Introduction

Cancer is one of the deadliest diseases in the world and results in millions of deaths per year.1 Due to its complex nature, many types of cancer currently remain incurable. To overcome the different types of challenges related to the treatment of cancer, a wide range of methods (for example, surgery and radiotherapy) have been introduced. In particular, the use of particles with different functionalities can address some of these challenges, and is a common method for treatment. One example is the metastasis of cancer: while surgery is incapable of removing cells that have spread, particles can be directed at sites that are not accessible to surgery.2, 3, 4 In addition, the use of particles is advantageous over other methods of treatment of cancer in many ways. For example, by administering them orally or by injection, the method is minimally invasive to the human body. These routes of administration are relatively simple to implement and do not require the use of sophisticated equipment (for example, linear accelerators) or highly skilled personnel (for example, surgeons); thus, they can be made widely available to the public. Particles are versatile and can be fabricated in different ways (for example, functionalization with different types of molecules on the surface) for treatment.

However, while the use of particles has been successful in some cases, it has its own set of challenges. When particles are used for delivering molecules (for example, chemotherapy), the molecules are not always effective in performing their intended purposes.5, 6 In addition, some molecules (for example, drugs) may lose their therapeutic efficacy over time as patients develop resistance. When released, molecules tend to diffuse isotropically outward and affect the surrounding healthy cells. In addition to serving as carriers of molecules, other methods that use particles to treat cancer include photothermal therapy and photodynamic therapy. These methods, however, also have their disadvantages, such as limited light penetration and phototoxic response.7, 8, 9 There is thus a need to develop methods that use particles for killing cancer cells effectively.

Here, we propose a fundamentally different approach of using particles for killing cancer cells: by utilizing the physical force derived from the expansion of stimuli-responsive hydrogels to rupture the cells. Stimuli-responsive hydrogels are a class of materials that undergo a chemical transformation—and subsequent expansion or contraction—under the influence of a specific external stimulus. These hydrogels have been studied for many decades and can be fabricated to respond to a wide range of stimuli, including pH, temperature, pressure, electric field, gases, salts, alcohol, glucose and many types of biomolecules (for example, enzymes and antigens).10, 11 On the surface of the stimuli-responsive hydrogel, we coat a layer of cell-adherent molecules. Hence, the basic principle of our approach involves two steps (Figure 1a). First, when the stimuli-responsive hydrogel comes into contact with the cancer cells, the cells attach onto the surface of the hydrogel. After attachment, we expand the hydrogel by introducing an external stimulus. The introduction of an external stimulus, such as a change in temperature (for example, therapeutic hypothermia or hyperthermia therapy) or the use of an electric field, is compatible with several existing treatments of cancer (Supplementary Information, Section 1).12, 13, 14 Subsequently, the physical force that originates from the expansion ruptures the cancer cell. Conceptually, one of the most important fundamental requirements of this approach is that the force produced by the expanding stimuli-responsive hydrogel is large enough to rupture cells attached onto its surface. Therefore, the main objective of this preliminary work is to show experimentally that this physical force is sufficiently large to kill cancer cells (that is, the necessary first step before further development of the technology).

Figure 1
figure 1

Rupturing cancer cells using the physical force of expanding stimuli-responsive hydrogels. (a) Scheme illustrating the process in which the cancer cells first attach onto the surfaces of the stimuli-responsive hydrogels. After the hydrogels expand under the influence of an external stimulus (for example, temperature), the cancer cells rupture. (b) Scheme illustrating the surface modification of the hydrogel. The surface was coated first with a layer of polydopamine (PDA) and poly-L-lysine (PLL) and then with a layer of RGD peptides for attaching the cancer cells. (c) Photographs of the temperature-responsive hydrogels (PNIPAM) with or without surface modification at different temperatures. Nascent hydrogels incubated at 22 °C (top left), and at 37 °C (top right); RGD-modified hydrogels incubated at 22 °C (bottom left) and at 37 °C (bottom right). (d) Comparison of the swelling ratio (SR) and (e) the recovery ratio (RR) of the temperature-responsive hydrogels with and without surface modification.

