Nature Methods
- 4, 828 - 833 (2007)
Published online: 27 September 2007; | doi:10.1038/nmeth1094
MALDI imaging mass spectrometry: molecular snapshots of biochemical systemsDale S Cornett, Michelle L Reyzer, Pierre Chaurand & Richard M CaprioliThe authors are at the Mass Spectrometry Research Center, 465 21st Avenue, Vanderbilt University Medical Center, Nashville, Tennessee 37232, USA. r.caprioli@vanderbilt.edu Matrix-assisted laser desorption/ionization (MALDI) imaging mass spectrometry (IMS) is emerging as a powerful tool for investigating the distribution of molecules within biological systems through the direct analysis of thin tissue sections. Unique among imaging methods, MALDI-IMS can determine the distribution of hundreds of unknown compounds in a single measurement. We discuss the current state of the art of MALDI-IMS along with some recent applications and technological developments that illustrate not only its current capabilities but also the future potential of the technique to provide a better understanding of the underlying molecular mechanisms of biological processes.Understanding the complex biochemical processes that occur within living organisms requires not only the elucidation of the molecular entities involved in these processes, but also their spatial distribution within the organism at any point in its developmental cycle. It follows then that analysis tools should provide as much information as possible about a sample, including the identity of all species present and how they are distributed. The complexity of this task is immense, but it is made possible by innovative molecular analytical technologies of high sensitivity that allow for the identification of the biological molecules and their distribution in the organism. Chemical stains, immunohistochemical tags and radiolabels are common methods for visualizing and identifying molecular targets. However, there are limits to the specificity of these methods and to the number of target compounds which can be monitored simultaneously. Moreover, use of specific molecular tags requires a priori knowledge of the target species, thereby limiting their utility for molecular discovery.
Imaging mass spectrometry (IMS) is an emerging technology that combines the multichannel (m/z) measurement capability of mass spectrometers with a surface sampling process that allows one to rapidly probe and map the proteomic and small molecule content of tissues. Each ion measured is thus registered to a specific location in the sample, which facilitates rendering of the data into spatial distribution maps, or images, for the many hundreds of ions measured in the mass spectra. The images are, therefore, independent measures of the distribution of the respective compounds. The concept of using mass spectrometers to produce molecular images goes back several decades. However, a broad review of this field is beyond the scope of the current article (for a brief description of alternative technologies for IMS, see Box 1).
We focus here on the use of MALDI mass spectrometry for imaging, a technology that has broad applicability to biological research. A unique feature of this technology is its ability to analyze complex mixtures ranging from small drug compounds to very large proteins. Early on, molecular analysis using MALDI mass spectrometry was employed in studies of intact cells1,
2,
3 to produce characteristic molecular fingerprints. Later, the first reports of MALDI-IMS showed that spatial distributions of molecules could be rendered from a two-dimensional array of MALDI mass spectra acquired directly from thin sections of tissue4,
5. By plotting ion intensity as a function of x and y coordinates on the section, unique distribution maps can be produced for each of the many hundreds of ions produced from the section. Key advantages of this technology are that it does not require molecule-specific tags or chemical modifiers to facilitate detection and does not rely on any prior knowledge of the tissue proteome. This allows the discovery of protein markers that are either highly localized within specific tissue structures or expressed for only a brief time during the stages of development.
Interest in MALDI-IMS has grown rapidly, enhanced by the recent introduction of commercial devices for sample preparation and data acquisition and analysis. With MALDI-IMS instrumentation more readily available, studies are being published at an increasing rate. Much of the interest in MALDI-IMS has been for exploring disease pathology6,
7,
8 and for pharmaceutical applications9,
10,
11,
12. The technique continues to advance these fields, but new applications are expanding the technology into fields such as developmental and systems biology. We discuss methodological developments and applications of MALDI-IMS that have emerged during the past two years and provide a perspective for coming years.
