Abstract
The perspective of using live cells as lenses could open new revolutionary and intriguing scenarios in the future of biophotonics and biomedical sciences for endoscopic vision, local laser treatments via optical fibres and diagnostics. Here we show that a suspended red blood cell (RBC) behaves as an adaptive liquid-lens at microscale, thus demonstrating its imaging capability and tunable focal length. In fact, thanks to the intrinsic elastic properties, the RBC can swell up from disk volume of 90 fl up to a sphere reaching 150 fl, varying focal length from negative to positive values. These live optofluidic lenses can be fully controlled by triggering the liquid buffer’s chemistry. Real-time accurate measurement of tunable focus capability of RBCs is reported through dynamic wavefront characterization, showing agreement with numerical modelling. Moreover, in analogy to adaptive optics testing, blood diagnosis is demonstrated by screening abnormal cells through focal-spot analysis applied to an RBC ensemble as a microlens array.
Similar content being viewed by others
Introduction
Red blood cell (RBCs) anomalies are significant symptoms for identification of health disorders. In particular, several blood diseases involve modification in the morphology of such cells, that is, sickle-cell disease, malaria and spherocytosis1,2,3. For these reasons, many non-invasive optical imaging systems have been developed for the investigation of RBC morphology as a diagnostic clinical factor4,5,6,7,8. In particular, quantitative phase-contrast methods have been explored for three-dimensional (3D) shape retrieving of live and unlabelled erythrocytes measuring volumes, refractive indexes and morphological parameters9,10,11,12. However, all the aforementioned imaging methods require interferometric analysis and/or complex image processing for morphology retrieval in two-dimensional and 3D and, most important, the diagnosis is subjective, as it depends on the physician’s personal evaluation of such images. Moreover, huge steps forward have been taken in the last years in the field of photonic techniques applied to medical science with the aim to make less invasive and more efficient current therapies or for developing new ones. In particular, challenging results have been obtained by enlarging the potential capabilities of optical tweezers (OTs) as a no-contact tool for cell manipulation13,14,15. Recently, for the first time, optical trapping has been aimed in vivo at manipulating RBCs within subdermal capillaries on living mice16. At the same time, many efforts have been spent to go towards the miniaturization of a photonic device that could open new ways for endoscopic analysis17,18,19.
In this context, we propose a new concept where cells can be manipulated and adopted as functional and active optical elements. Specifically, we model RBCs as optofluidic nanomicrolenses20,21,22 by demonstrating, in vitro, their focus tunability and imaging capability. Human erythrocytes, in their mature state and under physiological and healthy conditions, are flexible biconcave disks with homogeneous distribution of the refractive index. By an optical point of view, we will take benefit of the intrinsic great deformability23,24,25 and the lack of nucleus and organelles26 thus modelling and demonstrating that an RBC is a sort of disk-shaped microstructured envelope that changes its shape and is exploitable as a tunable liquid-lens. In fact RBCs are very flexible and their deformability allows them to bring oxygen even through the smallest capillaries in the vascular system. RBC morphology variation is achievable by triggering the liquid buffer osmolarity thus permitting swelling from the biconcave microfluid disk, with a volume of about 90 fl, up to a sphere reaching 150 fl. By considering the RBC average refractive index4 ranging between 1.38 and 1.42 immersed in a liquid buffer with lower refractive index (1.334), we show that this focal length can change in a range of about 20 μm, from deep negative values to positive ones. A further functionality that we exploit here is about blood diagnostics. Here we demonstrate that, by exploiting the new concept of bio-microlenses and in analogy to indirect adaptive optics (IAO)-testing tools (that is, Shack–Hartmann)27, it is possible to discern between healthy and anomalous RBCs, thus providing a completely new, faster and much more objective diagnostic criterion. We will validate the RBC-focusing properties for providing full morphology identification. Any classical shape retrieval and conventional image-processing analysis will not be necessary. Examples of fast blood screening, 3D morphology retrieval and imaging properties of the RBC lens are reported.
Results
RBC focal length tunability
RBC is modelled as a pure phase object, and simulation is performed implementing a modification of the formula for the ideal RBC biconcave shape28 (see Supplementary Methods 1 and Supplementary Figs 1 and 2 for details). We consider a monochromatic plane wave propagating thorough it that behaves as an aberrated lens. Therefore the diffracted wavefront at the exit pupil of the microlens, computed using a phase-retrieval approach29, is expressed as a linear combination of Zernike polynomials30,31,32,33.
