Main

In multicellular organisms, the timely execution of programmed cell death is critical for numerous physiological processes including embryogenesis, post-embryonic development and adult tissue homeostasis. It is, therefore, not surprising that deregulated cell death is a common feature of a wide array of human diseases. On one hand, the unwarranted death of postmitotic cells constitutes one of the most important etiological determinants of acute and chronic pathologies including (but not limited to) ischemic, toxic, neurodegenerative and infectious syndromes. Conversely, disabled cell death is frequently associated with hyperproliferative conditions such as autoimmune diseases and cancer. Several well-established and experimental therapies target the molecular mechanisms of cell death, either to prevent the demise of cells that cannot be replaced, or to facilitate the elimination of supernumerary and/or ectopic cells.1 Thus, the precise characterization of the molecular machinery of cell death constitutes a major challenge for present and future research, which has already and will continue to have tremendous repercussions on the development of novel therapeutic approaches.

The first and most important question that any researcher who studies cellular demise needs to answer is: when is a cell ‘dead’? Recently, the Nomenclature Committee on Cell Death (NCCD) has formulated several recommendations on the use of cell death-related terminology.2 Dying cells are engaged in a cascade of molecular events that is reversible until a first irreversible process takes place, and the ‘point-of-no-return’ that delimits the frontier between a cell's life and death has been trespassed. So far, a single molecular event that accounts for the point-of-no-return in the signaling cascades leading to cell death remains to be identified. Thus, the NCCD has proposed that a cell should be regarded as ‘dead’ when (1) the cell has lost the integrity of its plasma membrane and/or (2) the cell, including its nucleus, has undergone complete disintegration, and/or (3) its corpse (or its fragments) has been engulfed by a neighboring cell in vivo.

In this context, another important issue is represented by the indisputable existence of numerous cell death modalities.2 Cell death represents a highly heterogeneous process that can follow the activation of distinct (although sometimes partially overlapping) biochemical cascades and can manifest with different morphological features. For instance, cells can die as they display an apoptotic morphology (which among other features is characterized by chromatin condensation, nuclear fragmentation and overall shrinkage of the cell) or a necrotic one (which is associated with a gain in cell volume, organellar swelling and disorganized dismantling of intracellular contents). Mixed cell death morphotypes characterized by both apoptotic and necrotic traits have also been described, which has led some investigators to suggest the existence of a ‘continuum’ of cell death phenotypes, at least in specific experimental settings.3 Such morphological heterogeneity frequently derives from the activation of separate executioner mechanisms. Thus, beyond merely encyclopedic intents, the correct classification of cell death into specific subroutines may be extremely important for its therapeutic implications. As an example, tumor cells are often resistant to chemotherapeutic regimens that induce apoptosis, but not to necrotic triggers. In this context, the induction of one specific cell death mode (i.e., necrosis), as opposed to another (i.e., apoptosis), would result in an obvious therapeutic advantage.

The term ‘autophagic cell death’ has been widely employed to indicate a type of cell death that is accompanied by massive vacuolization of the cytoplasm.2 However, the relationship between autophagy and cell death remains controversial.4, 5 Multiple Drosophila melanogaster developmental scenarios (including involution of salivary glands, early oogenesis and removal of the extraembryonic tissue known as amnioserosa) provide in vivo evidence that cell death can be (at least partially) executed through autophagy.6, 7, 8, 9 Consistent with these results, the knockout/knockdown of essential autophagy (atg) genes has been shown to protect cultured mammalian cells from some lethal inducers, at least in specific experimental settings.10 Still, more frequently, pharmacological and/or genetic inhibition of autophagy does not prevent cell death, and rather accelerates it.11, 12 This suggests that although cell death can occur together with autophagy, the latter likely represents a prosurvival mechanism activated by dying cells in the attempt to cope with stress.11, 12 As very detailed guidelines concerning the use and interpretation of assays for monitoring autophagy have been recently provided by Klionsky and colleagues,13 this topic will not be discussed further in the present review.

Nowadays, dozens (if not hundreds) of methods are available for the detection of cell death-related parameters in vitro (in cell cultures), ex vivo (in explanted tissues and/or organs) and in vivo (in model organisms and/or humans; Figure 1). Since the beginning of cell death research, this methodological collection has been evolving, driven by the technological innovation that has characterized the last decades. However, some of the classical methods to identify dead and dying cells (e.g., light microscopy-based techniques) continue to be largely employed by researchers (due to their simplicity and/or low cost), even though they may be rather nonspecific and, therefore, inappropriate in the majority of experimental settings. Conversely, the precise quantification of a single molecular process may be excessively specific, and also result in the over- and/or underestimation of cell death. Numerous methods to detect cell death can only be applied to a limited number of experimental settings, due to intrinsic features of the model system or technical limitations of the platform on which such protocols are implemented.