Methodology MALDI-IMS uses the basic matrix-assisted laser desorption/ionization process for the analysis of spatially discrete areas of a sample. Tissue samples are typically thin sections, 5–20 m thick, that have been spray-coated or microspotted with MALDI matrix. Once the sample has been placed inside the mass spectrometer, spectra are acquired at discrete locations about the sample surface according to a predefined rectangular x,y grid. The resulting dataset therefore contains an array of spectra in which each spectrum is an independent molecular profile of the area irradiated by the laser. Individual grid-cells can be thought of as 'pixels', each composed of a spectrum of thousands of signals of measured mass and intensity. The intensity of any given signal, or combinations of signals, can then be plotted on the original coordinate system, generating an image of that signal over the sample surface. Thus, in a relatively short time, a MALDI-IMS analysis yields hundreds of such relative distribution maps. The overall process is illustrated in Figure 1.
 | |  | Sample handling and preparation of sections for image analysis are critical to the spatial integrity of measured molecular distributions. Obviously, any molecular degradation that occurs in the time between sample collection and analysis can adversely affect the results. A typical study may involve samples collected over a lengthy period of time, and standardized procedures are therefore required to minimize experimental variability over the time course of the study. Our experience shows the need for good communication among all personnel involved with collecting, storing and analyzing samples. Ideally, samples are frozen immediately after collection and stored until sections for MALDI-IMS analysis are cut on a cryomicrotome just before analysis. Once sections are cut, they are transferred to the MALDI plate and affixed through thaw-mounting or other mechanical means such as double-sided tape. Sucrose and polymer-based embedding media have been found to inhibit ion production if these are transferred to the surface of the section during the cutting process, and their use is discouraged8. Chemical fixation procedures such as formalin fixation that act by crosslinking proteins can inhibit molecular analysis. However, the many hundreds of thousands of chemically fixed samples banked in various institutions around the world constitute a potentially rich cohort for study, and early efforts to develop methods for analyzing these have shown promise13.
The application of MALDI matrix to mounted sections is a critical determinant of spatial resolution as well as the number of unique ions detected. The most common and least expensive devices available for applying matrix are hand-held aerosol sprayers or airbrushes. The chief advantage of these devices is that, with careful application, a dispersion of very small droplets of matrix solution can be delivered onto the sample surface to form a homogeneous layer of crystals that are typically no larger than the diameter of the focused laser of the mass spectrometer (usually 50–100 m). As a result, the diameter of the laser beam determines the smallest surface area or pixel size that is represented by a single mass spectrum. However, overspraying the matrix increases the likelihood of analyte migrating away from the location from which it was extracted, whereas underspraying delivers to the surface a limited amount of solvent for extracting analyte. Automated sprayers minimize much of the operator variability, and several such devices are now available commercially. Early results from these devices are promising, but application of matrix to areas larger than the diameter of the aerosol requires repeated overlapping passes, which in turn may cause some artificial variations in ion intensity. These can, however, be partially corrected through data processing14.
An alternative to aerosols is the delivery of matrix solution to the sample in the form of very small droplets from precision ejectors. Two different types of ejectors have been incorporated into such devices: inkjet-style piezo nozzles15 and focused acoustic dispensers16. Both designs operate by drop-on-demand, producing highly reproducible drops of approximately 100 pl that dry to form crystalline matrix spots of 150 m diameter. Aerosol-generated droplets can be smaller in size, but spotting devices offer advantages of droplet uniformity and precision of placement, both of which translate into greater control over protein extraction. However, because spotted matrix is generally larger than the focused laser spot, it is the size of the droplet, or more accurately the surface area wetted by the droplet, that determines the maximum achievable spatial resolution. The typical operating mode is to 'print' an array of discrete microspots over the area to be imaged. The pitch of the array of matrix spots, which is typically 150–300 m, is approximately 2–5 times lower than the maximum image resolution achieved with aerosols. This is offset somewhat by the fact that any lateral diffusion of analyte molecules is confined to the area covered by the droplet. In addition to controlling analyte extraction, the ability to deposit precisely onto the same location multiple times makes it possible to explore the products of chemical or enzymatic reactions in situ simply by changing the solution being spotted.
Almost any modern MALDI mass spectrometer can be configured for IMS analyses. Owing to their widespread availability, high sensitivity and unlimited m/z range, time-of-flight (TOF) mass analyzers are commonly used. MALDI-TOF instruments incorporating fast (>200 Hz) lasers permit data acquisition rates on the order of 1–2 spectra per second with the sensitivity to detect hundreds of proteins from an area containing only a few cells. However, for image analysis of small molecules there can be considerable interference from abundant matrix-related ions, particularly when both the target species and the interfering compound have the same integral molecular weight. These cases require an alternative approach such as the use of tandem mass spectrometry (MS/MS) and selected reaction monitoring (SRM), in which the molecular ion of the analyte is fragmented, and images are generated from one or more analyte-specific fragment ions. This approach has been extensively used for the analysis of drugs and their metabolites9,
12,
17,
18,
19,
20, as well as for endogenous lipid species21,
22. Tandem mass spectrometry eliminates much of the chemical background that is present in the low molecular weight range.
