Main

Although it is straightforward to achieve acceleration gradients of 10–100 GV m−1 in laser-wakefield accelerators1,2, until recently the electron beams (e-beams) from such accelerators had energies <200 MeV with 100% energy spread 10. A breakthrough improvement in energy spread was obtained in 2004 by three groups3,4,5 by interacting intense laser pulses with millimetre-scale gas jets to generate 70–200 MeV beams with per-cent-level energy spread. For example, by using relatively large spot sizes, rs=18 μm (1/e2 radius of the laser intensity profile), 170 MeV e-beams were produced in 1–2-mm-long gas jets with the order of 0.5 nC bunch charge using 30 fs, 30 TW laser pulses5. Using a 2-mm-long preformed plasma channel2 in a gas jet to guide the driving laser beam4,11,12, enabled the production of 85 MeV e-beams containing 0.3 nC bunch charge, with only 9 TW of laser peak power.

To scale laser-driven accelerators to GeV electron energies and beyond, two approaches had been proposed: (1) operate in initially uniform plasmas7,13 with petawatt (PW)-scale lasers and large laser spot sizes, or (2) channel guide the laser beam over centimetre-scale distances2,14,15. Without guiding (for example, without self-focusing or preformed channels), the laser–plasma interaction length is limited to the order of the Rayleigh range, ZR, (a few millimetres for rs=25 μm). Relativistic self-guiding2,14 can extend the propagation distance of high-power pulses due to self-consistent modification of the plasma refractive index, but is limited by nonlinear effects such as the erosion of the leading edge of the laser pulse16. Obtaining GeV energies without a channel therefore requires large laser spot sizes that increase ZR, but also increase the required laser power to PW levels6,7 and can result in an undesirable increase in the e-beam emittance.

A more efficient approach relies on channelling laser beams with smaller spot sizes over centimetre-scale distances. Theory and simulation indicate that such channel-guided accelerators could produce GeV e-beams with 10–50 TW of laser power 2,4,14. However, simply making the accelerator longer is not sufficient. Phase slippage occurs between relativistic particles and the wake, because the wake has a phase velocity less than the vacuum speed of light. The linear dephasing length, Ld=λp3/λ2np−3/2, over which electrons outrun the wake and slip into the decelerating phase, limits the distance over which acceleration occurs. Here λp is the plasma wavelength, λ is the laser wavelength and np is the plasma density. For laser intensities I≤1018 W cm−2, a rough estimate of the electron energy gain over a distance Ld in a channel-guided laser-wakefield accelerator2,14 can be obtained from W (GeV)0.4I (Wcm−2)/np (cm−3)0.9(λp/rs)2P (TW); where P is the laser peak power (in TW). In the 2004 experiments, matching acceleration length to Ld led to the production of low-energy-spread e-beams3,4,5.

Previously we created plasma channels17 in a gas jet with the ‘ignitor-heater’ technique, where a plasma column is ionized and then heated by two precursor laser pulses4,11,18. Owing to laser heating being inefficient at low densities, suitable plasma channels could only be produced at densities >1019 cm−3, limiting Ld and restricting e-beam energies to about 100 MeV.

We overcame the limitations of gas-jet experiments by using a gas-filled capillary discharge waveguide8,9 to guide relativistically intense laser pulses in centimetre-scale, lower density plasma channels. The experiments used a 10 Hz repetition rate Ti:sapphire laser system (λ=810 nm) delivering pulses as short as 40 fs full-width at half-maximum with up to 40 TW peak power (Fig. 1). These pulses were focused by a 2 m focal length off-axis parabola (f/25) to rs=25 μm at the capillary entrance. The capillaries8 were laser-machined into 33-mm-long sapphire blocks with diameters ranging from 190 μm to 310 μm. Hydrogen gas, introduced through holes near the capillary ends, was ionized by striking a discharge between electrodes at the capillary ends. Measurements 8 and modelling19,20 showed that a fully ionized, approximately parabolic channel is formed. Previous experiments9 demonstrated channelling of non-relativistically intense laser pulses with I1017 W cm−2 in 30–50-mm-long capillaries, which did not generate e-beams.

Figure 1: Schematic diagram of the capillary-guided laser-wakefield accelerator.
figure 1

The plasma channel was formed in a hydrogen-filled capillary discharge waveguide (see inset). Hydrogen gas was introduced into the capillary waveguide using two gas slots in the 225 μm capillary and three in the 310 μm capillary. A discharge was struck between two electrodes located at each end of the waveguide, using a high-voltage pulser. The pulser used a 2.7 nF capacitor charged to 20 kV. The laser beam was focused onto the entrance of the capillary using an f/25 off-axis parabola (OAP). The guiding efficiency was measured using a pair of optical diodes (diode 1 and 2) that monitored the amount of laser energy at the entrance and exit of the capillary. The laser beam exiting the capillary was monitored on a 12-bit charge-coupled device camera (20 μm resolution), after having been attenuated with a pair of reflective wedges and optical attenuators. The e-beam was analysed using an integrating current transformer (ICT) and a 1.2 T broadband magnetic spectrometer (energy range of 0.03–0.15 and 0.175–1.1 GeV in a single shot). The e-beam was deflected downwards (into the page) and detected using phosphor screens imaged onto four synchronously triggered charge-coupled device cameras (not shown).

