Abstract
Objective:
Patient care handoffs represent an important transfer of information.1, 2, 3, 4 Stand-alone electronic sign-out systems (such as Microsoft Word documents and Microsoft Access databases) require significant manual data transcription, which is a potential source of error.2 Sign-out systems integrated within a hospital's electronic medical record (EMR) have the ability to automate the retrieval of patient information from the EMR, and have been shown to facilitate handoffs.2, 5, 6, 7 To date, the customization of a commercial EMR for neonatal intensive care unit-specific handoffs has not been documented. The objective of this study was to evaluate the effect of integration of a stand-alone electronic handoff tool into the EMR on sign-out accuracy, satisfaction and workflow in a neonatal intensive care unit.
Study Design:
A prospective survey was conducted on neonatal care providers in an academic children's hospital 1 month before (n=52) and 6 months after (n=46) integration of a stand-alone Microsoft Access neonatal handoff tool into the EMR. Medical, nursing and ancillary staff usage of the EMR-integrated neonatal sign-out report was tracked systematically by the EMR itself.
Result:
Providers reported that sign-out information was somewhat or very accurate at a rate of 78% with the stand-alone handoff tool and at 91% with the EMR-integrated tool (P<0.01). Before integration of neonatal sign-out into the EMR, 35% of providers were satisfied with the process of updating sign-out information and 71% were satisfied with the printed sign-out document; following EMR integration of neonatal sign-out, 92% of providers were satisfied with the process of updating sign-out information (P<0.01) and 98% were satisfied with the printed sign-out document (P<0.01). The median percentage of total sign-out preparation time dedicated to transcribing information from the EMR was 25 to 49% before and <25% after EMR integration of the handoff tool (P<0.01). Following EMR integration, ∼25% of neonatal sign-out usage was by nursing staff and over 10% of usage was by ancillary staff.
Conclusion:
Integration of a neonatal intensive care unit-specific handoff tool into an EMR resulted in improvements in perceived sign-out accuracy, provider satisfaction and workflow. EMR integration of the handoff tool also resulted in increased access to and communication of sign-out information to nursing and ancillary staff. Customization of commercially available EMRs to meet the unique demands of the neonatal intensive care unit is possible; we showed specifically the potential to improve handoff communication, an important aspect of patient safety.
This is a preview of subscription content, access via your institution
Access options
Subscribe to this journal
Receive 12 print issues and online access
$259.00 per year
only $21.58 per issue
Buy this article
- Purchase on Springer Link
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout
References
Mukherjee S . A precarious exchange. N Engl J Med 2004; 351: 1822–1824.
Frank G, Lawless ST, Steinberg TH . Improving physician communication through an automated, integrated sign-out system. J Healthc Inf Manag 2005; 19: 68–74.
Institute of Medicine (U.S.). Committee on Quality of Health Care in America. Crossing the Quality Chasm: A New Health System for the 21st Century. National Academy Press: Washington, DC, 2001.
The Joint Commission 2006 Critical Access Hospital and Hospital National Patient Safety Goals. 2006 [cited]Available from: http://www.jointcommission.org/GeneralPublic/NPSG/06_npsg_dsc.htm.
Van Eaton EG, Horvath KD, Lober WB, Pellegrini CA . Organizing the transfer of patient care information: the development of a computerized resident sign-out system. Surgery 2004; 136: 5–13.
Van Eaton EG, McDonough K, Lober WB, Johnson EA, Pellegrini CA, Horvath KD . Safety of using a computerized rounding and sign-out system to reduce resident duty hours. Acad Med 2010; 85: 1189–1195.
Sidlow R, Katz-Sidlow RJ . Using a computerized sign-out system to improve physician-nurse communication. Jt Comm J Qual Patient Saf 2006; 32: 32–36.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Competing interests
The authors declare no conflict of interest.
Rights and permissions
About this article
Cite this article
Palma, J., Sharek, P. & Longhurst, C. Impact of electronic medical record integration of a handoff tool on sign-out in a newborn intensive care unit. J Perinatol 31 (Suppl 1), S83–S84 (2011). https://doi.org/10.1038/jp.2010.184
Published:
Issue Date:
DOI: https://doi.org/10.1038/jp.2010.184
Keywords
This article is cited by
-
Neonatal intensive care unit handoffs: a pilot study on core elements and epidemiology of errors
Journal of Perinatology (2014)