Introduction

Heavy metal detection has received much attention in scientific research due to their serious threat to the environment and health1,2,3,4. Of particular interest there has been the detection of copper (II) ion, a dangerous pollutant that causes adverse afflictions in people upon excess intake, including liver or kidney damage, gastrointestinal disturbance5, Parkinson’s disease, Wilson’s disease and Alzheimer’s disease3,4. Considering its toxicity, the Chinese Ministry of Health (CMH), U.S. Environment Protection Agency (EPA) and World Health Organization (WHO) regulate maximum permissible levels of copper (II) of less than 15 μM6, 20 μM7 and 31 μM in water8, respectively. Thus, instrumental analytical techniques for Cu2+ detection have been developed, such as inductively coupled plasma mass spectrometry (ICP-MS)9, atomic absorption spectrometry (AAS)10, inductively coupled plasma atomic emission spectrometry (ICP-OES) and fluorescence spectrometry11,12. However, these widely used instrumental techniques are rather complicated, requiring sophisticated apparatus and professional personnel, which are obstructive to further application. To keep pace with expectations in future on-site rapid testing, the development of new sensing techniques for Cu2+ is a hot issue in analytical chemistry in recent years.

Among numerous new sensors, DNAzyme-based biosensors are of particular interest13,14. DNAzyme, a type of functional nucleic acid, is able to catalyze a series of reactions. Recently, two types of DNAzyme have been a hot topic of research. One type of DNAzyme is G-quadruplex-based DNAzyme, which possesses mimic-horse radish peroxidase (HRP) activity to catalyze specific substrate for chromogenic reaction15,16,17,18,19. The other type is metal ion-dependent DNAzyme, Which could depend on specific metal ions as cofactors, such as Ag+ ions20, Na+ ions21,22, Cu2+ ions23,24,25, Pb2+ ions26,27, Mg2+ ions28, Zn2+ ions29,30, Ca2+ ions31,32, Cd2+ ions33, UO22+ ions, Hg2+ ions34,35, and lanthanide ions36,37,38. Most metal ions activate specific DNAzyme via cleavage. According to the nucleotide type of cleavage site (ribonucleotide and deoxyribonucleotide), metal ion-dependent DNAzyme classified as RNA-cleaving DNAzyme and DNA-cleaving DNAzyme. Cu2+-specific DNAzyme, which belongs to DNA-cleaving DNAzyme with the characteristics of easy synthesis, lower cost and better stability, leads to site-specific cleavage at the guanine position of the substrate in catalytic/substrate multiple strands, which makes it an ideal element for Cu2+ ion detection due to inherent advantages of outstanding stability under harsh conditions and high selectivity comparable to antibodies14,39,40. Over the past decade, different DNAzyme-based biosensors for Cu2+ using various signal transduction methods have been developed, including fluorescence41,42, colorimetry39,42,43,44 and lateral flow nucleic acid techniques45. Such DNAzyme-based sensing strategies require simpler apparatus and less professional personnel than traditional techniques.

Interestingly, hybridization chain reactions (HCR), which generate linear DNA nanostructures arisen by self-assembly of short DNA fragments through a cross-opening process, have recently become one of the most active research areas in molecular biology and DNA diagnostics relying on several unique advantages46,47. Firstly, signal amplification via Watson-Crick base pairing is easier to achieve, which can lead to ultrasensitive detections. Secondly, HCR exhibit the potential of signal reporting via special labels, which pave the way toward multi-target sensing platforms. However, HCR rely on reaction time and are temperature-dependent, so a relatively long time or appropriate temperature likely triggers false positives that interfere with the results. In our research, the HCR was prepared in advance via ingenious hairpin design, effectively eliminating undesirable initiation. Herein, we achieved the proof-of-concept to integrate Cu2+-dependent DNAzyme with HCR-based HRP concatemers for rapid detection of Cu2+ semi-quantitatively observed by the naked eye and quantitatively monitored by a portable spectrophotometer in 5 min, exhibiting immense potential for on-site detection.