Materials and methods

Materials

N-Isopropylacrylamide (NIPAM), N,N′-methylenebisacrylamide (BIS), ammonium persulfate (APS), potassium persulfate (KPS), N,N,N′,N′-tetramethylethylenediamine (TEMED), dopamine hydrochloride, poly-L-lysine solution (PLL, 0.1% (w/v) in H2O), poly(ethylene glycol) diacrylate (PEGDA, Mn=575), poly(ethylene glycol) methacrylate (PEGMA, Mn=500), Arg-Gly-Asp (RGD), tris(hydroxymethyl)aminomethane (Tris), Triton-X-100 and trypan blue (0.4%, liquid, sterile-filtered) were purchased from Sigma-Aldrich (Singapore). Anhydrous magnesium sulfate (MgSO4) was purchased from TCI Co., Ltd (Singapore). MDA-MB 231 (ATCC HTB-26) and H358 (ATCC CRL-5807) cells were purchased from American Type Culture Collection. Dulbecco’s modified eagle medium and Roswell Park memorial institute (RPMI) 1640 were purchased from Thermo Fisher Scientific (Singapore). Dulbecco’s phosphate buffered saline (DPBS), fetal bovine serum and penicillin-streptomycin were purchased from HyClone (Singapore). Trypsin-Ethylenediaminetetraacetic acid (EDTA) (0.25%) was purchased from Gibco (Singapore). All chemicals were used as received. The 24-well plates used were Nunc cell-culture-treated multidishes purchased from Thermo Fisher Scientific (Singapore). Cell culture flasks (75 cm2) were purchased from BD Falcon (Singapore). Tris-HCl buffer (pH=8.5, 50 mM) was used for surface modification of hydrogels with PLL and poly(dopamine) (PDA). Phosphate-buffered saline (PBS) (pH=7.4, 10 mM) was used for immobilizing RGD peptides onto the surface of the hydrogels. DPBS (pH=7.4) was used for cell culture experiments. The water used in all experiments was deionized and ultra-filtered to 18 MΩ·cm using a Millipore Milli-Q gradient system.

Fabrication of the macroscopic temperature-responsive hydrogel

Poly(N-isopropylacrylamide) (PNIPAM) hydrogels were synthesized by first preparing (at 22 °C) a 1.5 ml aqueous solution that consisted of 0.10 g of NIPAM and 0.0050 g of BIS. We then added 50 μl of APS (5% w/v) and 30 μl of TEMED into the solution. The suspension was vigorously mixed with a vortex mixer for 10 s and then poured into a poly(styrene) (PS) Petri dish for 20 min at 22 °C. After fabricating the hydrogels, they were washed with ultra-pure water and then freeze-dried (−80 °C, 0.25 mbar) for 4 h.

Surface modification of PNIPAM hydrogels

The coating of the PNIPAM hydrogels with dopamine and PLL followed by another coating of the RGD peptides was performed as follows. First, we prepared a solution for coating the hydrogels by dissolving dopamine hydrochloride and PLL in a Tris-HCl buffer solution (pH=8.5, 50 mM) with a mass ratio of 1:1 (or a concentration of 2 mg ml−1 for each component in the solution). After presoaking the PNIPAM hydrogels in water for 1 h, they were immersed in the solution for coating. The samples were gently shaken for 1 h at 22 °C. We then added RGD in PBS (pH=8.5, 50 mM) directly into the solution; the final concentrations were 1 mg ml−1 dopamine and PLL and 250 μg ml−1 RGD. The reaction was allowed to proceed for another 1 h at 22 °C. The RGD-modified samples were taken out of the solution, washed three times with PBS, washed three times with water, and then stored in water at 4 °C before use.

Fabrication of the microscopic gel particles

Microscopic PNIPAM gel particles (diameter ~15 μm) were prepared by first vigorously mixing a deoxygenated aqueous solution (25 ml) of NIPAM (0.5 ml, 20% w:w), BIS (the cross-linker; 0.75 ml, 20% w:w), and MgSO4 (10 g) for 1 min with a vortex mixer under a nitrogen atmosphere. The resulting emulsion was allowed to stabilize for 15 min. Subsequently, KPS (0.9 ml, 5% w:w) and TEMED (0.5 ml, 20% w:w) were added. The mixture was vigorously mixed for 1 min and then incubated without stirring for 45 min at 25 °C. The microscopic gel particles were collected by centrifugation at 2100 g for 10 min. They were then rinsed with water twice and redispersed in water. Images of the microscopic gel particles were taken by a microscope and an scanning electron microscope (SEM) (FE-SEM, JEOL JSM-6700F). The average diameter of the microscopic gel particles was determined after analyzing the images using ImageJ. Particle size distributions were determined by dynamic light scattering (DLS; Ls 13 320, Beckman Coulter (Singapore)).