Through computation we noted that the focal properties of normal discocyte are mainly due only to the first two quadratic polynomial terms, which correspond to the contributions of Zernike coefficients of order 4 and 12, that is, focus shift, a4, and third-order spherical aberrations, a12, while other terms are negligible. Meanwhile spherocytes (Methods) can be described essentially only by a focus-shift term, a4. To demonstrate the different focal properties between discocytes and spherocytes, we employ interference (that is, digital holography (DH)) microscopy (see Methods)34,35,36,37,38. Specifically, to prove the tunable focal length of an RBC optofluidic lens, we manage a dynamic experiment switching a single RBC between discocyte (mainly a negative lens) to spherocyte (a positive lens). Noteworthy, RBCs change shape in a reversible way by varying buffers’ osmolarity (see Methods). RBC sample, immersed in isotonic solution, is injected into a micro-channel. Soon after, a hypotonic solution is introduced causing, in about 10 s, significant RBC swelling. Variation of the erythrocyte shape and consequent focal-length shifts are monitored in real time using the holographic microscope. Despite a discocyte being quite a complex lens, its focal length changes in a very clear way. Essentially, in a more accurate model, it is a lens having a strong spherical aberration. While the inner part (that is, for paraxial rays) has a negative focal length, the edges behave as a sort of toroid lens having a positive focal length for no-paraxial rays. The induced swelling of the RBC causes the substantial change of its shape, thus cancelling the central concavity. Consequently, the virtual focus (that is, negative focal spot) disappears completely while a reinforcement of the real focal spot occurs
The experimental results fully confirm this behaviour as shown in Fig. 1 and Supplementary Movie 1, where real-time measurements are compared with theoretical expectations, thus showing noteworthy agreement. In Fig. 1a, the diffraction propagation of the retrieved complex wavefront along the optical axis is reported. Wavefront is retrieved by numerical reconstruction of a real-time digital holographic recording during the experiment. The intensity distributions, in the transverse plane and along the optical axis (plane x–z), show very distinctly that, for a spherocyte RBC, the virtual focal spot vanishes completely, while the discocyte is swelling (see Supplementary Movie 1). Focal-length change during RBC swelling is also confirmed by a wavefront Zernike analysis reported in Fig. 1 and Supplementary Movie 2, where Zernike shape fitting (Fig. 1b) and principal Zernike coefficients (Fig. 1c) are calculated. It should be noted that, the theoretical trends of Zernike coefficients (left of Fig. 1c) show how the spherical aberration goes to zero; meanwhile focus shift is maximized. The same happens in the experimental case (right of Fig. 1c), for which virtual and real focal lengths of an RBC, that is, before and after its swelling, can be directly derived by Zernike coefficients. In particular, the RBC in Fig. 1 presents in this case virtual foci before the sample plane at about −7.4 μm while its real focus, after hypotonic solution adding, is calculated at a distance of about 10.8 μm. Detailed model of discocyte RBC by Zernike polynomials is described in the Supplementary Methods 1; Supplementary Figs 1 and 2. We report in Fig. 1d only the simulated maximum intensity peak correspondent to the virtual focus. The entire simulation results on the light intensities distribution is shown in Supplementary Movie 3. In literature, the scattering theory39,40 is considered for interaction of light with RBCs. However, the model described here is in the framework of geometrical optics and furnishes a good approximation of the interaction between light and the RBC lens.
RBC-biolens imaging properties
We performed a simple experimental test to demonstrate the imaging capability of an RBC. A spherocyte RBC is used to image a sub-micrometre pattern achieving an increased magnification of about 20%. For demonstrating the magnifying properties of the biolens in hypotonic solution, we inserted a piece of a digital versatile disc (DVD) (780 nm pitch) between the light source and the RBC, behaving as a biconvex lens. By considering the distance between the RBC and the grating fixed at 16 μm, and by making the approximation that a spherocyte is a thin convergent lens, with focal length equal to 9 μm, we calculate a real image with magnification Mth=1.29. In Fig. 2a a schematic view of the experiment is showed. In Fig. 2b,c a comparison between a portion of the DVD grating and the same magnified portion seen through the biolens is reported. We observe an increase in the mumber of pixels (from 26 to 32) in the magnified image of one grating period, which corresponds to Mexp≈1.22, quite in agreement with the calculated value.
