Introduction

Trabeculectomy is the most commonly performed incisional procedure for intraocular pressure (IOP) reduction in glaucoma patients. Its success rate and complications are well established.1, 2 Short-term complications after trabeculectomy include anterior chamber shallowing, hypotony, and choroidal detachment. Long-term complications include bleb leaks, blebitis/endophthalmitis, overhanging blebs, and bleb failure. These potential complications threaten vision thereby demonstrating the need for safer surgical procedures to manage glaucoma. In recent years several alternative procedures have been evaluated and compared to trabeculectomy.1, 2, 3, 4, 5

The Ex-PRESS glaucoma filtration device (Alcon Laboratories, Fort Worth, TX, USA) was developed as an alternative to trabeculectomy, and shows similar IOP reduction with fewer complications. Its original design required insertion under a conjunctival flap through the full scleral thickness. This procedure led to unacceptable hypotony rates in the immediate postoperative stage and medium-term erosion of the device through the conjunctiva.6, 7, 8, 9, 10, 11, 12 Dahan and Carmichael13 addressed these issues by placing the device under a partial-thickness scleral flap. The original sub-conjunctival placement has now been completely abandoned for a safer implantation under a scleral flap.13, 14, 15, 16, 17, 18, 19, 20 The latter procedure closely resembles trabeculectomy, but offers the advantages of a standard (stented) sub-scleral outflow route that obviates sclerostomy and peripheral iridectomy.

Until now, data comparing safety and efficacy of standard trabeculectomy vs Ex-PRESS implantation under a scleral flap were mostly retrospective and the procedures have been evaluated in eyes with diverse types of glaucoma.14, 15, 18, 20 In this report we describe the results of a prospective, randomised study in patients with bilateral primary open-angle glaucoma (POAG) only, where both procedures (one per eye) were compared in fellow eyes of the same patient.

Patients and methods

Study design and surgical technique

Patients with bilateral POAG underwent standard trabeculectomy in one eye and Ex-PRESS implantation under a scleral flap in the other eye, according to a prospective and randomised design.

Eligible patients were at least 18 years of age and presented with medically uncontrolled POAG requiring bilateral incisional surgery for IOP reduction. Patients with prior cataract operation or failed filtration surgery in either eye were eligible if surgery took place at least 3 months prior to enrolment. Patients meeting any of the following criteria were excluded: any form of glaucoma other than POAG; history of active uveitis; and any ocular abnormality that would preclude accurate IOP assessment.

The study was conducted in accordance with the tenets of the Declaration of Helsinki. All participating patients provided written informed consent. The study was approved by the Ethics Committee of the Medical School at the University of the Witwatersrand, Johannesburg, South Africa. The trial is registered at http://www.clinicaltrials.gov (unique registration number: NCT00698438).

After consent was given, patients’ preoperative baseline data were collected, including demographics, ocular history, visual acuity, applanation tonometry, slit-lamp biomicroscopy, and ophthalmoscopy. Randomisation of contralateral operations was achieved by opening an envelope in which the procedure (trabeculectomy or Ex-PRESS implantation) that would be applied to the first eye was stated, thereby determining the procedure in the other eye.