We also fabricated microscopic gel particles that were not responsive to temperature. These poly(ethylene glycol) (PEG) gel particles were prepared by the same method as described above for the PNIPAM gel particles, except that the monomer (that is, NIPAM) and the cross-linker (that is, BIS) were replaced with PEGMA and PEGDA, respectively.

Performance of the surface-modified temperature-responsive hydrogel

After coating the surface of the temperature-responsive hydrogel with PDA and PLL and then with arginine-glycine-aspartate (RGD) peptides, we compared its performance with the original hydrogel that was not coated with these molecules.

First, we compared the amount of swelling of the hydrogels with or without surface modification. In this experiment, we placed the hydrogels (diameter of 4.0 mm and height of 300 μm) either with or without surface modification into a Petri dish filled with ultra-pure water and incubated them at different temperatures in the range of 22–37 °C for 24 h. After that, we took the hydrogels out of the solution, removed the excess water on their surfaces with a piece of moistened filter and weighed them. For the dry weight, we prepared another piece of hydrogel, dried it under vacuum at 60 °C overnight and weighed it. We defined the swelling ratio, SR, of the hydrogels as follows:

where Ws is the weight of the hydrogel immersed in water at different temperatures and Wd is the weight of the dry hydrogel.

We also compared the rate of swelling of the temperature-responsive hydrogel with and without surface modification when the temperature was decreased. Experimentally, we first expanded the hydrogels in water at 22 °C and then contracted them in warm water at 37 °C for 1 h. The hydrogels were then immersed back in water at 22 °C; the diameter of the hydrogels was measured at 5 min intervals. We defined the recovery ratio, RR, as follows:

where Dt is the diameter of the hydrogel at time t after immersing it in water at 22 °C and D0 is the diameter of the fully swollen hydrogel at 22 °C and t=35 min.

Cell seeding and static culture on the hydrogels

MDA-MB-231 cells and H358 cells were recovered from liquid N2 and cultured in 75 cm2 cell culture flasks. The solution used consisted of Dulbecco’s modified eagle medium supplemented with 10% fetal bovine serum and 1% penicillin-streptomycin as the growth medium for the MDA-MB-231 cells and RPMI 1640 supplemented with 10% fetal bovine serum and 1% penicillin-streptomycin as the growth medium for the H358 cells. Passaging was done at 80% confluence by washing with DPBS, and the cells were detached using 0.25% trypsin at 37 °C for 5 min.

DPBS (500 μl) was aliquoted into each well of a 24-well plate before individual hydrogels were placed into each well. For comparison, we used two types of temperature-responsive hydrogels: the hydrogels that were not coated and the hydrogels that were coated with RGD peptides. The hydrogels were sterilized by placing the 24-well plate under ultraviolet (UV) irradiation for 30 min. The hydrogels were then shrunk by incubating them at 37 °C for 35 min. The detached cells were first counted using a hemocytometer before centrifuging at 500 g for 5 min and then resuspending them in their corresponding growth medium at 1 × 106 cells per ml. The DPBS in each well was extracted with a pipette and replaced with 400 μl of growth medium preheated at 37 °C. Cells (100 μl) were then carefully pipetted onto the shrunken hydrogels to yield a final concentration of 1 × 105 cells suspended in 500 μl of growth medium. The seeded cells were kept undisturbed for 48 h in a CO2 incubator (5% CO2) at 37 °C before the hydrogels were expanded. For the control experiments, 24-well plates without any hydrogels were used. The concentration was 1 × 105 cells in 500 μl of growth medium per well.

Monitoring cell morphology and cell stain

Cells on the temperature-responsive hydrogels were observed using a microscope (Leica, DFC 300 FX, Wetzlar, Germany) after culturing them for 48 h at 37 °C. The hydrogels were then expanded at 22 °C for 35 min, and the morphologies of the cells were observed during the process at 5 min intervals.

To determine cell death, trypan blue was used to stain the cells. For the two cases in which the macroscopic hydrogels and microscopic gel particles were used, the hydrogels were first allowed to expand at 22 °C for 35 min. We then added 10 times diluted trypan blue solution into the wells. After 3 min, we washed the wells with DPBS three times. The result was examined by a microscope.

