Main

An electron is an elementary particle which carries internal angular momentum called an electron spin. The recent development of nanotechnology has enabled spins to be used to form a new field called spintronics. Various phenomena found in spintronics originate from angular-momentum exchange between the spin and other degrees of freedom, such as magnetization7,8 and light polarization9,10,11; so far, many degrees of freedom have been united into this angular-momentum exchange framework. However, the exchange has not been observed for the most common and ordinary carrier of angular momentum—namely, mechanical rotation of material objects.

The interaction which combines mechanical angular momentum and electron spin is called spin–rotation coupling12,13. With this coupling, mechanical rotation gives rise to spin voltages and spin currents. Here, the spin voltage is the driving force for a spin current, represented by μSμμ, where μ and μ respectively denote the electrochemical potential for spin-up and spin-down electrons16,17; a gradient of spin voltage drives a spin current.

To generate a gradient of spin voltage from mechanical motion, we have used flows of a liquid metal (Fig. 1a), as a gradient of mechanical rotation can easily be generated in a fluid. To describe spin voltage generation in a liquid, we expanded the angular-momentum conservation law for fluid dynamics to include angular-momentum transfer between a liquid and an electron spin. By introducing an antisymmetric stress tensor to the equation of motion for a liquid, the angular momentum of a fluid is predicted to be transferred into the electron spin (see Supplementary Information for details). The obtained equation for the spin voltage μS (the vector indicates a polarized direction) is

where λ is the spin-diffusion length18 and ξ is related to the fluid viscosity caused by the angular-momentum transfer, which is added to the viscosity coefficient of a Newtonian fluid. The vorticity24ω ≡ rot v represents local mechanical rotation of a fluid, where v is the fluid velocity (Fig. 1b). Equation (1) implies that the vorticity acts as a spin-current source (Fig. 1c).

Figure 1: Concept of spin hydrodynamic generation.
figure 1

a, Schematic illustrations of conventional magnetohydrodynamic generation (left) and spin hydrodynamic generation (right). The left panel shows that a fluid flow in a magnetic field generates an electric voltage perpendicular to the flow. The right panel shows that a liquid-metal flow generates a spin voltage, the driving force for a spin current, along the vorticity gradient. b, Schematic illustration of the velocity v and vorticity ω distribution in a liquid flow confined in a channel. A translational motion with different v in a local region of a flow exhibits local rotational motion, whose angular velocity is proportional to ω ≡ rot v. c, Schematic illustration of the mechanically induced spin voltage μS and spin current jS. A diffusive spin current flows along the gradient of μS, or ω. d, Schematic illustration of the inverse spin Hall effect (ISHE) in the fluid. EISHE denotes an electric field. e, Schematic illustration of mechanical spin-current generation in a cylindrical fluid channel. vz, ωθ, jS and Ez are, respectively, the flow velocity, the vorticity, the mechanically induced spin current [jS ≡ −(σ0/4e2)(/∂r)μSθ] and the ISHE electric field. ω is along an azimuthal direction (θ) and has its spatial gradient along a radial direction (r). A spin current induced by the gradient of ωθ flows along the r-direction.

To detect spin voltage in a fluid, we have used the inverse spin Hall effect17,19,20,21,22 (ISHE). The ISHE converts a spin current into an electric field EISHE through the spin–orbit interaction of electrons. The spin current jS carries the spin σ. The relationship between EISHE and jS is given by

where σ0 and θSHE are the electrical conductivity and the spin Hall angle, respectively. By measuring EISHE, the ISHE can be used to detect a spin current precisely (see Fig. 1d).

Figure 1e shows the geometry for mechanical spin-current generation in a cylindrical fluid channel used in the present study. In the channel, the vorticity ω is generated as a result of the viscosity near the inner wall and lies along the azimuthal direction (θ). Therefore, equations (1) and (2) predict a spatial gradient of μS along the radial direction (r) and the generation of EISHE due to the ISHE of a liquid metal along the axial direction (z).

