Article abstract
Nature Photonics 1, 709 - 716 (2007)
Published online: 25 November 2007 | doi:10.1038/nphoton.2007.228
Subject Categories: Imaging and sensing | Biophotonics
Three-dimensional endomicroscopy using optical coherence tomography
Desmond C. Adler1, Yu Chen1, Robert Huber1,2, Joseph Schmitt3, James Connolly4 & James G. Fujimoto1
Abstract
Optical coherence tomography enables micrometre-scale, subsurface imaging of biological tissue by measuring the magnitude and echo time delay of backscattered light. Endoscopic optical coherence tomography imaging inside the body can be performed using fibre-optic probes. To perform three-dimensional optical coherence tomography endomicroscopy with ultrahigh volumetric resolution, however, requires extremely high imaging speeds. Here we report advances in optical coherence tomography technology using a Fourier-domain mode-locked frequency-swept laser as the light source. The laser, with a 160-nm tuning range at a wavelength of 1,315 nm, can produce images with axial resolutions of 5–7
m. In vivo three-dimensional optical coherence tomography endomicroscopy is demonstrated at speeds of 100,000 axial lines per second and 50 frames per second. This enables virtual manipulation of tissue geometry, speckle reduction, synthesis of en face views similar to endoscopic images, generation of cross-sectional images with arbitrary orientation, and quantitative measurements of morphology. This technology can be scaled to even higher speeds and will open up three-dimensional optical-coherence-tomography endomicroscopy to a wide range of medical applications.
- Department of Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA
- Lehrstuhl für BioMolekulare Optik, Fakultät für Physik, Ludwig-Maximilians-Universität München, 80538 München, Germany
- Lightlab Imaging, Westford, Massachusetts 01886, USA
- Department of Pathology, Beth Israel Deaconess Medical Center, Boston, Massachusetts 02215, USA
Correspondence to: James G. Fujimoto1 e-mail: jgfuji@mit.edu
MORE ARTICLES LIKE THIS
These links to content published by NPG are automatically generated.
RESEARCH
High-resolution optical coherence tomography imaging of the living kidneyLaboratory Investigation Technical Report
Comprehensive volumetric optical microscopy in vivoNature Medicine Technical Report (01 Jan 2007)
Interferometric synthetic aperture microscopyNature Physics Article (01 Feb 2007)
Terahertz Pulse Imaging of ex vivo Basal Cell CarcinomaJournal of Investigative Dermatology Original Article