Abstract
Aim: To test the effect of positioning the arm on the arm-rest of a common chair, below the officially recommended right atrial level, on the blood pressure (BP) readings in a group of out-patients.
Patients and methods: A group of 69 patients (58 hypertensives; 39 males; mean ± s.d. age 54.1 ± 16.0 years) participated in the present study. BP and heart rate values obtained in each of the following two positions were compared: (1) sitting with the arms supported on the arm-rests of the chair and (2) sitting with the arms supported at the level of the mid-sternum (the approximation of the right atrial level). BP was measured simultaneously at both arms, with a mercury sphygmomanometer at the right arm and with an automatic oscillometric device at the left arm.
Results: Both the systolic and diastolic BPs were significantly higher (P < 0.0001) when the arm was placed on the arm-rest of the chair than at the right atrial level. the same differences ± s.d. in bp between the two positions were obtained with both measurement techniques: 9.7 ± 9.4 mm hg (systolic) and 10.8 ± 5.8 mm hg (diastolic) with the mercury sphygmomanometer and respectively 7.3 ± 8.9 mm hg and 8.3 ± 6.0 mm hg with the oscillometric device. no difference in the heart rate was found between the two positions.
Conclusions: Placing the patient’s arms on the arm-rest of the chair instead of at the reference right atrial level, BP measurement will result in spuriously elevated BP values. This may be of great importance for the diagnosis and the subsequent treatment decisions for patients with hypertension.
This is a preview of subscription content, access via your institution
Relevant articles
Open Access articles citing this article.
-
Challenges in standardization of blood pressure measurement at the population level
BMC Medical Research Methodology Open Access 10 April 2015
Access options
Subscribe to this journal
Receive 12 digital issues and online access to articles
$119.00 per year
only $9.92 per issue
Rent or buy this article
Prices vary by article type
from$1.95
to$39.95
Prices may be subject to local taxes which are calculated during checkout
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Netea, R., Lenders, J., Smits, P. et al. Arm position is important for blood pressure measurement. J Hum Hypertens 13, 105–109 (1999). https://doi.org/10.1038/sj.jhh.1000720
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/sj.jhh.1000720
Keywords
This article is cited by
-
Do physicians measure patients’ blood pressure, and are those measurements reliable?
Journal of Human Hypertension (2018)
-
Challenges in standardization of blood pressure measurement at the population level
BMC Medical Research Methodology (2015)
-
Reduction in finger blood flow induced by hand-transmitted vibration: effect of hand elevation
International Archives of Occupational and Environmental Health (2015)
-
The impact of pulse pressure on the accuracy of wrist blood pressure measurement
Journal of Human Hypertension (2009)
-
Arm position and blood pressure: a risk factor for hypertension?
Journal of Human Hypertension (2003)