A number of laboratories are pursuing the development of new instrumentation, seeking to improve the spatial resolution, molecular sensitivity and speed of the analysis. Scanning laser microprobe instruments with advanced laser optics offer high-resolution image analysis of tissue samples with pixel dimensions on the order of 10 m (ref. 23,24). A microscope-mode instrument has been reported that maintains the spatial relationship of ions desorbed from within the area irradiated by the laser. This instrument is capable of resolving spatial features within the area irradiated by a laser beam, focused to a relatively large diameter of 200 m, to produce an effective spatial resolution of 4 m (ref. 25). The high mass-resolving power of Fourier transform mass spectrometers allows imaging of isobaric ions26,
27. Instruments like these offer some unique advantages, but they are still early in development. Presently, the widespread availability of TOF, quadrupole-TOF and ion trap systems make these the instruments of choice.
Applications MALDI-IMS applications are typically classified into two broad categories according to the analyte: proteins and small molecules.
Proteins A majority of MALDI-IMS studies have been dedicated to the study of proteins contained in animal tissue sections. Applications in the field of pathology hold particular interest for many because of the potential benefit for clinical diagnoses and treatment. Other studies have focused on proteomic events occurring in normally developing tissues; some recent examples include the direct imaging of secretory peptides from frog skin28 and bovine ocular lens proteins29, as well as neuropeptides from rat pituitary25, decapod crustacean neuronal tissue26 and house cricket30. Below we describe several examples of applications of MALDI-IMS.
Pathology. Determining molecular changes associated with disease progression continues to be a main focus of MALDI-IMS studies7,
9,
10,
31,
32,
33. The general approach taken by these studies is comparative proteomic analyses whereby mass spectral features (m/z peaks) are correlated with a variety of patient information, such as therapeutic regimen and overall outcome. Images can be generated from individual features or a combination of features that represent a signature for a particular aspect of the study.
In some cases, the goal of the experiment is to identify specific molecular changes associated with progression of disease. For these studies it is not necessary to acquire MALDI-IMS spectra from the entire section of tissue. Rather, spectra are acquired at discrete locations within the section that contain histological features of interest. The molecular signatures are then analyzed for feature differences specific to the types of cell being analyzed. For example, molecular signatures from glioma biopsies can be used to distinguish tumor grade and were found to be correlated with patient survival32.
Identification of specific cellular changes within heterogeneous tissue can be particularly challenging from the perspective of matrix spot size and placement. As the mass spectrum contains ions from proteins extracted from all cells wetted by the droplet of matrix solution, it is essential that matrix be placed as precisely as possible onto only those cells of interest. Histopathology results can be used to direct the automated deposition of matrix31. The workflow, illustrated in Figure 2, is demonstrated for a lung tumor biopsy.
 | |  | Developmental biology. Proteomic studies using MALDI-IMS can yield insight into some extremely complex biological processes. One example is the maturation of spermatozoa as they move through the epididymis (Fig. 3), interacting with protein-rich epididymal fluid to complete differentiation begun in the testis34. The epididymis is a long tubular organ composed of four anatomical regions: initial segment, caput, corpus and cauda. As spermatozoon DNA is transcriptionally inactive, the development of the capability for fertilization depends on sequential interactions between spermatozoa and proteins encountered during transit through the organ. MALDI-IMS analyses of epididymal sections have been used to determine the localized composition of the epididymal fluid from caput to cauda35, confirming that different protein compositions are found along the length of the epididymis (Fig. 3).
 | |  | In another study MALDI-IMS was used to probe proteomic changes in mouse uterine tissue surrounding a blastocyst from the time of implantation through early development (K.E. Burnum and R.M.C., unpublished data). One particularly challenging aspect of this study was the relatively small size (<3 mm diameter) of the uterine cross-section, with the developing embryo being approximately 300 m long. The tissue is extremely delicate, and image analysis required high spatial resolution and precise positioning of the matrix.