Successively, we have used OTs (see Methods) to manage the position in 3D of the RBC. Magnified image of the DVD grating is visible in the centre of the cell. Supplementary Movie 4 describes the whole raster-scanning process while the RBC lens is moved first vertically along the optical axis, then in the transversal plane. The distortion of the magnified lines of the grating is due to the spherical aberration of the lens (see Fig. 2c). These results demonstrate that RBC can behave as a tunable and optofluidic lens, having an imaging capability.
Real-time blood screening through focal-spot aberrations
Once it is proved that an RBC can be seen as an optofluidic microlens, it is possible to assert that any specific RBC morphology has its own focusing property. Since any blood disease has a typical shape, this implies that erythrocytes presenting more complicated shapes or deviations from normal healthy cases can be definitely identified by their focal spots, thus allowing blood disorder identification. In fact, any deviation from the healthy RBC morphology can be read as a sum of aberrations in the propagated optical wavefront passing through the cells, exactly as it occurs for any optical system. First, we analysed separately two different samples, made of hundreds of RBC, in two different osmolarity conditions. We performed numerous tests to get data from a statistical point of view, with the aim to estimate the focal-length ranges useful to determine the percentage of healthy cells in a crowded RBC ensemble. For the spherocyte ensemble, we measure real foci in front of the microlens array at a distance of about 9.72 μm while the discocyte ensemble presents virtual foci before the sample plane at about −6.33 μm. The corresponding s.d. are 1.06 and 0.84 μm. The results are displayed in Fig. 3a,b. Viewing the RBC ensemble as an array of microlenses is, in principle, a very powerful diagnostic tool. In fact, by exploiting all the base concepts of IAO, an RBC’s full 3D morphometry can be retrieved. The innovative diagnostic aspect is demonstrated in Figs 4 and 5 and Supplementary Movie 5. The all-optical-based analysis is performed illuminating the sample with monochromatic light, necessary to have a definite focusing effect that otherwise cannot be obtained (chromatic aberrations hinder the formation of sharp focal spots as displayed in Fig. 3c). It is important to note that no interferometry is required. A very fast pre-screening test is realized where the output establishes the percentage of healthy cells from the evaluation of the spot ellipticity in the virtual focus plane. Results are reported in Fig. 4 and Supplementary Movie 5. Visualization of the spots and percentage of detected healthy and doubtful cells are furnished simultaneously, thanks to the test characteristic to be quasi real time. To validate the pre-screening process, we conducted a more sophisticated analysis based on the IAO27 to have deeper information on the real cell shape. The optical intensities in the plane behind the RBCs are recorded for the entire field of view. For each intensity focal spot, an iterative Fourier transform algorithm calculate the wavefront aberrations where the output phase is modelled as a combination of Zernike polynomials making the assumption that only tilts, focus shift, spherical aberration, astigmatism and coma terms are present. Zernike coefficients for normal discocytes are essentially two, that is, focus shift and spherical aberration terms that justify the presence of the virtual focus in the plane before the RBC ensemble. Conversely, spherocytes present the focus coefficient several orders of magnitude higher than the others thus resulting in real foci.
Finally, abnormal shapes present the other coefficients with non-negligible values. Interestingly, the retrieved wavefront expressed by the Zernike polynomials can be used for full 3D morphological visualization under symmetry assumptions41 (see Fig. 5c). The approach presented can be applied to samples made of hundreds of cells supplying information on each RBC present in the ensemble as shown in Fig. 5. Detailed description of RBC shape retrieval is reported in the Supplementary Methods and Supplementary Figs 3 and 4. The approach can be proposed as an optics-based diagnostic tool. In fact, RBC focus-footprint is a clear and simple marker about its morphology for a fast easy pre-screening in vitro analysis. In fact, as shown in Fig. 4, the method is able to detect easily the percentage of normal discocytes in an ensemble by evaluating the number of spots and their ellipticity in the calculated virtual focal plane (z=−6.33). In case the percentage of discocytes (that is, healthy cells) is low with respect to an a-priori fixed value, further and deeper analysis can be considered for retrieving abnormal RBC shapes by processing the spots’ intensities in the calculated real focal plane (z=9.72), as demonstrated in the results of Fig. 5.