After sub-tenonian local anaesthesia, surgery was performed by one experienced surgeon (ED), for consistency, using a standardised technique for both procedures. In all cases a 25G anterior chamber maintainer (ACM), connected to a bottle of balanced salt solution (BSS), was inserted into the limbus at the lower temporal quadrant to maintain positive IOP throughout the operation. A fornix-based conjunctival flap was created with a relaxing incision on one side. Next, a 50% thickness trapezoidal scleral flap (5 × 5 × 1 mm) was constructed and advanced anteriorly into the clear cornea. Then, for all patients a wound-modulating agent (mitomycin C 0.05%) was applied to the scleral bed for 1 min. For trabeculectomy a 1.5 × 1-mm posterior lip sclerectomy was fashioned with a 15 degree surgical blade under the scleral flap, at the grey limbal zone between the white sclera and the clear cornea, and a peripheral iridectomy was created. For eyes randomised to Ex-PRESS, the Ex-PRESS X200 model, designed for implantation under a scleral flap, was selected. This model slightly differs from the original Ex-PRESS R50 version designed for implantation under the conjunctiva because it has a slitted flange, total 2.4 mm length, a rounded tip, a square body, and a 200-μm micron lumen. Ex-PRESS X200 was implanted with a 23-G needle held parallel to the iris, to produce a pre-incision under the scleral flap, through the grey zone, and into the anterior chamber. Mobility of the Ex-PRESS device on its introducer was confirmed before the device was implanted through the needle track. Closure was identical with both procedures. The scleral flap was closed with five interrupted 10-0 nylon sutures (one suture at the apex and two at each side of the scleral flap). Water tightness was verified by allowing the BSS fluid to ooze out very slightly near the apex of the trapezoidal scleral flap with the bottle positioned 50 cm above the patient's head. The conjunctiva was closed with two 10-0 nylon sutures tacking down both ends of the peritomy. In all cases, at the end of surgery the anterior chamber was filled with standard-viscosity, viscoelastic material (Healon, Provisc) via the paracentesis port created for the ACM. Following surgery, eyes were initially treated with a steroid/antibiotic combination ( × 4 daily) for 2 weeks and thereafter with a non-steroidal, anti-inflammatory drug (Diclofenac 0.1% × 3 daily) for 8 weeks. During the early postoperative period, hypertony (≥27 mm Hg) was treated with A/C decompression using the ACM paracentesis port if it occurred during the first week postoperatively. Scleral flap suture cutting was performed if hypertony occurred later. Patients were evaluated after surgery on days 1 and 7, at months 1, 3, 6, 9 and 12, and at 6-monthly intervals thereafter. The following items were assessed, at each visit: surgical complications, IOP, visual acuity, and number of medicines needed to achieve adequate IOP control.

Data analysis

Power

The study sample size (n=30, ie, 15 eyes with each procedure) provided 96% power to detect an average IOP difference of 2.0 mm Hg between eyes (average IOP, 14 (±2.5) vs 16.5 mm Hg (±2.5), with a follow-up correlation of 0.25 between eyes that underwent Ex-PRESS implantation vs trabeculectomy), based on the planned number of measurements (ie, 7) starting at 1 month after surgery. The study had 84% power to detect an average difference of 1.6 mm Hg and 79% power to detect an average IOP difference of 1.5 mm Hg. Power calculations were based on a type-I α error of 0.05 and two-sided tests.

Statistical analysis

Wilcoxon matched-pairs t-test (within patients) was used to compare pre-operative and final IOP values, and the number of glaucoma medicines.

A Generalised Estimating Equation (GEE) model21 was used to analyse the time trend of the average IOP difference between eyes receiving randomised treatments, from 1 month after surgery to the end of the follow-up period (30 months). All available IOP follow-up data at days 1 and 7, and months 1, 3, 6, 9, 12, 18, 24 and 30 were analysed. The study was specifically designed to satisfy such a model. GEE models allow individual IOP correlations over time, as these may differ between patients. Also, fractional polynomials22, 23 were incorporated to adjust for postoperative time effects. Fractional polynomials enable a flexible strategy, modelling both linear and non-linear effects arising with continuous variables (in the present case, effects of time from 1 month following surgery). The estimated average IOP difference between procedures over time was then plotted with its 95% confidence interval (CI). The power of both the study and the GEE model were estimated using Stata version 11 (Stata Corp., College Station, TX, USA).

A Cox survival model was used to compare clinical failure between procedures. Complete success was defined as IOP>5 mm Hg and <18 mm Hg without glaucoma medication. Qualified success was defined as IOP>5 mm Hg and <18 mm Hg with or without glaucoma medication. To take into account the correlation between an individual patient's eyes, a robust estimate of the variance was calculated using a Jack-Knife estimator, as recommended by Therneau and Grambsch24 and implemented in the ‘R survival package’ (R version 2.11.1, Survival Package Version 2.36-2).25, 26 Cross-tabulations using MacNemar's χ2-test were used to calculate the proportion of complications with each procedure (trabeculectomy vs Ex-PRESS). Other statistical tests included Wilcoxon matched paired t-test, Fisher's exact test, and Kaplan–Meier survival analyses.