Figure 1
figure 1

Methods to detect cell death-related variables. Nowadays, a cornucopia of techniques is available to monitor cell death-related parameters. Within this ‘methodological abundance/redundancy’, the choice of the most appropriate techniques and the correct interpretation of results are critical for the success of any study dealing with cell death. Here, the most common procedures to detect dead/dying cells are indicated, together with the technical platforms that are required for their execution and the types of specimens on which they can be applied. Please see the main text for further details. Δψm, mitochondrial transmembrane potential; HPLC, high-pressure liquid chromatography; MOMP, mitochondrial outer membrane permeabilization; MPT, mitochondrial permeability transition; MS, mass spectrometry; NMR, nuclear magnetic resonance; PS, phosphatidylserine; SDS-PAGE, sodium dodecyl sulfate-polyacrylamide gel electrophoresis

Beyond obvious technical variations, the experimental procedures to identify dead and dying cells differ from one another with regard to (and hence may be classified according to) (1) specificity (i.e., some techniques selectively detect apoptosis-related phenomena, such as internucleosomal DNA cleavage, whereas others cannot discriminate between apoptotic and nonapoptotic cell death subroutines); (2) sensitivity (which is determined by the lower detection limit); (3) detection range (which relates to the upper detection limit); (4) precision (i.e., cell death-related parameters can be detected in a qualitative, semiquantitative or quantitative fashion); (5) throughput (which can be low, as for electron microscopy-based methods, standard, as for normal laboratory practices, or high, as for automated procedures); (6) cell death stage (meaning that biochemical processes belonging either to the induction/initiation, integration/decision or execution/degradation phases of the cell death cascade can be specifically quantified); (7) cell death parameter (i.e., morphological versus biochemical) or (8) readout (which can be an end-point or a real-time measurement). Concerning specificity, a clear-cut distinction has to be made between ‘general’ and ‘cell death-type specific’ techniques. Although the former (e.g., vital dyes) can detect end-stage cell death irrespective of its type (most frequently by assessing the structural dismantling of dead cells and in particular plasma membrane breakdown), the latter (e.g., caspase activation assays) monitor processes that have been specifically, yet not exclusively, associated with a particular subroutine of cell death. This hierarchical subdivision reflects the correct experimental approach that should be used when studying cell death (see also ‘Concluding remarks’).

Irrespective of the possible categorization of the methods to detect cell death, standardized guidelines on their use and interpretation have never been formulated. Recently, Klionsky and colleagues have approached a similar issue concerning the techniques to detect autophagy.13 Along the lines of this work, we propose here a comparison of the most common methodologies to identify and quantify dead and dying cells, with particular emphasis on their relative advantages/drawbacks and on their suitability for specific versus common experimental scenarios.

Light Microscopy, Electron Microscopy and (Immuno)cyto(histo)chemistry

Visual inspection by light microscopy provides a rapid and inexpensive means to detect cell death in a generalized and rather nonspecific fashion. This can be done on living samples (in phase contrast mode, for instance, to monitor the conditions of cultured cells), or on fixation and staining of cytospins and/or histological sections. The most common cyto(histo)chemical protocols include Papanicolaou and Mayer's hematoxylin/eosin (H&E) stains, both of which allow the visualization of multiple intracellular structures, and in particular of the nuclei. Thus, cells displaying morphological changes that normally are associated with cell death, such as pyknotic nuclei, membrane blebbing or swollen cytoplasm can be visualized. Still, these techniques are time consuming and operator dependent, and tend to underestimate the fraction of dead/dying cells. This is due to the fact that cells in the early phases of lethal cascades usually fail to display gross morphological modifications, and hence remain undetected by these approaches. Similarly, light microscopy-based techniques fail to recognize completely disintegrated cells, whose fragments are too small to be seen. These sources of underestimation can be partially overcome by video or time-lapse microscopy, allowing for the cumulative scoring of cell death throughout the entire duration of experiments. Moreover, when the fraction of dead cells is low (as it is often the case in vivo), it may be difficult for the operator to perceive them within the normal tissue architecture (for instance in histological sections). In this context, the use of vital dyes (i.e., dyes that selectively stain either live or dead cells), such as trypan blue or crystal violet, is advantageous in that it limits underestimation, by allowing the identification of dead cells that have not yet undergone significant structural modifications. Although exclusion dyes (i.e., vital dyes that cannot enter or are actively extruded by healthy cells, yet are taken up by cells with permeabilized plasma membranes) provide a very simple means to estimate the amount of live (and hence dead) cells in counting chambers, light microscopy-based techniques are inappropriate for high-throughput applications. However, visual inspection by light microscopy can be useful to follow the degenerative changes that are associated with the death of postmitotic cells over time (e.g., neurons, cardiomyocytes and myotubes). Indeed, as these cells do not replicate, they cannot be studied by methods that require a large number of cells (e.g., cytofluorometry) nor by techniques that are based on proliferation (e.g., clonogenic assays; see below).