Experiment Section

Reagents and Apparatus

All oligonucleotides were HPLC-purified and synthesized at Invitrogen (Life Technologies, Beijing, China). The substrate strand and catalytic strand for copper (II)–dependent DNAzyme were designed according to the literature42. The sequences of the oligonucleotides are as follows:

Substrate strand for Cu2+-dependent DNAzyme (S1):

5′-GGGGGGGGGGGGGGGGGGGGGGTTTTTTTAGCTTCTTTCTAATACGGCTTACCTTTTTTTTTT-Biotin-3′

Catalytic strand for Cu2+-dependent DNAzyme (S2):

5′-GGTAAGCCTGGGCCTCTTTCTTTTTAAGAAAGAAC-3′

Linker-labeled initiator (S3):

5′-CTGAGCTTCGGATTCTGTTTGGCCCCCCCCCCCCCCCCCCCCCC-3′

Hairpin DNA (H1):

5′-Biotin-GGCCAAACAGAATCCGAAGCTCAGACCCTGCTGAGCTTCGGATTCTGT-3′

Hairpin DNA (H2):

5′-Biotin-CTGAGCTTCGGATTCTGTTTGGCCACAGAATCCGAAGCTCAGCAGGGT-3′

The ingenious design of hairpins should meet the following requirements: Hairpins (H1 and H2) should possess the same number of bases and the same number of sticky ends. Noticeably, the sticky ends of H1 locates at the 5′-end while that of H2 locates at the 3′-end. To better promote HCR, nearly half fragment of H2 at the 5′-end was truncated as the initiator strand. High binding polystyrene 96-welll microplate was purchased from Costar (NY, USA). In addition, 4-(2-hydroxyethyl) piperazine-1-ethanesulfonic acid (HEPES), ascorbate, streptavidin (SA), bovine serum albumin (BSA), and streptavidin-horseradish peroxidase (SA-HRP) were obtained from Sigma-Aldrich Chemical Co. (St. Louis, MO, USA). Tetramethylbenzidine (TMB) coloring solution was purchased from Biyuntian Co. Ltd (Beijing, China). Ultrapure water was used throughout the experiment and was obtained from a Milli-Q water purifying system (resistivity ≥18.2 MΩ cm−1, Milli-Q, Millipore). Other chemicals were of analytical grade and were used without further purification.

Gel electrophoresis was conducted on a Molecular Imager Gel Doc XR (Bio-Rad, Canada). Visual measurements were carried out with a portable spectrophotometer (NS810, Shenzhen 3nh Technology Co., Ltd). The transmission electron micrograph (TEM) was performed on a JEOL JEM-1400 Transmission electron micrograph (Germany).

Immobilization of copper (II)–dependent DNAzyme

To immobilize Cu2+-dependent DNAzyme, 2 μg/mL SA (100 μL) in carbonate buffer solution (CBS, 15 mM Na2CO3, 35 mM NaHCO3, pH 9.6) was added to wells and incubated at 37 °C for 2 h. After washing three times with 250 μL wash buffer (0.15 M NaCl, 10 mM K2HPO4, 1 mM NaH2PO4, 0.05% Tween 20, pH 7.4), the wells were blocked with 200 μL of 1% BSA per well at 37 °C for 2 h. Then, 100 μL biotinylated S1 (120 nM) dissolved in phosphate buffer solution (PBS, 0.15 M NaCl, 10 mM K2HPO4, 1 mM NaH2PO4, pH 7.4) was added to each well of 96-well plates and incubated at 37 °C for 1 h. Next, the wells were washed three times with wash buffer, incubated with S2 (150 nM) dissolved in 50 mM HEPES buffer (pH 7.0) containing 1.5 M NaCl at 37 °C for 100 min and washed three times again.

Preparation of HCR-based HRP concatemers

Biotinylated hairpins (H1 and H2) were heated at 95 °C for 5 min and then cooled to 4 °C slowly for 1.5 h before use. The hybridization chain reaction (HCR) proceeded at 37 °C for 1 h, composed of 200 nM S3, 1 μM H1 and 1 μM H2 in Tris-HCl Buffer (10 mM Tris, 500 mM NaCl, 1 mM MgCl2, pH 7.4). Afterwards, SA-HRP (500 ng/mL) was added to the HCR system and incubated at 37 °C for 1 h to form the HCR-HRP complex. HCR products were detected by 2% EB-stained agarose gel electrophoresis. HCR-based HRP concatemers was inspected by the transmission electron micrograph48.