Figure 2a shows a schematic illustration of the measurement set-up. In this set-up, we generate a flow of liquid metal mercury (Hg) in a cylindrical channel by applying a pulsed pressure ΔP. The channels consist of a quartz pipe and platinum (Pt) thin wires as electrodes embedded in the channel wall and electrically connected to the liquid metal via a pinhole to avoid disturbance of the fluid flow. The channel has to be an insulator for spin hydrodynamic (SHD) measurements to avoid thermoelectric effects between the channel and the liquid metal. The electrode material is chosen as Pt because of its weak chemical reactivity and its absolute thermopower being close to that of Hg; the observed relative Seebeck coefficient is SHg−Pt = + 0.06 μV K−1. The inner diameter and the length of the channel (the distance between the electrodes) are denoted as φ and L, respectively. To prevent it from charging up electrically, the Hg is connected to the ground at the inlet. We measured the electric voltage difference V between the ends of the channel filled with Hg. All the measurements were performed at room temperature.

Figure 2: Electromotive force measurements.
figure 2

a, Schematic illustration of the experimental set-up. A flow of liquid Hg is induced by applying a pulsed pressure ΔP. V denotes the electric voltage difference between Pt electrodes (diameter: 0.1 mm) embedded into the channel ends. L (mm) is the distance between the electrodes. The inset shows the velocity vz distribution24 of turbulent flow in a pipe (see Supplementary Information for details). δ0 is the thickness of the viscous sublayer. b, Time evolution of V for two flow directions: one is a flow injected from the side l (see a) and the other is one from the side h. In both cases Hg is connected to the ground at the inlet. The mean flow velocity is 2.7 m s−1. The flow is started at t = 0 and switched off at t = Δt (= 5.9 s). φ (mm) is the inner diameter of the channel. c, ΔP dependence of the mean flow velocity v for the channel used in b. The experimental data (open circles) are reproduced well by a broken curve24 representing . d, Time evolution of V for various values of ΔP in the same channel as b. e, v dependence of V for different φ and L. In each measurement with L = 80 mm, V was estimated by taking a time average, whereas when analysing the case with L = 400 mm, V was estimated by taking an average of the steep changes of a voltage signal (see b) observed on switching on and off the flow. All the measurements for different values of v have been carried out more than three times and an average of the results for each v is plotted. Error bars are defined as one standard deviation. f, vr0 dependence of r03V/L. A fit curve is obtained from equation (3). Each error bar was calculated by converting the errors in e. Inset shows the relation between v and v calculated for different φ values.

Figure 2b shows the time evolution of V measured in the liquid Hg. The liquid flow in the channel starts at time t = 0 and ends at t = Δt. A clear V signal appears when Hg is flowing, as shown in Fig. 2b. The sign of V is reversed on reversing the flow direction. This unconventional voltage behaviour is the feature predicted for the ISHE induced by a mechanical motion described above: the direction of EISHE is predicted to be reversed by reversing the ω direction or the Hg flow direction (see Fig. 1e and equation (2)).

To further examine the voltage generation, we measured V for various values of mean flow velocity, v, and for several channels with different φ and L values. v is modulated by changing ΔP; the measurement result, shown in Fig. 2c, is reproduced well by the relation for a turbulent flow in a pipe24, being consistent with the fact that its Reynolds number, , satisfies the turbulent flow condition, , where ν is the kinetic viscosity. The time evolution of V shown in Fig. 2d clearly illustrates that the magnitude of V increases with increasing ΔP, or the mean flow velocity v. Figure 2e shows the friction velocity24 (v) dependence of V for channels with different φ and L values. The result shows that V increases with v but with different slopes for the different channels. Here, v is directly related to the ω gradient in a turbulent flow: the vorticity of a turbulent flow, ωθ(r), in a pipe is described24 by ωθ(r) = v2/ν in the region close to the wall, called the viscous sublayer, with ωθ(r) = v/[κ(r0r)] elsewhere. κ is the von Kármán constant and r0φ/2. The relationship between v and v for different φ is shown in the inset to Fig. 2f, which was calculated24 by averaging the velocity distribution of the turbulent flow in the pipe.