Discussion
In this paper, RBCs are modelled as optofluidic microlenses with well-defined optical properties. Experimental evidences, numerical simulations and final practical application have been provided for this new concept. From the tunability experiment reported in Fig. 1 and the experimental results in Fig. 3, it is clear that spherocyte and discocyte have opposite concavities, therefore they focus laser light at real and virtual foci, behind and before the lens, respectively, thus confirming that an RBC can be considered as an optofluidic lens able to change its focal length from negative to positive values. In ref. 42, the physical properties (refractive index, shape and volume) of RBCs are characterized for several buffer’s osmolarities. We demonstrated here that the focal length depends also on the buffer chemistry and it is strictly related to such physical parameters. Therefore, in the tuning experiment, by defining the medium osmolarity, we control the final stage of RBCs in terms of focal lengths. We demonstrated the magnifying properties of the RBC when it is employed as an active lens. Indeed, a grating with a pitch of 780 nm is imaged through the RBC lens resulting in a magnification of about 1.22. Moreover, by using OTs, the RBC lens is moved in three dimensions to ‘scan’ a little part of the grating, thus behaving as a ‘guided magnifying lens’ that can be foreseen as a sort of raster-scanning imaging inside the human body. Finally, a new paradigm is opened on biomedical application. In fact, by seeing RBCs as microlens array, there is the possibility to discriminate normal healthy cells from all other abnormal shapes by analysing optical focal spots with a monochromatic or quasi-monochromatic light source. We discuss and show that the method is fast and effective and allows for unambiguous identification of discocytes RBC from all the abnormal ones by evaluating the spots ellipticity in the virtual focus plane. Such a pre-screening procedure is based on the fact that normal discocyte biolenses present focus spots placed along the optical axis but in the opposite direction with respect to the abnormal ones. Furthermore, we prove that 3D RBC shape can be evaluated through the analysis of focal spots in the biolens forward focal plane. The presented approach is developed in analogy to wavefront aberration analysis by IAO, a well-known technology usually employed in astronomy as well as in optical communications and sensing. We demonstrate that focal spots are strictly correlated to the morphology as shown in Fig. 5. Consequently, future blood diagnosis can be achieved by abandoning the concept of diagnosis through classical imaging.
The concept demonstrated here is disruptively new. In fact, at the best of our knowledge, it is the first time that a cell can be assumed as an active and tuneable lens. Experimental evidence of tunability, imaging and diagnostics reported here demonstrate in full the in vitro proof of principle. In our opinion, this could open the route for potential impacts either for future blood diagnostics and in vivo endoscopy. Recent improvement in biophotonics as the manipulation of RBCs from the outside of the vein16 and, at the same time, new papers on the miniaturization of OT on a single fibre17,43,44 could convincingly lead to envisage an integration of the presented technique for endoscopy. For example, it could be investigated a fibre-based system able to manipulate and trap RBCs inside the vein. The application could be the imaging of the RBC themselves to perform diagnosis. Indeed, by the same authors, the possibility to image a fixed object hidden by a dense flow of RBCs has been recently proved45. In particular in the Fig. 4d of such paper fixed RBCs are clearly visible thorough a dense layer of flowing erythrocytes.
Concerning in vitro blood screening, the important improvement of the presented technique is that neither image segmentation nor traditional phase computing is required, thus resulting in quasi real-time output. In fact, as shown in Fig. 5, the analysis just needs the map of the focal spots to accomplish pre-screening. Thus the proposed technique could be able to easily detect blood disorders involving shape abnormalities, for example, sickle-cell disease, spherocytosis, elliptocytosis and malaria. Moreover, it is expected that the device for such a diagnostic tool could be adapted at lab-on-chip scale, because the optical set-up is very easy as it uses only a camera and a laser light source in the visible range that indeed nowadays are very compact and of low cost.
Methods
Sample preparation and isolation of erythrocytes
All experiments were done with heparinized blood drawn within the hour before use. Healthy blood was collected from one of the co-authors, who gave informed consent. The sample was prepared as follows: ~3 ml of heparinized whole blood was withdrawn into a haematocrit tube. Blood was centrifuged at room temperature, for 15 min at 2,500 r.p.m. to separate it into its component parts (plasma, buffy coat and RBCs at the bottom of the centrifuge tube). The pellet (≈1.5 ml) was collected and 100 μl of erythrocytes were diluted with a saline solution of 0.90% w/v of sodium chloride (NaCl) in sterile water up to a final volume of 2 ml. The osmolarity of the medium was about 308 mOsm l−1 and it was isotonic with the membrane of RBCs. No visible haemolysis occurred. For the hypotonic and hypertonic solutions, we used a medium osmolarity of about 205 and 410 mOsm l−1, respectively.
