Abstract
The purpose of this study was to evaluate the efficacy and safety in placement of Hickman catheters via the supraclavicular route without fluoroscopic guidance. We studied 81 consecutive percutaneous placements of dual lumen Hickman catheters via the supraclavicular route without the use of fluoroscopic guidance. Success rates, technical problems, complications, infections and reasons for explantation were recorded prospectively. Seventy-nine punctures were successful (97.5%). One pneumothorax (1.2%) and three accidental arterial punctures (3.7%) occurred. Difficulties in introducing the catheter through the peel away sheath or misplacement were not observed. The catheters remained in place for a total of 7657 days (mean 94.5, range 3–392 days). Sixteen blood cultures were positive (2.1/1000 catheter days). Five catheters (6.1%) were lost because of mechanical complications. Forty-two lines (52%) were removed electively, 23 (28.4%) because of suspected infection, and two (2.5%) because of tunnel infection. Nine patients died with a functioning catheter. We conclude that the supraclavicular approach to the subclavian vein is safe and efficient for introduction of Hickman catheters. Using this access, routine fluoroscopic or sonographic guidance is not required for proper placement. Implantation of the lines in an intensive care unit did not lead to higher infection rates than those reported in the literature.
This is a preview of subscription content, access via your institution
Access options
Subscribe to this journal
Receive 12 print issues and online access
$259.00 per year
only $21.58 per issue
Buy this article
- Purchase on Springer Link
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout
Similar content being viewed by others
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Apsner, R., Schulenburg, A., Sunder-Plassmann, G. et al. Routine fluoroscopic guidance is not required for placement of Hickman catheters via the supraclavicular route. Bone Marrow Transplant 21, 1149–1152 (1998). https://doi.org/10.1038/sj.bmt.1701250
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/sj.bmt.1701250
Keywords
This article is cited by
-
Procedural safety of a fully implantable intravenous prostanoid pump for pulmonary hypertension
Clinical Research in Cardiology (2017)
-
Central venous catheter pinch-off and fracture: recognition, prevention and management
Bone Marrow Transplantation (2003)