Skip to main content

Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

  • Letter
  • Published:

Large-Scale Polymer Column Fractionation

Abstract

THE gradient elution method for polymer fractionation was introduced by Williams1–3. To fractionate larger amounts of polymer, a scaled-up apparatus was necessary. Previous experience in column design in this laboratory advised against an increase in the dimensions of a single column to avoid difficulties in temperature control and channelling. Consequently, an apparatus was built with six parallel columns, each 1 m. in length and 2.5 cm. in inside diameter. A sketch of the multicolumn unit is shown in Fig. 1. The upper ends of the aluminium columns are welded to the bottom of a common solvent-mixing container. The metal container is 7 litres in capacity and is fitted with a heater, regulator, stirrer, and sight glass. The solvent mixture is heated to the proper temperature for the desired column temperature gradient. The lower ends of the columns are connected to a common outlet and immersed in a water thermostat. The temperature gradient along the insulated columns is found to be nearly linear, as measured by four evenly spaced thermocouples. The apparatus is charged and operated similarly to single columns previously described1–3. Two ganged ‘Minipumps’ (Milton Roy Company, Philadelphia, Pennsylvania), each with an adjustable 12–120 ml./hr. pumping capacity, regulate the rate of withdrawal of polymer solution from the common outlet. The pumps also replenish the solvent at the head of the column at the same rate, thus establishing the solvent gradient and degree of fractionation. The evaporation of the solvent for recovery of fractions is done automatically, in situ, using a rotary vacuum evaporator, fitted with a nitrogen inlet, vacuum line, and water-bath. A low evaporation temperature coupled with the nitrogen ensures polymer stability.

This is a preview of subscription content, access via your institution

Access options

Rent or buy this article

Prices vary by article type

from$1.95

to$39.95

Prices may be subject to local taxes which are calculated during checkout

Similar content being viewed by others

References

  1. Williams, R. J. P., Analyst, 77, 905 (1952).

    Article  ADS  CAS  Google Scholar 

  2. Bannister, D. W., Phillips, C. S. G., and Williams, R. J. P., Anal. Chem., 26, 1451 (1954).

    Article  CAS  Google Scholar 

  3. Baker, C. A., and Williams, R. J. P., J. Chem. Soc., 2352 (1956).

  4. Fox, T. G., and Flory, P. J., J. Phys. and Coll. Chem., 55, 221 (1951).

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

CANTOW, M., PORTER, R. & JOHNSON, J. Large-Scale Polymer Column Fractionation. Nature 192, 752–753 (1961). https://doi.org/10.1038/192752a0

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1038/192752a0

This article is cited by

Comments

By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.

Search

Quick links

Nature Briefing

Sign up for the Nature Briefing newsletter — what matters in science, free to your inbox daily.

Get the most important science stories of the day, free in your inbox. Sign up for Nature Briefing