Skip to main content

Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

  • Original Article
  • Published:

Air concentrations of VOCs in portable and traditional classrooms: Results of a pilot study in Los Angeles County

Abstract

Recent state and federal public school class-size reduction initiatives, increased elementary and pre-K enrollment driven by population growth and immigration, and limited resources for capital projects, modernization, and maintenance at aging schools have increased the prevalence of prefabricated, portable classrooms (portables). At present, approximately one of three California students are taught in portables, whose use is especially prevalent in more populated counties such as Los Angeles, home to the nation's second largest school district. Limited data existed on chemical compound air concentrations, and thus exposures, inside American public schools. Measurements have been limited, usually performed in complaint schools, and varied in sampling protocols and analysis methods. To address a school environment and children's health issue of present concern, an assessment of public school portables was conducted in Los Angeles County. Seven schools in two school districts were recruited, from which 20 classrooms — 13 portables, seven in main buildings — were randomly selected. We report indoor air concentrations of 21 target toxic and odorous volatile organic compounds (VOCs), including formaldehyde and acetaldehyde, measured with passive samplers (DNSH PAKS and 3M OVM 3500) in the cooling and heating seasons between June 2000 and June 2001. None of the measured indoor air formaldehyde concentrations exceeded the existing California Air Resources Board guideline (50 ppb, or 60 μg/m3). The main sources of aldehydes in classrooms, especially portables, were likely interior finish materials and furnishings made of particleboard without lamination. Indoor air VOC concentrations were generally low in this pilot study. The four most prevalent VOCs measured were toluene, m-/p-xylene, α-pinene, and δ-limonene; likely indoor sources were personal, teaching, and cleaning products. Future schools research should attempt larger samples over larger geographical areas.

This is a preview of subscription content, access via your institution

Access options

Rent or buy this article

Prices vary by article type

from$1.95

to$39.95

Prices may be subject to local taxes which are calculated during checkout

Similar content being viewed by others

References

  • Ahman M., Lundin A., Musabasic V., and Soderman E . Improved health after intervention in a school with moisture problems. Indoor Air 2000: 10: 57–62.

    Article  CAS  Google Scholar 

  • American Public Health Association. Policy statement no. 200010: Creating Healthier School Facilities. Am J Public Health 2001: 91(3): 19–20.

  • Auditor General. Portable Classrooms in California School Districts: Their Safety, Uses, Cost, and the Time it Takes to Acquire Them. September 1991.

  • California Air Resources Board (CARB). Indoor Air Quality Guideline No.1: Formaldehyde in the Home. September 1991. http://www.arb.ca.gov/research/indoor/formald.htm

  • CARB. Acetaldehyde as a Toxic Air Contaminant: Executive Summary. CARB, Stationary Source Division, Sacramento, CA, November 1993.

  • CARB. Indoor Air Quality Guideline No. 3: Chlorinated Chemicals in Your Home. May 2001. http://www.arb.ca.gov/research/indoor/clguide.pdf

  • California Department of Education (CADE). 1999–2000 Title VI Guidance Federal Class Size Reduction Program. May 1999. (1999a) http://www.cde.ca.gov/ftpbranch/sfpdiv/classize/federal/guidance.html. Also see Public Schools Accountability Act of 1999, California State Education Code Section 52120. http://www.leginfo.ca.gov/calaw.html

  • Carrer P., Bruinen de Bruin Y., Franchi M., and Valovirta E . The EFA project: indoor air quality in European schools. Proceedings of the Ninth International Conference on Indoor Air Quality and Climate Vol., 2, Monterey, CA, 794–799, 2002.

  • Cavallo D., Alcini D., De Bortoli M., Carrettoni D., Carrer P., Bersani M., and Maroni M. Chemical contamination of indoor air in schools and office buildings in Milan, Italy. Proceedings of the Sixth International Conference of Indoor Air Quality and Climate, Helsinki, Finland, Vol. 2, 45–50, 1993.

  • Chung C-W., Morandi M.T., Stock T.H., and Afshar M . Evaluation of a passive sampler for volatile organic compounds at ppb concentrations, varying temperatures, and humidities with 24-h exposures: 1. Description and characterization of exposure chamber system. Environ Sci Technol 1999a: 33(20): 3661–3665.

    Article  CAS  Google Scholar 

  • Chung C-W., Morandi M.T., Stock T.H., and Afshar M . Evaluation of a passive sampler for volatile organic compounds at ppb concentrations, varying temperatures, and humidities with 24-h exposures: 2. Sampler performance. Environ Sci Technol 1999b: 33(20): 3666–3671.