(Immuno)cyto(histo)chemistry protocols coupled with light microscopy allow for the quantification (in cytospins or histological sections) of cells characterized by some (but not all) of the biochemical changes associated with cell death. This applies, for instance, to caspase activation or PARP-1 proteolytic processing, and in general to all molecular processes that can be detected by specific primary antibodies, including activation-dependent accumulation (e.g., p53), overexpression (e.g., Puma); cleavage (e.g., procaspases; caspase substrates), phosphorylation/dephosphorylation (e.g., p53, p38MAPK), conformational changes (e.g., Bax; Bak) and other posttranslational modifications (e.g., acetylation, sumoylation). Secondary antibodies coupled to horseradish peroxidase or to alkaline phosphatase can be revealed with chromogenic substrates, and positive cells display a brownish-blackish color, which is readily detectable, for instance over an H&E background. Less prone to underestimation than biochemical stains (and hence more suitable for quantitative applications), (immuno)cyto(histo)chemistry protocols are also advantageous because they allow for the detection of early cell death-related events, such as the cleavage of initiator caspases. Still, these methods heavily depend on the performance (background, specificity) of the primary antibody of choice, and are limited to low levels of throughput.

One classical application of cyto(histo)chemistry is the detection of DNA fragmentation by the terminal deoxynucleotidyl transferase-mediated dUTP nick-end labeling (TUNEL) method.14 This technique is characterized by higher sensitivity than most other cyto(histo)chemical approaches and has long been considered to be the gold standard to detect apoptosis in situ. However, TUNEL false positivity may result from necrotic cell death (at least in some cases), as well as from inappropriate processing of samples, which may occur – for example – during sectioning.15 For these reasons, although in many cases (and in particular in some disease models)16 TUNEL remains the only method for investigating apoptosis in situ, whenever possible, researchers should include appropriate positive and negative controls and should corroborate the results of TUNEL by at least one independent experimental approach.

Electron microscopy permits the visualization of fine ultrastructural modifications that accompany cell death, including gaps in the plasma and/or in the mitochondrial outer membrane,17 mitochondrial swelling18 and the first phases of chromatin condensation (which only later become visible by light microscopy).19 Although electron microscopy can provide an impressive amount of ultrastructural information, the visual inspection of electron microphotographs should always be complemented by a robust quantitative approach. Indeed, as the analysis is conducted on a per-cell basis and only a fraction of cells within each sample can be studied, this is critical for researchers to avoid focusing their investigation on rare (or even artefactual) morphologies. Moreover, sample processing/staining for electron microscopy is very laborious and requires trained personnel. Nevertheless, immunoelectron microscopy procedures can provide very detailed insights into the molecular mechanisms of cell death. As an example, the use of secondary antibodies coupled to gold particles of different sizes has been successfully employed to precisely visualize the colocalization of Bax with Bid and VDAC-1 in apoptotic human tumor cells.20 Thus, although electron microscopy cannot be used for routine determinations, it is nearly irreplaceable for the ultrastructural analysis of some processes linked to cell death.

Table 1 summarizes the advantages and pitfalls of light microscopy, electron microscopy and (immuno)cyto(histo)chemistry applied to cell death research.

Table 1 Light microscopy, electron microscopy and (immuno)cyto(histo)chemistry applied to cell death research

(Immuno)fluorescence Microscopy and Immunoblotting

Nearly all (immuno)cyto(histo)chemical protocols can be transposed to fluorescence microscopy approaches, with a number of significant advantages. First, fluorescence generally (but not always, see below) ensures a higher signal-to-noise ratio than chromogenic techniques, which improves sensitivity. Second, the detection method does not involve an enzymatic reaction, whose efficacy may be perturbed by several variables including buffer composition, pH and temperature. Third, secondary antibodies coupled to fluorochromes with distinct absorption/emission spectra are compatible with sophisticated costaining protocols, which permits the routine detection of three to four distinct cell death-related events at the same time. Fourth, fluorescent dyes and fluorescent fusion proteins can be employed in combination with immunological methods, further extending the parameters that can be monitored at the same time. Finally, confocal (but not conventional) immunofluorescence microscopy enables 3D reconstitution of samples, which may be useful for colocalization experiments (see below for a note of caution).