Methylthiazolyldiphenyl-tetrazolium bromide (MTT) assay

Cells were first cultured with and without the hydrogels in 24-well plates for 48 h at 37 °C at a concentration of 1 × 105 cells in 500 μl of growth medium per well. For the plates that contained the hydrogels, the hydrogels were expanded at 22 °C for 35 min. For a direct comparison, the plates that did not contain the hydrogels were also kept at 22 °C for 35 min. After that, the cellular culture medium was aspirated and replaced with 500 μl of fresh culture medium. We then added 50 μl of 5 mg ml−1 MTT in PBS to each well; the final concentration of MTT was 0.5 mg ml−1. The cells were then incubated at 37 °C for 4 h. Thereafter, the purple formazan crystals were dissolved by adding 550 μl per well of solubilizing solution (10% (w/v) sodium dodecyl sulfate supplemented with 0.01 M hydrochloric acid (HCl)) into the wells. After incubating the mixture overnight at 37 °C, 1 ml of solubilized formazan was aspirated into fresh 24-well plates, and the results were analyzed by a Wallac 1420 multilabel counter operated at 570 nm. We also performed a control experiment in which we carried out the same procedure except that the hydrogels were not expanded at 22 °C for 35 min; that is, they remained contracted at 37 °C. Hence, we performed three types of experiments: the experiments in which (i) no hydrogel, (ii) a contracted hydrogel and (iii) an expanded hydrogel were used. All of these three experiments were conducted in triplicate. As a control sample for the MTT measurement, we simply used the cell culture medium (that is, without the addition of cells) and treated it similarly with MTT and the solubilizing solution.

To determine the number of dead cells, we translated the number of live cells obtained from the MTT assay into the number of dead cells as follows. First, we determined the number of live cells for the case when there was no hydrogel, LO, from the MTT assay. After conducting the MTT assay three times, we calculated the average number of live cells for the case when there was no hydrogel, . Similarly, we also determined the average number of live cells for the case when the hydrogel was contracted, , and when the hydrogel was expanded, . The number of dead cells were estimated according to Equations (1) and (2).

where NC and NE represent the number of dead cells for the cases when the hydrogel was contracted and when the hydrogel was expanded, respectively.

The diameter of the bottom of each well was 15.6 mm, whereas the diameter of the cylindrical temperature-responsive hydrogel was 4 mm. Since the surface area of the temperature-responsive hydrogel was smaller than the area of the bottom of the well, we did not expect the hydrogel to rupture all the cells attached at the bottom of the well. A method to compare the expected number of dead cells, NA, resulting from the expanding hydrogel is to calculate the fraction of the surface area of the hydrogel over the area of the bottom of the well, and multiply that with the average number of live cells.

where Ahydrogel and Awell represent the surface area of the hydrogel (12.6 mm2) and the bottom of the well (191 mm2), respectively.

Monitoring cell morphology by SEM

The two types of samples were also analyzed by field-emission scanning electron microscopy (FE-SEM, JEOL JSM-6700F, 5 kV): cells attached onto the surface of the fully contracted hydrogel at 37 °C and cells attached onto the surface of the hydrogel after it fully expanded at room temperature. These samples were freeze-dried (–80 °C, 0.25 mbar, 4 h) before analysis.

Measuring the force produced by the expanding hydrogel

Pieces of double-sided tape (STAR) were cut into dimensions of 4 mm in length and 1 mm in width. To increase the strength of the tape, five layers of the tape were stuck on top of each other. They were then attached onto the surface of the contracted hydrogel (cylindrical; 4 mm in diameter and 300 μm in height) using a water acrylic adhesive on both ends of the tape (1 mm2 each). Subsequently, we allowed the contracted hydrogel to gradually expand by placing it in deionized water at 22 °C. We found that the maximum number of tapes that we could adhere onto the hydrogel was five layers; with more layers, the hydrogels bent under the stress of the tape while expanding. We took images of the hydrogel at 3 min intervals while it expanded. Based on these images, we measured the elongation of the attached tape during the initial expansion (6 min) of the hydrogel by Photoshop software. The hydrogel started to bend from 9 min and beyond; hence, we chose to measure the elongation of the tape at 6 min. The expanded length of the tape at 6 min was 0.25 mm.