In this way, different channels were found to exhibit different V behaviour. However, we predict a scaling rule on the behaviour as follows. A spin voltage can be generated from ωθ(r) as a result of the spin–rotation coupling, and the spatial gradient of the spin voltage is then converted into spin currents in the liquid metal and into an electric voltage via the ISHE:

where C0 ≡ (4|e|/κ)((θSHEλ2ξ)/σ0), (11.6 for the present study), and δ0 is the thickness of the viscous sublayer (see Supplementary Information for detailed derivation). This formula predicts that r03V/L exhibits a universal scaling with respect to vr0, identifying that the V signal is generated from the spin current.

In Fig. 2f, we replot all the data from Fig. 2e for different channels into a r03V/L versus vr0 scale. In this plot, surprisingly, all the different data collapse onto a single curve. This universal scaling behaviour is the very feature predicted above equation (3), demonstrating that the observed V signal is due to the ISHE induced by mechanically generated spin currents.

By fitting the data in Fig. 2f with equation (3), the parameter θSHEλ2ξ is estimated to be 5.9 × 10−25 J s m−1. If we assume typical magnitudes18,23 of θSHE and λ (θSHE 10−2 and λ 10−8 m), ξ is then estimated to be 6 × 10−7 J s m−3, or ξ/μ 4 × 10−4, where μ is the Newtonian viscosity. Here, we used parameters from ref. 24 for Hg: σ0 = 1.01 × 106 (Ω m)−1, ν = 1.2 × 10−7 m2 s−1 and μ = 1.6 × 10−3 J s m−3.

We also carried out measurements on Ga62In25Sn13(GaInSn), another chemically stable liquid metal (melting point: 5 °C), whose spin–orbit coupling may be weaker than that in Hg because all atoms comprising GaInSn are lighter than Hg. In the measurements, because an appropriate material is not available for the electrode in GaInSn, we used a special set-up, called a triangle set-up; the details of the set-up are explained later. Figure 3a shows the ΔP dependence of v in GaInSn and Hg. The velocity of GaInSn is faster than that in Hg because of the density difference. Figure 3b, c shows v versus V plots of GaInSn and Hg, and the time evolution of V for various values of ΔP in GaInSn, respectively. The data show that V is slightly suppressed by substituting Hg for GaInSn. Equations (1) and (2) phenomenologically indicate that the conversion from the vorticity into the voltage depends on θSHE and λ. When spin–orbit coupling decreases, θSHE decreases whereas λ tends to increase. Therefore, the effects of spin–orbit coupling on V partially compensate, resulting in the weak material dependence obtained from the GaInSn and Hg measurements. If we assume θSHEλ2ξ for GaInSn to be 3.0 × 10−24 J s m−1, equation (3) reproduces the observed V values. Here, we used parameters from ref. 25 for GaInSn: σ0 = 3.1 × 106 (Ω m)−1 and ν = 2.98 × 10−7 m2 s−1.

Figure 3: Experimental results for GaInSn and comparison of voltage with inner-wall material.
figure 3

a, ΔP dependences of v for Hg (open symbols) and GaInSn (blue filled symbols) in the triangle set-up shown in Fig. 4a (φ = 0.4 mm; L = 102 mm). b, v dependence of V for Hg (open symbols) and GaInSn (blue filled symbols) in the triangle set-up. c, Time evolution of V of a GaInSn flow for various values of ΔP. The flow starts at t = 0 and is switched off at t = 10 s. d, Examination of the influence of contact electrification. The v dependence of V for the channel whose inner wall is coated with resin (filled circles) exhibits almost the same behaviour as that for the uncoated quartz pipe (broken curve: a fit curve of the data shown in Fig. 2f). The voltage signal V was estimated in the same way as the uncoated quartz pipe case with L = 400 mm shown in Fig. 2e. Error bars are defined as one standard deviation.