Assembly of the detection unit and copper (II) assay

Immobilized Cu2+-dependent DNAzyme was concatenated with HCR-based HRP complex (100 μL) in each well at 37 °C for 2 h. After washing three times, the detection unit of Cu2+ was achieved. Then a fixed concentration of Cu2+ (CuSO4, 100 μL) dispersed in the reaction buffer (1.5 M NaCl, 50 mM HEPES and 50 μM ascorbate) was incubated with the Cu2+-detection unit in each well at 37 °C for 5 min. The same volume of reaction buffer was used as the negative control. After washing three times, 100 μL TMB coloring solution was added to each well. Then, the samples were incubated at room temperature away from light for 5 min, and 50 μL H2SO4 (2 M) was added to terminate the chromogenic reaction. The absorbance values at 450 nm (OD450) were monitored by a portable spectrophotometer.

HPLC-DAD analysis

Conditions for DNA analysis followed the description by Wilde et al. with some modifications49. HPLC analyses were performed on an Agilent 1100 HPLC system together with a diode array detector (DAD). A TSKgel DNA-NPR (4.6 mm i.d. × 7.5 cm, Tosoh, Japan) was employed. DNA samples were separated by buffer A (20 mM Tris, pH 9.0) and buffer B (1 M NaCl in 20 mM Tris, pH 9.0) according to the following gradient: 25–45% B in 0–0.13 min, 45–50% B in 0.13–4 min, 50–64% B in 4–25 min, 25% B in 25.1–35 min. The flow rate was 0.4 mL/min with an injection volume of 10 μL. DNA elution was monitored by UV absorbance at 260 nm. All chromatography was performed at 35 °C.

Detection of real water samples

Non-contaminated commercial bottled purified water was purchased from the local supermarket. Lake water was collected from Beijing Olympic Green Park, Beijing, China. Domestic sewage was obtained from the Beijing north river sewage treatment factory, Chaoyang District, Beijing, China. Firstly, the water samples were gently mixed with Cu2+ standard solution, generating two final Cu2+ concentrations (0.5 μM and 2.5 μM). Then, a 90-μL water sample was mixed with 10 μL 10× reaction buffer (15 M NaCl, 500 mM HEPES and 500 μM ascorbate), and the obtained 100-μL solution was treated using the same protocol as noted above for the Cu2+ detection. The ICP-MS analysis for Cu2+ in real water samples was based on Szpunar’s study6.

Result and Discussion

Design principle of turn-off sensor

The rapid and visual DNA concatenation sensor for Cu2+ detection is schematically illustrated in Fig. 1. Beforehand, SA was immobilized onto the high binding polystyrene well via hydrophobic effect. Then, S1 was captured via biotin-streptavidin combination, which was flanked with spacer sequences of poly-thymine (poly-T) oligonucleotides at the 3′ end and with linker sequence of poly-guanine (poly-G) oligonucleotides at the 5′ end. Via Watson-Crick base pairing at the 3′ terminus and the formation of the DNA triplex at the 5′ terminus, S2 coupling with S1 formed the Cu2+-dependent DNAzyme. So Cu2+-dependent DNAzyme was coated onto the well via biotin-streptavidin linkage to identify the target.

Figure 1
figure 1

Schematic of the design of the turn-off sensor for the detection of copper (II) ion (Cu2+) based on Cu2+-dependent DNAzyme coupled with HCR-based HRP concatemers.

Simultaneously, SA-HRP and the nicked DNA double-helix formed a complex. In the presence of linker-labeled initiator, biotinylated hairpin 1 (H1) first underwent an unbiased strand-displacement reaction to open the hairpin from the 5′ sticky end. The newly exposed sticky nucleates of H1 opened biotinylated hairpin 2 (H2) and underwent a strand-displacement reaction, exposing another sticky end. Similarly, a chain reaction of hybridization events was propagated to form the biotinylated nicked DNA double-helix, acting as the signal amplifier. In the presence of SA-HRP, which often served as the signal output element, the linker-labeled HCR-based HRP complex formed via biotin-streptavidin linkage. Given that HCR-based HRP complex not only amplified detection signal but also catalyzed hydrogen peroxide (H2O2) via TMB, generating obvious yellow color visible to the naked eye and optical intensity at 450 nm (OD450) after sulfuric acid termination, the HCR-based HRP complex acted as a signal amplification element as well as a signal report element.