The most common applications of (immuno)fluorescence microscopy for cell death research include, but are not limited to (1) quantification of viable cells by the calcein retention technique;21, 22 (2) highly specific detection of apoptotic cells in live tissue and embryos (from model organisms as diverse as D. melanogaster, Xenopus leavis, zebrafish and mice) with acridine orange (AO);23, 24, 25 (3) identification of live, apoptotic and necrotic cells on acridine orange/ethidium bromide (AO/EB) staining;26 (4) visualization of nuclear condensation with Hoechst 33342 or 4′,6-diamidino-2-phenylindole (DAPI);27 (5) TUNEL, performed with fluorochrome-coupled streptavidin to recognize biotinylated dUTP;28 (6) stable mitochondrial staining (for colocalization experiments, see below) with fixable Δψm-sensitive dyes (e.g., chloromethyl-X-rosamine, CMXRos);29 (7) real-time monitoring of the Δψm in living cells via nontoxic Δψm-sensitive fluorochromes (e.g., 5,5′, 6,6′-tetrachloro-1,1′,3,3′-tetraethylbenzimidazolcarbocyanine iodide, JC-1; tetramethylrhodamine methyl ester, TMRM);26, 30 (8) quantification of cells characterized by massive caspase activation;19 (9) detection of the so-called mitochondrial permeability transition (MPT) via the calcein quenching method;31 (10) analysis of the mitochondrial relocalization of proapoptotic proteins from the Bcl-2 family (e.g., Bax, Bid);32, 33 (11) detection of the cytosolic spillage of lysosomal proteins (e.g., cathepsin proteases),34, 35 which is indicative of lysosomal membrane permeabilization (LMP);36 (12) monitoring of the mitochondrio-cytosolic (or mitochondrio-nuclear) translocation of mitochondrial intermembrane space (IMS) proteins (e.g., cytochrome c (Cyt c), apoptosis-inducing factor (AIF)).37, 38, 39 Notably, relocalization studies can be performed as end-point measurements by indirect immunofluorescence staining,40 and also in real time by video or time-lapse microscopy of living cells that have been engineered to express constitutive, inducible or photoactivatable green fluorescent protein (GFP)-tagged proteins.32, 33, 41, 42, 43

Until recently, visual quantification of cells characterized by one or more cell death-related parameters was required to obtain quantitative data from (immuno)fluorescence microscopy-based techniques, which represented one of their most relevant weaknesses. Fortunately, this has begun to change with the progressive dissemination of high-throughput workstations that allow for automated image acquisition from 96-well plates and software-assisted image analysis. In some cell types, autofluorescence (which results in a very poor signal-to-noise ratio) greatly restricts the usefulness of fluorescence-based (as opposed to chromogenic) detection. Moreover, as compared to (immuno)cyto(histo)chemistry, (immuno)fluorescence microscopy is intrinsically limited in that it does not allow for the simultaneous observation of labeled and unlabeled structures. This might be particularly relevant for histological studies, which often involve the visual inspection of overall tissue architecture. At least partially, this drawback can be circumvented by the sequential acquisition (from the same field) of each fluorescent signal as well as of the bright and/or dark field, followed by software-assisted image reconstitution.

Finally, to avoid common misinterpretations of immunofluorescence microscopy-derived results, it should always be remembered that (1) protein-to-protein colocalization does not necessarily mean protein-to-protein physical/functional interaction; (2) colocalization assays require confocal microscopes (which, as opposed to conventional microscopes) can acquire images from distinct z planes); (3) due to physical constraints, the resolution of such instruments along the z axis is significantly worse than along the x and y axes, and never lower than 350 nm and (4) to compensate for limited Z-resolution, 3D reconstruction software is generally based on extrapolation algorithms. For all these reasons, confocal immunofluorescence microscopy is appropriate to determine rather gross colocalizations (e.g., between a protein and a subcellular compartment), but cannot replace immunoelectron microscopy for extremely precise spatial determinations, nor coimmunoprecipitation assays to ascertain protein-to-protein physical interactions.

