Abstract
Fine particles in hospitality venues with insufficient smoking bans indicate health risks from passive smoking. In a random sample of Viennese inns (restaurants, cafes, bars, pubs and discotheques) effects of partial smoking bans on indoor air quality were examined by measurement of count, size and chargeable surface of ultrafine particles (UFPs) sized 10–300 nm, simultaneously with mass of particles sized 300–2500 nm (PM2.5). Air samples were taken in 134 rooms unannounced during busy hours and analyzed by a diffusion size classifier and an optical particle counter. Highest number concentrations of particles were found in smoking venues and smoking rooms (median 66,011 pt/cm3). Even non-smoking rooms adjacent to smoking rooms were highly contaminated (median 25,973 pt/cm3), compared with non-smoking venues (median 7408 pt/cm3). The particle number concentration was significantly correlated with the fine particle mass (P<0.001). We conclude that the existing tobacco law in Austria is ineffective to protect customers in non-smoking rooms of hospitality premises. Health protection of non-smoking guests and employees from risky UFP concentration is insufficient, even in rooms labeled “non-smoking”. Partial smoking bans with separation of smoking rooms failed.
This is a preview of subscription content, access via your institution
Access options
Subscribe to this journal
Receive 6 print issues and online access
$259.00 per year
only $43.17 per issue
Buy this article
- Purchase on Springer Link
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout
Similar content being viewed by others
References
Daly BJ, Schmid K, Riediker M . Contribution of fine particulate matter sources to indoor exposure in bars, restaurants, and cafes. Indoor Air 2010; 20: 204–212.
Huss A, Kooijman C, Breuer M, Böhler P, Zünd T, Wenk S et al. Fine particulate matter measurements in Swiss restaurants, cafes and bars: what is the effect of spatial separation between smoking and non-smoking areas? Indoor Air 2010; 20: 52–60.
Bolte G, Heitmann D, Kiranoglu M, Schierl R, Diemer J, Koerner W et al. Exposure to environmental tobacco smoke in German restaurants, pubs and discotheques. J Expo Sci Environ Epidemiol 2008; 18: 262–271.
Demkowska I, Polkowska Z, Namiesnik J . Non-invasive biological fluid matrices analysed to assess exposure to environmental tobacco smoke. J Expo Sci Environ Epidemiol 2011; 21: 656–661.
Simkhovich BZ, Kleinman MT, Kloner RA . Particulate air pollution and coronary heart disease. Curr Opin Cardiol 2009; 24: 604–609.
Franck U, Odeh S, Wiedensohler A, Wehner B, Herbarth O . The effect of particle size on cardiovascular disorders—the smaller the worse. Sci Total Environ 2011; 409: 4217–4221.
Neuberger M, Rabczenko D, Moshammer H . Extended effects of air pollution on cardiopulmonary mortality in Vienna. Atmospheric Environ 2007; 41: 8549–8556.
Ellingsen DG, Fladseth G, Daae HL, Gjølstad M, Kjaerheim K, Skogstad M et al. Airborne exposure and biological monitoring of bar and restaurant workers before and after the introduction of a smoking ban. J Environ Monit 2006; 8: 362–368.
Goodman P, Agnew M, McCaffrey M, Paul G, Clancy L . Effects of the Irish smoking ban on respiratory health of bar workers and air quality in Dublin pubs. Am J Respir Crit Care Med 2007; 175: 840–845.
Gorini G, Moshammer H, Sbrogiò L, Gasparrini A, Nebot M, Neuberger M et al. Italy and Austria before and after study: second-hand smoke exposure in hospitality premises before and after 2 years from the introduction of the Italian smoking ban. Indoor Air 2008; 18: 328–334.
Pell JP, Haw S, Cobbe S, Newby DE, Pell AC, Fischbacher C et al. Smoke-free legislation and hospitalizations for acute coronary syndrome. N Engl J Med 2008; 359: 482–491.
Pletz H, Neuberger M . No borders for tobacco smoke in hospitality venues in Vienna. Atmosphere 2011; 2: 171–181.
Moshammer H, Neuberger M, Nebot M . Nicotine and surface of particulates as indicators of exposure to environmental tobacco smoke in public places in Austria. Int J Hyg Environ Health 2004; 207: 337–343.
Terzano C, Di Stefano F, Conti V, Graziani E, Petroianni A . Air pollution ultrafine particles: toxicity beyond the lung. Eur Rev Med Pharmacol Sci 2010; 14: 809–821.
Asbach C, Fissan H, Stahlmecke B, Kuhlbusch TA, Pui DY . Conceptual limitations and extensions of lung-deposited nanoparticle surface area monitor (NSAM). J Nanoparticle Res 2009; 11: 101–109.
120. Bundesgesetz: Änderung des Tabakgesetzes, des Allgemeinen Sozialversicherungsgesetzes, des Gewerblichen Sozialversicherungsgesetzes und des Bauern-Sozialversicherungsgesetzes. Bundesgesetzblatt, 2008. Retrieved September 20, 2012 at http://www.ris.bka.gv.at/Dokumente/BgblAuth/BGBLA_2008_I_120/BGBLA_2008_I_120.pdf.