Now, we examine the possibilities of other mechanisms that might give rise to voltage signals in the present set-up. First, the magnetohydrodynamic effect1,2,3,4 (MHD), or the effect of the Lorentz force on a liquid-metal flow caused by environmental magnetic fields, was found to be negligible; the electromotive force caused by the MHD is perpendicular to the liquid flow, and thus the voltage caused by the MHD should not depend on the length of a channel, which is contradictory to the observed signal. Also, we confirmed that the observed signal is not affected by the direction of the geomagnetic field.

Next, we examine contact electrification effects26,27,28,29, or the influence of charging effects of Hg due to electrochemical interaction with a channel wall, even though the Hg is connected to the ground. A flow of charged Hg might generate electric voltage in itself. The charging effect is known to depend on the material species26,27,28 and roughness29 of the contact surface. To change the property of the contact surface, we coated the inner wall of the channel with resin and measured V using the coated channel. Resin is known to exhibit different electrification properties from quartz26,27. The values of φ and L for the channel are 1.0 mm and 400 mm, respectively. The magnitude of the roughness was also changed approximately from 5 to 40 μm by the coating. As shown in Fig. 3d, the result indicates that the v dependence of V for the resin-coated channel is the same as that for the uncoated quartz channel, ruling out the contribution of the charging effect.

Finally, we examine the influence of thermoelectric effects. We constructed the special set-up shown in Fig. 4a. We call it the triangle set-up. This set-up allows us to completely eliminate the Seebeck voltage and to examine thermoelectric contamination in the SHD measurements. In the set-up, the voltage probes consist of Hg itself, allowing the voltage to be transferred to a common location for the attachment of wiring, as shown in Fig. 4a. Therefore, thermoelectric contamination is completely removed as follows. In Fig. 4b, we show the voltage signal generated in the triangle set-up filled with Hg, measured by applying a temperature difference ΔTH between the ends of the fluid channel, but without flowing Hg. The maximum magnitude of ΔTH is 20 K, much greater than the possible temperature difference in the liquid flow (approximately 0.1 K; see experimental results in Supplementary Information). Note, however, that no noticeable thermoelectric voltage is observed in going from a small to a large ΔTH, which shows that the thermoelectric effect is completely excluded in measuring the SHD signal. In fact, as shown in Fig. 4c, d, we observed flow-induced voltage signals in the triangle set-up, similar to those in the set-up shown in Fig. 2a (the simple set-up). Compared to this flow-induced signal in the triangle set-up, the thermoelectric signal in Fig. 4b is negligibly small even in the presence of a large temperature difference, proving that both the set-ups work perfectly to measure the SHD signal. To confirm this we compared the flow-induced voltage signal in the triangle set-up shown in Fig. 4c and that in the simple set-up shown in Fig. 4d; they are similar in terms of the flow velocity dependence and the signal magnitude. All the results indicate that the voltage signal generated in the liquid flow is completely unrelated to thermoelectricity.

Figure 4: Measurements in triangle set-up.
figure 4

a, Schematic illustration of the triangle set-up, in which liquid-metal electrodes are used. Two quartz pipes (inner diameter: 1.0 mm, length: 100 mm) filled with Hg are used as electrodes. To avoid liquid-flow disturbance, the electrode pipes are connected to liquid reservoirs near the inlet or the outlet of the fluid channel (φ = 0.4 mm, L = 102 mm). The other ends of the electrode pipes are placed in close proximity to each other to realize an isothermal condition and are connected to a nanovoltmeter. b, Voltage measured without a fluid flow versus temperature difference between the ends of the fluid channel, ΔTH. The temperature difference is monitored with a T-type thermocouple. r.t. stands for room temperature. c,d, Time evolution of the fluid-flow-induced voltage V in the triangle set-up (c) and in the simple set-up (d). Voltage signals appear when Hg flows with velocity v on applying a pulsed pressure.

From the point of view of applications, the observed generation effects can be used to make an electric generator and a spin generator without using magnets. It is thus certainly worthwhile to explore the effect in various liquid metals. We anticipate that the observed phenomena will bridge the gap between spintronics and hydrodynamics.