Abstract
During a pilot study of indoor air quality in restaurants, a survey was performed in 34 medium-priced restaurants in six countries in Asia, Europe, and North America using a uniform protocol. The concentration of selected constituents of environmental tobacco smoke (ETS) present in occupied areas was determined during lunch and dinner periods by measuring the levels of four particulate-phase markers and two gas-phase markers. The particulate-phase markers determined were respirable suspended particles, ultraviolet particulate matter, fluorescing particulate matter, and solanesol particulate matter. The gas-phase markers were nicotine and 3-ethenylpyridine (3-EP). Correlation between the markers was investigated to explore an improved monitoring approach. It was concluded that at least one marker in each phase was necessary to describe adequately the ETS load. An assessment was made of the ventilation system in each restaurant, and effective ventilation rates were determined based on CO2 measurements. Smoking activity was also monitored. These data were used to model nicotine and 3-EP concentrations that resulted in a satisfactory prediction of their levels, especially at the higher concentrations. A total number of 1370 questionnaires were returned by the restaurant patrons in five countries. In some countries, dissatisfaction rates above 20% were observed for draft, freshness of air, and noise. The dissatisfaction rates related to tobacco smoke were less than 20%, which is lower than would be predicted based on measured ETS levels. Based on the results of this international pilot study, recommendations are given for future studies of this type.
This is a preview of subscription content, access via your institution
Access options
Subscribe to this journal
Receive 6 print issues and online access
$259.00 per year
only $43.17 per issue
Buy this article
- Purchase on Springer Link
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout
Similar content being viewed by others
References
American Society for Testing and Materials, D 5955-96. Standard test methods for estimating the contribution of environmental tobacco smoke to respirable suspended particles based on UVPM and FPM. In: Annual Book of ASTM Standards. American Society for Testing and Materials, West Conshohocken, PA, 1996.
American Society for Testing and Materials, D 5075-96. Standard test methods for nicotine and 3-ethenylpyridine in indoor air. In: Annual Book of ASTM Standards. American Society for Testing and Materials, West Conshohocken, PA, 1996.
American Society for Testing and Materials, D 5157-97. Standard guide for statistical evaluation of indoor air quality models. In: Annual Book of ASTM Standards. American Society for Testing and Materials, West Conshohocken, PA, 1997.
American Society for Testing and Materials, D 6271-98. Standard test methods for estimating contribution of environmental tobacco smoke to respirable suspended particles based on solanesol. In: Annual Book of ASTM Standards. American Society for Testing and Materials, West Conshohocken, PA, 1998.
ASHRAE Standard 62-1999. Ventilation for Acceptable Indoor Air quality. ASHRAE Inc., Atlanta, 1999.
Baek S.O., Kim Y.S., and Perry R. Indoor air quality in homes, offices and restaurants in Korean urban areas — indoor/outdoor relationships. Atmos Environ 1997: 31(4): 529–544.
Bluyssen P.M., De Oliveira Fernandes E., Fanger P.O., Groes L., Clausen G., Roulet C.A., Bernhard C.A., and Valbjorn O. European audit project to optimize indoor air quality and energy consumption in office buildings — Final report. Contract JOU2-CT92-0022. Commission of the European Communities, 1995.
Bohanon H.R., and Cole K. Limitations of models for characterizing indoor particle concentrations from cigarettes smoking in an office environment, Clima 2000, Brussels, August 30–September 2, 1997.
Bohanon H.R., Piadé J.-J., Schorp M., and Saint-Jalm Y. Survey of indoor air quality, ventilation, and smoking activity in restaurants (Part II), CORESTA Congress, Brighton, England, 11–15 October, 1998, pp. 376–385.
Cain W.S., Leaderer B., Isseroff R., Berglund L.G., Huey R.J., Lipsitt E.D., and Perlman D. Ventilation requirements in buildings I. Control of occupancy odor and tobacco smoke odor. Atmos Environ 1983: 17(6): 1183–1197.
Cain W.S., Tosun T., See L.C., and Leaderer B. Environmental tobacco smoke: sensory reactions of occupants. Atmos Environ 1987: 21 (2): 347–353.
CEN European Committee for Standardization, Report CEN CR 1752. Ventilation for buildings — design criteria for the indoor environment, 1998.
Clausen G.H., Nielsen K.S., Sahin F., and Fanger P.O. Sensory irritation from exposure to environmental tobacco smoke. In: Proceedings of Fourth International Conference on Indoor Air Quality and Climate — Indoor Air ‘87, Berlin, Germany, 1987, Vol. 2, pp. 52–55.
Commission of the European Communities (CEC) Report No. 11. Guidelines for Ventilation Requirements in Buildings EUR 14449 EN. Office for Publications of the European Communities, Luxembourg, 1992.
Conner J.M., Oldaker G.B., and Murphy J.J. Method for assessing the contribution of environmental tobacco smoke to respirable suspended particles in indoor environments. Environ Technol 1990: 11: 189–196.
