Diamagnetism of Liquid Mixtures

Article metrics

Abstract

CRITICISMS of our magnetic susceptibility measurements of mixtures of acetone and chloroform1 have been made by Ranganadham,2 van Aubel,3 Buchner,4 and Ramachandra Rao and Sivaramakrishnan.5 We have therefore repeated the susceptibility measurements of this series of liquids by the Gouy method, using a magnet with a field strength of about 3300 gauss. The apparatus not being available in this laboratory, Dr. S. Sugden, to whom we wish to express our thanks, kindly permitted us to make use of his apparatus at Birkbeck College. With this particular apparatus values of the susceptibility can be obtained which are accurate to within ±0.02 × 10-6.

Access options

Rent or Buy article

Get time limited or full article access on ReadCube.

from$8.99

All prices are NET prices.

References

  1. 1

    Trew and Spencer, Proc. Roy. Soc., 131, p. 209; 1931.

  2. 2

    Ranganadham, NATURE, 127, 975, June 27, 1931.

  3. 3

    van Aubel, NATURE, 128, 455, Sept. 12, 1931.

  4. 4

    Buchner, NATURE, 128, 301, Aug. 22, 1931.

  5. 5

    Ramachandra Rao and Sivaramakrishnan, NATURE, 128, 872, Nov. 21, 1931.

  6. 6

    Farquharson, NATURE, 129, 25, Jan. 2, 1932.

Download references

Author information

Rights and permissions

Reprints and Permissions

About this article

Cite this article

SPENCER, J., TREW, C. Diamagnetism of Liquid Mixtures. Nature 129, 95–96 (1932) doi:10.1038/129095b0

Download citation

Comments

By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.