Fierz M MiniDiSC Factsheet. Institute for Aerosol and Sensor Technology. Retrieved September 20, 2012 at http://fierz.ch/minidisc/.
Grimm Aerosol Technik GmbH & Co. KG. Umweltstaubmessgeräte. Retrieved September 2, 2012 at http://www.grimm-aerosol.com/de/.
Neuberger M, Moshammer H . Das österreichische Tabakgesetz und die Luftqualität in der Gastronomie. Atemw Lungenkrht 2012; 38: 8–11.
Wallace L, Ott W . Personal exposure to ultrafine particles. J Expo Sci Environ Epidemiol 2011; 21: 20–30.
World Health Organisation. Air quality guidelines for particulate matter, ozone, nitrogen dioxide and sulfur dioxide—global update. WHO Press: Geneva, Switzerland. 2005 p 279.
U.S. Environmental Protection Agency National ambient air quality standards. Retrieved September 20, 2012 at http://www.epa.gov/air/criteria.html.
Smolle-Jüttner FM . Rauchverbot ohne Kompromisse ist der einzige Weg aus der Misere. Wien Klin Wochenschr 2009; 121: 486–490.
Rockenbauer R Untaugliches Tabakgesetz. WKO blockiert Umsetzung wirkungsvoller Nichtraucherschutzbestimmungen. Retrieved September 20, 2012 from http://alpha2000.at/nichtraucher/monatsthemen/2009-01-2-untaugliches.html.
The Gallup Organisation Survey on Tobacco. Analytical Report 2009. Flash Eurobarometer 253. Retrieved September 20, 2012 from http://ec.europa.eu/public_opinion/flash/fl_253_en.pdf.
Gasser MA . Risikobewusstsein und Belästigung durch Tabakrauch bei Aktiv- und PassivraucherInnen in der Wiener Gastronomie. Diploma Thesis, Medical University of Vienna, Austria. 2012.
Schwarz K . Rauchverhalten und Einstellung zum Tabakgesetz bei LokalbesucherInnen in Wien, im Vergleich zu internationalen Erhebungen. Diploma Thesis, Medical University of Vienna, Austria. 2011.
Koch P . Beurteilung der Tabakgesetznovelle (Rauchergesetz“) durch Kunden gastronomischer Betriebe in der Steiermark. Diploma Thesis, Graz Medical University, Austria. 2009.
Hutgrabner CS . Geschlechtsspezifische Differenzen in der Akzeptanz der Tabakgesetznovelle. Diploma Thesis, Graz Medical University, Austria. 2010.
Reichmann G, Sommersguter-Reichmann M . The Austrian Tobacco Act in practice—analysing the effectiveness of partial smoking bans in Austrian restaurants and bars. Health Policy 2012; 104: 304–311.
International Agency for Research on Cancer Smoke-free policies effective. IARC 2008, Press Release No.189. Retrieved September 20, 2012 at http://www.iarc.fr/en/media-centre/pr/2008/pr189.html.
Erazo M, Iglesias V, Droppelman A, Acuña M, Peruga A, Breysse PN . Secondhand tobacco smoke in bars and restaurants in Santiago, Chile: evaluation of a partial smoking ban legislation in public places. Tob Control 2010; 19: 469–474.
López MJ, Nebot M, Schiaffino A, Pérez-Ríos M, Fu M, Ariza C et al. Two-year impact of the Spanish smoking law on exposure to secondhand smoke: evidence of the failure of the Spanish model. Tob Control 2012; 21: 407–411.
Pacheco SA, Aguiar F, Ruivo P, Proença MC, Sekera M, Penque D et al. Occupational exposure to environmental tobacco smoke: a study in Lisbon restaurants. Toxicol Environ Health A 2012; 75: 857–866.
Moshammer H, Neuberger M . The active surface of suspended particles as a predictor of lung function and pulmonary symptoms in Austrian school children. Atmospheric Environ 2003; 37: 1737–1744.
Oberdörster G, Oberdörster E, Oberdörster J . Nanotoxicology: an emerging discipline evolving from studies of ultrafine particles. Environ Health Perspect 2005; 113: 823–839.
Acknowledgements
Special thanks to Viktoria Slavik for assistance in sampling and to the Vienna municipality (department 22) for providing ambient air data. The project has been funded by the Clean Air Commission of the Austrian Academy of Sciences, based on contract No 14 4440/45-I/4/98 with the Ministry for the Environment, Youth and Family Affairs and the Ministry for Science and Traffic.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Competing interests
The authors declare no conflict of interest.
Rights and permissions
About this article
Cite this article
Neuberger, M., Moshammer, H. & Schietz, A. Exposure to ultrafine particles in hospitality venues with partial smoking bans. J Expo Sci Environ Epidemiol 23, 519–524 (2013). https://doi.org/10.1038/jes.2013.22
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/jes.2013.22
Keywords
This article is cited by
-
Outdoor ultrafine particle concentrations in front of fast food restaurants
Journal of Exposure Science & Environmental Epidemiology (2016)