Guiding was optimized by adjusting the initial gas density and the delay between onset of the discharge current and arrival of the laser pulse (see Fig. 2a). Channel transmission correlated with discharge current (Fig. 2a) and, for low power (<5 TW), transmission was above 90% for densities ranging from 1.0 to 4.0×1018 cm−3 in a 100 ns timing window. Figure 2b,c shows laser beam profiles at the waveguide entrance and exit for 40 TW laser pulses with an input intensity 1018 W cm−2 and a plasma density of 2.7×1018 cm−3. This intensity is sufficiently high for large-amplitude wake generation, self-trapping and high-gradient electron acceleration as observed in the experiment (see below). The guiding performance was highly sensitive to input-beam alignment, with 15 μm displacement away from the optimum location (based on the quality of the guided beam) resulting in transmission drops of the order of 20%. Note that without a preformed plasma channel (laser injected ahead of discharge), transmission was below 5% and bulk damage was sustained to the capillary channel walls, indicating that self-ionization and relativistic self-focusing could not be relied on for guiding, as expected from short-pulse propagation theory16.

Figure 2: Capillary transmission at 5 TW peak input power versus time of arrival of the laser pulse after the onset of the discharge, and mode profiles of the input and output laser beam at 40 TW peak power.
figure 2

a, The discharge current (solid line, right axis) and laser pulse energy transmission (circles, left axis) versus arrival time of the laser at the capillary for laser pulses <5 TW. The dotted curve is the average transmission. b,c, The transverse spatial profiles of laser pulses with an input peak power of 40 TW at the entrance (b) and exit (c) of the 3.3-cm-long gas-filled capillary discharge waveguide (diameter=190 μm). The blue (red) curve is the horizontal (vertical) lineout. The horizontal and vertical spot sizes at the entrance were rsx=25 μm and rsy=27 μm, respectively, and rsx=31 μm and rsy=34 μm at the exit. The plasma density was 3.2×1018 cm−3. The 20% increase in spot size at the exit may be caused by imperfect mode matching. The energy transmission at this laser power was about 65%. Combined with the increase in laser spot size this results in a decrease in laser peak fluence from 1.3×105 J cm−2 to 0.5×105 J cm−2. Assuming that the laser pulse duration remains constant between the entrance and exit of the capillary, the peak intensity of the laser was reduced from 3 to 1.2×1018 W cm−2.

Electron bunch energy was measured by a 1.2 T single-shot magnetic spectrometer that deflected the electrons vertically downwards onto a 1.2-m-long phosphor screen, covering energies from 0.03 GeV to 1.1 GeV. E-beam divergence and energy spread were calculated from the data assuming a symmetric e-beam profile, and by using the imaging properties of the spectrometer, obtained from magnetic field maps and a second-order electron transport model21. Divergence was determined from the e-beam size in the horizontal plane, taking into account the transverse defocusing properties of the magnet. Energy spread was calculated by deconvolving the effect of finite divergence from the measured e-beam profile. Charge was obtained from the phosphor screen, which was cross-calibrated against an integrating current transformer.

Figure 3 shows energy spectra of (a) 0.5 GeV and (b) 1.0 GeV beams, obtained with 12 TW (73 fs input) and 40 TW (38 fs input) laser pulses, respectively. In both cases the e-beams had per-cent-level energy spread and a divergence of 1.2–2.0 mrad (r.m.s.).

Figure 3: Single-shot e-beam spectra of the capillary-guided accelerator.
figure 3

a,b, Examples of bunches at 0.50+0.02−0.015 GeV (5.6% r.m.s. energy spread, 2.0 mrad divergence r.m.s., 50 pC charge) (a) and 1.0+0.08−0.05 GeV (2.5% r.m.s. energy spread, 1.6 mrad divergence r.m.s., 30 pC) (b). The horizontal axis is the beam energy and the vertical axis is the beam size in the undeflected (horizontal) plane. The colour scale denotes the bunch charge in pC GeV−1 sr−1. The 0.5 GeV (1.0 GeV) beam shown was obtained in the 225 (310) μm capillary with a density of 3.5×1018 (4.3×1018) cm−3 and input laser power of 12 TW (40 TW). The black stripe denotes the energy range not measured by the spectrometer. In b, a second beam at 0.8 GeV is also visible. Note that the energy spread and divergence are obtained after including the imaging properties of the spectrometer. The energy spread at 1 GeV may actually be less as the energy resolution is limited to 2.4% at 1 GeV and there is slight saturation of the image. c,d, Vertically integrated spectra for the 0.5 (c) and 1.0 GeV (d) beams. The vertical axis is the charge density in pC GeV−1. The vertical error bar arises from uncertainty in calibration of the phosphor screen as a charge monitor (±17%). The horizontal error bar is due to the uncertainty in entrance angle of the e-beam resulting in an uncertainty in its energy. The spectrometer did not use an input slit, but the angular acceptance was limited by the transport beam pipe. For the 0.5 GeV (1 GeV) beam, this gives an uncertainty in central energy of +2%,−1.5% (+8%,−5%). In addition, for the 0.5 GeV beam, sufficient statistics were obtained to include the shot-to-shot fluctuation, which amounted to ±5% in mean energy and ±30% in charge. Hence, the convolution of those factors are shown in c, which are +5.4%,−5.2% in mean energy and ±34% in charge. The fluctuation in central energy was correlated with fluctuations in laser power.