In a separate step, we determined the force required to elongate the five layers of tape to a length of 0.25 mm. Specifically, we hung the five layers of double-sided tape stuck together vertically and attached the bottom of the tape to a container. In the container, we added a certain number of small loads (that is, acrylonitrile butadiene styrene plastic resin) until the length elongated to 0.25 mm. The elongation was determined by measuring the length under a microscope. After measuring the mass of the total load (that is, the mass of all the small plastic boxes in the container, the container and the copper wire that was used to attach the tape to the container), we determined that the force exerted on the tape was 1.5 N.

This force produced by the expanding hydrogel was based on adhering the five layers of tape with a total adhesive area of 2 mm2 (that is, 1 mm2 on each end of the tape). For a cell with a much smaller surface area, however, the amount of force that the hydrogel can exert is expected to be much smaller. Cells spread and attach onto a substrate via large molecular assemblies called focal adhesion. The total area of focal adhesion in a typical cell can be estimated to be on the order of ~100 μm2, as reported in previous studies.15, 16, 17 For an area of 100 μm2, the force of 1.5 N on an area of 2 mm2 is calculated proportionally to be on the order of ~80 μN for a single cell. This amount of force acting on a cell is much larger than that needed to rupture cells reported in previous studies.

Results and discussion

Fabrication and characterization of the stimuli-responsive hydrogels coated with RGD

For coating the surface of the stimuli-responsive hydrogels with a layer of cell-adherent molecules, we used the arginine-glycine-aspartate (RGD) peptides. It is widely reported in the literature that cells can attach onto surfaces coated with these molecules.18, 19, 20 Experimentally, the RGD peptides can be conjugated onto surfaces via several methods; examples include non-covalent immobilization through hydrophobic interaction,21 biotin–streptavidin interactions,22 van der Waals interaction,23, 24 covalent immobilization through self-assembled monolayers25 and surface-initiated atom transfer radical polymerization.26 However, these methods can be technically complicated, can involve multi-step procedures with long reaction times and/or can immobilize only limited amounts of peptides on the substrates stably.27 Recently, a one-step dopamine-assisted deposition of molecules has been introduced as a simple way to prepare functional surfaces.28 Polymers deposited using this method include dextran, poly(sulfobetaine methacrylate) and several nonionic polymers.29, 30, 31 These depositions, however, have poor chemical stability and poor resistance to acidic solvents because the polymers are not covalently bonded to the PDA. Alternatively, a method has been developed to copolymerize dopamine with polyethyleneimine, which is an amino-rich polymer. Through copolymerization, the stability of the coating can be enhanced.32 However, polyethyleneimine is known to have high cell toxicity.33 In this study, we chose PLL instead, as it is known to have good biocompatibility. Improved adhesion of cells has been shown for surfaces of different materials coated with PLL.34 Based on this rationale, we first copolymerized dopamine and PLL onto the surface of the stimuli-responsive hydrogels and then immobilized RGD peptides onto the coating via a Michael addition or Schiff base reaction (Figure 1b).

As a first demonstration, we fabricated a macroscopic (cylindrical; 4 mm in diameter and 300 μm in height) piece of temperature-responsive hydrogel (poly(N-isopropylacrylamide) (PNIPAM)) with an LCST of approximately 32 °C and modified its surface with a layer of RGD peptides. We verified that the RGD peptides were coated onto the hydrogel by first measuring the contact angle of water (Supplementary Figure S1). When contracted at 37 °C, the hydrogel had significantly different contact angles before and after coating; hence, it seems that the surface was modified. In addition, FTIR results showed that for the hydrogel coated with RGD peptide, a peak corresponding to the COOH group was observed at 1710 cm−1; the appearance of this peak indicates that the RGD was successfully coated onto the hydrogel surface (Supplementary Figure S2). Analysis of the surface using XPS showed that the amount of carbon decreased and the amount of nitrogen increased after coating (Supplementary Figure S3). These measured values are in approximate agreement with the theoretical values of surfaces coated with RGD peptides.

Subsequently, we compared the performance of the temperature-responsive hydrogel before and after coating it with RGD peptides. The ability of the hydrogel to rupture the cancer cells depends on the amount and the rate of expansion. After coating, we found that the diameters of the hydrogel when expanded and contracted were similar to that of the uncoated hydrogel (Figure 1c). The weight of the hydrogel over its dry weight (that is, the swelling ratio) measured at different temperatures and the LCST were also similar (Figure 1d). In addition, the rate of swelling (that is, the recovery ratio) was similar for the coated and uncoated hydrogels (Figure 1e).