    Article  CAS  Google Scholar 

  • Cohen Hubal E.A., Sheldon L.S., Burke J.M., McCurdy T.R., Berry M.R., Rigas M.L., Zartarian V.G., and Freeman N.C . Children's exposure assessment: a review of factors influencing children's exposure, and the data available to characterize and assess that exposure. Environ Health Perspect 2000: 108(6): 475–488.

    Article  CAS  Google Scholar 

  • Consumer Product Safety Commission (CPSC). An update on formaldehyde: 1997 Revision. CPSC Document #725. http://www.cpsc.gov/cpscpub/pubs/725.html

  • Daisey J., and Angell W.J . A Survey and Critical Review of the Literature on Indoor Air Quality, Ventilation, and Health Symptoms in Schools. E.O. Lawrence Berkeley National Laboratory, Environmental Energy Technologies Division, Indoor Environment Department, Berkeley, CA, March 1998: LBNL-41517

  • Daisey J.M., Angell W.J., and Apte M.G . Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information. Indoor Air 2003: 13(1): 53–64; LBNL-48287

    Article  CAS  Google Scholar 

  • Devos M., Patte F., Rouault J., Laffort P., and Van Gemert L.J . Standard Human Olfactory Thresholds. Oxford University Press, Oxford, 1990.

    Google Scholar 

  • EdSource. “Portable School Buildings: Scourge, Saving Grace, or Just Part of the Solution?” 1998. http://www.edsource.org/pub_edfct_port.html.

  • Education Writers Association. Wolves at the Schoolhouse Door. Washington, DC, 1989.

  • Fielder N., Zhang J., Fan Z., Kelly-McNeil K., Lioy P., Gardner C., Ohman-Strickland P., and Kipen H . Health effects of a volatile organic compound mixture with and without ozone. Proceedings of the Ninth International Conference on Indoor Air Quality and Climate, Vol. 2, Monterey, CA, 2002, pp. 596–601.

  • Fontana C., Stetzenbach L., Cruz P., Braganza E., and Harrison J . Baseline indoor air quality pollutant characterization in five United States schools. Proceedings of Healthy Buildings 2000, Vol. 1, Espoo, Finland, 2000, pp. 555–560.

  • Garrett M.H., Hooper M.A., Hooper B.M., Rayment P.R., and Abramson M.J . Increased risk of allergy in children due to formaldehyde exposure in homes. Allergy 1999: 54 (4): 330–337.

    Article  CAS  Google Scholar 

  • Green G.H . The effect of indoor relative humidity on absenteeism and colds in schools. ASHRAE Transactions 1974: 80(II): 131–141.

    Google Scholar 

  • Green G.H . Indoor relative humidities in winter and the related absenteeism. ASHRAE Transactions 1985: 91(1B): 643–653.

    Google Scholar 

  • Hansen L.B.E., Ibsen K., and Osterballe K . Carpeting in schools as an indoor pollutant. Proceedings of the Fourth International Conference of Indoor Air Quality and Climate, Vol. 2, Berlin, West Germany, 1987, pp. 727–731,

  • Heath G.A., and Mendell M.J . Do indoor environments in schools influence student performance? A review of the literature. Proceedings of the Ninth International Conference of Indoor Air Quality and Climate, Vol. 1, Monterey, CA, 2002, pp. 802–807.

  • Heindel J . Learning disabilities association-sponsored symposium on chemical hormone impostors and child development. Environ Health Perspect 2000: 108(8): 785–786.

    Article  CAS  Google Scholar 

  • Hodgson A.T., Wooley J.D., and Daisey J.M . Emissions of volatile organic compounds from new carpets measured in a large-scale environmental chamber. J Air Waste Manage Assoc 1993: 43(3): 316–324.

    Article  CAS  Google Scholar 

  • Hodgson A.T., Fisk W.J., Shendell D.G., and Apte M.G . Predicted Concentrations in New Relocatable Classrooms of Volatile Organic Compounds Emitted from Standard and Alternate Interior Finish Materials. E.O. Lawrence Berkeley National Laboratory, Environmental Energy Technologies Division, Indoor Environment Department, Berkeley, CA, July 2001: LBNL-48490.

  • Instruction for Use — Organic Vapor Monitors (OVM) 3520/3530. St. Paul, MN: 3M Occupational Health and Environmental Safety Division (3M), 1991.