Finally, Cu2+-dependent DNAzyme concatenated with the HCR-based HRP complex was achieved via Watson-Crick base pairing. Upon target Cu2+ introduction, S1 of the Cu2+-dependent DNAzyme concatenated with the HCR-based HRP complex was irreversibly cleaved. We hypothesized that the cleaved pieces were released and totally washed, leading to the dramatic reduction in OD450 values and absence of yellow color.

Optimization of the immobilized Cu2+-dependent DNAzyme

Given that the Cu2+-dependent DNAzyme was immobilized onto the surface via biotin-streptavidin linkage, the concentrations of SA, biotinylated substrate strand (S1) and Cu2+ catalytic strand (S2) were optimized. As illustrated in Fig. 2, the following equation was employed: absorbance ratio (%) = A0/A × 100 at 450 nm7, where A0 and A represent the optical intensity after and before Cu2+ sample addition, respectively. Smaller the ratio, more remarkable the signal variation was, indicating the more appropriate detection conditions. In Fig. 2A, with the SA concentration ranging from 0.5 to 8 μg/mL, the absorbance ratio (%) exhibited a wave trough and a valley point at 2 μg/mL of SA, presumably due to stereo-hindrance effects. Small amounts of SA could not capture sufficient amounts of the biotinylated substrate strand, whereas excess SA would lead to steric hindrance, reducing binding with the strand50. In Fig. 2B, the ratio gradually declined until reaching a plateau at 120 nM from low dose to high dose, mainly because the combination of streptavidin with biotin conformed to the molar ratio of one to four (SA: 2 μg/mL ≈ 30 nM)51,52. In Fig. 2C, the ratio was reduced from 100 to 150 nM and subsequently maintained a relatively low value, indicating that slightly excessive S2 compared with S1 was ideal for saving experimental materials. In general, 2 μg/mL of SA, 120 nM of S1 and 150 nM of S2 were optimal.

Figure 2: Optimization of immobilized Cu2+-dependent DNAzyme.
figure 2

(A) Absorbance ratio (%) of the turn-off sensor with different concentrations of SA (μg/mL). The concentrations from the left are 0.5, 1, 2, 3, and 8 μg/mL. (B) Absorbance ratio (%) of the turn-off sensor with different concentrations of S1 (nM). The concentrations from the left are 25, 50, 100, 120, 200, and 400 nM. (C) Absorbance ratio (%) of the turn-off sensor with different concentrations of S2 (nM). The concentrations from the left are 100, 120, 150, 240, and 360 nM. Error bars represent standard deviation (N = 3).

Characterization of the Chromatographic Behavior of the Cu2+-dependent DNAzyme on a DNA-NPR Column

Anion exchange chromatography is a widely used technique for separating negatively-charged DNA molecules. The TSK gel DNA-NPR column is a polymer-based anion exchange column for improved DNA resolution over a wide molecular weight range. The capability of the TSK gel DNA-NPR column to separate both high and low molecular weight DNA fragments has been demonstrated by Wilde et al.49. Figure 3A,B and C present typical elution profiles of the negative control of the reaction buffer, before and after the Cu2+ cleavage of the Cu2+-dependent DNAzyme, respectively. In Fig. 3A, the negative control showed a high response value at the retention time of 1.187 min with the corresponding peak area of 917. Compared with the negative control, Fig. 3B revealed a relatively high response value at the retention time of 19.835 min with the corresponding peak area of 3073, indicating that the chromatographic peak resulted from the non-dissected Cu2+-dependent DNAzyme. In Fig. 3C, there was no response at 19.835 min, whereas a new high chromatographic peak appeared at the retention time of 9.239 min compared with Fig. 3B, suggesting the split Cu2+-dependent DNAzyme. Based on these scientific data, we concluded that the Cu2+-dependent DNAzyme was cut into small pieces after Cu2+ sample addition.

Figure 3: Characterization of Chromatographic Behavior of Cu2+-dependent DNAzyme on a DNA-NPR Column.
figure 3

(A) Characterization of chromatographic behavior for the negative control of the reaction buffer on a DNA-NPR Column. (B) Characterization of chromatographic behavior for the non-dissected Cu2+-dependent DNAzyme on a DNA-NPR Column. (C) Characterization of chromatographic behavior for Cu2+ (1 mM) cleavage of the Cu2+-dependent DNAzyme on a DNA-NPR Column.