Immunoblotting (alone or combined with immunoprecipitation) has also been widely employed for qualitative and/or semiquantitative analysis of cell death-related phenomena, including (de)phosphorylation-dependent activation of cell death regulators (e.g., p53, Bcl-2),44, 45 conformational changes in proapoptotic Bcl-2 protein family members (e.g., Bax, Bak),46, 47 caspase activation (by employing either monoclonal antibodies specific for active caspases or antisera that recognize both the processed and proenzymatic caspase form),47 cleavage of caspase substrates (e.g., cytokeratin 18, PARP-1)47, 48 and translocation of IMS proteins (e.g., Cyt c, AIF) to extramitochondrial compartments.49 In contrast to immunofluorescence microscopy-based methods, immunoblotting allows the study of subcellular fractions, and in particular the analysis of the release of IMS proteins from purified mitochondria.39 Nonetheless, immunoblotting protocols are time consuming, unsuitable for large-scale applications and provide reliable semiquantitative results only when primary antibodies are employed at subsaturating concentrations. Moreover, although fluorescence-based detection ensures enhanced sensitivity as compared to classical chemiluminescence, the detection of small and/or weakly expressed proteins may be difficult to achieve and/or require prolonged optimization. Finally, it should be kept in mind that although (immuno)fluorescence microscopy-based quantifications are performed on a per-cell basis, semiquantitative immunoblotting data represent whole cell populations, irrespective of any intrapopulation, intercell heterogeneity. Thus, immunoblotting is not ideal for the analysis of heterogeneous cell samples such as primary tissues or solid tumors.

In Table 2, the benefits and disadvantages of (immuno)fluorescence microscopy- and immunoblotting-based methods to monitor cell death are illustrated.

Table 2 (Immuno)fluorescence microscopy- and immunoblotting-based methods to detect cell death

Cytofluorometry and Luminometry

The most convenient technique to study cell death on a per-cell basis is cytofluorometry. To this aim, dozens of protocols have been optimized, for instance based on (1) cell-permeant probes with different functional properties (e.g., 3,3′dihexiloxalocarbocyanine iodide (DiOC6(3)), JC-1 or TMRM, to measure Δψm; calcein, to monitor MPT);50, 51 (2) plasma membrane-impermeant fluorochromes, used as exclusion dyes (e.g., DAPI; propidium iodide (PI));52 (3) fluorochrome-coupled secondary antibodies, for indirect immunostaining procedures (which can detect nearly all processes that can be visualized by immunofluorescence microscopy, see above); (4) chromatinophilic dyes, to quantify cells with a sub-G1 DNA content (e.g., DAPI or PI, on plasma membrane permeabilization; Hoechst 33342);53 (5) fluorochrome-coupled Annexin V, to detect the exposure of phosphatidylserine (PS) on the outer leaflet of the plasma membrane;54 (6) fluorogenic caspase or cathepsin substrates55, 56 or (7) oxidative stress-sensitive probes (e.g., 2′,7′-dichlorodihydrofluorescein diacetate (H2DCFDA), hydroethidine (HE)).40, 57 Moreover, cytofluorometry has been employed to detect the morphological modifications that characterize apoptosis (i.e., cell shrinkage and augmented granularity of the intracellular content), the changes in morphology and Δψm dissipation of purified mitochondria undergoing MPT in vitro,58, 59 as well as a readout for TUNEL.

The detection of light scattering and up to 10 different fluorescent signals allows for the simultaneous yet independent analysis of 10–12 distinct parameters on living or fixed cell suspensions. In this context, it is critical to remember that not all protocols for cytofluorometry are compatible with each other, and hence can be combined into a single multiparametric study. This relates to the possible overlap between emission spectra from distinct fluorochromes, and also to sample processing. As an example, protocols that require plasma membrane permeabilization (e.g., assessment of the cell cycle distribution with chromatinophilic fluorochromes, quantification of intracellular antigens by indirect immunostaining) are inherently incompatible with methods based on intact cells (e.g., incorporation of exclusion dyes, Annexin V-mediated detection of PS exposure).

In contrast to (immuno)fluorescence microscopy-based methods, cytofluorometric techniques provide quantitative results independently from visual quantification of ‘positive’ events, which limits operator-dependent bias, and allows for the rapid acquisition of 10 000–100 000 events per sample, resulting in increased statistical power and higher throughput. The recent introduction of 96-well plate cytofluorometers will further augment the applicability of these approaches to high-throughput screening (HTS) procedures. Still, the need for a large number of cells makes cytofluorometry inappropriate for the study of primary (and in particular postmitotic) cell cultures. Moreover, as cytofluorometric methods require cell-to-cell dissociation, they are intrinsically unsuitable for the direct study of histological sections. Fluorogenic caspase substrates are prone to unspecific degradation, both in cells and in cell lysates, which may lead to false-positive results. In this context, the use of caspase inhibitors can help in determining the caspase-specific signal. Finally, as a caveat to the use of PS exposure alone as a marker of early apoptosis, it should be noted that (1) if plasma membranes are permeabilized (as during late apoptosis or early necrosis) Annexin V can bind to intracellular PS; (2) PS exposure can prepare cells for phagocytic removal independently of apoptosis60 and that (3) PS exposure can be compromised in cells in which autophagy is impaired.61