When RBCs are in a hypotonic environment, the cell interiors accumulate water that flows across the cell membrane into the cell, causing it to expand. On the contrary, when the environment is hypertonic, the cell eliminates water and shrinks. Finally, in an isotonic solution, water exchange between the cell and the environment is balanced, and no change in cell volume occurs. These situations are described in Supplementary Fig. 1, resulting in different shapes of the cells depending on the tonicity of the solution.
Digital holography and the OT apparatus
We integrate a microscope based on DH arrangement and an OT modulus to simultaneously image and manipulate biological samples31,34 (Fig. 6). The DH set-up is made by a 400 -mW at 532 nm fibre-coupled laser that acts as a source for a Mach–Zehnder interferometer (Fig. 6), whose main beam is directed into a customized inverted microscope equipped with an oil immersion × 100 microscope objective, allowing bright-field imaging of the cells. The reference beam is recombined with the first one by a beam splitter generating interference fringe patterns (called digital holograms) of the samples that are recorded by a 1,024 × 1,024 charge-coupled device camera (AVT Technologies). The OT apparatus is realized by using a 3-W infrared laser source in combination with a Phase Only Spatial Light Modulator (by Holo-Eye), with the aim of trapping and moving multiple RBC lenses in 3D. In particular, the OT modulus is used to demonstrate the imaging properties of RBCs (Supplementary Movie 4). The trapping laser emits at 1,064 nm; the beam is expanded to fit the aperture of the spatial light modulator operating in reflection mode. Then, the laser beam is injected into the microscope objective (mumerical apperture=1.25) thorough a standard 4f optical configuration (not shown for simplicity). RBCs (after separation from the other blood cells) are placed in a Petri dish and analysed by this apparatus.
Additional information
How to cite this article: Miccio, L. et al. Red blood cell as an adaptive optofluidic microlens. Nat. Commun. 6:6502 doi: 10.1038/ncomms7502 (2015).
References
Ford, J. Red blood cell morphology. Int. J. Lab. Hematol. 35, 351–357 (2013) .
Khairy, K., Foo, J. J. & Howard, J. Shapes of red blood cells: comparison of 3D confocal images with the bilayer-couple model. Cell Mol. Bioeng. 1, 173–181 (2008) .
Lim, G., Wortis, M. & Mukhopadhyay, R. Stomatocyte–discocyte–echinocyte sequence of the human red blood cell: Evidence for the bilayer–couple hypothesis from membrane mechanics. Proc. Natl Acad. Sci. USA 99, 16766–16769 (2002) .
Park, Y. K. et al. Refractive index maps and membrane dynamics of human red blood cells parasitized by Plasmodium falciparum. Proc. Natl Acad. Sci. USA 105, 13730–13735 (2008) .
Rappaz, B. et al. Measurement of the integral refractive index and dynamic cell morphometry of living cells with digital holographic microscopy. Opt. Express 13, 9361–9373 (2005) .
Mavandadi, S. et al. A mathematical framework for combining decisions of multiple experts toward accurate and remote diagnosis of malaria using tele-microscopy. PloS ONE 7, 46192 (2012) .
Yi, F., Moon, I., Javidi, B., Boss, D. & Marquet, P. Automated segmentation of multiple red blood cells with digital holographic microscopy. J. Biomed. Opt. 18, 026006 (2013) .
Kim, K., Kim, K. S., Park, H. J., Ye, J. C. & Park, Y. K. Real-time visualization of 3-D dynamic microscopic objects using optical diffraction tomography. Opt. Express 21, 32269–32278 (2013) .
Kim, T. et al. White-light diffraction tomography of unlabelled live cells. Nat. Photon. 8, 256–263 (2014) .
Moon, I., Javidi, B., Yi, F., Boss, D. & Marquet, P. Automated statistical quantification of three-dimensional morphology and mean corpuscular hemoglobin of multiple red blood cells. Opt. Express 20, 10295–10309 (2012) .
Roma, P. M. S., Siman, L., Amaral, F. T., Agero, U. & Mesquita, O. N. Total three-dimensional imaging of phase objects using defocusing microscopy: Application to red blood cells. App. Phys. Lett. 104, 251107 (2014) .
Ding, H. & Popescu, G. in Coherent Light Microscopy-Imaging and Phase Analysis (eds Ferraro, P., Wax, A. and Zalevsky, Z) Ch. 9 (Springer series in surface sciences) (Springer, 2010) .
