the electrospun polymer membrane, we could tailor or process these membranes into arbitrary structural shapes on the macroscopic scale, such as a rectangle, zigzag forms, a cylinder, etc (Figure 2d).

Engineering and integrating the well-designed functional properties in the as-fabricated solid membrane may produce new ideas for sensing fluorescence molecules from a single water droplet. Here, we used aqueous solutions of avidin and RhB as the target liquid to evaluate the sensitive performance of the as-fabricated UCL membrane. Avidin is a common fluorescence biomolecule with a wide light-absorption band that overlaps with the UC emission spectrum of the NaYF4:Yb3+, Tm3+/PS HFM in the blue light region. Meanwhile, the absorption peak of RhB has a certain degree of overlap with the UC emission spectrum of the NaYF4:Yb3+, Er3+/PS HFM in the green light region (Figure 3a). The overlapped spectra of the UCL membrane (as the donor) and the fluorescence molecule (as the acceptor) may induce an energy transfer process via long-range dipole–dipole interactions, the so-called FRET, which will enhance the luminescence emission intensity from the fluorophore at a very low concentration24, 27, 28, 29. To fulfill this energy transfer process, another essential condition is to maintain the distance between the donor and acceptor fluorophores to within a few nanometers43, 44, 45, 46. As shown in the TEM images of the as-fabricated hybrid nanofibers (Supplementary Fig. S1), some of the UCLNPs are exposed on the nanofiber surfaces with a PS coating layer that is thinner than 3 nm. Therefore, in our case, the FRET process occurs when loading the target droplet on the surface of the as-fabricated membrane to perform the UCL detection. Upon irradiation with visible light with photon energies that are equal to the main UC emission from the UCL membranes (480 nm for the NaYF4:Yb3+, Tm3+/PS HFM and 540 nm for the NaYF4:Yb3+, Er3+/PS HFM), the photoluminescence (PL) bands for the aqueous solution of avidin and RhB should be ~525 and 610 nm, respectively (Figure 3b).

Figure 3
figure 3

(a) Spectral overlap between the UC emission spectra of the as-electrospun HFMs (NaYF4:Yb3+, Tm3+/PS (blue line), the NaYF4:Yb3+, Er3+/PS HFM (green line)) and the UV–Vis absorption spectra of RhB and avidin aqueous solutions; (b) emission spectra of RhB and avidin aqueous solutions upon excitation at 480 and 540 nm; (c) schematic diagram of the fluorescence measurement on the single water droplet; (d) normalized UC emission spectra of the NaYF4:Yb3+, Tm3+/PS HFM loaded with a single water droplet containing different concentrations of avidin; (e) normalized UC emission spectra of the NaYF4:Yb3+, Er3+/PS HFM loaded with a single water droplet containing different concentrations of RhB; (f) the integrated luminescence intensities of avidin and RhB aqueous solution versus their corresponding concentration changes.

