Abstract
Assessing personal exposure to ozone has only been feasible recently with the introduction of passive ozone samplers. These devices are easy to use, but changes in air velocity across their collection surfaces can affect performance. The Harvard active ozone sampler (AS) was developed in response to problems with the passive methods. This active sampler has been tested extensively as a microenvironmental sampler. To test for personal sampling, 40 children attending summer day-camp in Riverside, California wore the active ozone sampler for approximately 2.6 h on July 19 and 21, 1994, when ozone concentrations were about 100 ppb and 140 ppb, respectively. The children spent 94–100% of the sampling period outside, staying within a well-defined area while participating in normal camp activities. Ambient ozone concentrations across this area were monitored by two UV photometric ozone monitors. The active sampler was worn in a small backpack that was also equipped with a passive ozone sampler. Device precision, reported as the percent difference between duplicate pairs of samplers, was ±3.7% and ±4.2% for the active and passive samplers, respectively. The active sampler measured, on average, 94.5±8.2% of the ambient ozone while the passive samplers measured, on average, 124.5±18.8%. The samplers were worn successfully for the entire sampling period by all participating children.
This is a preview of subscription content, access via your institution
Access options
Subscribe to this journal
Receive 6 print issues and online access
$259.00 per year
only $43.17 per issue
Buy this article
- Purchase on Springer Link
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout
Similar content being viewed by others
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
GEYH, A., ROBERTS, P., LURMANN, F. et al. Initial field evaluation of the Harvard active ozone sampler for personal ozone monitoring. J Expo Sci Environ Epidemiol 9, 143–149 (1999). https://doi.org/10.1038/sj.jea.7500001
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/sj.jea.7500001
Keywords
This article is cited by
-
A miniaturized active sampler for the assessment of personal exposure to nitrogen dioxide
Analytical and Bioanalytical Chemistry (2005)
-
Understanding variability in time spent in selected locations for 7–12-year old children
Journal of Exposure Science & Environmental Epidemiology (2004)