Luminometry has been primarily applied to cell death research for the quantification of intracellular bioenergetic stores, based on reports suggesting that the ATP/ADP ratio can be used to discriminate between apoptosis, necrosis and arrested proliferation.62 Luminometry-based techniques are extremely sensitive (due to a nearly undetectable background) and 96-well plate luminometers are widely available. However, ATP and ADP levels are rapidly affected by extracellular and/or intracellular perturbations, and hence cannot be used alone (without further validation by complementary tests) for the detection of a complex phenomenon such as cell death. As an example, nutrient depletion often results in a significant consumption of ATP that is not followed by cell death, due to the activation of the autophagic pathway.63

Table 3 summarizes the advantages and drawbacks of cytofluorometry and luminometry-based methods for the study of cell death.

Table 3 Cytofluorometric and luminometric techniques to monitor cell death-related variables

Spectrophotometry

Due to the fact that they are fairly suitable for automation (and hence adaptable to high-throughput procedures), numerous 96-well plate-based methods are used to study cell death-related parameters. For instance, plasma membrane breakdown (as a sign of cytotoxicity) can be detected by assessing culture supernatants for the activity of enzymes that are normally confined within the cell (e.g., lactate dehydrogenase (LDH)).47 Moreover, the activity of the mitochondrial respiratory chain is widely considered as an indicator of the number of viable cells, and hence measured to study cell death versus proliferation. To this aim, the most common protocols involve membrane-permeant colorless tetrazolium salts, which can be administered to living cells and are converted by metabolically active mitochondria into colored products.19, 47, 64 The widely employed, first-generation tetrazolium derivative 3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyl tetrazolium bromide (MTT) is reduced by mitochondrial dehydrogenases to formazan, which is water-insoluble and hence accumulates in cytosolic crystals. As a consequence, the spectrophotometric quantification of formazan requires cell lysis and overnight solubilization of crystals, which – however – are cytotoxic even in small amounts. Thus, MTT conversion can only be employed in the context of end-point determinations. As opposed to MTT, second-generation tetrazolium derivatives (e.g., 3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium (MTS) or 4-[3-(4-iodophenyl)-2-(4-nitrophenyl)-2H-5-tetrazolio]-1,3-benzene disulfonate (WST-1)) are metabolized into nontoxic, water-soluble, membrane-permeant products, which freely diffuse in the culture supernatant. Thus, MTS and WST-1 do not compromise the viability of cultures, thereby being compatible with recurring and/or real-time determinations.

Both LDH release and MTT/MTS/WST-1 conversion are commonly employed for cell death research, presumably because (1) they allow for the simultaneous analysis of a large number of specimens; (2) they are rapid and do not require preprocessing of samples (e.g., cell lysis); (3) they do not need specialized laboratory equipment; (4) ready-made kits are available, which often include appropriate controls and (5) they are fairly economical (as compared to immunological techniques). Nevertheless, both LDH release and MTT/MTS/WST-1 tests suffer from considerable drawbacks. For instance, the release of LDH cannot be used for discriminating among distinct cell death modalities. Moreover, this test measures an enzymatic activity, which tends to decrease with time as a result of natural degradation, and can be affected by several variables, including pH as well as the presence of specific components in the culture medium. The conversion of MTT/MTS/WST-1 by mitochondrial enzymes may reflect metabolic alterations that do not necessarily correlate with the number of viable cells. Medium overconsumption and/or excessive cell density are two very common situations that result in a pronounced shutdown of mitochondrial functions. In these conditions, the use of an MTT/MTS/WST-1-based test alone would lead to the underestimation of the number of living cells. In summary, the use of these colorimetric methods is advisable only for the preliminary phase of a cell death study, when hundreds to thousands of conditions have to be screened, and only as long as relevant controls are included. In this context, a valuable approach would be to integrate these assays with one another, allowing for the cross-confirmation of the cytotoxicity and proliferation datasets.