Based on the above results and analyses, we conducted fluorescence sensing tests on a single water droplet containing trace amounts of fluorescence molecules by using the as-fabricated UCL membranes as the sensors. The schematic diagram of the fluorescence measurement is presented in Figure 3c in which the optical signals generated from both the UCL membrane and the detecting droplet are detected simultaneously. As observed in Figure 3d, upon excitation of the avidin droplet-loaded NaYF4:Yb3+, Tm3+/PS HFM with the 980-nm LD, a new PL emission band at ~530 nm emerged in the emission spectrum in comparison with that of the pure NaYF4:Yb3+,Tm3+/PS HFM. Furthermore, by increasing the avidin concentration in the water droplet, the blue thulium emission centered at 480 nm decreased gradually, and the avidin emission peak at ~530 nm increased accordingly. No emission from either avidin or RhB was observed under 980-nm irradiation because there is almost no light absorption in this wavelength region for these fluorophores. Thus, the feature fluorescence group of the avidin molecule in the water droplet absorbed the photon energy in the blue region that was generated from the 980-nm-excited NaYF4:Yb3+, Tm3+/PS HFM that overlapped with its absorption spectrum. It then emitted lower-energy green-light photons via a down-conversion luminescence process. Thus, we easily sensed relevant bioluminescence information from a target droplet by detecting variations in the fluorescence intensities using the UCL membrane as a free-standing solid sensor. To further strengthen this conclusion, we detected a water droplet containing different concentrations of RhB by using the NaYF4:Yb3+, Er3+/PS HFM under irradiation of 980 nm. As expected, the characteristic fluorescence band of RhB that centered at ~610 nm was observable in the emission spectrum of the UCL membrane. Meanwhile, this emission band increased gradually with the RhB concentration, which was accompanied by the decrease in the green erbium emission centered at 540 nm (Figure 3e). Thus, based on the FRET process between the UCL membrane donor and the fluorescence molecule acceptor, UCL detection on a single water droplet was successfully achieved using the as-fabricated HFM sensor. Notably, this new sensor exhibited not only an excellent linear relationship between the luminescence intensity (detecting the emission peak at 530 and 610 nm for avidin and RhB, respectively) and the concentration of the target fluorescence molecules (Figure 3f) but also at ultra-low detection limits (or ultra-high sensitivity), such as at 1 ppb for avidin and 10 ppb for RhB. However, it is difficult to detect the available information from the fluorescent molecule solution with a concentration that is equal to the above values by using pure UCLNPs as the sensors (Supplementary Fig. S6). Therefore, after strategic integration of the UCLNPs into the PS electrospun fibrous membrane that had unique hierarchical micro-/nanostructures, the sensing performance on the fluorescence molecules was significantly improved. The detection limits are lower than most of the reported limit concentrations detected by other types of fluorescent sensors that are based on UCL materials (Table 1).

Table 1 Structure and detection parameters of the UC fluorescent sensors

To determine the influence of the FRET process on the UCL detection more clearly, a control experiment was implemented in which the NaYF4:Yb3+,Tm3+/PS HFM was used as the sensor to detect the RhB droplet. The results show that a characteristic fluorescence band that belongs to the RhB molecule appears on the emission spectrum of the NaYF4:Yb3+, Tm3+/PS HFM under 980-nm irradiation. Meanwhile, the luminescence intensity is still dependent on the concentration changes of the RhB droplet and inversely proportional to the intensity of the 1G43H6 emission band of the Tm3+ ion, which peaked at 480 nm (Supplementary Fig. S7). There is no FRET process between the NaYF4:Yb3+,Tm3+/PS HFM and the RhB molecules due to their mismatched spectral characteristics, as shown in Figure 3a. Therefore, the higher-energy blue photons emitted from the NaYF4:Yb3+,Tm3+/PS HFM under excitation of 980 nm can induce interband transitions of the RhB molecules, resulting in the emission of lower-energy photons at ~610 nm, according to the stokes shift rule. Further investigation found that the RhB emission peak shifted gradually towards the longer wavelength side with increasing concentration (Supplementary Fig. S7). This can be attributed to the reabsorption effect of the dye47. However, when the concentration of RhB was lower than 10 ppm in the water droplet, no trace of fluorescence emission related to the RhB was detected in the spectrum. The above observation demonstrates that the detection limit (or the sensitivity) of the UCL membrane on the water droplet increased (or decreased) in the absence of a FRET process between the UCL membrane and the fluorescence molecules.