Crouse W.E., and Carson J.R. Survey of environmental tobacco smoke (ETS) in Washington DC offices and restaurants. 43rd Tobacco Chemists' Research Conference, Richmond, VA, 1989.
Crouse W.E., Ireland M.S., Johnson J.M., Striegel Jr R.M., Williard C.S., DePinto R.M., Oldaker G.B., and McBride R.L. Results from a survey of environmental tobacco smoke (ETS) in restaurants. In: Harper J.P. (Ed.). Transactions of an International Specialty Conference, Combustion Processes and the Quality of the Indoor Environments. Niagara Falls, NY, 1988, pp. 214–222.
Daisey J.M., Mahanama K.R.R., and Hodgson A.T. Toxic volatile organic compounds in simulated environmental tobacco smoke: emission factors for exposure assessment. J Expo Anal Environ Epidemiol 1998: 8: 313–334.
Douce D.S., Clench M.R., and Frost B. Variation in the estimation of the contribution of environmental tobacco smoke (ETS) to respirable (≤5 μm) indoor air particulates obtained by the use of different analytical methods. J Environ Monit 2001: 3: 295–301.
Eatough D.J. Assessing exposure to environmental tobacco smoke, In: Nagda N. L. (Ed.). Modeling of Indoor Air Quality and Exposure, ASTM STP 1205. American Society for Testing Materials, Philadelphia, 1993, pp. 42–63.
Fanger P.O. Introduction of the olf- and the decipol-unit to quantify air pollution perceived by humans indoors and outdoors. Energy Buildings 1988: 12(1): 1–6.
Guerin M.R., Jenkins R.A., and Tomkins B.A. Mainstream and sidestream cigarette smoke, In: Eisenberg M (Ed.). The Chemistry of Environmental Tobacco Smoke, Composition and Measurement. Lewis Publishers, Boca Raton, 1992, pp. 75–85.
Gunnarsen L., and Fanger P.O. Adaptation to indoor air pollution. Environ Int 1991: 18: 43–54.
Heavner D.L., Morgan W.T., and Ogden M.W. Determination of volatile organic compounds and ETS apportionment in 49 homes. Environ Int 1995: 23: 3–21.
Hodgson A.T., Daisey J.M., Mahanama K.R.R., Brinke J.T., and Alevantis L.E. Use of volatile tracers to determine the contribution of environmental tobacco smoke to concentrations of volatile organic compounds in smoking environments. Environ Int 1996: 22: 295–307.
Hyvärinen M.J., Rothberg M., Kähkönen E., Mielo T., and Reijula K. Nicotine and 3-ethenylpyridine concentrations as markers for environmental tobacco smoke in restaurants. Indoor Air 2000: 10: 121–125.
Ishizu Y. General equation for the estimation of indoor pollution. Environ Sci Technol 1980: 14: 1254–1257.
Jenkins R.A., Guerin M.R., and Tomkins B.A. In: Eisenberg M. (Ed.). The Chemistry of Environmental Tobacco Smoke: Composition and Measurement, 2nd edn. Lewis Publishers, Chelsea, MI, 2000.
Kirk P.W.W., Hunter M., Baek S.O., Lester J.N., and Perry R. Environmental tobacco smoke in indoor air. In: Perry, R. and Kirk, P.W.W. (Eds.). Indoor and Ambient Air Quality. Selper, Ltd., London, 1988, pp. 99–112.
Leaderer B.P., Cain W.S., Isseroff R., and Berglund L. Ventilation requirements in buildings II. Particulate matter and carbon monoxide from cigarette smoking. Atmos Environ 1984: 18(1): 99–106.
Löfroth G. Tobacco smoke in shopping malls and restaurants. Indoor Environ 1993: 2: 173–178.
Martin P., Heavner D.L., Nelson P.R., Maiolo K.C., Risner C.H., Simmons P.S., Morgan W.T., and Ogden M.W. Environmental tobacco smoke (ETS): a market cigarette study. Environ Int 1997: 23(1): 75–90.
Maskarinec M.P., Jenkins R.A., Counts R.W., and Dindal A.B. Determination of exposure to environmental tobacco smoke in restaurant and tavern workers in one US city. J Expo Anal Environ Epidemiol 2000: 10: 36–49.
Meger M., Meger-Kossien I., Riedel K., and Scherer G. Biomonitoring of environmental tobacco smoke (ETS)-related exposure to 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone. Biomarkers 2000: 5(1): 33–45.
Moschandreas D.J., and Vuilleumier K.L. ETS levels in hospitality environments satisfying ASHRAE standard 62-1989: “Ventilation for acceptable indoor air quality.” Atmos Environ 1999: 33: 4327–4340.