  • Jaakkola J.J.K., Oie L., Nafstad P., Botten G., Samuelsen S.O., and Magnus P . Interior surface materials in the home and the development of bronchial obstruction in young children in Oslo, Norway. Am J Public Health 1999: 89(2): 188–192.

    Article  CAS  Google Scholar 

  • Jaakkola J.J.K., Verkasalo P.K., and Jaakkola N . Plastic wall materials in the home and respiratory health in young children. Am J Public Health 2000: 90(5): 797–799.

    Article  CAS  Google Scholar 

  • Jacobson L . 1998. Early-grade centers ease space woes. Education Week, October 14. http://www.edweek.com/ew/1998/07primar.h18

  • Kelly T.J., Smith D.L., and Satola J . Emission rates of formaldehyde from materials and consumer products found in California homes. Environ Sci Technol 1999: 33(1): 81–88.

    Article  CAS  Google Scholar 

  • Kennedy M . Bursting through: how schools are meeting the enrollment explosion. Am School Univ 1999: 71(9): 18–20, 22, 24, 26.

    Google Scholar 

  • Kirchner S., Pasquier N., Cretier D., Gauvin S., Golliot F., Pietrowski D., and Cochet C . The French permanent survey on indoor air quality survey design in dwellings and schools. Proceedings of the Ninth International Conference on Indoor Air Quality and Climate, Vol. 4, Monterey, CA, 2002, pp. 449–454.

  • Klenø J.G., Wolkoff P . Eye irritation from exposure to ppb levels of limonene oxidation products. Proceedings of the Ninth International Conference on Indoor Air Quality and Climate, Vol. 2, Monterey, CA, 2002, pp. 602–607.

  • Lewis C.W . Sources of air pollutants indoors: VOC and fine particulate species. J Expos Anal Environ Epidemiol 1991: 1(1): 31–44.

    CAS  Google Scholar 

  • Meyer H.W.A.L., Nielsen J.B., Hansen M.O., Gravesen S., Nielsen P.A., Skov P., and Gyntelberg F . Building conditions and building-related symptoms in the Copenhagen school study. Indoor Air 1999: 2: 298–299.

    Google Scholar 

  • National Center for Education Statistics (NCES). Condition of America's Public School Facilities: 1999 (Statistical Analysis Report). United States Department of Education (USDOEd), Office of Educational Research and Improvement, June 2000, NCES 2000-032.

  • NCES. Early Estimates of Public Elementary and Secondary Education Statistics: School Year 2000–01. USDOEd, Office of Educational Research and Improvement, February 2001 (2001a), NCES 2001-331.

  • NCES. Revenues and Expenditures for Public Elementary and Secondary Education: School Year 1998–99 (Statistics in Brief). USDOEd, Office of Educational Research and Improvement, March 2001 (2001b), NCES 2001-321.

  • NCES. Overview of Public Elementary and Secondary Schools and Districts: School Year 1999–2000 (Statistical Analysis Report). USDOEd, Office of Educational Research and Improvement, August 2001 (2001c), NCES 2001-339.

  • NCES. Characteristics of the 100 Largest Public Elementary and Secondary School Districts in the United States: 1999–2000. USDOEd, Office of Educational Research and Improvement, October 2001 (2001d), NCES 2001-346.

  • NCES. Digest of Education Statistics, 2000. USDOEd, Office of Educational Research and Improvement, 2001 (2001e). http://nces.ed.gov/pubs2001/digest/ch2.html

  • NCES. Characteristics of the 100 Largest Public Elementary and Secondary School Districts in the United States: 2000–01. USDOEd, Office of Educational Research and Improvement, September 2002. http://nces.ed.gov/pubs2002/2002351.pdf. NCES 2002-351.

  • National Education Association (NEA). Legislative Action Center: School Modernization Facts, California. http://www.nea.org/lac/modfacts/Cafacts.html Internet, accessed November 22, 2000.

  • Naylor C . Teacher Safety in Portable Classrooms. British Columbia Teacher's Federation Research Department (BCTFRD), 1997. http://www.bctf.bc.ca/ResearchReports/97wlc01/

  • Nikolic M . Indoor air quality in primary schools. Proceedings of Healthy Buildings 2000, Vol. 1, Espoo, Finland, 2000, pp. 455–458.