Optimization of HCR-based HRP concatemers

As the signal amplifier and signal report element, HCR-based HRP concatemers were optimized, including HCR and the dosage of SA-HRP. To the best of our knowledge, the signal amplification effect of HCR depends on the length of the hybridization chain. Longer the HCR product, the better the effect of signal amplification is. Inspiringly, the longitude of the hybridization chain was hinged on the ratio between the dose of the initiator and two closed hairpins53. As proof-of-principle (Fig. 4A), the HCR between the initiator (S3) and H1 and H2 was examined by agarose gel electrophoresis. In the absence of S3, a bright band of H1 (lane 2) and H2 (lane 3) could be observed, and the HCR between H1 and H2 was inhibited (lane 4). However, emission bands of high-molecular-weight structures could be observed in lanes 5–10, indicating that higher the ratio of the initiator to hairpins, lower the molecular weight of the HCR product was. A 1:10 ratio of initiator to hairpins triggered the longest hybridization chain, reaching a length of 2 kb. Ratios of 1.5:10 and 2:10 are similar, triggering a longer length of products, which is greater than 1.5 kb and shorter than 2 kb. The 1:10 ratio, corresponding to 100 nM S3, 1 μM H1 and 1 μM H2 was optimal. However, the absorbance ratio at 450 nm was reduced from 100 to 200 nM of S3 and slightly went up at higher concentrations (Fig. 4B), indicating that 200 nM of S3 (corresponding to 1 μM H1 and H2) was optimal. Comprehensively, 200 nM of S3 was selected, considering the ideal signal amplification effect, the obvious signal report and no false positive results. Regarding the concentration of SA-HRP (Fig. 4C), the absorbance ratio at 450 nm was reduced until a stable region was achieved when the concentration of SA-HRP was denser than 500 ng/mL, demonstrating that the optimal dosage was 500 ng/mL in the absence of dissipation.

Figure 4: Optimization of HCR-based HRP concatemers.
figure 4

(A) EB-stained agarose gel electrophoresis demonstrated S3-initiated HCR: lane 1, 2000-bp marker from top to bottom was 2000, 1000, 750, 500, 250, and 100 bp; Lane 2, 1.0 μM H1; Lane 3, 1.0 μM H2; Lane 4, mixture of 1.0 μM H1 and H2; Lanes 5–10, the presence of S3 (100 nM, 150 nM, 200 nM, 400 nM, 500 nM, and 600 nM) with a mixture of H1 and H2. HCR time: 1 h. (B) Absorbance ratio (%) of the turn-off sensor with different concentrations of S3 (nM). The concentrations from the left are 100, 150, 200, 400, and 500 nM. (C) Absorbance ratio (%) of the turn-off sensor with different concentrations of SA-HRP (ng/mL). The concentrations from the left are 125, 250, 500, 750, and 1000 ng/mL. Error bars represent standard deviation (N = 3).

Characterization of HCR-based HRP concatemers

HCR products, serving as a typical non-enzymatic signal amplification element, were inspected by agarose gel electrophoresis as shown in Fig. 4A. The emission band demonstrate that HCR products were successfully formed. And the length of HCR products showed a S3 dose-response effect. When adding SA-HRP into biotinylated HCR nanostructures, an expected color change was appeared. It further confirmed that HCR-based HRP concatemers were successfully fabricated. The color change was attributed to HCR-based HRP complex could catalyze chromogen to produce chromogenic reaction. The detail color image were showed in Fig. S1. Then, transmission electron microscope (TEM) was further employed to observe the morphology of the assembled HCR-based HRP concatemers. As shown in Fig. 5A, morphology with helical concatemers was observed. The result suggested the successful formation of the HCR-based HRP concatemers. In addition, a comparison study with and without HCR-HRP have been conducted to give further validation. As shown in Fig. 5B, OD450 of the HCR-based system was obviously higher than that of the non-HCR system, and the sensitivity was noticeably improved, clearly indicating that the signal amplification effect of HCR process was significant, which was at least 4-fold greater than that in the non-HCR method.

