Abstract
There is scant information pertaining to airborne ammonia exposures from either spills or common household uses of ammonia-containing floor and tile cleaners or from spray-on glass cleaners. We assessed instantaneous and event-specific time-weighted average (TWA) exposures to airborne ammonia during spills and use (per label directions) of a household floor and tile cleaner and two spray-on window cleaners. Airborne ammonia levels measured at breathing zone height (BZH) above the spilled floor and tile cleaner product reached 500 p.p.m. within 5 min, while levels for spilled window cleaner were below 8 p.p.m. TWA exposures were assessed while tile walls and floors were cleaned in three different bathrooms of a residence, and during use of a spray-on glass cleaner while washing several large windows in an office setting. NIOSH Method 6015 was utilized with concurrent field measurements every 60 s using a Drager PAC III monitor with an electrochemical cell detector. Peak ammonia levels ranged from 16 to 28 p.p.m. and short-term TWA concentrations ranged from 9.4 to 13 p.p.m. during mixing (0.1% ammonia) and cleaning tiles in the three bathrooms. Ammonia exposures while using spray-on window cleaner were over 10-fold lower (TWA=0.65 p.p.m.). Use of the floor and tile cleaner mixed at 0.2% ammonia led to peak airborne ammonia levels within 3–5 min at 36–90 p.p.m., and use of full strength cleaner (3% ammonia) led to peak ammonia levels of 125 to >200 p.p.m. within 2–3 min. Spillage or intentional use of the full strength floor and tile cleaner led to airborne ammonia concentrations that exceed occupational short-term exposure limits, while spillage or use of the spray-on window cleaner did not approach potentially hazardous airborne ammonia levels and likely represents a minimal inhalation health hazard. We conclude that routine household uses of ammonia are unlikely to produce significant exposures when using standard cleaning solutions (0.1–0.2%), but spillage or use of concentrated ammonia solutions (e.g., 3%) in poorly ventilated areas can lead to potentially hazardous airborne ammonia exposures.
This is a preview of subscription content, access via your institution
Access options
Subscribe to this journal
Receive 6 print issues and online access
$259.00 per year
only $43.17 per issue
Buy this article
- Purchase on SpringerLink
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout
Similar content being viewed by others
References
ACGIH (American Conference of Governmental Industrial Hygienists). Ammonia. CAS number 7664-41-7, 2001.
AIHA (American Industrial Hygiene Association). Emergency Response Planning Guidelines. Ammonia, Fairfax, VA, 2001.
Aneja V.P., Murthy A.B., Battye W., Battye R., and Benjey W.G. Analysis of ammonia and aerosol concentrations and deposition near the free troposphere at Mt. Mitchell, NC, USA. Atmos Environ 1998: 32 (3): 353–358.
ATSDR (Agency for Toxic Substances and Disease Registry). DRAFT Toxicological Profile for Ammonia. US Department of Health and Human Services, Public Health Service, 2002.
Ballal S.G., Ali B.A., Albar A.A., Ahmed H.O., and al-Hasan A.Y. Bronchial asthma in two chemical fertilizer producing factories in eastern Saudi Arabia. Int J Tuberc Lung Dis 1998: 2 (4): 330–335.
Bradstrut R.B The Kjeldahl Method for Organic Nitrogen. Academic Press, New York, 1965.
Cole T.J., Cotes J.E., Johnson G.R., Martin H.D., Reed J.W., and Saunder J.E. Ventilation, cardiac frequency and pattern of breathing during exercise in men exposed to o-chlorobenzylidene malonitrile (CS) and ammonia gas in low concentrations. Q J Exp Physiol Cogn Med Sci 1977: 63: 341–351.
Crutzen P.J. Atmospheric interactions—homogeneous gas reactions of C N, and S containing compounds. In: Bolin B., and Cook R.B. (Eds.). The Major Biogeochemical Cycles and their Interactions. John Wiley & Sons, Chichester, 1983, pp. 67–113.
Dawson G.A., and Farmer J.C. Highly soluble atmospheric trace gases in the Southwestern United States. I. Inorganic Species: NH3, HNO3, SO3. J Geophys Res 1984: 89 (D3): 4779–4787.
Fangmeier A., Hadwiger-Fangmeier A., Van Der Eerden L., and Jager H.J. Effects of atmospheric ammonia on vegetation: a review. Environ Pollut 1994: 86 (1): 43–82.
Farmer J.C., and Dawson G.A. Condensation sampling of soluble atmospheric trace gases. J Geophys Res 1982: 87 (C11): 8931–8942.
Ferguson W.S., Koch W.C., Webster L.B., and Gould J.R. Human physiological response and adaption to ammonia. J Occup Med 1977: 19: 319–326.
Georgii H.W., and Gravenhorst G. The ocean as source or sink of reactive trace-gases. Pure Appl Geophys 1977: 115: 503–511.