Results

Thirty eyes of 15 patients with bilateral POAG were included in the study. They comprised 10 males and 5 females with mean age 65.4 (±13.7) years. Six patients were black, 5 Indian, 3 Caucasian, and 1 mixed. All patients suffered from advanced bilateral POAG. Baseline glaucoma severity was similar in each eye pair, with a mean cup disk ratio ≥0.85 for both groups. Pre-operatively, mean IOP was 29.6 mm Hg (±11.8) for all 30 eyes, distributed as 31.1 mm Hg (±14.2) for 15 trabeculectomy eyes and 28.1 mm Hg (±9.0) for 15 Ex-PRESS eyes (P=0.484), after randomisation. Glaucoma medication prior to surgery averaged 3.7 (±0.7) medical entities administered to both eyes. The 15 eyes of each group included 10 glaucoma surgery failures because 10 patients had bilateral previously failed surgery. All 15 patients were followed-up for 1 year after surgery. One patient died 13 months after surgery and two patients were subsequently lost to follow-up. All data available for these patients (ie, up to 1 year) are included in the analyses.

At the last follow-up, mean IOP values decreased significantly (paired t-test P<0.001) from their pre-operative levels, that is, trabeculectomy, from 31.1 (±14.2) mm Hg to 16.2 (±1.5) mm Hg, and Ex-PRESS, from 28.1 (±9.0) mm Hg to 15.7 (±1.8) mm Hg, thus demonstrating the efficacy of both surgical techniques. Similarly, at the last follow-up, mean anti-glaucoma medicine consumption decreased significantly (paired t-test P<0.001), from 3.7 (±0.5) pre-operatively, to 0.9 (±1.0) after trabeculectomy and 0.3 (±0.5) after Ex-PRESS. Results on evolution of IOP and number of medications in both groups are described in Figure 1.

Figure 1
figure 1

IOP (mm Hg) and number of glaucoma medicines over time according to surgical technique.

Figure 2 shows the GEE model time trend of the mean IOP difference between eyes randomised to Ex-PRESS implantation compared with trabeculectomy, from 1 month after surgery to the end of the 30-month follow-up period. The horizontal dashed line indicates no difference in IOP between procedures. The solid line with its shaded 95% CI represents a significant mean IOP difference between eyes with Ex-PRESS compared with trabeculectomy, from 3 to 24 months after surgery and no difference at 30 months.

Figure 2
figure 2

Time trend of the average difference in IOP between Ex-PRESS vs trabeculectomy eyes from 1 month after surgery to the end of follow-up (30 months). Note: For all time points in which the 95% CI (grey shaded zone) of the average difference in IOP between Ex-PRESS vs trabeculectomy eyes lies below the dashed line (difference in IOP=0), Ex-PRESS eyes had a significantly lower (better) IOP.

Kaplan–Meier survival analysis curves for complete and qualified successes are shown in Figures 3 and 4. Figure 3 depicts complete success probabilities after both trabeculectomy and Ex-PRESS implantation, with success defined as IOP>5 mm Hg and <18 mm Hg on two consecutive visits (or at the last visit) without glaucoma medication. A higher probability of success followed Ex-PRESS implantation (hazard ratio=0.27 (CI95%=(0.12; 0.60))) compared with standard trabeculectomy (P=0.0019).

Figure 3
figure 3

Survival curve with complete success defined as 5<IOP<18 mm Hg without glaucoma medication (P=0.0024).

Figure 4
figure 4

Survival curve with qualified success defined as 5<IOP<18 mm Hg with and without glaucoma medication (P=0.0124).

Figure 4 shows probabilities of qualified success (with and without glaucoma medication), yielding a hazard ratio of 0.21 (CI95%=(0.06; 0.71)) in favour of Ex-PRESS, compared with standard trabeculectomy (P=0.0124).

Patients with at least one postoperative complication during any visit are summarised in Table 1. Complications were generally mild although more frequent after trabeculectomy (33%) than after Ex-PRESS implantations (20%) (P=0.05, Fisher's exact test). Further surgical interventions were needed for four eyes (27%) in the trabeculectomy group, only (P=0.0009, Fisher's exact test). In addition, one trabeculectomy eye underwent hyphema and an Ex-PRESS eye a wound leak; these mild complications both resolved spontaneously within a week.

Table 1 Number of complications and postoperative interventions occurring at least once per patient (n=15)

Early in the postoperative course, hypotony (IOP<5 mm Hg) was more frequently observed after trabeculectomy (33%) than after Ex-PRESS implantation (7%). In all cases it resolved during the first month after either intervention. Total anterior chamber loss with iridocorneal touch or choroidal detachment was never encountered in either group. Two eyes required anterior chamber decompression for elevated IOP during the early postoperative course after trabeculectomy, but no eyes needed suture lysis. At the 1-year follow-up, one eye after trabeculectomy underwent bleb excision with advancement of healthy conjunctiva because of a high, avascular and very thin bleb. By contrast, no Ex-PRESS eye required any surgical intervention during the follow-up period.

