Letter | Published:

A Method of Calibrating Two-Sphere Non-directional Radiometers

Nature volume 192, page 960 (09 December 1961) | Download Citation

Subjects

Abstract

WHEN two heated spheres, one black and one bright, but otherwise identical, are kept at the same temperature, they lose an equal amount of heat by conduction and convection1. Any difference in heat input is due to the difference in radiational exchange. Neither air temperature nor air velocity enters the calculations for determining the mean radiant temperature of the surroundings. The quantities needed are: the heat input of the two spheres; the temperatures of the two spheres (which should be equal); the surface area; the emissivities of the bright and the black sphere. Nickel1 or gold2 is used for plating the bright sphere.

Access optionsAccess options

Rent or Buy article

Get time limited or full article access on ReadCube.

from$8.99

All prices are NET prices.

References

  1. 1.

    , Schweiz. Bl. Heizung und Lueftung, 1 (1938).

  2. 2.

    , and , Research Report GR 2462-R2 (Minneapolis–Honeywell Regulator Co., Sept. 1953).

  3. 3.

    , and , J. Hyg. (Camb.), 34, 460 (1934).