Harward C.N., McClenny W.A., Hoell J.M., Williams J.A., and Williams B.S. Ambient ammonia measurements in coastal Southeastern Virginia. Atmos Environ 1982: 16 (10): 2497–2500.
Holness D.L., Purdham J.T., and Nethercott J.R. Acute and chronic respiratory effects of occupational exposure to ammonia. Am Ind Hyg Assoc J 1989: 50 (12): 646–650.
Industrial Bio-Test Laboratories, Inc. 1973. Irritation threshold evaluation study with ammonia. Report to International Institute of Ammonia Refrigeration (IBT No. 663-03160), Northbrook, IL; March 23, 1973 Industrial Bio-Test Laboratories, Inc. [unpublished study to be peer reviewed].
Integrated Risk Information System (IRIS). Ammonia, US Environmental Protection Agency, 2003.
Kelly T.J., Tanner R.L., Newman L., Galvin P.J., and Kadlecek J.A. Trace gas and aerosol measurements at a remote site in the Northeast US. Atmos Environ 1984: 18 (12): 2565–2576.
MacEwen J.D., Theodore J., and Vernot E.H. Human exposure to EEL concentrations of monomethylhydrazine. Proceedings of 1st Annual Conference on Environmental Toxicology, AMRL-TR-70-102, Paper 23, September 1970; Wright-Patterson Air Force Base, Dayton, Ohio, 1970.
National Academy of Sciences. Guideline for Short Term Exposures of the Public to Air Pollutants. IV. Guide for Ammonia by the National Research Council, Committee on Toxicology. National Academy Press, Washington, DC, 1987.
Nazaroff W.W., and Weschler C.J. Cleaning products and air fresheners: exposure to primary and secondary air pollutants. Atmos Environ 2004: 38 (4): 2841–2865.
NIOSH (National Institute for Occupational Safety and Health). Criteria for a Recommended Standard – Occupational Exposure to Ammonia. DHEW Pub. No. 74-136, DHHS Pub. No. 97-106, NTIS No. PB-502-082, 1997.
Russell A.G., McCue K.F., and Cass G.R. Mathematical modeling of the formation of nitrogen-containing air pollutants. 1. Evaluation of an Eulerian photochemical model. Environ Sci Technol 1988: 22: 263–271.
Sekizawa S.I., and Tsubone H. Nasal receptors responding to noxious chemical irritants. Respir Physiol 1994: 96 (1): 37–48.
Silverman L., Whittenberger J.L., and Muller J. Physiological response of man to ammonia in low concentrations. J Ind Hyg Toxicol 1949: 31: 74–78.
Tanner RL An ambient experimental study of phase equilibrium in the atmospheric system: aerosol H+, NH+4, SO2−4, NO−3-NH3(g), HNO3(g) . Atmos Environ 1982: 16 (12): 2935–2942.
Verberk M.M. Effects of ammonia in volunteers. Int Arch Occup Environ Health 1977: 39: 73–81.
Vigliani E.C., and Zurlo N. Experiences of the clinical del Lavero with maximum allowable concentrations of industrial poisons. Arch Gewerbepath U Gewerbehyg 1956: 13: 528–535.
Watson W.A., Litovitz T.L., Rodgers G.C., Klein-Schwartz W., Youniss J., Rose S.R., Borys D., and May M.E. 2002 Annual report of the American Association of Poison Control Centers Toxic Exposure Surveillance System. Am J Emerg Med 2003: 21 (5): 353–421.
Webb A.M., Singer B.C., and Nazaroff W.W. Effect of gaseous ammonia on nicotine sorption. Proceedings, Indoor Air 2002 Conference, 2002, pp. 512–517.
WHO (World Health Organization). Ammonia Environmental Health Criteria, Vol. 54. World Health Organization, Geneva, Switzerland, 1986.
Acknowledgements
Special thanks to Roxanne Agredano and Richard Richter for their valuable assistance. The measurement studies were funded by the legal counsel for an industrial defendant to characterize common consumer exposures to ammonia. Neither of the products tested was at issue in the litigation and no funding was received from cleaner product manufacturers. The individual authors funded the literature review and creation of this manuscript.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Fedoruk, M., Bronstein, R. & Kerger, B. Ammonia exposure and hazard assessment for selected household cleaning product uses. J Expo Sci Environ Epidemiol 15, 534–544 (2005). https://doi.org/10.1038/sj.jea.7500431
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/sj.jea.7500431
Keywords
This article is cited by
-
Rapid ammonia build-up in small individually ventilated mouse cages cannot be overcome by adjusting the amount of bedding
Lab Animal (2023)
-
Nonlinear fourth-order elastic characterization of the cornea using torsional wave elastography
Physical and Engineering Sciences in Medicine (2023)
-
Torsional wave elastography to assess the mechanical properties of the cornea
Scientific Reports (2022)
-
Synthesis of H2SO4-doped polyaniline materials and behavior of enhancing gas sensing properties
Journal of Materials Science: Materials in Electronics (2022)
-
A Green Approach for Complexometric Titration*
Resonance (2022)