Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

  • Original Communication
  • Published:

A multi-center comparison of dual energy X-ray absorptiometers: In vivo and in vitro soft tissue measurement

Abstract

Objective: To assess intra- and inter-site soft tissue variability by dual energy X-ray absorptiometry (DXA). Design: Cross-sectional trial. Setting: Three medical research institutions. Subjects: Five humans (in vivo) and four phantoms (in vitro), configured from two whole body phantoms with artificial skeletons and thickness overlays. Interventions: Duplicate total-body DXA scans were performed on all subjects at each institution within a 15 d period. Results: All intra-site coefficients of variation (CV) were <0.5% for total tissue mass, but in vitro and in vivo Cvs were 7.2% and 2.3% for fat mass (FM) and 2.5% and 0.9% for lean mass (LM), respectively. Several total-body and regional FM and LM measurements were significantly different between sites (P < 0.05), with percent differences between sites ranging from 2.6–13.3% for FM and from 1.6–13.6% for LM. Site 2 was consistently lower for FM and Site 3 was consistently lower for LM. Conclusions: These results stress the need for both rigorous and standardized cross-calibration procedures for soft tissue measurement by DXA. Sponsorship: This work has been supported in part by NIH Training Grant #T32AG00209, grant P01-DK42618 from the National Institutes of Health, federal funds from the US Department of Agriculture, and Agricultural Research Services contract 53-3K06-5-10. Dr Nelson is currently a Brookdale National Fellow.

This is a preview of subscription content, access via your institution

Access options

Buy this article

Prices may be subject to local taxes which are calculated during checkout

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Economos, C., Nelson, M., Fiatarone, M. et al. A multi-center comparison of dual energy X-ray absorptiometers: In vivo and in vitro soft tissue measurement. Eur J Clin Nutr 51, 312–317 (1997). https://doi.org/10.1038/sj.ejcn.1600400

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1038/sj.ejcn.1600400

Keywords

This article is cited by

Search

Quick links