Skip to main content

Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

The Mersilene mesh ptosis sling

Abstract

A variety of materials are currently available for use in brow suspension ptosis surgery when an alternative to autogenous fascia lata is indicated. We describe the use of a Mersilene mesh sling, developed to overcome the problems of failure and extrusion commonly associated with substitute suspensory materials. The results and follow up in 23 cases of blepharoptosis are presented. Our findings suggest that the Mersilene mesh sling has a definite place in ptosis management; we currently use this sling for all cases in which autogenous fascia lata is considered inappropriate.

References

  1. Beyer CK and Albert DM : The use and fate of fascia lata and sciera in ophthalmic plastic and reconstructive surgery. Ophthalmology 1981, 88: 869–86.

    CAS  Article  Google Scholar 

  2. Crawford JS : Congenital blepharoptosis. In: Smith BV, Delia Rocca RC, Nesi FA and Lisman RD, eds. Ophthalmic Plastic and Reconstructive Surgery. St Louis: CV Mosby Company, 1987: Volume 1; 643–5.

  3. Waller RR : Evaluation and management of the ptosis patient. In: McCord CD Jnr ed. Oculoplastic Surgery. New York: Raven Press 1982: 60–8.

  4. Product Sheet—Mersilene mesh; revised 9/85 from Ethicon Ltd.

  5. Amis AA : Filamentous implant reconstruction of tendon defects: a comparison between carbon and polyester fibres. J Bone Joint Surg (Br) 1982; 643 (5): 682.

    Google Scholar 

  6. Adler RH and Fume CN : Use of pliable synthetic mesh in the repair of hernias and tissue defects. Surg Gynecol Obstet 1959; 108: 199–206.

    CAS  PubMed  Google Scholar 

  7. Adloff M and Arnaud JP : Surgical management of large incisional hernias by an intraperitoneal Mersilene mesh and an aponeurotic graft. Surg Gynecol Obstet 1987; 165 (3): 204–6.

    CAS  PubMed  Google Scholar 

  8. Downes RN and Jordan K : Surgical management of dysthyroid related eyelid retraction using Mersilene mesh. Eye 1989: 3: 385–90.

    Article  Google Scholar 

  9. Downes RN and Collin JRO : The Mersilene mesh sling—a new concept in ptosis surgery. Br J Ophthalmol 1989; 73: 498–501.

    CAS  Article  Google Scholar 

  10. Fox SA : Congenital ptosis II. Frontalis sling. J Fed Ophthalmol 1966; 3: 25.

    Google Scholar 

  11. Harrad RA, Graham CM and Collin JRO : Amblyopia and strabismus in congenital ptosis. Eye 1988; 2: 625–7.

    Article  Google Scholar 

  12. Collin JRO : A manual of systematic eyelid surgery. 1st ed. Edinburgh. Churchill Livingstone, 1983: 60–74.

  13. Morax S, Bok C and Ruban JM : Use of Gore-tex (PTFE) in ophthalmic plastic surgery. Presented to French Ophthalmological Society. Paris, May 1987. Ophthalmology (in Press).

  14. Peyman GA, Koziol J and Janevicins R : Intraocular lens fixation with Dacron mesh: part II. Ophthalmic Surg 1977; 8: 87–93.

    CAS  PubMed  Google Scholar 

  15. Lane CM and Collin JRO : Treatment of ptosis in chronic progressive external ophthalmoplegia. Br J Opthalmol 1987; 71: 290–4.

    CAS  Article  Google Scholar 

Download references

Author information

Affiliations

Authors

Rights and permissions

Reprints and Permissions

About this article

Cite this article

Downes, R., Collin, J. The Mersilene mesh ptosis sling. Eye 4, 456–463 (1990). https://doi.org/10.1038/eye.1990.58

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1038/eye.1990.58

Further reading

Search

Quick links