Abstract
Purpose/background To assess whether loss of image resolution or colour and subsequent telemedicine transmission of digital images affects the accuracy of retinal lesion detection by ophthalmologists when compared with the original transparencies.
Methods Fifteen ophthalmologists of different experience independently scored 11 retinal images for pathological signs. The images were presented as either transparencies or colour and monochrome digital images, which had been transmitted via telephone lines to a geographically remote location. One patient's eye was also imaged using scanning laser ophthalmosocopy (SLO) which produced a dynamic black and white digital image. ANOVA analysis was performed. Results Total scores were higher for transparencies than colour (p = 0.0003) or black and white digital images (p = 0.00006). Expert observers (n = 5) considered separately showed no significant difference of accuracy between transparencies and either colour digital (p = 0.09) or monochrome digital images (p = 0.11). Experts were better than trainees at detecting pathology from less familiar images: total score (p = 0.02), colour digital (p = 0.03), monochrome digital (p = 0.02) and SLO images (p = 0.004). Conclusion Experienced observers can identify sight-threatening retinal pathology from poorer-resolution digital images that have been transmitted by telemedicine. They can also adapt to viewing less familiar images such as black and white digital or SLO images.
Similar content being viewed by others
Article PDF
References
Perednia DA, Allen A . Telemedicine technology and clinical applications. JAMA 1995;273:483–8
Yoshino MT, Carmody R, Fajardo LL, Seeger J, Jones K . Diagnostic performance of teleradiology in cervical spine fracture detection. Invest Radiol 1992;27:55–9
Scott WW, Rosenbaum JE, Ackerman SJ, Reichle RL, Magid D, Weller JC, et al . Subtle orthopaedic fractures: teleradiology workstation versus film interpretation. Radiology 1993;187:811–5
Goldberg MA, Rosenthal DI, Chew FS, Blickman JG, Miller SW, Mueller PR . New high-resolution teleradiology system: prospective study of diagnostic accuracy in 685 transmitted clinical cases. Radiology 1993;186:429–34
Andersen EB, Borgesen SE, Jensen KK, Kruse T, Rahbek M . Image transmission between hospitals via the ordinary telephone network. Ugeskrift for Laeger 1995;157:2155–8
Weinberg DS, Allaert FA, Dusserre P, Drouot F, Retailliau B, Welch WR, et al . Telepathology diagnosis by means of digital still images: an international validation study. Hum Pathol 1996;27:111–8
Kvedar Je, Edwards RA, Menn ER, Mofid M, Gonzalez E, Dover J, et al . The substitution of digital images for dermatologic physical examination. Arch Dermatol 1997;133:161–7
Loshin DS, Caputo MP . Application of telemedicine in the diagnosis of posterior fundus ocular disease. Invest Ophthalmol Vis Sci 1995;36:S429.
Li HK, Tang RA, Schiffman JS, Sy RT, Temprano JE, Prager TC . Diagnosing cytomegalovirus retinitis through telemedicine in a Texas correctional institution: a pilot study. Invest Ophthalmol Vis Sci 1996;37:S898.
Laird M, Deen M, Brooks S, Threlkeid A, Hull D, Shatz A, et al . Telemedicine diagnosis of diabetic retinopathy, cataract and glaucoma by direct ophthalmoscopy. Invest Ophthalmol Vis Sci 1996;37:492.