Beams at 0.5 GeV were obtained using a 225-μm-diameter capillary for a density of 3.2 to 3.8×1018 cm−3 and for laser power ranging from as low as 12 TW (using 73 fs) to 18 TW (using 40 fs). The laser pulse energy transmission was observed to decrease from near 100% for input powers below 5 TW to less than 70% for input powers above 18 TW, consistent with laser energy transfer to the wake and e-beams.

The performance of the 225-μm-diameter capillary-guided accelerator was found to be reproducible for delays between the laser arrival and onset of the discharge of 80–110 ns (that is, a 30 ns timing window) and 12 TW laser peak power. Every laser shot resulted in an e-beam at 0.48 GeV±6% and an r.m.s. spread <5%. Fluctuations in e-beam energy were directly correlated with those in laser power. For lower power (<12 TW) no e-beams were observed, suggesting that the wake amplitude was below the self-trapping threshold. For higher power (>12 TW), the e-beam spectra typically showed significant structure (larger spread and multiple spots) and had much larger divergence, consistent with the wakefields exhibiting strong transverse structure in these relatively narrow channels, with a correspondingly strong impact on trapping (transverse wavebreaking) and focusing of the beams. In addition, the e-beam energy was lower and the bunch charge higher, suggesting that at these higher power levels more particles are trapped and that trapping occurs sooner in the channel, resulting in significant beam loading and reduction of the wakefield as well as improper matching of the acceleration length to Ld.

The GeV e-beam was obtained in a 310-μm-diameter channel capillary for P=40 TW and a density 4.3×1018 cm−3. In this larger diameter channel, transverse wakefields are reduced but the guiding properties are less ideal as this capillary requires a larger input spot size for matching than was used in the experiments. For lower laser power (<38 TW), no e-beams were observed. For higher laser powers, the spectrum always showed structure with significant shot-to-shot fluctuations due in part to the self-trapping mechanism being sensitive to small variations in the laser and plasma parameters11. The dynamics of trapping, dephasing, beam loading11,22 and hosing23 may be responsible for the second spatially displaced bunch observed near 0.8 GeV in Fig. 3b. Such features are observed in numerical simulations, owing to trapping of a second electron bunch in a wake bucket behind the first11,22. These issues as well as the importance of matching Ld in these structures are being further explored.

Although the performance of the accelerator at 1 GeV (310-μm-diameter capillary) was less stable than at 0.5 GeV (225-μm-diameter capillary), it demonstrates the possibility of compact GeV accelerators driven by only a few tens of TW of laser power. To ensure stability may require some means of controlled particle injection via laser triggering24,25.

For rs=25 μm, the simple scaling law discussed above predicts 0.27 GeV using 18 TW and np=3×1018 cm−3; and 0.5 GeV using 40 TW and np=4×1018 cm−3. These values are about a factor of two lower than the measured maximum electron energy (Fig. 3). Contrary to the experiment, however, the simple scaling laws do not include the full channel properties, nor effects of laser pulse evolution, self-focusing and e-beam loading on the plasma wake. For example, simulations indicate that pulse evolution is essential to the trapping and acceleration process. As the pulse propagates, it self-modulates and steepens such that the plasma electrons are completely blown out from the region of the axis (cavitation or bubble regime13), at which point electrons are self-trapped and accelerated from the background plasma in a manner similar to that described in previous experiments on high-quality beam production at the 100 MeV level 4,11.

The GeV-class electron beams from these centimetre-scale structures offer unique applications. The short wavelength of the plasma accelerating structure results in femtosecond-duration bunches26 (>10 kA peak current), well suited for driving pulsed radiation sources. These devices may allow compact femtosecond free-electron lasers producing keV X-rays using existing centimetre-scale period undulators and, in general, provide intrinsically synchronized sources of femtosecond pulses of electrons and radiation tunable from X-ray27 to THz 28 frequencies. Furthermore, it is anticipated that longer accelerating structures can be made by staging capillary discharge waveguides, thereby opening a path to compact accelerators beyond the multi-GeV level for high-energy physics applications.