In situ protein chemistry. Sample pretreatment protocols using various enzymes and molecular tags can increase the amount of protein information obtained from MALDI-IMS analysis. Proteins can be hydrolyzed in situ, with the resulting peptides, rather than the proteins, analyzed by MALDI-IMS. Several reports have demonstrated image analysis of tissue sections treated with the enzyme trypsin15,
36. MS/MS analysis of the tryptic fragments followed by database searching was used to identify many proteins. One of the potential benefits of such an approach is the ability to localize proteins that are not readily detected by a direct MALDI-MS analysis, such as high-molecular-weight or membrane-bound or membrane-associated proteins. Photocleavable molecular tags to enhance the specificity of MALDI-IMS analyses have also been designed37,
38. In this strategy the sample section is incubated with the tagging reagent and image analysis is performed on the low-molecular-weight tag compound instead of the target molecule.
Small-molecule imaging Many compounds that are biologically or pharmacologically relevant are less than 1 kDa in size and thus fall into the broad category of small molecules. These include both exogenous and endogenous molecules, such as pharmaceutical compounds and their metabolites, drugs of abuse, environmental toxins, endogenous metabolites and lipids. Below we summarize the application of MALDI-IMS for the study of drug metabolism and phospholipid distribution.
Drug metabolism. Initial applications of small-molecule MALDI-IMS focused on pharmaceutically active compounds and their metabolites12,
19, and considerable effort continues in this field17. For example, one study reported the localization of the drug olanzapine and two first-pass metabolites in whole-rat sections12. The results of this study correlated well with both autoradiography and LC-MS/MS quantitative results, illustrating the power of MALDI-IMS for metabolite profiling. More recently, there has been considerable interest in adding quantitative capabilities to the MALDI-IMS experiment39,
40. The technology also opens up the exciting possibility of correlating drug distribution with concomitant protein changes41.
Phospholipids. Phospholipids are involved in many essential biological functions, including cell signaling, energy storage, and membrane structure and function, and defects in lipid metabolism have a role in many diseases. Analysis of lipids is challenging because of the wide molecular diversity of this class of compounds and their relative insolubility in aqueous systems. Using multiple stages of mass spectrometry21,
42, ion species may be unambiguously classified depending on how the lipid ion initially fragments. The use of ion mobility has also been reported in conjunction with MALDI MS as a means to fractionate lipids43,
44,
45. In this technique, ions are first separated by ion mobility and then analyzed by TOF mass spectrometry. The desorbed lipid ions fall on a trend line (a function of charge and collision cross-section) that is separate from those of oligonucleosides, peptides, proteins, and drugs and metabolites having the same nominal mass. This allows ions originating from lipids to be distinguished from other small molecules.
Outlook The correlation of molecular information to anatomical structures in tissues offers tremendous potential for a better understanding of biological processes. Using current technology the distribution of hundreds of proteins can be determined to spatial dimensions on the order of 50 m. Molecular sensitivity depends upon the class and size of a particular compound but is typically on the order of hundreds of amol/ m2 to low fmol/ m2. Other limiting factors include aspects of both sample preparation and instrumentation. For example, the intensity and number of discrete ions observed is a function of protein solubility, dynamic range and ion suppression effects inherent to the MALDI ionization process, as well as the limited mass resolving power of mass spectrometers. Thus, of the tens of thousands of proteins expressed in the cells of a tissue, MALDI-IMS generally produces images for only about 1,000 discrete ions. Continued growth in the number of MALDI-IMS studies will undoubtedly drive future developments for improving sensitivity.
MALDI-IMS analysis of individual cells remains a difficult task. Lateral image resolution (that is, the surface area mapped by a single pixel) is determined by the largest of the following quantities: the diameter of the focused MALDI laser beam, the pitch of the microspotted matrix array, or the size of the matrix crystals on a sprayed or spotted sample. Achieving cellular resolution will require these quantities to be reduced to subcellular dimensions. Current instrumentation is capable of producing submicron laser spots, but improvements will be needed in ejector and aerosol designs in order to produce submicron matrix crystals with 100% coverage of the sample yet without delocalizing the analyte. Further, achieving high sensitivity is important; the amount of analyte decreases markedly at smaller spot sizes. Finally, the data load increases significantly: doubling the spatial resolution increases the number of acquired mass spectra by fourfold, with concomitant increases in acquisition time and data file size.
Ion images and the mass spectra from which they are derived are based solely on m/z information. Identifying the molecular entity producing a given signal requires additional extraction, purification and either enzymatic or chemical procedures that traditionally have been wet-chemistry based. However, with the liquid spotting technology now available, it should be possible to develop protocols for chemical procedures carried out directly on the tissue section. Such procedures have already been demonstrated to facilitate the in situ identification of proteins, but there is significant potential for developing procedures for optimizing other factors such as protein extraction and ionization. Ultimately this should lead to vastly improved specificity and sensitivity for the molecular images.