Friberg TR, Rehkopf PG, Warnicki JW, Eller AW . Use of directly acquired digital fundus and fluorescein angiography images in the diagnosis of retinal disease. Retina 1987;7:246–51
Webb RH, Hughes GW, Pomerantzeff O . Flying spot TV ophthalmoscope. Appl Optics 1980;19:2991–7
Blumberg MS . Evaluating health screening procedures. Oper Res 1957;5:351–60
Goodman LR, Foley WD, Wilson CR, Rimm AA, Lawson TL . Digital and conventional chest images: observer performance with film digital radiography system. Radiology 1986;158:27–33
Chakraborty DP, Breatnach ES, Yester MV, Soto B, Barnes GT, Fraser RG . Digital and conventional chest imaging: a modified ROC study of observer performance using simulated nodules. Radiology 1986;158:35–9
MacMahon H, Metz CE, Doi K, Kim T, Giger ML, Chan H-P . Digital chest radiography: effect on diagnostic accuracy of hard copy, conventional video and reversed gray scale video display formats. Radiology 1988;168:669–73
Hayrapetian A, Aberle DR, Huang HK, Fiske R, Morioka C, Valentino D, et al . Comparison of 2048-line digital display formats and conventional radiographs: an ROC study. AJR 1989;152:1113–8
Wegryn SA, Piraino DW, Richmond BJ, Schluchter MD, Uetani M, Freed HA, et al . Comparison of digital and conventional musculoskeletal radiography: an observer performance study. Radiology 1990;175:225–8
Cox GG, Cook LT, McMillan JH, Rosenthal SJ, Dwyer SJ . Chest radiography: comparison of high-resolution digital displays with conventional and digital film. Radiology 1990;176:771–6
MacMahon H, Vyborny CJ, Metz CE, Doi K, Sabetti V, Solomon SL . Digital radiography of subtle pulmonary abnormalities: an ROC study of the effect of pixel size on observer performance. Radiology 1986;158:21–6
Vakil N, Bougeois K . A prospective, controlled trial of eight-bit, 16-bit and 24-bit digital color images in electronic endoscopy. Endoscopy 1995;27:589–92
Doolittle MH, Doolittle KW, Winkelman Z, Weinberg DS . Color images in telepathology: how many colors do we need? Hum Pathol 1997:28:36–41.
Oberholzer M, Fischer H-R, Christen H, Gerber S, Bruhlmann M, Mihatsch M, et al . Telepathology with an integrated services digital network: a new tool for image transfer in surgical pathology. A preliminary report. Hum Pathol 1993;24:1078–85
de Sonnaville JJJ, van der Feltz van der Sloot D, Ernst L, Wijkel D, Heine RJ . Retinopathy screening in type 2 diabetes: reliability of wide angle fundus photography. Diabetic Med 1996;13:482–6
Reston VA . ACR standard for teleradiology. American College of Radiology, 1994.
Black-Schaffer S, Flotte TJ . Current issues in telepathology. Telemed 1995;1:95–106
Shimosato Y, Yagi Y, Yamagishi K, Mukai K, Hirohashi S, Matsumoto T, et al . Experience and present status of telepathology in the National Cancer Center Hospital, Tokyo. Zentralb Pathol 1992;138:413–7
Perednia DA, Gaines JA, Butruille TW . Comparison of the clinical informativeness of photographs and digital imaging media with multiple-choice receiver operating characteristic Arch Dermatol 1995;131:292–7
Weinstein RS, Bloom KJ, Rozek LS . Telepathology and the networking of pathology diagnostic services. Arch Pathol Lab Med 1987;111:646–52
Bloom KJ, Rozek SL, Weinstein RS . ROC curve analysis of super high resolution video for histopathology. SPIE Proc Visual Commun Image Processing 1987;845:408–12
Weinstein RS, Bloom KJ, Krupinski EA, Rozek LS . Human performance studies of the video microscopy component of a dynamic telepathology system. Zentralbl Pathol 1992;138:399–401
Krupinski EA, Weinstein RS, Bloom KJ, et al . Progress in telepathology: system implementation and testing. Adv Pathol Lab Med 1993;6:63–87
Krupinski EA, Weinstein RS, Rozek SL . Experience-related differences in diagnosis from medical images displayed on monitors. Telemed J 1996;2:101–8
Amos AF, McCarty DJ, Zimmet P . The rising global burden of diabetes and its complications: estimates and projections to the year 2010. Diabetic Med 1997;14:S7–S85.
Retinopathy Working Party. A protocol for screening for diabetic retinopathy in Europe. Diabetic Med 1991;8:263–7
Anonymous. Screening guidelines for diabetic retinopathy. American College of Physicians, American Diabetes Association and American Academy of Ophthalmology. Ann Intern Med 1992;116:683–5
British Diabetic Association. Retinal photography screening for diabetic eye disease. London: British Diabetic Association, 1997.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Cook, H., Heacock, G., Stanford, M. et al. Detection of retinal lesions after telemedicine transmission of digital images. Eye 14, 563–571 (2000). https://doi.org/10.1038/eye.2000.144
Received:
Revised:
Issue Date:
DOI: https://doi.org/10.1038/eye.2000.144