Rupturing cancer cells

After fabricating the temperature-responsive hydrogel coated with RGD peptides, we contracted it by incubation at 37 °C. We then seeded either triple-negative breast cancer cells (MDA-MB-231) or non-small cell carcinoma lung cancer cells (H358) onto the hydrogel at 37 °C. After 48 h, we observed that they attached onto the surface of the hydrogels coated with RGD peptides (Figure 2a) but did not attach onto the hydrogels that were not coated with RGD peptides (Supplementary Figure S4). Subsequently, we expanded the temperature-responsive hydrogel by cooling it down to 22 °C (Figure 2 and Supplementary Figure S5). For the MDA-MB-231 cells, we observed a change in morphology of the cells when the hydrogel expanded. Initially, the cells had the characteristic elongated shape, but when the hydrogel expanded, the cells appeared rounded (Figures 2b and e).

Figure 2
figure 2

Cancer cells died after the temperature-responsive hydrogels expanded. Images of breast cancer MDA-MB-231 cells and lung cancer H358 cells on the surface of RGD-modified hydrogels. For the case when (a) the hydrogel was fully contracted by incubating it at 37 °C for 48 h and (b) after the hydrogel was subsequently fully expanded by incubating it at 22 °C for 35 min. (c) Images of the cells after they were stained with trypan blue; dark spots indicate that the cells died. (d) After washing the surface of the RGD-modified hydrogels, the solution collected from washing was imaged. Dark spots were also present. (e) Morphology of MDA-MB-231 cells attached onto the surface of the RGD-modified hydrogel when the hydrogel expanded at low temperature. Images taken at 0, 5, 25, and 35 min after the temperature was reduced to 22 °C.

To determine whether the cells attached onto the hydrogel died after the hydrogel expanded, we stained the cells with trypan blue and washed the surface of the hydrogel three times after staining (see Supplementary Information, Sections 5 and 6, and Supplementary Figures S6–S8, in which we verified that trypan blue stained only dead cells and not live cells). When observed under a microscope, dark blue spots were clearly visible on the surface of the hydrogel—this result indicates that cells died after the hydrogel expanded (Figure 2c). We also collected the solution used to wash the surface of the hydrogel and poured it into a 24-well plate tissue culture polystyrene dish. Similarly, we observed many dark spots in the well under the microscope; these spots represent the debris of the dead cells that was washed away from the surface of the hydrogels (Figure 2d). On the other hand, cells plated on a dish (that is, not on the surface of the coated temperature-responsive hydrogel) did not die when the temperature was decreased to 22 °C for 35 min (Supplementary Information, Section 7, and Supplementary Figure S9).

The conditions of the cells can be observed more clearly using SEM. We analyzed two types of samples: the surface of the fully contracted hydrogel at 37 °C and the surface of the hydrogel after it fully expanded at room temperature. These samples were freeze-dried before analyzing them by SEM. For the fully contracted hydrogel, the images showed that the cells attached on the surface of the hydrogel had morphologies that are typical of the cells (that is, elongated for MDA-MB-231 and rounded for H358; Figure 3a and Supplementary Figure S10). For the fully expanded hydrogel, the images showed debris of materials smaller than the typical size of the cells. These images showed that the cells were ruptured and had broken down into many smaller pieces (Figure 3b and Supplementary Figure S10).

Figure 3
figure 3

SEM images of the cells on the surface of the temperature-responsive hydrogel. (a) Cells attached on the surface of an RGD-modified hydrogel that was fully contracted. (b) After the RGD-modified hydrogels expanded fully, small debris was observed on the surface of the hydrogel. The presence of the debris indicates that the cancer cells ruptured.

To quantify the number of cells that died after the expansion of the hydrogel, we first determined the number of live cells by using the MTT assay. We conducted the MTT assay for three types of experiments: when there was (i) no hydrogel and when the hydrogel was (ii) fully contracted or (iii) fully expanded. The reference number of live cells was based on experiment (i). Hence, the number of dead cells was calculated by taking the difference between the reference (i) and the number of live cells in experiment (ii) or (iii). The results showed that when the hydrogel was fully contracted, there were almost no dead cells. When the hydrogel was fully expanded, a significant number of cells were dead for both types of cells investigated (Figure 4). As a comparison, we can calculate the expected number of dead cells by taking into account the relatively smaller area occupied by the hydrogel in the well. Specifically, if the hydrogel can kill all the cells in the area that it occupies, then the expected number of dead cells is the product of the number of live cells in the well and the fraction of the area of the fully contracted hydrogel in the well. Our results showed that more cells were killed than expected (Figure 4). One explanation is that the hydrogel might have come into contact with more cells during expansion.