  • Office of Environmental Health Hazard Assessment (OEHHA), California Environmental Protection Agency (CalEPA). 2000. Air: Acute Reference Exposure Levels (RELs), Averaging Times, and Toxicological Endpoints. Internet, http://www.oehha.org/air/acute_rels/allAcRELs.html

  • OEHHA, CalEPA. 2001a. Air: Chronic RELs. Internet, http://www.oehha.org/air/chronic_rels/AllChrels.html

  • OEHHA, CalEPA. 2001b. Prioritization of Toxic Air Contaminants — Children's Environmental Health Protection Act: Final Report. Internet, October 19, 2001, http://www.oehha.ca.gov/air/toxic_contaminants/SB25finalreport.htm

  • Pepler R.D.W . Temperature and learning: An experimental study. ASHRAE Transactions 1968: 74: 211–219.

    Google Scholar 

  • Rohr A.C., Wilkins C.K., Clausen P.A., Hammer M., Nielsen G.D., Spengler J.D., and Wolkoff P . Upper airway and pulmonary effects of terpene oxidation products in BALB/c mice. Proceedings of the ninth International Conference on Indoor Air Quality and Climate, Vol. 2, Monterey, CA, pp. 2002, 590–595.

  • Ross Z.A. and Walker B . Reading, Writing, and Risk: Air Pollution Inside California's Portable Classrooms. Environmental Working Group, for State of California, May 1999.

  • Sahlberg B., Smedje, and Norback D . Sick building syndrome (SBS) among school employees in the county of Uppsala, Sweden. Proceedings of the Ninth international Conference on Indoor Air Quality and Climate, Vol. 3, Monterey, CA, 2002 pp. 494–499.

  • Schneider T., Lorinci G., Gebefugi I.L., Heinrich J., Kettrup A. and Wichmann H-E. Vertical and horizontal variability of volatile organic compounds in homes in Eastern Germany. J Expos Anal Environ Epidemiol 1999: 9(4): 282–292.

    Article  CAS  Google Scholar 

  • Shendell D.G. “Assessment of Organic Compound Exposures, Thermal Comfort Parameters, and HVAC System-Driven Air Exchange Rates in Public School Portable Classrooms in California.” D. Env. dissertation. School of Public Health, Environmental Science and Engineering Program, University of California, Los Angeles, 2003a.

  • Shendell D.G . Rapid assessments for school facility management programs: results of technician walk-through checklists conducted during California school indoor air and environment studies. School Plann Manage, 2003b, submitted for publication.

  • Shendell D.G . Are modular classroom HVAC system issues related to communication gaps about operations and maintenance? Results of an interview questionnaire conducted during California school indoor air and environment studies. School Plann Manage, 2003c, submitted for publication.

  • Shendell D.G., Winer A.M., Colome S.D., and Weker R. Evidence of inadequate ventilation in portable classrooms: Results of a pilot study in Los Angeles County. Indoor Air, 2003, submitted for publication.

  • Smedje G., and Norbäck D. Factors affecting the concentration of pollutants in school buildings. Proceedings of the Eighth International Conference on Indoor Air Quality and Climate, Edinburgh, Scotland, Vol. 1, 1999, pp. 267–272.

  • Smedje G., and Norback D . New ventilation systems at select schools in Sweden — Effects on asthma and exposure. Arch Environ Health 2000: 55(1): 18–25.

    Article  CAS  Google Scholar 

  • State of California. Proposition 8, “Permanent Class Size Reduction and Educational Opportunities Act.” 1998. http://www.sen.ca.gov/sor/props/Prop8.htm

  • Stone D., and Agee J . Facilities Fund Released for Class Size Reduction. Sacramento, CADE, October 23, 1996. http://www.cde.ca.gov/ftpbranch/sfpdiv/classize/press/press9663.htm

  • Sturgeon J . Fixed facts about portable classrooms. School Plann Manage 1998: 37(7): 37–38, 40–41.

    Google Scholar 

  • Torres V., Sanders M., and Corsi R . Texas elementary school indoor air study (TESIAS): overview and major findings. Proceedings of the Ninth International Conference on Indoor Air Quality and Climate, Vol. 2, Monterey, CA, 2002, pp. 80–85.

  • Unauthored. A healthy home environment. Environ Health Perspect 1999: 107 (7): A352–A357.

  • USDOEd. Digest of Education Statistics. NCES, Washington, D.C, 1997a.

  • USDOEd. Projections of Education Statistics to 2007. NCES, Washington, D.C, 1997b.

  • USEPA. Environmental Health Threats to Children. Office of the Administrator, September 1996, EPA 175-F-96-001.