Jordan, P. et al. Creating permanent 3D arrangements of isolated cells using holographic optical tweezers. Lab Chip 5, 1224–1228 (2005) .
Dholakia, K. & Cizmar, T. Shaping the future of manipulation. Nat. Photon. 5, 335–342 (2011) .
Grier, D. G. A revolution in optical manipulation. Nature 424, 810–816 (2003) .
Zhong, M.-C., Wei, X.-B., Zhou, J.-H., Wang, Z.-Q. & Li, Y.-M. Trapping red blood cells in living animals using optical tweezers. Nat. Commun. 4, 1768 (2012) .
Liberale, C. et al. in Lab-on-Fiber Technology Vol. 56 eds Cusano A., Consales M., Crescitelli A., Ricciardi A. Ch. 8 (Springer Series in Surface Sciences) (Springer, 2015) .
Psaltis, D., Quake, S. R. & Yang, C. Developing optofluidic technology through the fusion of microfluidics and optics. Nature 442, 381–386 (2006) .
Schmidt, H. & Hawkins, A. R. The photonic integration of non-solid media using optofluidics. Nat. Photon. 5, 598–604 (2011) .
McLeod, E. & Ozcan, A. Nano-imaging enabled via self-assembly. Nano Today 9, 560–573 (2014) .
Lee, J. Y. et al. Near-field focusing and magnification through self-assembled nanoscale spherical lenses. Nat. Lett. 460, 498–501 (2009) .
Dong, L., Agarwal, A. K., Beebe, D. J. & Jiang, H. Adaptive liquid microlenses activated by stimuli responsive hydrogels. Nat. Lett. 442, 551–554 (2006) .
McWhirter, J. L., Noguchi, H. & Gompper, G. Flow-induced clustering and alignment of vesicles and red blood cells in microcapillaries. Proc. Natl Acad. Sci. USA 106, 6039–6043 (2009) .
Bambardekar, K., Dharmadhikari, A. K., Dharmadhikari, J. A., Mathur, D. & Sharma, S. Measuring erythrocyte deformability with fluorescence, fluid forces, and optical trapping. J. Biomed. Opt. 13, 064021 (2008) .
Saraogi, V., Padmapriya, P., Apurba, P., Tatu, U. S. & Natarajan, V. Change in spectrum of Brownian fluctuations of optically trapped red blood cells due to malarial infection. J. Biomed. Opt. 15, 037003 (2010) .
Tycko, D. H., Metz, M. H., Epstein, E. A. & Grinbaum, A. Flow-cytometric light scattering measurement of red blood cell volume and hemoglobin concentration. Appl. Opt. 24, 1355–1365 (1985) .
Booth, M. J. Adaptive optics in microscopy. Philos. Trans. A Math. Phys. Eng. Sci. 365, 2829–2843 (2007) .
Yu, L., Sheng, Y. & Chou, A. Three-dimensional light-scattering and deformation of individual biconcave human blood cells in optical tweezers. Opt. Express 21, 12174–12184 (2013) .
Fienup, J. R. Phase retrieval algorithms: a personal tour. Appl. Opt. 52, 45–56 (2013) .
Zernike, F. Beugungstheorie des Schneidenverfahrens und Seiner Verbesserten Form, der Phasenkontrastmethode. Physica 1, 689–704 (1934) .
Malacara, D. & DeVare, S. L. in Optical Shop Testing 2nd edn ed. Malacara D. Ch. 13, 455–495Wiley Interscience (1992) .
Miccio, L. et al. Direct full compensation of the aberrations in quantitative phase microscopy of thin objects by a single digital hologram. App. Phys. Lett. 90, 041104 (2007) .
Miccio, L. et al. Tunable liquid microlens arrays in electrode-less configuration and their accurate characterization by interference microscopy. Opt. Express 17, 2487–2499 (2009) .
Kemper, B. et al. in Handbook of Coherent-Domain Optical Methods (ed. Tuchin V. V. Ch. 6, Springer (2013) .
Merola, F. et al. Digital holography as a method for 3D imaging and estimating biovolume of motile cells. Lab Chip 13, 4512–4516 (2013) .
Cardenas, N. & Mohanty, S. K. Optical tweezers assisted quantitative phase imaging led to thickness mapping of red blood cells. App. Phys. Lett. 103, 013703 (2013) .