Figure 4
figure 4

Quantifying the number of dead cells via the MTT assay. The plots show the number of dead cells for (a) MDA-MB-231 cells and (b) H358 cells. (1) Cells attached on 24-well plates without any hydrogel. Cells attached on temperature-responsive hydrogels that were (2) fully contracted and (3) fully expanded. (4) The expected number of dead cells in the well calculated based on the product of the expected number of live cells and the fractional area of the hydrogel over the bottom area of the well.

Measuring the physical force

The results of these experiments indicate that the force provided by the expanding temperature-responsive hydrogel was sufficient for rupturing the cancer cells. However, the fundamental mechanism of how the PNIPAM hydrogel expands when the temperature is lowered is not completely understood at the molecular level.35, 36 One explanation is based on the hydrophobic groups (that is, the isopropyl groups and the polymeric backbone) and the hydrophilic groups (that is, the amide groups) of the PNIPAM hydrogel. At low temperature, the polymeric chains adopt an extended conformation stabilized by hydrogen bonding between the hydrophilic groups of the polymer and the water molecules. These water molecules, however, need to arrange themselves in an ordered manner around the polar and nonpolar regions of the polymeric chains, thus resulting in a decrease in entropy.37 At high temperature, the interaction between the polymer and the water molecules reduced.38, 39 In this case, entropy dominates: water is expelled out of the hydrogel, and the polymeric chains adopt a collapsed globule-like conformation.

Since the fundamental mechanism is not completely understood, we performed an experiment to determine the magnitude of the force produced by the expansion of the temperature-responsive hydrogel. We first adhered multiple layers of double-sided tape onto the surface of the hydrogel and then allowed the hydrogel to expand for 6 min (Figure 5a). For five layers of tape, the hydrogel was able to stretch it for 0.25 mm without bending under the stress of the tape. Subsequently, we determined the amount of load required to elongate the five layers of tape to the same length (Figure 5b). Briefly, we attached a container to the bottom of the tape and filled the container with small loads (that is, polymeric cubes) until the tape elongated to the same length (that is, 0.25 mm). By measuring the weight of the total load (~1.5 N) and taking into account the small adhesive area of a cell, we estimated that a force on the order of ~80 μN can act on a single cell. This force is much larger than that typically needed to rupture a cell.40, 41, 42 In addition, a stimuli-responsive hydrogel exerts the largest force when it starts expanding initially (and does not exert any force after it fully expanded); hence, we expect the force to be larger for an expansion less than 0.25 mm (for example, for the distance required to rupture the cell membrane).

Figure 5
figure 5

Measuring the lateral force of the surface of the expanding temperature-responsive hydrogel. (a) Five layers of double-sided tape were adhered onto the surface of the hydrogel (image on the left). The hydrogel was allowed to expand and stretch the tape for 6 min (image on the right). (b) Scheme illustrating the method for measuring the force required to stretch the tape to the same length as the hydrogel.

Rupturing cells using microscopic particles

In addition to using the macroscopic pieces of hydrogels, we demonstrated that microscopic (diameter ~15 μm) temperature-responsive gel particles can also rupture cancer cells (see Supplementary Figures S11–S12 for SEM images and the size distributions of the particles). These gel particles were similarly coated with PLL and PDA and then with RGD peptides. For rupturing the cancer cells, we first added them into a 24-well plate and allowed the cells to attach onto the bottom surface of the dish at 37 °C for 24 h (Figure 6a). We then added the microscopic gel particles into the wells. After another 24 h, we allowed the gel particles to expand at a low temperature of 22 °C for 35 min (Figure 6b). Subsequently, the cells were stained with trypan blue. Dark blue spots were present after the gel particles expanded (Figures 6c and d); hence, the cells died due to the expansion of the particles. To show that the microscopic particles themselves did not cause cell death (that is, without expansion), we fabricated another type of gel particle that did not change its size with a change in temperature (Supplementary Figures S11–S12). When these gel particles were used, no dark spots were present (Figures 6e and f).