Several kits based on the enzyme-linked immunosorbent assay (ELISA) principle are available to measure cell death-related parameters in cell culture supernatants, intact cells, subcellular fractions, tissue extracts or body fluids. ELISA-based assessments have been optimized to monitor phenomena as different as Cyt c release, caspase-3 activation, release of intracellular proteins following plasma membrane breakdown, presence of dissociated nucleosomes due to chromatin fragmentation, and expression on the cell surface of death receptors and/or their ligands, for instance. Nearly all these methods can be implemented on 96-well plates, allowing for quantification by standard laboratory spectrophotometers, and they are often characterized by increased sensitivity. Depending on the specific process that is monitored, some of these protocols may require laborious preprocessing of samples, which in turn limits throughput. As an example, ELISA-based kits that quantify Cyt c release require subcellular fractionation, and hence provide few/no advantages as compared to immunofluorescence microscopy or cytofluorometry.27 Still, miniaturized assays of this kind are well adapted for the precise quantification of cell death-related factors released in the culture medium or in body fluids by dead/dying cells (e.g., nuclear matrix protein (NMP)),65 which usually requires no/limited preprocessing. In this context, two interesting applications are represented by the detection of cytoplasmic versus extracellular histone-associated DNA fragments,66 and of caspase-cleaved versus full-length cytokeratin 18 in extracellular fluids,67, 68 because they can provide an estimation of apoptotic versus nonapoptotic cell death. For the correct interpretation of this kind of quantitative data – however – it should be noted that all ELISA-detectable markers decay (perhaps with the exception of caspase-cleaved cytokeratin 18), due to both enzymatic and nonenzymatic reactions. This precludes any quantitative correlation between the concentration of a given marker and the percentage of dead/dying cells, which in turn makes these assays not ideal for cell death research.

Spectrophotometry has often been used to monitor MPT in vitro, on mitochondria purified from cell cultures or rodent organs and resuspended in sucrose media. Under these conditions, MPT leads to an abrupt increase in the volume of the mitochondrial matrix (known as ‘large amplitude swelling’), which can be followed by measuring the absorbance of the mitochondrial suspension at 545 nm. This method has been successfully implemented on 96-well plates, which can be monitored by standard laboratory spectrophotometers.27 As most of these instruments are able to simultaneously measure several types of signal (e.g., absorbance, fluorescence, luminescence), swelling measurements can be combined with additional tests (e.g., calcein quenching assays, Δψm-sensitive dyes, Ca2+-sensitive probes) in the context of a multiparametric analysis.69, 70 Moreover, the use of pure mitochondrial suspensions enables investigators to define a specific experimental microenvironment, and hence is essentially irreplaceable for studying the direct induction of MPT by a given molecule in the absence of metabolic interference. For the same reasons, this technique cannot be used to investigate the effect of molecules that act on mitochondria by indirect mechanisms, for instance via metabolic intermediates or by activating intracellular signaling pathways. Finally, large amplitude swelling is not easily exploitable in high throughput applications for at least two reasons. First, such applications would require a large amount of mitochondria, in turn demanding either the killing/postmortem processing of dozens of rodents at the same time or the simultaneous culture and subcellular fractionation of billions of cells. Second, in energized buffers in vitro, mitochondria retain their structural and functional integrity only for a limited time (4–6 h).

In Table 4, spectrophotometric methods for monitoring cell death are compared based on their advantages and pitfalls.

Table 4 Spectrophotometry applied to cell death research

Other Techniques

Clonogenic assays constitute a technique of choice to determine the long-term fate of proliferating cells, because they can identify an irreversible arrest of cell growth occurring so late that it would go undetected by other methods.71 Although clonogenic assays cannot differentiate between cell demise and senescence (which is not a form of cell death),2 they represent the gold standard method to study the cytotoxic versus cytostatic effects of anticancer agents. The long-term fate of senescent cells has not yet been precisely determined, and may considerably fluctuate in distinct experimental settings. Most likely, with time, senescent cells activate a hitherto unidentified signaling cascade that eventually ensures their disposal. However, as loss of clonogenicity does not necessarily derive from cell demise,2 clonogenic assays are intrinsically not ideal to study ‘pure’ cell death.

DNA agarose gel electrophoresis followed by EB staining has represented a cornerstone method to discriminate between apoptotic, internucleosomal DNA fragmentation (resulting in the so-called ‘DNA ladder’, whose ‘rungs’ are represented by DNA fragments of 180 bp and multiples thereof) and necrotic, nonspecific DNA degradation (resulting in a ‘smear’ of randomly degraded DNA).72 Although less laborious than protein electrophoresis, this method (as opposed to immunoblotting) is being increasingly disregarded due to the existence of cost-effective alternatives that monitor the same process, such as TUNEL. In spite of the fact that agarose gel electrophoresis is less prone to false positivity than TUNEL and that noncarcinogenic nonradioactive stains provide a safe alternative to ethidium bromide, nowadays this technique is rarely used in cell death research.