The outlook for MALDI-IMS is extremely positive with great opportunity for continued growth. As instrumental capabilities become more readily available and performance improves, more investigators are exploring the technology and using it for new applications. Visualizing the distribution of the target compound along with hundreds of other molecular species simultaneously without need for target-specific reagents such as antibodies is unique to MALDI-IMS and provides investigators with another powerful imaging tool for the study of biochemical processes.
Published online: 27 September 2007.
REFERENCES
- Claydon, M.A., Davey, S.N., Edwards-Jones, V. & Gordon, D.B. The rapid identification of intact microorganisms using mass spectrometry. Nat. Biotechnol. 14, 1584–1586 (1996). | Article | PubMed | ISI | ChemPort |
- Holland, R.D. et al. Rapid identification of intact whole bacteria based on spectral patterns using matrix-assisted laser desorption/ionization with time-of-flight mass spectrometry. Rapid Commun. Mass Spectrom. 10, 1227–1232 (1996). | Article | PubMed | ISI | ChemPort |
- Krishnamurthy, T., Ross, P.L. & Rajamani, U. Detection of pathogenic and non-pathogenic bacteria by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Rapid Commun. Mass Spectrom. 10, 883–888 (1996). | Article | PubMed | ISI | ChemPort |
- Caprioli, R.M., Farmer, T.B. & Gile, J. Molecular imaging of biological samples: Localization of peptides and proteins using MALDI-TOF MS. Anal. Chem. 69, 4751–4760 (1997). | Article | PubMed | ISI | ChemPort |
- Stoeckli, M., Chaurand, P., Hallahan, D.E. & Caprioli, R.M. Imaging mass spectrometry: A new technology for the analysis of protein expression in mammalian tissues. Nat. Med. 7, 493–496 (2001). | Article | PubMed | ISI | ChemPort |
- Stauber, J. et al. New developments in MALDI imaging mass spectrometry for pathological proteomic studies; introduction to a novel concept, the specific MALDI imaging. Mol. Cell. Proteomics 5, S247–S247 (2006). | ISI |
- Skold, K. et al. Decreased striatal levels of PEP-19 following MPTP lesion in the mouse. J. Proteome Res. 5, 262–269 (2006). | Article | PubMed | ISI | ChemPort |
- Chaurand, P., Norris, J.L., Cornett, D.S., Mobley, J.A. & Caprioli, R.M. New developments in profiling and imaging of proteins from tissue sections by MALDI mass spectrometry. J. Proteome Res. 5, 2889–2900 (2006). | Article | PubMed | ISI | ChemPort |
- Stoeckli, M., Staab, D. & Schweitzer, A. Compound and metabolite distribution measured by MALDI mass spectrometric imaging in whole-body tissue sections. Int. J. Mass Spectrom. 260, 195–202 (2007). | ISI | ChemPort |
- Meistermann, H. et al. Biomarker discovery by imaging mass spectrometry — Transthyretin is a biomarker for gentamicin-induced nephrotoxicity in rat. Mol. Cell. Proteomics 5, 1876–1886 (2006). | PubMed | ISI | ChemPort |
- Kulkarni, M.J., Vinod, V.P., Umasankar, P.K., Patole, M.S. & Rao, M. Intact cell matrix-assisted laser desorption/ionization mass spectrometry as a tool to screen drugs in vivo for regulation of protein expression. Rapid Commun. Mass Spectrom. 20, 2769–2772 (2006). | Article | PubMed | ISI | ChemPort |
- Khatib-Shahidi, S., Andersson, M., Herman, J.L., Gillespie, T.A. & Caprioli, R.M. Direct molecular analysis of whole-body animal tissue sections by imaging MALDI mass spectrometry. Anal. Chem. 78, 6448–6456 (2006). | Article | PubMed | ISI | ChemPort |
- Lemaire, R. et al. Direct analysis and MALDI imaging of formalin-fixed, paraffin-embedded tissue sections. J. Proteome Res. 6, 1295–1305 (2007). | Article | PubMed | ISI | ChemPort |