Figure 5: The characterization of HCR-based HRP concatemers.
figure 5

(A) Transmission electron microscope (TEM) of HCR-based HRP concatemers. (B) Comparison of OD450 with different concentrations of Cu2+ (μM) between with and without HCR-HRP. Experimental conditions of HCR: SA, S1, S2, S3, H1/H2 and SA-HRP were 2 μg/mL, 120 nM, 120 nM, 200 nM, 1 μM/1 μM and 500 ng/mL, respectively; Experimental conditions of Non-HCR: SA, 5′, 3′-Biotin-S1, S2, and SA-HRP were 2 μg/mL, 120 nM, 120 nM and 500 ng/mL, respectively. The detection procedure was carried out as described in the Experimental section.

Optimization of Cu2+-mediated cleavage

Referring to the literature, a suitable dosage of ascorbate could apparently promote Cu2+-mediated cleavage of specific DNAzyme in slicing buffer (1.5 M NaCl, 50 mM HEPES, pH 7.0)42. Therefore, the influence of different concentrations of ascorbate ranging from 1 to 200 μM on visual readout was studied. As shown in Fig. 6A, the absorbance ratio at 450 nm was reduced and then increased at the concentration of 50 μM ascorbate. These results indicate that concentrations of ascorbate less than 50 μM enhanced the cleavage reaction, whereas concentrations greater than 50 μM suppressed the reaction. We concluded that 50 μM ascorbate in the slicing buffer was the ideal dosage, and this finding was consistent with Liu’s results42.

Figure 6: Optimization of Cu2+-mediated cleavage.
figure 6

(A) Absorbance ratio (%) of the turn-off sensor with different concentrations of ascorbate (μM). The ascorbate concentrations from the left are 1, 10, 25, 50, 75, 100, and 200 μM. (B) Absorbance ratio (%) of the turn-off sensor with the time of Cu2+-mediated cleavage (min). The time intervals from the left are 0, 3, 5, 10, 15, 30, 45 and 60 min. Error bars represent standard deviation (N = 3).

To promote our Cu2+ turn-off censor for on-site rapid detection, the time of Cu2+-mediated cleavage was researched. As shown in Fig. 6B, the following equation was used to characterize the cleavage efficiency: ΔOD450 (%) = [OD450 (negative control) −OD450 (sample)]/OD450 (negative control) × 100%7. The curve of cleavage efficiency rapidly ascended, reaching a plateau after more than 5 min. Three minutes after the addition of Cu2+ samples, the cleavage efficiency was greater than 80%. After 5 min, the efficiency reached 92%. Given that the immobilized Cu2+-dependent DNAzyme coupled with HCR-based HRP concatemers was prepared on the surface in advance, the actual reaction time after Cu2+ sample introduction was in 5 min, indicating great promise for on-site rapid testing.

Detection performance of the Cu2+ biosensor

As shown in Fig. 7A, given that the Cu2+-dependent DNAzyme was sensitive to the target ion when the concentration of Cu2+ present in samples increased from 0 nM to 100 μM, the final visual readout of the Cu2+ turn-off sensor decreased accordingly until reaching a plateau. The calibration curve was monitored by optical density at 450 nm with corresponding Cu2+ concentrations within the range of 50 nM to 3 μM. The linear regression equation was OD450 = −0.2376 × [c (Cu2+)] + 0.8068 (R2 = 0.9933), with the detection limit (LOD) of 8 nM according to 3σrule [mean absorbance of blank+3σ (standard deviation of the blank)]. According to the regulations introduced by the Chinese Ministry of Health, US EPA and WHO, the maximum permitted levels of Cu2+ in drinking water are 15 μM, 20 μM and 31 μM, respectively, and this detection limit is much lower than the regulated level. Moreover, the analytical performances of different optical DNAzyme-based assays developed for Cu2+ analysis are summarized, and the sensitivity of this proposed method is competitive compared with these techniques (Table S1).

Figure 7: Calibration curve and selectivity of the sensor.
figure 7

(A) Calibration curve for colorimetric determinations of different concentrations of Cu2+ by the turn-off sensor. Inset: Calibration plot and color change of Cu2+ concentration vs. absorbance signal in the range from 0.05 to 3 μM. The dotted line represents the linear fit to the data. Error bars represent standard deviation (N = 3). The chromogenic results (B) and OD450 (C) of the Cu2+ turn-off sensor before and 5 min after the addition of different metal ions of definite concentrations. Error bars represent standard deviation (N = 3).

