Obesity (2007) 15, 2371–2379; doi: 10.1038/oby.2007.281
Physical Activity Assessment With Accelerometers: An Evaluation Against Doubly Labeled Water**
Guy Plasqui* and Klaas R. Westerterp†
- *Department of Biomedical Science, University of Wollongong, Wollongong, Australia
- †Department of Human Biology, Maastricht University, Maastricht, The Netherlands
Correspondence: Klaas R. Westerterp Department of Human Biology, University of Maastricht, PO Box 616, 6200MD Maastricht, The Netherlands. E-mail: k.westerterp@hb.unimaas.nl
**The costs of publication of this article were defrayed, in part, by the payment of page charges. This article must, therefore, be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
Received 12 April 2006; Accepted 26 February 2007.
Abstract
This review focuses on the ability of different accelerometers to assess daily physical activity as compared with the doubly labeled water (DLW) technique, which is considered the gold standard for measuring energy expenditure under free-living conditions. The PubMed Central database (U.S. NIH free digital archive of biomedical and life sciences journal literature) was searched using the following key words: doubly or double labeled or labeled water in combination with accelerometer, accelerometry, motion sensor, or activity monitor. In total, 41 articles were identified, and screening the articles' references resulted in one extra article. Of these, 28 contained sufficient and new data. Eight different accelerometers were identified: 3 uniaxial (the Lifecorder, the Caltrac, and the CSA/MTI/Actigraph), one biaxial (the Actiwatch AW16), 2 triaxial (the Tritrac-R3D and the Tracmor), one device based on two position sensors and two motion sensors (ActiReg), and the foot-ground contact pedometer. Many studies showed poor results. Only a few mentioned partial correlations for accelerometer counts or the increase in R2 caused by the accelerometer. The correlation between the two methods was often driven by subject characteristics such as body weight. In addition, standard errors or limits of agreement were often large or not presented. The CSA/MTI/Actigraph and the Tracmor were the two most extensively validated accelerometers. The best results were found for the Tracmor; however, this accelerometer is not yet commercially available. Of those commercially available, only the CSA/MTI/Actigraph has been proven to correlate reasonably with DLW-derived energy expenditure.
Keywords:
physical activity, calorimetry, isotope, energy expenditure
MORE ARTICLES LIKE THIS
These links to content published by NPG are automatically generated.
RESEARCH
Measuring Free-Living Energy Expenditure and Physical Activity with Triaxial Accelerometry **Obesity Research Original Article
Triaxial Accelerometry for Assessment of Physical Activity in Young Children *Obesity Original Article
Evaluation of Low-Intensity Physical Activity by Triaxial Accelerometry **Obesity Original Article
Physical Activity-Related Energy Expenditure With the RT3 and TriTrac Accelerometers in Overweight Adults *Obesity Original Article
**&showall=research" class="allmatches" target="_new">See all 19 matches for Research