Muramatsu M., Umemura S., Fukui J., Arai T., and Kira S. Estimation of personal exposure to ambient nicotine in daily environment. Int Arch Occup Environ Health 1987: 59: 545–550.
Nelson P.R., Conrad F.W., Kelly S.P., Maiolo K.C., Richardson J.D., and Ogden M.W. Composition of environmental tobacco smoke (ETS) from international cigarettes and determination of ETS–RSP: particulate marker ratios. Environ Int 1997: 23: 47–52.
Nelson P.R., Conrad F.W., Kelly S.P., Maiolo K.C., Richardson J.D., and Ogden M.W. Composition of environmental tobacco Smoke (ETS) from international cigarettes, part II: nine country follow-up. Environ Int 1998: 24: 251–257.
Nelson P.R., Heavner D.L., Collie B.B., Maiolo K.C., and Ogden M.W. Effect of ventilation and sampling time on environmental tobacco smoke component ratios. Environ Sci Technol 1992: 26(10): 1909–1915.
Ogden M.W., and Maiolo K.C. Collection and determination of solanesol as a tracer of environmental tobacco smoke in indoor air. Environ Sci Technol 1989: 23: 1148–1154.
Ogden M.W., Maiolo K.C., Oldaker G.B., and Conrad Jr F.W. Evaluation of methods for estimating the contribution of ETS to respirable suspended particles. 43rd Tobacco Chemists' Research Conference, Richmond, VA, 1989.
Ogden M.W., Maiolo K.C., Oldaker G.B., and Conrad Jr F.W. Evaluation of methods for estimating the contribution of ETS to respirable suspended particles, Proceedings of the Fifth International Conference on Indoor Air Quality and Climate, Vol. 2. Toronto, Canada, 1990, pp. 415–420.
Ogden M.W., and Richardson J.D. Effect of lighting and storage conditions on the stability of ultraviolet particulate matter, fluorescent particulate matter, and solanesol. Tob Sci 1998: 42: 10–15.
Ott W.R. Mathematical models for predicting indoor air quality from smoking activity. Environ Health Perspect 1999: 107(Suppl. 2): 375–381.
Seppänen O.A., Fisk W.J., and Mendell M.J. CO2 concentrations with health and other responses in commercial and institutional buildings. Indoor Air 1999: 9: 226–252.
Sofuoglu S.C., and Moschandreas D.J. Statistical distributions of indoor air pollutant concentrations in office buildings. In: Raw G. Aizlewood C. and Warren P. (Eds.). Indoor Air’ 99, Eigth International Conference on Indoor Air Quality and Climate, Vol. 5. Edinburgh, Scotland, 1999, pp. 258–263.
Straub H.E., Nelson P.R., and Toft H.R. Evaluation of smoking lounge ventilation designs. ASHRAE Trans 1992: 99(1): 466–475.
Turner W.A., Bearg D.W., and Brennan T. Ventilation. Occup Med 1995: 10: 41–57.
Van Loy M.D., Nazaroff W.W., and Daisey J.M. Nicotine as a marker for environmental tobacco smoke: implications of sorption on indoor surface materials. J Air Waste Manage Assoc 1998: 48: 959–968.
Walker J.C., Nelson P.R., Cain W.S., Utell M.J., Joyce M.B., Morgan W.T., Steichen T.J., Pritchard W.S., and Stancill M.W. Perceptual and psychophysiological responses of nonsmokers to a range of environmental tobacco smoke concentrations. Indoor Air 1997: 7: 173–188.
Woolfenden E.A., and McClenny W.A. (EPA/625/R-96/010b) — Compendium method TO-17. Determination of volatile organic compounds in ambient air using active sampling onto sorbent tubes. In: Compendium of Methods for the Determination of Toxic Organic Compounds in Ambient Air, 2nd edn., U.S. Environmental Protection Agency, Cincinnnati, OH, 1999, pp. 17–28.
Acknowledgements
We gratefully acknowledge the contributions of Takuya Asai (Japan Tobacco, Inc., Yokohama, Japan), Moon Soo Rhee (Korea Ginseng and Tobacco Research Institute, Taejeon, Korea), Derek Mariner (British American Tobacco Co., Southampton, UK), Laurent Poget (Philip Morris Products SA, Neuchâtel, Switzerland), and Donald Leyden, USA. This work was organized and conducted under the auspices of CORESTA (Paris, France).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Bohanon, H., Piadé, JJ., Schorp, M. et al. An international survey of indoor air quality, ventilation, and smoking activity in restaurants: a pilot study. J Expo Sci Environ Epidemiol 13, 378–392 (2003). https://doi.org/10.1038/sj.jea.7500284
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/sj.jea.7500284
Keywords
This article is cited by
-
Quantification of ETS exposure in hospitality workers who have never smoked
Environmental Health (2010)
-
Exposure to environmental tobacco smoke in German restaurants, pubs and discotheques
Journal of Exposure Science & Environmental Epidemiology (2008)