During the follow-up period, no acceleration of cataract formation was encountered after both interventions and visual acuity remained unchanged relative to pre-operative values.

Discussion

Trabeculectomy has been the standard IOP-lowering procedure for nearly 40 years, but its potentially devastating sight-threatening complications have prompted calls for a better, safer operation.27 In recent years several new IOP-lowering procedures have been developed as alternatives to standard trabeculectomy. These include non-penetrating procedures such as deep sclerectomy with or without collagen implant, viscocanalostomy, and novel angle procedures.28 Also, glaucoma drainage devices have been developed and evaluated as primary surgical therapies for glaucoma.29

Numerous studies have reported on the biocompatibility, safety, and efficacy of the Ex-PRESS glaucoma filtration device during its evolution over the last decade.30, 31, 32, 33 The device is essentially a trans-scleral miniature tube that delivers aqueous from the anterior chamber to the sub-scleral and sub-conjunctival spaces (similar to trabeculectomy). Ex-PRESS implantation under a scleral flap may be viewed as a compromise between trabeculectomy and non-penetrating glaucoma surgery on account of the standardised flow restriction imposed by the miniature shunt. The procedure, however, is more straightforward than trabeculectomy as it does not require sclerostomy or iridectomy. This also may reduce postoperative inflammation, which is desirable after glaucoma surgery. In rabbits, levels of transforming growth factor-β (a key component of wound healing after glaucoma surgery34) were reduced in eyes after Ex-PRESS implantation, as compared with trabeculectomy (Sampson EM, ARVO abstract #52, 2005).

In the present study, trabeculectomy and Ex-PRESS outcomes were evaluated in a prospective, randomised study where each patient underwent each procedure in a different eye. Although good IOP control was achieved in both groups, mean IOP values were marginally lower from 3 months to 2 years after Ex-PRESS implantation. Furthermore, success rates were higher throughout 30 months of follow-up after Ex-PRESS. Complete success rates are probably more relevant than qualified success rates because of compliance issues, especially in our study, which included only POAG patients with advanced optic nerve damage. In addition, trabeculectomy resulted in a higher rate of postoperative complications (33%) than Ex-PRESS implants (20%), and 27% of eyes needed postoperative interventions, whereas none were needed with Ex-PRESS. These results were obtained by a single experienced glaucoma surgeon (ED) who has performed several thousands of trabeculectomies since 1981 and initiated the Ex-PRESS implantation under a scleral flap in the year 2000.

Trabeculectomy eyes had higher rates of hypotony during the immediate postoperative period than Ex-PRESS eyes. The difference in hypotony rates can be explained by the essential difference in the immediate postoperative filtration mechanism of the two procedures. The physical properties of the apertures that connect the anterior chamber to the sub-scleral space are not same in the two procedures. The aqueous flow through Ex-PRESS, which is essentially a 2.4-mm-long tube with a 200-μm lumen, is probably different from the flow through the 1.5-mm2-wide sclerectomy of the trabeculectomy even when both apertures are secured by overlying scleral flaps. Although the scleral flaps were closed with the same numbers of sutures in both groups, there is a possibility that the higher hypotony rate in the trabeculectomy group was due to occasional differences in suture tension between the two techniques.

When trabeculectomy and Ex-PRESS implantation are compared, the cost issue of the latter cannot be ignored especially in a public healthcare environment. The two procedures resulted in similar postoperative IOPs but implantation of a foreign device implies additional cost. However, the cost of Ex-PRESS might be outweighed by its benefits in terms of lower complication rates, lower postoperative intervention rates, and above all, its higher complete success rate that relieves patients from the costs of postoperative anti-glaucoma medications. It is up to the surgeon to judge when to prefer one procedure over the other according the economic situation, availability of implant and his/her judgment on the cost of postoperative anti-glaucoma medications, the hidden costs of complications, and the need for postoperative additional interventions.

Our results are in accordance with those of a prospective, comparative, randomised study by De Jong during a follow-up limited to 1 year.18 Complete success rate was 81.8% after Ex-PRESS compared with 47.5% after trabeculectomy at a 1-year follow-up. The need for postoperative interventions was 15% after trabeculectomy and 7.5% after Ex-PRESS.

