Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

  • Original Article
  • Published:

Practice audits: reliability of sphygmomanometers and blood pressure recording bias

Abstract

It is well established that numerous errors, biases and omissions in recording blood pressure exist. This study had two objectives. Firstly, to measure the accuracy of sphygmomanometers used in general practice and secondly to assess digit bias in blood pressure recording. This study was carried out in the then Northfield PCG, which comprised 18 practices and 67 GPs. A total of 131 mercury and aneroid sphygmomanometers were tested for accuracy by a trained technician in accordance with the methods specified in BS 2743 (1990). Accuracy was defined as an error of greater than 10 mm Hg. The second part of the methodology involved undertaking an audit of the proportion of registered patients aged 35–80 years who had their blood pressure measured within the last 5 years by members of the Primary Health Care Team. The results were that of the mercury and aneroid sphygmomanometers tested, 17% were inaccurate. Of these, 4% recorded an error greater than 10 mm Hg. One percent of mercury and 10% of aneroid sphygmomanometers recorded an error greater than 10 mm Hg respectively. Sixteen (12%) sphygmomanometers were so deteriorated (air leaks, dirt in mercury) that the researcher suggested their immediate withdrawal from service. The results of the blood pressure recording audit suggested digit bias of both systolic and diastolic recordings to the nearest 10 mm Hg. This study suggests that sphygmomanometers used in general practice are very likely to be inaccurate and some may well be so deteriorated that they should be withdrawn from service. The results of the blood pressure audit showed digit bias in systolic and diastolic readings to the nearest 10 mm Hg. The implications for clinical care—both over diagnosis and under diagnosis—although not assessed are likely to be appreciable. PCG Clinical Governance teams in conjunction with Practice Clinical Leads must address these basic issues.

This is a preview of subscription content, access via your institution

Access options

Buy this article

Prices may be subject to local taxes which are calculated during checkout

Figure 1
Figure 2

Similar content being viewed by others

References

  1. Ramsey LE et al. Guidelines for management of hypertension: report of the third working party of the British Hypertension Society J Hum Hypertens 1999; 13: 569–592

    Article  Google Scholar 

  2. Markandu ND, Whitcher F, Arnold A, Carney C . The mercury sphygmomanometer should be abandoned before it is prescribed J Hum Hypertens 2000; 14: 31–36

    Article  CAS  Google Scholar 

  3. National Institute of Health, National Heart, Lung, and Blood Institute. The Sixth Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure Arch Intern Med 1997; 153: 154–183

  4. Zanchetti A et al. The 1993 Guidelines for the management of mild hypertension: memorandum from WHO/ISH meeting Hypertension 1993; 22: 392–403

    Article  Google Scholar 

  5. Perloff D et al. Human blood pressure determination by sphygmomanometry Circulation 1993; 88: 2460–2470

    Article  CAS  Google Scholar 

  6. Frohlich E et al. Recommendations for human blood pressure determination by sphygmomanometers Circulation 1988; 77: 501A–514A

    Google Scholar 

  7. Derry J . Sample size for audit Managing Audit in General Practice, Summer 1993: 17–20

    Google Scholar 

  8. Bailey RH, Knaus VL, Bauer JH . Aneroid sphygmomanometers Arch Intern Med 1991; 15: 1409–1412

    Article  Google Scholar 

  9. Burke MJ et al. Sphygmomanometers in hospital and family practice: problems and recommendations Br Med J 1982; 285: 469–471

    Article  CAS  Google Scholar 

  10. Mion D Jr, Pierin AMG . How accurate are sphygmomanometers? J Hum Hypertens 1998; 12: 245–248

    Article  CAS  Google Scholar 

  11. http://www.white-medical.co.uk

Download references

Acknowledgements

We are grateful to all the GPs and staff in Northfield PCG for their co-operation and support in this study. We would also like to thank Mr David Stenson, Chief Officer, and Ann Rouine, Clinical Governance Nurse Board member, for their helpful comments on the manuscript.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to S Ali.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ali, S., Rouse, A. Practice audits: reliability of sphygmomanometers and blood pressure recording bias. J Hum Hypertens 16, 359–361 (2002). https://doi.org/10.1038/sj.jhh.1001384

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1038/sj.jhh.1001384

Keywords

This article is cited by

Search

Quick links