Abstract
Objective: To assess intra- and inter-site soft tissue variability by dual energy X-ray absorptiometry (DXA). Design: Cross-sectional trial. Setting: Three medical research institutions. Subjects: Five humans (in vivo) and four phantoms (in vitro), configured from two whole body phantoms with artificial skeletons and thickness overlays. Interventions: Duplicate total-body DXA scans were performed on all subjects at each institution within a 15 d period. Results: All intra-site coefficients of variation (CV) were <0.5% for total tissue mass, but in vitro and in vivo Cvs were 7.2% and 2.3% for fat mass (FM) and 2.5% and 0.9% for lean mass (LM), respectively. Several total-body and regional FM and LM measurements were significantly different between sites (P < 0.05), with percent differences between sites ranging from 2.6–13.3% for FM and from 1.6–13.6% for LM. Site 2 was consistently lower for FM and Site 3 was consistently lower for LM. Conclusions: These results stress the need for both rigorous and standardized cross-calibration procedures for soft tissue measurement by DXA. Sponsorship: This work has been supported in part by NIH Training Grant #T32AG00209, grant P01-DK42618 from the National Institutes of Health, federal funds from the US Department of Agriculture, and Agricultural Research Services contract 53-3K06-5-10. Dr Nelson is currently a Brookdale National Fellow.
This is a preview of subscription content, access via your institution
Access options
Subscribe to this journal
Receive 12 print issues and online access
$259.00 per year
only $21.58 per issue
Buy this article
- Purchase on Springer Link
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout
Similar content being viewed by others
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Economos, C., Nelson, M., Fiatarone, M. et al. A multi-center comparison of dual energy X-ray absorptiometers: In vivo and in vitro soft tissue measurement. Eur J Clin Nutr 51, 312–317 (1997). https://doi.org/10.1038/sj.ejcn.1600400
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1038/sj.ejcn.1600400
Keywords
This article is cited by
-
In vivo precision of the GE Lunar iDXA densitometer for the measurement of total body composition and fat distribution in adults
European Journal of Clinical Nutrition (2011)
-
Regional Body Composition: Cross‐calibration of DXA Scanners—QDR4500W and Discovery Wi
Obesity (2010)
-
Estimating body fat in NCAA Division I female athletes: a five-compartment model validation of laboratory methods
European Journal of Applied Physiology (2009)
-
Validity of air-displacement plethysmography in the assessment of body composition changes in a 16-month weight loss program
Nutrition & Metabolism (2006)
-
Body fat measurement in adolescent athletes: multicompartment molecular model comparison
European Journal of Clinical Nutrition (2006)