Gallego-Pinazo et al15 compared Ex-PRESS implantation with trabeculectomy, in combined cataract/filtering operations with a mean follow-up of 9.7 months. They reported a significantly higher complication rate during the early postoperative course after trabeculectomy than after Ex-PRESS implantation. IOP reduction was similar in both groups, but IOP control was better after Ex-PRESS implantation, although not statistically significant. Our study yielded comparable results during a longer follow-up.

Maris et al14 performed a retrospective comparison of trabeculectomy vs Ex-PRESS implantation. As in the present study, these investigators also noted a higher rate of postoperative hypotony after trabeculectomy (32%) compared with Ex-PRESS implantation (4%). Unlike us, however, their Kaplan–Meier analysis showed no significant difference between success rates or the need for supplemental glaucoma medication. The differences between their study and ours may be partly explained by the various glaucoma types included in their study such as neovascular and uveitic glaucoma that are known to have different natural histories and worse prognoses than POAG. Furthermore, the upper IOP cut-off point for ‘success’ in their study was set at 21 mm Hg, whereas in our study it was set at <18 mm Hg. We chose this relatively low IOP cut-off point for ‘success’ because all our patients’ eyes manifested advanced POAG with cup disk ratio ≥0.85, where a low target postoperative IOP is desirable.

Good and Kahook20 reported a retrospective comparison between 35 consecutive Ex-PRESS implants and 35 consecutive trabeculectomy procedures followed up for at least 2 years. Ex-PRESS implantation yielded a 77.14% complete success rate, compared with 74.29% with trabeculectomy. Blebs with Ex-PRESS were fewer, less vascular, and more diffuse than after trabeculectomy (Moorfields Bleb Grading System), and cases of early postoperative hypotony and hyphema were fewer. Visual recovery was more rapid in eyes with Ex-PRESS. The different complete success rates, between their study and ours, may be partly explained by their inclusion of patients with chronic angle-closure glaucoma and pseudoexfoliation glaucoma, in addition to POAG. Furthermore, these two studies were retrospective and procedures were not contrasted between eyes of individual patients, as in the present report.

Severe postoperative complications were uncommon after either intervention in our study, where the standardised technique for both interventions included systematic use of an ACM. This permitted consistent control of positive intra-operative IOP, and enabled us to assess and modulate the filtration, to achieve a mild aqueous percolation at the posterior edges of the scleral flap after the scleral flap had been sutured. We also constructed a relatively large scleral flap (5 × 5 × 1 mm) to increase the area for dispersing the aqueous flow. These aspects of our technique were previously described as features conducive to safer and more effective surgical outcomes.35 Several investigators have noted a risk of central visual acuity loss after filtration surgery in eyes with advanced glaucoma.36, 37 We did not encounter this phenomenon in any eye in the present study, which seems particularly striking as all eyes studied had advanced POAG with a mean pre-operative cup disk ratio ≥0.85. It may be that our adoption of the ‘safe trabeculectomy’ technique,35, 38 with its wide scleral flap and systematic use of an ACM, was beneficial in all cases.

The major weakness of our study is its small sample size, only 30 eyes studied (15 patients), due to the relative difficulty in enrolling POAG patients who agree to undergo trabeculectomy in one eye and Ex-PRESS implantation in the other eye in a randomised manner. However, this small group was sufficient to show a statistically significant difference between procedures especially on criteria of success rates and complication rate. The validity of our findings was further strengthened by comparing the two interventions in fellow eyes of the same patient. At last, all patients had advanced POAG in both eyes, and therefore presented a uniform and homogeneous group appropriate for a well-founded comparison of the two interventions.

A lesser limitation regarding lack of masking still exists in our study. It was not possible to mask the surgical technique as trabeculectomy is easily differentiated from Ex-PRESS implantation during postoperative follow-ups. However, this limitation is overcome by the fact that all patients were followed up concurrently by their referring ophthalmologists from the first month postoperatively till completion of the study.

In summary, the present study is the first report of a prospective, randomised comparison of trabeculectomy and Ex-PRESS implantation in fellow eyes of the same patient with the longest follow-up period to date. Our results are consistent with other published reports showing that the Ex-PRESS device provides similar IOP control to trabeculectomy, with lower incidence of postoperative complications, additional interventions, or need for glaucoma medications.