Figure 6
figure 6

Using microscopic temperature-responsive gel particles for rupturing cancer cells. (a) Images of the cells and the RGD-modified microscopic temperature-responsive gel particles after incubating them at 37 °C for 24 h and (b) after subsequently expanding the gel particles at 22 °C for 35 min. Images of the cells and the gel particles located (c) in the center and (d) by the sides of the 24-well plates after expanding the gel particles and staining the remains of the cells with trypan blue. (e) Images of the cells and the gel particles that were not responsive to temperature after incubating them at 22 °C for 35 min. (f) Images of the cells and the gel particles that were not responsive to temperature after staining with trypan blue.

Conclusions

We showed that the physical force derived from the chemical transformation and the subsequent expansion of a temperature-responsive hydrogel is strong enough to rupture cancer cells. To adhere the cells onto the hydrogels, we developed a method to deposit RGD peptides (that is, peptides that are commonly used for adhering cells onto a substrate) onto the surface of the hydrogels via copolymerizing the biocompatible PDA and PLL macromolecules. Since the cancer cells died after expansion, it seems that the adhesion provided by the RGD molecules is firm enough for rupturing the cells. Another advantage of using RGD peptides is that previous studies have used these RGD peptides for targeting cancer cells or tumor sites.43, 44 The amount and the rate of expansion of the temperature-responsive hydrogels after coating remained unchanged. Experimentally, we measured that the force of the expanding hydrogel was greater than the typical force needed to rupture cells. The lysis tensions of cell membranes of different types of cells typically lie within a narrow range (for example, on the order of 1 mN m−1 to 10 mN m−1).41, 42, 45, 46 Therefore, this approach may potentially be general for rupturing a wide range of cells.

This approach has several other advantages. Both macroscopic (~mm) and microscopic (~15 μm) hydrogels were demonstrated to work; hence, particles of other sizes that are within this range may potentially be used with similar effects. As such, this approach has many of the advantages of using particles for treating cancer (for example, minimally invasive, easily administered and applicable to different parts of the body). For example, microscopic hydrogels injected intravenously into mice were found to have long circulation times and have been proposed to be used for therapeutic purposes.4 On the other hand, it may be challenging for smaller gel particles (for example, those on the order of a few hundred nanometers) to be effective due to other complications (for example, the fluidity of the cell membrane and endocytosis). Another advantage of this approach is that stimuli-responsive hydrogels are generally regarded as ‘smart’ drug carriers in the field of drug delivery that can target a specific site.47, 48 For example, the tumor microenvironment is known to be acidic and has a slightly elevated temperature.49, 50 A temperature-responsive and/or a pH-responsive hydrogel can target the tumor site specifically by expanding only at the localized site, thereby reducing damage to healthy cells.

After establishing that the physical force derived from the expanding hydrogel is sufficient for rupturing cancer cells, more work will be needed to further develop the technology. For example, specific targeting of cancer cells can potentially be achieved by replacing the RGD coating with molecules that bind specifically to cancer cells.51, 52, 53 For this approach to be compatible with existing methods for treating cancer (for example, therapeutic hypothermia, hyperthermia therapy, or the use of an electric field; see Supplementary Information, Section 1), different types of stimuli-responsive hydrogels may need to be fabricated (for example, hydrogels that expand at high temperature or respond to an electric field).54, 55 Fully biocompatible materials (for example, biocompatible temperature-responsive hydrogel) will also be needed.56 There will be many challenges ahead before this technology can be implemented in practical circumstances; examples include fabricating the coated stimuli-responsive hydrogel with all the required material properties (for example, biocompatibility of the hydrogel and coating, specificity of the coating for targeting cancer cells, and sufficient response) so that they are effective in a complex in vivo environment.

Although more work needs to be done before we can fully assess the effectiveness of this approach, it has characteristics that are promising compared to other methods (that is, those that also use particles). Importantly, the approach involves a fundamentally different mechanism—a physical force. Based on our analyses, this approach can potentially be general for a wide range of cells. In addition, it is conceptually simple and is technically easy to implement (for example, preparation of the hydrogel is simple). In comparison, other chemical (for example, chemotherapy) and biological (for example, immunotherapy) methods may require a combination of complex organic synthesis of (for example, drug) molecules, extensive testing of the effectiveness of each of the synthesized molecules, and fundamental knowledge of the underlying biomolecular mechanism for killing specific types of cancer cells. Because of these advantageous characteristics, it will be interesting to develop the technology further and fully compare these features with other methods.