One recently developed technological platform, known as ImageStream, allows for the simultaneous acquisition of both overall fluorescence and of several microphotographs (in either bright-field, dark-field or fluorescence imaging mode) from each flowing cell. This instrument, which combines the visual resolution of (immuno)fluorescence microscopy with the statistical power of cytofluorometry, is being increasingly applied to cell death research. As an example, unique combinations of photometric and morphometric measures, as acquired by the ImageStream cytofluorometer in a single run, have been used to discriminate among live, (early and late) apoptotic and necrotic cells.73 It can be anticipated that several other techniques to quantify cell death-related parameters will be implemented on this technological platform during the next few years.

Additional protocols to detect cell death-related parameters rely on nuclear magnetic resonance (NMR), high-pressure liquid chromatography (HPLC) and mass spectrometry (MS). For instance, the NMR properties of the structured water (i.e., bound to macromolecules) within mitochondria have been exploited to discriminate among MOMP, MPT and more complex scenarios (such as those affecting mitochondria in vivo).74 HPLC has been used to quantify the release of Cyt c from purified rat liver mitochondria, which is more rapid and ensures higher sensitivity than ELISA- or immunoblotting-based methods.75 Proteomic approaches based on subcellular fractionation followed by MS analysis have been used in multiple cell death-related settings, including the identification of proteins released by mitochondria undergoing MPT,76 or of proteins that are exposed on the plasma membrane surface of apoptotic cells.77 These techniques, and in particular MS-based proteomic studies, provide a large amount of experimental data, which allows for the in-depth investigation of cell death-related phenomena. However, they are suboptimal for routine determinations, because each requires a sophisticated technology, qualified personnel and a nonnegligible phase of optimization for every experimental protocol.

Table 5 presents the benefits and drawbacks of additional techniques applied to cell death research.

Table 5 Other techniques to detect cell death-related phenomena

Concluding Remarks

Dozens of methods exist to measure cell death-related parameters, which depend on distinct technologies and which can be distinguished with regard to their specificity, sensitivity, detection range, precision and throughput. Each of these techniques was originally developed for a specific purpose, and some have evolved toward more general applicability. Thus, a cornucopia of protocols is available for the study of cell death. Nevertheless, none of these methods is sufficient per se to unambiguously demonstrate cell death, and a combination of complementary yet unrelated techniques should always be employed (see below). Such a methodological profusion may result (and has indeed too often resulted) in the use of assays that are completely inappropriate for the experimental setting under investigation. Both authors and reviewers must be blamed for the publication of papers in which cytotoxic and/or cytoprotective effects have been erroneously described, due to the use of inappropriate methods. Thus, in multiple instances, caspase activation has been (mis)interpreted as an unequivocal sign of apoptotic cell death when it is known that caspases also participate in many processes not linked to cellular demise.78 This common mistake can now be avoided thanks to the increasing knowledge on the specific substrates that are cleaved by caspases during cell death but not in cell death-unrelated scenarios.79 As an example, in erythroblasts, the transcription factor GATA-1 is cleaved by caspase-3 on death receptor engagement,80 yet it remains uncleaved when caspase-3 is activated during erythroid differentiation.81

No guidelines will ever address in a specific fashion each experimental scenario related to cellular demise. Thus, to avoid false-negative and/or -positive results as well as gross misinterpretations, researchers should approach the study of cell death (as defined by the etymological recommendations recently provided by the NCCD)2 by bearing in mind the following two fundamental questions: (1) are cells truly dead, and if so, (2) by which subroutine did cell death occur? To answer the first question, investigators need to combine at least two distinct methods that assess end-stage cell death (e.g., LDH release and incorporation of exclusion dyes, in vitro), and perform, whenever possible, long-term survival assays to detect delayed cell death events (especially for postmitotic cells). In doing so, they will obtain a reliable, quantitative evaluation of cell death, which is a sine qua non for subsequent studies (see below).

Similarly, to characterize cell death in mechanistic terms (i.e., to answer the second question), at least two complementary, but methodologically unrelated, techniques should be employed to demonstrate the involvement of the same biochemical phenomenon. As an example, the activation of caspases may be indisputably proved by combining miniaturized fluorogenic assays with cytofluorometry- and/or immunofluorescence microscopy-based tests. As cell death is highly heterogeneous – however – the signaling pathways that lead to cell death may differ even across relatively similar experimental settings. Thus, it remains at each investigator's discretion to decide which are the most appropriate biochemical parameters that should be monitored for the mechanistic characterization of cell death in his/her experimental setup. As a final – but cardinal – note of caution, it should always be remembered that several cell death-related phenomena (e.g., activation of caspases, p53-dependent gene transactivation) also occur in cell death-unrelated settings (e.g., differentiation of several hematopoietic precursors, DNA repair).78, 82 It is, therefore, crucial for researchers to answer the above-mentioned questions in the correct order, to avoid the arguably worst mistake of all: investigating the mechanisms of cell death in the absence of cell death.