Cotte, Y. et al. Marker-free phase nanoscopy. Nat. Photon. 7, 113–117 (2013) .
Miccio, L. et al. Particle tracking by full-field complex wavefront subtraction in digital holography microscopy. Lab Chip 14, 1129–1134 (2014) .
Lim, J. et al. Born approximation model for light scattering by red blood cells. Biomed. Opt. Express 2, 2784–2791 (2011) .
Ding, H. F., Wang, Z., Nguyen, F., Boppart, S. A. & Popescu, G. Fourier transform light scattering of inhomogeneous and dynamic structures. Phys. Rev. Lett. 101, 238102 (2008) .
Memmolo, P. et al. 3D morphometry of red blood cells by digital holography. Cytometry A 85, 1030–1036 (2014) .
Park, Y. K. et al. Measurement of the nonlinear elasticity of red blood cell membranes. Phys. Rev. E 83, 051925 (2011) .
Zeng, X., Smith, C. T., Gould, J. C., Heise, C. P. & Jiang, H. Fiber endoscopes utilizing liquid tunable-focus microlenses actuated through infrared light. J. Microelectromech. Syst. 20, 583–593 (2011) .
Aljasem, K., Werber, A., Seifert, A. & Zappe, H. Fiber optic tunable probe for endoscopic optical coherence tomography. J. Opt. A Pure Appl. Opt. 10, 044012 (2008) .
Bianco, V. et al. Imaging adherent cells in the microfluidic channel hidden by flowing RBCs as occluding objects by a holographic method. Lab Chip 14, 2499 (2014) .
Author information
Authors and Affiliations
Contributions
L.M., P.M., F.M. and F.P. conceived and designed the research and wrote the manuscript. P.F. and P.A.N. supervised the project. F.M. and L.M. performed the experiments; P.M. made all the numerical models and numerical analysis. All the authors revised the results and the manuscript.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing financial interests.
Supplementary information
Supplementary Figures, Supplementary Methods and Supplementary References
Supplementary Figures 1-4, Supplementary Methods and Supplementary References (PDF 519 kb)
Supplementary Movie 1
Comparison of the dynamic focusing properties of a simulated RBC vs. a real RBC while its shape changes from discocyte to spherocyte. This movie shows the tuneable optofluidic focusing feature of a RBC. The shape variation is obtained by changing the osmolarity of the liquid buffer. (MOV 1435 kb)
Supplementary Movie 2
Zernike analysis and focusing properties variation of a simulated RBC vs. a real RBC during the liquid buffer osmolarity change. The movie shows RBC's shapes fitting by using 2D Zernike polynomials and a detailed analysis of Zernike coefficients that influence the focusing properties of RBC (focus shift and third order spherical aberration). (MOV 4227 kb)
Supplementary Movie 3
numerical simulation showing the focusing effect of three different RBCs cells (i.e. spherocite, discocyte and crenate, respectively). It can be noted that spherocyte focuses at positive distances while healthy discocyte RBC focuses light at negative focal point behind the lens. On contrary a crenate RBC does not show focusing effect. (MOV 2856 kb)
Supplementary Movie 4
Spherocyte RBC employed as micro-lens: imaging of a nanostructure and 20% improvement of the optical magnification. The RBC positions is managed by an optical tweezers setup. (MOV 1639 kb)
Supplementary Movie 5
Demonstration of focusing properties as diagnostic tool. Realtime and fast blood screening by analyzing focal spots created by an ensemble of RBCs. No shape retrieval is necessary for discocyte identification. The fast and accurate estimation of healthy cells vs. abnormal ones can be easily obtained. (MOV 4423 kb)
Rights and permissions
About this article
Cite this article
Miccio, L., Memmolo, P., Merola, F. et al. Red blood cell as an adaptive optofluidic microlens. Nat Commun 6, 6502 (2015). https://doi.org/10.1038/ncomms7502
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/ncomms7502
This article is cited by
-
Light distribution in fat cell layers at physiological temperatures
Scientific Reports (2023)
-
Lipid droplets: a cellular organelle vital in cancer cells
Cell Death Discovery (2023)
-
Multiplexed spatially-focused localization of light in adipose biological tissues
Scientific Reports (2022)
-
Biophotonic probes for bio-detection and imaging
Light: Science & Applications (2021)
-
Cellular lensing and near infrared fluorescent nanosensor arrays to enable chemical efflux cytometry
Nature Communications (2021)
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.