Skip to main content

Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

  • Clinical Oncology/Epidemiology
  • Published:

Clinical Oncology/Epidemiology

Measurement of cytokeratin 19 fragments as a marker of lung cancer by CYFRA 21-1 enzyme immunoassay

Abstract

Soluble cytokeratin fragment 19 levels were measured with an enzyme immunoassay method developed by Boehringer Mannheim (Enzymun-Test CYFRA 21-1) in the serum of 185 patients with lung cancer [149 with non-small-cell lung cancer (NSCLC) and 36 with small-cell lung cancer (SCLC)] and 97 patients with benign lung diseases in order to determine its clinical usefulness in the diagnosis of lung cancer and follow-up of treatment. We used the cut-off value of 3.5 ng ml-1, established by the Japan CYFRA research group. This cut-off value is based on calculations using the receiver operating characteristic approach instead of using the 95% specificity approach recommended by other authors. The resulting sensitivity and specificity for the group of all lung cancer patients were 65.4% and 84.5% respectively. The sensitivity was highest (76.1%) for squamous cell carcinoma and lowest (44.4%) for SCLC. For NSCLC patients, when CYFRA 21-1 levels were analysed by node (N) factor, patients who presented with mediastinal lymph node metastasis (N2 or N3) demonstrated higher serum CYFRA 21-1 levels (5.6; interquartile range 3.2-11.5 ng ml-1) than patients without mediastinal node metastasis (N0 or N1, 3.9; interquartile range 2.2-10.0 ng ml-1; Mann-Whitney U-test, P = 0.0373). We compared the discriminatory power of CYFRA 21-1 with that of other tumour markers including carcinoembryonic antigen (CEA), squamous cell carcinoma antigen (SCC) and neuron-specific enolase (NSE). The area under the curve (AUC) of each ROC curve was calculated using the CLABROC program for statistical analysis. CYFRA 21-1 appeared to have the most discriminatory power of the markers tested in the diagnosis of lung cancer. In serial measurements of 14 patients receiving chemotherapy or radiotherapy, a high degree of correlation was noted between serum levels of CYFRA 21-1 and extent of clinical response (Wilcoxon, P = 0.0093).

This is a preview of subscription content, access via your institution

Access options

Buy this article

Prices may be subject to local taxes which are calculated during checkout

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Takada, M., Masuda, N., Matsuura, E. et al. Measurement of cytokeratin 19 fragments as a marker of lung cancer by CYFRA 21-1 enzyme immunoassay. Br J Cancer 71, 160–165 (1995). https://doi.org/10.1038/bjc.1995.33

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1038/bjc.1995.33

This article is cited by

Search

Quick links