  • USEPA. Strategy for Research on Environmental Risks to Children. Office of Research and Development, October 2000, EPA/600/R-00/068

  • USEPA. Indoor Air Quality: Formaldehyde. Internet, accessed August 3, 2002, http://www.epa.gov/iaq/formalde.html

  • Wainman T., Zhang J., Weschler C.J, and Lioy P.J . Ozone and limonene in indoor air: a source of submicron particle exposure. Environ Health Perspect 2000: 108(12): 1139–1145.

    Article  CAS  Google Scholar 

  • Walinder R., Norback D., Wieslander G., Smedje G., and Erwall C . Nasal mucosal swelling in relation to low air exchange rate in schools. Indoor Air 1997: (3): 198–205.

    Google Scholar 

  • Walinder R., Norback D., Wieslander G., Smedje G., Erwall C., and Venge P . Nasal potency and biomarkers in nasal lavage — the significance of air exchange rate and type of ventilation in schools. Int Arch Occup Environ Health 1998: 71(7): 479–486.

    Article  CAS  Google Scholar 

  • Wallace L.A., Nelson W.C., Pellizzari E., Raymer J.H., and Thomas K.W . “Identification of Polar Volatile Organic Compounds in Consumer Products and Common Microenvironments”. Paper presented (#A312) at the 84th Annual Meeting of the Air and Waste Management Association, Vancouver, B.C., Canada, June 16-21, 1991, EPA/600/D-91/074.

  • Wantke F., Demmer C.M., Tappler P., Gotz M., and Jarisch R . Exposure to gaseous formaldehyde induces IgE-mediated sensitization to formaldehyde in school-children. Clin Exp Allergy 1996: 26(3): 276–280.

    Article  CAS  Google Scholar 

  • Weinstein C.S . The physical environment of the school: a review of the research. Educ Res 1979: 49: 576–611.

    Google Scholar 

  • White K.A . In the Golden State, Schools' Space Needs Translate Into Big Business. Education Week, April 22, 1998. http://www.edweek.com/ew/1998/32mods.h17

  • Wilkins C.K, Wolkoff P., Clausen P.A, Hammer M., Nielsen G.D . Terpene/ozone reaction products (TOPS). Dependence of irritation on reaction time and relative humidity. Proceedings of the Ninth International Conference on Indoor Air Quality and Climate, Vol. 2, Monterey, CA, 2002, pp. 608–612

  • Wolkoff P.C., Wilkins C.K., and Nielsen G.D . Formation of strong airway irritants in terpene/ozone mixtures. Indoor Air 2000: 10: 82–91.

    Article  CAS  Google Scholar 

  • Wyatt J . Temporary quarters. Am School Univ 1997: 69(12): 74–76.

    Google Scholar 

  • Zhang L., Fan Z-H., Harrington R., and Zhang J . Measurements of Aldehydes in Personal Air with DNSH PAKS, RIOPA Study: sampling and Analysis Protocols. Environmental and Occupational Health Science Institute (EOHSI), Rutgers University, Piscataway, NJ, 1999.

  • Zhang L., and Zhang J . Comparing Indoor, Outdoor, and Personal Concentrations Measured Using a DNPH-Based Active Sampling Method with Those Measured Using a DNSH-Based Passive Sampling Method. Presented at the Tenth Annual Meeting of the International Society of Exposure Analysis, Monterey, CA, October 25, 2000.

  • Zhang J., He Q.C., and Lioy P.J . Characteristics of aldehydes — concentrations, sources, and exposures for indoor and outdoor residential microenvironments. Environ Sci Technol 1994: 28(1): 146–152.

    Article  CAS  Google Scholar 

  • Zhang J., Zhang L., Fan Z., and Ilacqua V . Development of the personal aldehydes and ketones sampler based upon DNSH derivatization on solid sorbent. Environ Sci Technol 2000: 34(12): 2601–2607.

    Article  CAS  Google Scholar 

Download references

Acknowledgements

We thank our colleagues for internal reviews during the research, including D. Shendell's doctoral committee. Most importantly, we thank the participating school district administrators, school principals, teachers, and custodians. This research was sponsored by a US EPA STAR Graduate Fellowship (D. Shendell, #U91-5394) and a training grant from the UCLA Center for Environmental Risk Reduction, University of California Toxic Substances Research and Teaching Program.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Derek G Shendell.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Shendell, D., Winer, A., Stock, T. et al. Air concentrations of VOCs in portable and traditional classrooms: Results of a pilot study in Los Angeles County. J Expo Sci Environ Epidemiol 14, 44–59 (2004). https://doi.org/10.1038/sj.jea.7500297

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1038/sj.jea.7500297

Keywords

This article is cited by

Search

Quick links