The specificity of the Cu2+ turn-off sensor was evaluated by challenging the system against other metal ions, including Co2+, Ti2+, Fe2+, Fe3+, Mn2+, Ca2+, Ni2+, Mg2+, Zn2+, Cd2+, Pb2+, Hg2+, Ba2+, Sr2+, UO22+, Eu3+, Tb2+, Ag+, Al3+ and mixed ions. To evaluate the selectivity more accurately and more comprehensively, each metal ion mentioned above was analyzed at three different concentrations of 10 μM, 100 μM and 1 mM. As indicated in Fig. 7B and C, in contrast to the significant response of Cu2+ ion, other metal ions exhibited minimal interference with Cu2+ detection. Hence, the results exhibited high selectivity toward Cu2+ compared with other test metal ions given the specific function of the Cu2+-dependent DNAzyme.

Determination of Cu2+ in water samples

To further elucidate the analytical reliability and applicable potential of the Cu2+ turn-off sensor for testing real samples, three different water samples were monitored by using our developed Cu2+ sensor and ICP-MS. As shown in Fig. 8, a color chart was designed to assist the qualitative analysis and semi-quantitative LOD of 0.5 μM was clearly visualized by the naked eye. 0.5 μM, 1.5 μM and 2.5 μM of Cu2+ could be inspected by the naked eye semi-quantitatively. Therefore, more than 0.5 μM of Cu2+ could be inspected by the naked eye. In addition, the detection performance by our strategy for the water samples spiked with Cu2+ was compared with reference values obtained from ICP-MS, presented in Table S2. Bottled purified water samples, which were considered to contain fewer impurities, exhibited the best recovery results both in the case of low and high Cu2+ concentrations. Moreover, due to the presence of various mineral components, the detection results obtained from the lake water sample were slightly increased compared with bottled purified water samples. In contrast, the detection results of the water sample from domestic sewage were considerably increased compared with the spiked amount of the Cu2+ standard mainly due to the inherent Cu2+ residual in domestic sewage. In general, the detection results were similar between our strategy and ICP-MS in samples at different Cu2+ concentrations and the developed Cu2+ turn-off sensor exhibited satisfactory accuracy for Cu2+ detection in real water samples.

Figure 8
figure 8

Color chart and experimental images of real sample from bottled purified water, Lake water and Domestic sewage sample.

Conclusion

In conclusion, we constructed a rapid and visual turn-off sensor for Cu2+ detection, displaying several excellent features: (1) Turn-off type. The detection unit was composed of HCR-based HRP concatemers cross-linked with the substrate strand of Cu2+-dependent DNAzyme via Watson-Crick base pairing. Upon Cu2+ addition, Cu2+-dependent DNAzyme was irreversibly cleaved, bringing about dramatic decline of the signal output. Thus, the turn-off sensor could effectively get over false positives that interfere with the results. (2) Visualization. As the signal amplifier and signal report element, HCR-based HRP concatemers could catalyze hydrogen peroxide (H2O2) via TMB, generating obvious green color and turning yellow after sulfuric acid termination with optical absorption at 450 nm. The signal output could be semi-quantitatively observed by the naked eye with the minimum target of 500 nM and quantitatively monitored by a portable spectrophotometer with the LOD of 8 nM, demonstrating immense potential for on-site detection. (3) Sensitivity, Selectivity and anti-interference. The turn-off sensor possesses outstanding sensitivity, selectivity and anti-interference, exhibiting a linear calibration from 0.05 to 3 μM with a detection limit of 8 nM and displaying remarkable applicability for monitoring Cu2+ in real water samples, by virtue of the specificity of DNAzyme and the signal amplification of HCR-based HRP concatemers. (4) Rapidity. Given that the immobilized Cu2+-dependent DNAzyme coupled with HCR-based HRP concatemers was prepared on the surface in advance, the actual reaction time after the Cu2+ sample introduction was 5 min, indicating great promise for on-site rapid testing.

Additional Information

How to cite this article: Xu, W. et al. A rapid and visual turn-off sensor for detecting copper (II) ion based on DNAzyme coupled with HCR-based HRP concatemers. Sci. Rep. 7, 43362; doi: 10.1038/srep43362 (2017).

Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.