Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

  • ADVERTISEMENT FEATURE Advertiser retains sole responsibility for the content of this article

Safeguarding the gate to the heart

Valvular heart disease affects about 25 million people in China and 100 million worldwide every year. Nearly 50% suffer from conditions in aortic valve — the main outflow valve from the heart. Without surgical intervention as many as 50–80% of these patients don’t survive more than five years after diagnosis.

Transcatheter aortic valve replacement or implantation (TAVR or TAVI) is a well-established treatment option for elderly patients with severe aortic valve disease. This minimally invasive procedure makes small incisions and inserts a thin, flexible catheter with a prosthetic valve into the heart, providing an alternative to open heart surgery.

West China Hospital is one of the first in the country to perform minimally invasive heart valve surgeries.Credit: SomkiatFakmee/iStock/Getty

TAVI for pure aortic regurgitation (AR) — in which a damaged valve becomes ‘leaky’ — has remained a major challenge even since TAVI was developed. “In pure AR patients, there is no aortic annulus or leaflet calcification for stable anchoring of a transcatheter heart valve,” explains Yingqiang Guo, a professor of cardiac surgery and vice president of West China Hospital of Sichuan University — one of the first in China to perform minimally invasive heart valve surgeries.

Breakthrough system

Guo leads a team developing the J-Valve™, a next-generation TAVI system with three U-shaped graspers1. “This device clasps the native valve leaflets to provide adequate axial support for the prosthesis, and it solves the anchorage problem,” Guo explains.

Yingqiang Guo performs a TAVI procedure.Credit: West China Hospital of Sichuan University

To facilitate accurate self-positioning of the device, Guo takes a route through the tip of the left ventricle. This reduces the risk of perivalvular leakage and blockage of the electrical signal from the atria to the ventricles, which are problems commonly associated with TAVI procedures for aortic stenosis (AS), the narrowing of heart’s aortic valve.

Coronary blood flow blockage is also a rare but lethal complication of TAVI procedure, which the J-Valve may help to prevent. “We designed a shortened stent for the J-Valve and applied horizontal-rotation-realignment technique for its implantation to protect the arteries from occlusion,” Guo adds. Since its approval by China Food and Drug Administration in 2017, the J-Valve system has been used to treat both AR and AS in more than 200 hospitals worldwide.

TAVI in bicuspid AS

Among elderly AS patients, approximately 50% have a bicuspid aortic valve (BAV). It has been long considered a condition relatively difficult to treat with TAVI due to its complex anatomical features. To solve this, Mao Chen, director of the Cardiology Department, has led a multidisciplinary team to establish a pathway for using TAVI in bicuspid AS patients.

Mao Chen performs a TAVI procedure.Credit: West China Hospital of Sichuan University

“The trickiest issue is prosthetic valve sizing,” says Chen. The team has proposed ‘supra-annular structure’ concept based on imaging and biomechanics studies. Their ‘supra-annular sizing’ algorithm2 has led to more stable valve deployment and optimized interaction between the prosthesis and the aortic root.

“With this new sizing algorithm, the risk of valve instability and associated complications due to incorrect size selection is reduced in 62.5 % of bicuspid AS patients, significantly increasing the device success rate,” Chen explains.

To get better results, the team has developed a novel ‘reshaping TAVI’ technique. In a pilot study, the researchers inflate an hourglass-shaped valvuloplasty balloon to dilate and reshape the BAV more effectively before valve deployment.

Chen is working with industry to develop VenusA-Valve and Venus-PowerX for bicuspid AS patients. As one of the most experienced teams globally in TAVI, they’ve initiated the PCR-CIT China Chengdu Valves, an annual academic conference to share progress on TAVI treatment since 2015. Recently, the team led the development of the first international expert consensus guideline on TAVI in bicuspid AS patients3.