For a traditional liquid-based detection system, a UCL nanocrystal sensor suspended in the target solution is easily contaminated or lost during the detecting process, which is the main drawback that limits its recyclability28, 29. Thus, the development of a novel solid-based detection system with excellent recyclability is desirable. This may lead to new applications for UCL sensors in the fields of biological or medical detection. To evaluate the recyclability of the as-fabricated UCL membrane, we conducted an in situ spectral measurement on the NaYF4:Yb3+, Tm3+/PS HFM loaded with the avidin and RhB droplet alternately. As mentioned, the photon energy, which is emitted from the NaYF4:Yb3+, Tm3+/PS HFM by up-converting the near-infrared photon at 980 nm, is higher than the energy required to excite the interband transitions of both avidin and RhB. Thus, the characteristic fluorescence band of either the avidin or RhB droplet should be detected by using the NaYF4:Yb3+, Tm3+/PS HFM. As shown in Figure 4a, the clean NaYF4:Yb3+, Tm3+/PS HFM exhibits a classic UC emission spectrum of Tm3+ ions upon irradiation at 980 nm. When an avidin droplet (10 ppm) was loaded onto the HFM surface with the position at P1, the avidin emission peak at ~525 nm appeared, and the blue thulium emission centered at 480 nm decreased accordingly (Figure 4b). After removal of this avidin droplet via pipette, the emission spectrum of the NaYF4:Yb3+, Tm3+/PS HFM was restored to the characteristic emission profile of the 980-nm-excited Tm3+ (Figure 3c). Meanwhile, the corresponding optical image indicates the self-cleaning property of the superhydrophobic membrane sensor (inset in Figure 3c). Interestingly, upon injecting another droplet containing RhB (10 ppm) on the P1 position of the NaYF4:Yb3+, Tm3+/PS HFM, the characteristic fluorescence band of RhB was observed without any noise. Correspondingly, the luminescence intensity of the 1G43H6 transition of Tm3+ significantly decreased (Figure 4d). Thus, we conclude that this high-sensitive UCL membrane sensor exhibits excellent recyclability, which has not been achieved using traditional liquid-based detection systems. Moreover, by using this type of flexible and free-standing UCL membrane (for example, NaYF4:Yb3+, Tm3+/PS HFM) as the sensor, the pH of the single droplet can be extracted by detecting the spectral evolution on the characteristic fluorescent peak of RhB. Generally, some functional groups in dye molecules, such as the carboxylic group in RhB, can be protonated in solution. We can therefore change the fluorescence characteristics of dye molecules according to the concentration of dissociative H+ (refs. 48, 49). As shown in Figure 4e, upon increasing the pH in the target droplet, the fluorescence peak position of the RhB molecule gradually blue shifts. Further investigation indicates a good linear relation between the fluorescence peak position of the RhB molecule and the pH of the water droplet (Figure 4f), suggesting reliable performance for the UCL membrane sensor. Overall, this type of flexible, free-standing and superhydrophobic UCL membrane possesses ultra-high sensitivity, good linearity and excellent recyclability for biological or medical detection on a single droplet. In addition, single droplet detection can significantly save the consumption of a target solution during UCL biodetection, which is far more advanced than traditional liquid-based detection systems that require a large amount of target solution.

Figure 4
figure 4

In situ UC emission spectra and the corresponding optical image of (a) the NaYF4:Yb3+, Tm3+/PS HFM; (b) the NaYF4:Yb3+, Tm3+/PS HFM loaded with a single avidin droplet; (c) the NaYF4:Yb3+, Tm3+/PS HFM after removal of the above avidin droplet via pipette and (d) the NaYF4:Yb3+, Tm3+/PS HFM loaded with a single RhB droplet; (e) spectral evolution on the normalized UC emission of the NaYF4:Yb3+, Tm3+/PS HFM loaded with RhB droplets at different pHs; (f) the emission peak positions of RhB versus the corresponding pHs changes in the RhB droplet.

Conclusions

We developed a novel solid state UCL biosensor that was fabricated by embedding UCLNP clusters into a transparent PS nanofibrous-matrix to form a flexible, free-standing and tailorable HFM. The PS-covered clusters consisted of NaYF4:Yb3+, Tm3+ (or Er3+) NPs that contributed to the UCL property of the as-electrospun HFM. Moreover, the rational combination of the low surface energy of the polymer PS and the unique hierarchical micro-/nanostructures of the electrospun fibrous membrane results in superhydrophobicity for this UCL membrane. These advantages make this hybrid nanomaterial a high-performance UCL biosensor for single droplet detection. Meanwhile, this high-performance UCL sensor also exhibits excellent recyclability due to its superhydrophobic self-cleaning surface.