- Norris, J.L. et al. Processing MALDI mass spectra to improve mass spectral direct tissue analysis. Int. J. Mass Spectrom. 260, 212–221 (2007). | PubMed | ISI | ChemPort |
- Shimma, S., Furuta, M., Ichimura, K., Yoshida, Y. & Setou, M. Direct MS/MS analysis in mammalian tissue sections using MALDI-QIT-TOFMS and chemical inkjet technology. Surf. Interface Anal. 38, 1712–1714 (2006). | Article | ISI | ChemPort |
- Aerni, H.R., Cornett, D.S. & Caprioli, R.M. Automated acoustic matrix deposition for MALDI sample preparation. Anal. Chem. 78, 827–834 (2006). | Article | PubMed | ISI | ChemPort |
- Reyzer, M.L. & Caprioli, R.M. MALDI-MS-based imaging of small molecules and proteins in tissues. Curr. Opin. Chem. Biol. 11, 29–35 (2007). | Article | PubMed | ISI | ChemPort |
- Pevsner, P.H. et al. Direct identification of proteins from T47D cells and murine brain tissue by matrix-assisted laser desorption/ionization post-source decay/collision-induced dissociation. Rapid Commun. Mass Spectrom. 21, 429–436 (2007). | Article | PubMed | ISI | ChemPort |
- Hsieh, Y. et al. Matrix-assisted laser desorption/ionization imaging mass spectrometry for direct measurement of clozapine in rat brain tissue. Rapid Commun. Mass Spectrom. 20, 965–972 (2006). | Article | PubMed | ISI | ChemPort |
- Atkinson, S.J., Loadman, P.M., Sutton, C., Patterson, L.H. & Clench, M.R. Examination of the distribution of the bioreductive drug AQ4N and its active metabolite AQ4 in solid tumours by imaging matrix-assisted laser desorption/ionisation mass spectrometry. Rapid Commun. Mass Spectrom. 21, 1271–1276 (2007). | Article | PubMed | ISI | ChemPort |
- Garrett, T.J. & Yost, R.A. Analysis of intact tissue by intermediate-pressure MALDI on a linear ion trap mass spectrometer. Anal. Chem. 78, 2465–2469 (2006). | Article | PubMed | ISI | ChemPort |
- Woods, A.S. & Jackson, S.N. Brain tissue lipidomics: direct probing using matrix-assisted laser desorption/ionization mass spectrometry. AAPS J. 8, E391–E395 (2006). | Article | PubMed | ISI |
- Spengler, B. & Hubert, M. Scanning microprobe matrix-assisted laser desorption ionization (SMALDI) mass spectrometry: instrumentation for sub-micrometer resolved LDI and MALDI surface analysis. J. Am. Soc. Mass Spectrom. 13, 735–748 (2002). | Article | PubMed | ISI | ChemPort |
- Chaurand, P., Schriver, K.E. & Caprioli, R.M. Instrument design and characterization for high resolution MALDI-MS imaging of tissue sections. J. Mass Spectrom. 42, 476–489 (2007). | Article | PubMed | ISI | ChemPort |
- Altelaar, A.F.M. et al. High-resolution MALDI imaging mass spectrometry allows localization of peptide distributions at cellular length scales in pituitary tissue sections. Int. J. Mass Spectrom. 260, 203–211 (2007). | ISI | ChemPort |
- DeKeyser, S.S., Kutz-Naber, K.K., Schmidt, J.J., Barrett-Wilt, G.A. & Li, L.J. Imaging mass spectrometry of neuropeptides in decapod crustacean neuronal tissues. J. Proteome Res. 6, 1782–1791 (2007). | PubMed | ISI | ChemPort |
- Taban, I.M. et al. Imaging of peptides in the rat brain using MALDI-FTICR mass spectrometry. J. Am. Soc. Mass Spectrom. 18, 145–151 (2007). | Article | PubMed | ISI | ChemPort |
- Brand, G.D. et al. Bradykinin-related peptides from Phyllomedusa hypochondrialis. Peptides 27, 2137–2146 (2006). | Article | PubMed | ISI | ChemPort |
- Han, J. & Schey, K.L. MALDI tissue imaging of ocular lens alpha-crystallin. Invest. Ophthalmol. Vis. Sci. 47, 2990–2996 (2006). | Article | PubMed | ISI |
- Verhaert, P.D., Conaway, M.C.P., Pekar, T.M. & Miller, K. Neuropeptide imaging on an LTQ with vMALDI source: The complete 'all-in-one' peptidome analysis. Int. J. Mass Spectrom. 260, 177–184 (2007). | ISI |
|